An ultrasonic transducer with Gaussian radial velocity distribution

A transducer with a velocity profile which is Gaussian as a function of radius and independent of angle is described. In materials evaluation applications requiring the interrogation of modified far field patterns of an ultrasonic transducer, it is desirable to use a transducer which produces a beam with a Gaussian profile. A computer aided electrode design and calibrated three dimensional interferometric optical and ultrasonic measurements of the far field distribution are presented.

Zerwekh, P. S.↗

2D electron density profile measurement in tokamak by laser-accelerated ion-beam probe

A new concept of Heavy Ion Beam Probe (HIBP) diagnostic has been proposed, of which the key is to replace the electrostatic accelerator of traditional HIBP by a laser-driven ion accelerator. Due to the large energy spread of ions, the laser-accelerated HIBP can measure the two-dimensional (2D) electron density profile of tokamak plasma. In a preliminary simulation, a 2D density profile was reconstructed with a spatial resolution of about 2 cm, and with the error below 15% in the core region. Diagnostics of 2D density fluctuation is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-BRD-04: Beam Modeling and Validation with Triple and Double Gaussian Dose Kernel for Spot Scanning Proton Beams

Purpose: To present the validity of our beam modeling with double and triple Gaussian dose kernels for spot scanning proton beams in Nagoya Proton Therapy Center. This study investigates the conformance between the measurements and calculation results in absolute dose with two types of beam kernel. Methods: A dose kernel is one of the important input data required for the treatment planning software. The dose kernel is the 3D dose distribution of an infinitesimal pencil beam of protons in water and consists of integral depth doses and lateral distributions. We have adopted double and triple Gaussian model as lateral distribution in order to take account of the large angle scattering due to nuclear reaction by fitting simulated inwater lateral dose profile for needle proton beam at various depths. The fitted parameters were interpolated as a function of depth in water and were stored as a separate look-up table for the each beam energy. The process of beam modeling is based on the method of MDACC [X.R.Zhu 2013]. Results: From the comparison results between the absolute doses calculated by double Gaussian model and those measured at the center of SOBP, the difference is increased up to 3.5% in the high-energy region because the large angle scattering due to nuclear reaction is not sufficiently considered at intermediate depths in the double Gaussian model. In case of employing triple Gaussian dose kernels, the measured absolute dose at the center of SOBP agrees with calculation within ±1% regardless of the SOBP width and maximum range. Conclusion: We have demonstrated the beam modeling results of dose distribution employing double and triple Gaussian dose kernel. Treatment planning system with the triple Gaussian dose kernel has been successfully verified and applied to the patient treatment with a spot scanning technique in Nagoya Proton Therapy Center.

07 ISOTOPE AND RADIATION SOURCES↗

Formation of electron bunches with tailored current profiles using multi-frequency linacs

Tailoring an electron bunch with specific current profile can provide substantial enhancement of the transformer ratio in beam-driven acceleration methods. We present a method relying on the use of a linac with accelerating sections operating at different frequencies followed by a magnetic bunch compressor. The experimental verfification of the technique in a two-frequency linac is presented. The compatibility of the proposed technique with the formation and acceleration of a drive and witness bunches is numerically demonstrated.

43 PARTICLE ACCELERATORS↗

Rain rate range profiling from a spaceborne radar

At certain frequencies and incidence angles the relative invariance of the surface scattering properites over land can be used to estimate the total attenuation and the integrated rain from a spaceborne attenuation-wavelength radar. The technique is generalized so that rain rate profiles along the radar beam can be estimated, i.e., rain rate determination at each range bin. This is done by modifying the standard algorithm for an attenuating-wavelength radar to include in it the measurement of the total attenuation. Simple error analyses of the estimates show that this type of profiling is possible if the total attenuation can be measured with a modest degree of accuracy.

Meneghini, R.↗

Acoustic Gaussian Far-Field Pattern

Gaussian profile achieved by using annular electrodes. Transducer constructed by deposting circularly symmetric metallic multielectrode array on 12.7 mm diameter X-cut quartz disk. Each electrode independently connected to impedance network optimized to produce Gaussian distribution with less than 2 percent error. Ultrasonic transducer produces far field beam with Gaussian spatial profile for materials evaluation applications.

