Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Specific features of propagation of femtosecond laser pulses through a molecular gaseous medium under conditions of efficient alignment of molecules

The propagation of femtosecond laser pulses in a molecular gaseous medium is studied with the rotational dynamics of molecules under the action of these pulses taken into account. Based on the simultaneous numerical solution of the wave equation describing the laser pulse evolution and the Schroedinger equation that determines the quantum state evolution of the medium molecules, the rotational dynamics of molecules in the laser field and the laser pulse evolution are analysed with their mutual influence taken into account. Efficient dynamic alignment of molecules along the direction of laser radiation polarisation is observed, which causes variation in the spatiotemporal pulse profile, as well as significant broadening and deformation of its spectrum in the course of propagation through the medium. The physical mechanisms of the observed phenomena are analysed by using the approximate analytical solution of the problem, derived for the case of preliminary excitation of the medium by a pump pulse (the pump-probe scheme). (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE INTRINSIC ALIGNMENTS OF THE LATE-TYPE SPIRAL GALAXIES FROM THE SLOAN DIGITAL SKY SURVEY DATA RELEASE 7

A robust detection of the tidally induced intrinsic alignments of the late-type spiral galaxies with high statistical significance is reported. From the spectroscopic galaxy sample of Sloan Digital Sky Survey DR7 compiled by Huertas-Company et al., which lists each galaxy's probabilities of being in five Hubble types, P(E), P(Ell), P(S0), P(Sab), P(Scd), we select the nearby large late-type spiral galaxies which have redshifts of 0 {<=} z {<=} 0.02, probabilities of P(Scd) {>=} 0.5, and angular sizes of D {>=} 7.92 arcsec. The spin axes of the selected nearby large late-type spiral galaxies are determined up to the two-fold ambiguity with the help of the circular thin-disk approximation, and their spatial correlations are measured as a function of the separation distance r. A clear signal of the intrinsic correlation as high as 3.4{sigma} and 2.4{sigma} is found at the separation distance of r {approx} 1 h{sup -1} Mpc and r {approx} 2 h{sup -1} Mpc, respectively. The comparison of this observational results with the analytic model based on the tidal torque theory reveals that the spin correlation function for the late-type spiral galaxies follows the quadratic scaling of the linear density correlation and that the intrinsic correlations of the galaxy spin axes are stronger than that of the underlying dark halos. We investigate a local density dependence of the galaxy spin correlations and found that the correlations are stronger for the galaxies located in dense regions having more than 10 neighbors within 2 h{sup -1} Mpc. We also attempt to measure a luminosity dependence of the galaxy spin correlations, but find that it is impossible with our magnitude-split samples to disentangle a luminosity from a redshift dependence. We provide the physical explanations for these observational results and also discuss the effects of possible residual systematics on the results.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SL2S GALAXY-SCALE GRAVITATIONAL LENS SAMPLE. I. THE ALIGNMENT OF MASS AND LIGHT IN MASSIVE EARLY-TYPE GALAXIES AT z = 0.2-0.9

We study the relative alignment of mass and light in a sample of 16 massive early-type galaxies at z = 0.2-0.9 that act as strong gravitational lenses. The sample was identified from deep multi-band images obtained as part of the Canada-France-Hawaii Telescope Legacy Survey and as part of the Strong Lensing Legacy Survey (SL2S). Higher resolution follow-up imaging is available for a subset of 10 systems. We construct gravitational lens models and infer total enclosed mass, elongation, and position angle of the mass distribution. By comparison with the observed distribution of light we infer that there is a substantial amount of external shear with mean value ({gamma}{sub ext}) = 0.12 {+-} 0.05, arising most likely from the environment of the SL2S lenses. In a companion paper, we combine these measurements with follow-up Keck spectroscopy to study the evolution of the stellar and dark matter content of early-type galaxies as a function of cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