Claus, R. O.↗

Properties of cyclotron lines in a line-forming region injected by an anisotropic continuum in accreting X-ray pulsars

I examine the characteristics of profiles of cyclotron lines formed by the superposition of a number of lines formed at a number of altitudes in line-forming regions illuminated by anisotropic injections in an accretion column, which formed around the polar cap of Roche-lobe-type accretion-powered X-ray pulsars. In the present paper, I consider the line-forming region near the walls of a cylindrical geometry illuminated from the inside of the cylinder. I also examine how the direction of the peak of a beam pattern affects the profiles of cyclotron lines. I found that the width and depth of the line in a phase-averaged spectrum provide information concerning the direction of a beam. I demonstrate that the cyclotron line has a pure absorption in the phase-averaged spectrum regardless of the height of the cylinder, which is expected to change with luminosity. On the other hand, in phase-resolved spectra, an emission-like feature can be formed in the phase with lower intensity in a short cylinder, which is expected at L∼10{sup 36} erg s{sup −1}, while a pure absorption feature tends to appear in all phases due to the superposition of a large number of lines in a tall cylinder, which is expected at L≳10{sup 37} erg s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Evolution of dark state of an open atomic system in constant intensity laser field

We studied experimentally and theoretically the evolution of open atomic systems in the constant intensity laser field. The study is performed by analyzing the line shapes of Hanle electromagnetically induced transparency (EIT) obtained in different segments of a laser beam cross section of constant intensity, i.e., a {Pi}-shaped laser beam. Such Hanle EIT resonances were measured using a small movable aperture placed just in front of the photodetector, i.e., after the entire laser beam had passed through the vacuum Rb cell. The laser was locked to the open transition F{sub g}=2{yields}F{sub e}=1 at the D{sub 1} line of {sup 87}Rb with laser intensities between 0.5 and 4 mW/cm{sup 2}. This study shows that the profile of the laser beam determines the processes governing the development of atomic states during the interaction. The resonances obtained near the beam center are narrower than those obtained near the beam edge, but the significant changes of the linewidths occur only near the beam edge, i.e., right after the atom enters the beam. The Hanle EIT resonances obtained near the beam center exhibit two pronounced minima next to the central maximum. The theoretical model reveals that the occurrence of these transmission minima is a joint effect of the preparation of atoms into the dark state and the optical pumping into the uncoupled ground level F{sub g}=1. The appearance of the transmission minima, although similar to that observed in the wings of a Gaussian beam [A. J. Krmpot et al., Opt. Express 17, 22491 (2009)], is of an entirely different nature for the {Pi}-shaped laser beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

Self focusing of a quadruple Gaussian laser beam in a plasma

The self focusing of a quadruple Gaussian laser beam, comprising four coherent identical Gaussian beams with axes parallel to z-caret but shifted from z-axis by -x{sub 0}x-caret,x{sub 0}x-caret,-x{sub 0}y-caret,x{sub 0}y-caret in a collisionless plasma, is investigated in the paraxial ray approximation. The nonlinearity arises through the ponderomotive force led plasma density redistribution. As the beam propagates, it maintains the shape of its intensity profile with spot size r{sub 0} of each of the four distributions modified from r{sub 0} to r{sub 0}f, x{sub 0}, modified to x{sub 0}f and the axial intensity enhanced by 1/f{sup 2}, where f is the beam width parameter. In the regime of quadratic nonlinearity, the threshold beam power for self focusing, P{sub th}, increases with x{sub 0} as the laser intensity gradient decreases and the ponderomotive force becomes weaker. At beam power greater than P{sub th}, the beam focuses in an oscillatory manner, i.e., f varies periodically with z due to the saturating effect of nonlinearity. The locations of intensity maxima of the four beams also vary periodically with z. As x{sub 0} increases from 0 to 0.6r{sub 0}, the transverse intensity gradient becomes weaker and the rate of self focusing, i.e., the rate of variation of f with z decreases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intrinsic rotation generation in ELM-free H-mode plasmas in the DIII-D tokamak--Experimental observations