ALIGNMENT BETWEEN FLATTENED PROTOSTELLAR INFALL ENVELOPES AND AMBIENT MAGNETIC FIELDS

We present 350 {mu}m polarization observations of four low-mass cores containing Class 0 protostars: L483, L1157, L1448-IRS2, and Serp-FIR1. This is the second paper in a larger survey aimed at testing magnetically regulated models for core-collapse. One key prediction of these models is that the mean magnetic field in a core should be aligned with the symmetry axis (minor axis) of the flattened young stellar object inner envelope (aka pseudodisk). Furthermore, the field should exhibit a pinched or hourglass-shaped morphology as gravity drags the field inward toward the central protostar. We combine our results for the four cores with results for three similar cores that were published in the first paper from our survey. An analysis of the 350 {mu}m polarization data for the seven cores yields evidence of a positive correlation between mean field direction and pseudodisk symmetry axis. Our rough estimate for the probability of obtaining by pure chance a correlation as strong as the one we found is about 5%. In addition, we combine together data for multiple cores to create a source-averaged magnetic field map having improved signal-to-noise ratio, and this map shows good agreement between mean field direction and pseudodisk axis (they are within 15 Degree-Sign ). We also see hints of a magnetic pinch in the source-averaged map. We conclude that core-scale magnetic fields appear to be strong enough to guide gas infall, as predicted by the magnetically regulated models. Finally, we find evidence of a positive correlation between core magnetic field direction and bipolar outflow axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining universal and odd RR axions for aligned natural inflation

We successfully embed the Kim-Nilles-Peloso (KNP) alignment mechanism for enhancing the axion decay constant in the context of large volume type IIB orientifolds. The flat direction is generated in the plane of (C{sub 0}-C{sub 2}) axions corresponding to the involutively even universal axion C{sub 0} and odd axion C{sub 2}, respectively. The moduli stabilization with large volume scheme has been established as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanical stability of the CMS strip tracker measured with a laser alignment system

The CMS tracker consists of 206 m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from −25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPIN-ORBIT ALIGNMENT FOR THE CIRCUMBINARY PLANET HOST KEPLER-16 A

Kepler-16 is an eccentric low-mass eclipsing binary with a circumbinary transiting planet. Here, we investigate the angular momentum of the primary star, based on Kepler photometry and Keck spectroscopy. The primary star's rotation period is 35.1 {+-} 1.0 days, and its projected obliquity with respect to the stellar binary orbit is 1.{sup 0}6 {+-} 2.{sup 0}4. Therefore, the three largest sources of angular momentum-the stellar orbit, the planetary orbit, and the primary's rotation-are all closely aligned. This finding supports a formation scenario involving accretion from a single disk. Alternatively, tides may have realigned the stars despite their relatively wide separation (0.2 AU), a hypothesis that is supported by the agreement between the measured rotation period and the 'pseudosynchronous' period of tidal evolution theory. The rotation period, chromospheric activity level, and fractional light variations suggest a main-sequence age of 2-4 Gyr. Evolutionary models of low-mass stars can match the observed masses and radii of the primary and secondary stars to within about 3%.

79 ASTRONOMY AND ASTROPHYSICS↗

Alignment-dependent ionization of hydrogen molecules in intense laser fields

Recent experiments showed that the alignment-dependent ionization probabilities of hydrogen molecules vary as a function of laser intensity, and the anisotropy deviates from the prediction of the molecular tunneling ionization model (MO-ADK). To investigate the physical origins of the deviation, we systematically studied the anisotropy of hydrogen molecules in intense laser fields for three wavelengths, 400 nm (multiphoton ionization), 1850 nm (tunneling ionization), and 800 nm (in between), by solving the time-dependent Schroedinger equation with a model potential. The calculated ratio of the ionization probabilities for laser fields parallel and perpendicular to the molecular axis are in reasonable agreement with experiment. Furthermore, by analyzing the molecular wave function and the model potential, we found that the discrepancies between experiment and the MO-ADK prediction originated from the inaccurate coefficients used in the model and that the assumption of isotropy of the effective potential in the tunneling region is invalid.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of laser-induced field-free permanent planar alignment of molecules

Permanent planar alignment of gas-phase linear molecules is achieved by a pair of delayed perpendicularly polarized short laser pulses. The experiment is performed in a supersonic jet, ensuring a relatively high number density of molecules with moderately low rotational temperature. The effect is optically probed on a femtosecond time scale by the use of a third short pulse, enabling a time-resolved birefringence detection performed successively in two perpendicular planes of the laboratory frame. The technique allows for an unambiguous estimation of the molecular planar delocalization produced within the polarization plane of the pulse pair after the turn-off of the field. The measurements are supported by numerical simulations which lead to the quantification of the observed effect and provide more physical insights into the phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alignment of sample position and rotation during in situ synchrotron X-ray micro-diffraction experiments using a Laue cross-correlation approach

Laue micro-diffraction has proven to be able to reveal material properties at the sub-grain scale for many polycrystalline materials and is now routinely available at several synchrotron facilities, providing an approach for nondestructive three-dimensional probing of the microstructures and mechanical states of materials. However, for in situ experiments, maintaining the positioning of the sample throughout the experiment, to achieve a good alignment of the characterized volumes, is a challenging issue. The aim of the present work is to address this problem by developing an approach based on digital image correlation of focused-beam Laue diffraction patterns. The method uses small changes in the diffraction signal as a focused X-ray beam is scanned over a surface region to allow corrections to be made for both sample lateral movement and rotation. The method is demonstrated using a tensile deformation experiment on an Al sample with 2.5 µm average grain size. The results demonstrate an accuracy of 0.5 µm for sample position registration and a precision in sample rotation of ~0.01°. Finally, the proposed method is fast to implement and does not require the use of additional surface markers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

A Multithreaded Algorithm for Network Alignment Via Approximate Matching

Network alignment is an optimization problem to find the best one-to-one map between the vertices of a pair of graphs that overlaps in as many edges as possible. It is a relaxation of the graph isomorphism problem and is closely related to the subgraph isomorphism problem. The best current approaches are entirely heuristic, and are iterative in nature. They generate real-valued heuristic approximations that must be rounded to find integer solutions. This rounding requires solving a bipartite maximum weight matching problem at each step in order to avoid missing high quality solutions. We investigate substituting a parallel, half-approximation for maximum weight matching instead of an exact computation. Our experiments show that the resulting difference in solution quality is negligible. We demonstrate almost a 20-fold speedup using 40 threads on an 8 processor Intel Xeon E7-8870 system (from 10 minutes to 36 seconds).

network alignment, matching, multicore↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Ridge effect and alignment phenomenon

It is assumed that the ridge effect observed by the CMS Collaboration in proton-proton collisions at the LHC and the phenomenon observed by the Pamir Collaboration in emulsion experiments with cosmic rays and characterized by the alignment of spots on a film is a manifestation of the same as-yet-unknown mechanism of the emergence of a coplanar structure of events. A large coplanar effect at the LHC in the region of forward rapidities is predicted on the basis of this hypothesis and an analysis of experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MiNAA: Microbiome Network Alignment Algorithm

A microbial network is a mathematical representation of a microbial community where nodes represent microbes and edges represent interactions. It is well-recognized that microbes are among the main drivers of biological phenotypes in soil, plants, and animals alike, and thus, their study has vast implications for soil, plant and human health. In particular, recognizing the microbial, environmental, and agricultural factors that drive plant and soil phenotypes is crucial to comprehend processes connected to plant and soil health, to identify global practices of sustainable agriculture, as well as to predict plant and soil responses to environmental perturbations such as climate change. The adaptability of microbes to thrive in every environment poses challenges for scientists who try to understand their communities. Indeed, two microbial communities with the exact same players can interact differently depending on the environmental conditions. It is thus desirable to identify commonalities and differences on two microbial networks, hence the need for computational tools that can match (or align) them.

97 MATHEMATICS AND COMPUTING↗