A detailed description is presented of the experiment reported in [S. H. Mueller et al., Phys. Rev. Lett. 106, 115001 (2011)], which reported the first measurements of fluid turbulent stresses in a tokamak H-mode pedestal. Mach probe measurements disclosed a narrow co-current rotation layer at the separatrix, which is also seen in some L-modes [J. A. Boedo et al., Phys. Plasmas 18, 032510 (2011)]. Independent evidence for the existence of the edge co-rotation layer is presented from main-ion rotation measurements by charge-exchange-recombination spectroscopy in comparable helium plasmas. The probe measurements are validated against density and electron temperature profiles from Thomson scattering and in terms of the measured turbulent particle transport, which is consistent with the global density rise. Non-diffusive non-convective angular momentum transport is required by two independent experimental observations: (1) A persistent dip in the rotation profile separates the edge layer from the evolving core region during intrinsic rotation development. (2) The rotation profiles with co- and counter-current neutral beam injection appear well described as the simple sum of a constant intrinsic part and the beam-driven part, also demonstrating the profile-independence of the intrinsic torque. Characteristics of the turbulent fluctuations composing the fluid turbulent stresses are discussed: Up to 0.5 cm inside the separatrix, the low amplitude of the Reynolds stress (<0.05 Nm of torque) is due to both a reduction of the fluctuation amplitudes at the peak of the edge co-rotation layer and weak correlations between the toroidal and radial velocity fluctuations. Further into the core, the correlations increase significantly up to a value of +0.75, resulting in an almost unidirectional character of the turbulent Reynolds stress, generating substantial counter-current torques up to -2 Nm. Additional mechanisms must be present to balance these torques and explain the co-current core-plasma spin-up at a rate of +0.3 Nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Separating and combining single-mode and multimode optical beams

Techniques for combining initially separate single mode and multimode optical beams into a single "Dual Mode" fiber optic have been developed. Bi-directional propagation of two beams that are differentiated only by their mode profiles (i.e., wavefront conditions) is provided. The beams can be different wavelengths and or contain different modulation information but still share a common aperture. This method allows the use of conventional micro optics and hybrid photonic packaging techniques to produce small rugged packages suitable for use in industrial or military environments.

47 OTHER INSTRUMENTATION↗

Enhancement of thickness uniformity of thin films grown by pulsed laser deposition

A peculiarity of the pulsed laser deposition technique of thin-film growth which limits its applicability is the very rapid drop of resulting film thickness as a function of distance from the deposition axis. This is due to the narrow forward peaking of the emission plume characteristic of the laser ablation process. The plume is usually modeled by a cos(sup n) theta function with n greater, and in some cases, much higher, than 1. Based on this behavior, a method is presented to substantially enhance coverage uniformity in substrate zones of the order of the target-substrate distance h, and to within a specified thickness tolerance. Essentially, target irradiation is caused to form an annular emission source instead of the usual spot. By calculating the resulting thickness profiles, an optimum radius s is found for the annular source, corresponding to a given power in the emission characteristic and a given value of h. The radius of this annulus scales with h. Calculated numerical results for optimal s/h ratios corresponding to a wide range of values for n are provided for the case of +/- 1% tolerance in deviation from the thickness at deposition axis. Manners of producing annular illumination of the target by means of conic optics are presented for the case of a laser beam with radially symmetric profile. The region of uniform coverage at the substrate can be further augmented by extension of the method to multiple concentric annular sources. By using a conic optic of novel design, it is shown also how a single-laser beam can be focused onto a target in the required manner. Applicability of the method would be limited in practice by the available laser power. On the other hand, the effective emitting area can be large, which favors extremely high growth rates, and since growth can occur uniformly over the whole substrate for each laser pulse, single-shot depositions with substantial thicknesses are possible. In addition, the simultaneity of growth over the complete substrate is desirable when monitoring the growth in situ.

Fernandez, Felix E.↗

WE-EF-BRA-06: Feasibility of Spatially Modulated Proton Beams for Small Animal Research

Purpose: To investigate the feasibility of proton minibeam radiotherapy (pMBRT) for small animal research. The motivation is to explore with protons the extraordinary normal tissue sparing effects to spatially modulated beams as observed on high flux synchrotron beam lines. We hypothesized that we can design a multi-slit collimator for our proton beam line to produce planar-parallel dose profiles with high modulation in the entrance region and homogenous dose coverage in the overlap of the Bragg peaks. Methods: The high dose rate 50 MeV research proton beamline at the University of Washington was modeled using the TOol for PArticle Simulation (TOPAS) Monte Carlo package. A brass collimator was implemented to generate proton minibeams. The collimator consists of an array of 2 cm long slits to cover an area of 2×2 cm{sup 2}. The slit widths (0.1–1 mm), center-to-center (ctc) distances (1–3 mm) and collimator thickness (1–7 cm) were varied to evaluate the effect on dose rate, the peak-to-valley dose ratios (PVDR) and the change of penumbra and peak width (FWHM) with depth. Results: The Bragg peak was at a depth of ∼21 mm. The penumbra and FWHM remained relatively constant to a depth of about 10–15 mm. The PVDR ranged from 1.6 to 26 and the dose rate dropped exponentially with collimator thickness. A uniform dose can be achieved at depth with slightly compromised PVDRs and dose rate. Conclusion: The technical realization of pMBRT is feasible. The simulations have shown that it is possible to obtain uniform dose at depth while modulation is maintained on the entrance side. While the simulated beam widths are larger than on synchrotron generated microbeams the dosimetric advantage could avoid having to interlace two microbeams to achieve uniform dose in the target. The next steps are to build a collimator and verify the simulations experimentally.

60 APPLIED LIFE SCIENCES↗

Electron-Beam Shaping in the Transmission Electron Microscope: Control of Electron-Beam Propagation Along Atomic Columns

We present a detailed analysis of the propagation of high-energy electron beams that have different shapes in a crystal of [100]-oriented zincblende GaN. Our study primarily focuses on Bessel beams and makes use of reformulated Bloch wave and multislice simulations. As a result of the simplicity of the momentum spectrum of a Bessel beam and the symmetry of the crystal, its propagation in the material can be described in a free-space representation, providing a deeper understanding of channeling phenomena and of probe intensity oscillation in the propagation direction. We also consider aperture-limited and Gaussian beams. As a result, the latter probes are shown to be optimal for coupling to 1s Bloch states and achieving minimal spreading along atomic columns.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-G-JeP2-15: Proton Beam Behavior in the Presence of Realistic Magnet Fields

Purpose: To investigate the effects of magnetic fields on proton therapy beams for integration with MRI. Methods: 3D magnetic fields from an open-bore superconducting MRI model (previously developed by our group) and 3D magnetic fields from an in-house gradient coil design were applied to various mono energetic proton pencil beam (80MeV to 250MeV) simulations. In all simulations, the z-axis of the simulation geometry coincided with the direction of the B0 field and magnet isocentre. In each simulation, the initial beam trajectory was varied. The first set of simulations performed was based on analytic magnetic force equations (analytic simulations), which could be rapidly calculated yet were limited to propagating proton beams in vacuum. The second set is full Monte Carlo (MC) simulations, which used GEANT4 MC toolkit. Metrics such as the beam position and dose profiles were extracted. Comparisons between the cases with and without magnetic fields present were made. Results: The analytic simulations served as verification checks for the MC simulations when the same simulation geometries were used. The results of the analytic simulations agreed with the MC simulations performed in vacuum. The presence of the MRI’s static magnetic field causes proton pencil beams to follow a slight helical trajectory when there were some initial off-axis components. The 80MeV, 150MeV, and 250MeV proton beams rotated by 4.9o, 3.6o, and 2.8o, respectively, when they reached z=0cm. The deflections caused by gradient coils’ magnetic fields show spatially invariant patterns with a maximum range of 0.5mm at z=0cm. Conclusion: This investigation reveals that both the MRI’s B0 and gradient magnetic fields can cause small but observable deflections of proton beams at energies studied. The MRI’s static field caused a rotation of the beam while the gradient coils’ fields effects were spatially invariant. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

Beam Characterization at the Neutron Radiography Facility

The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Progress Made in the Development of High-Energy UV Transmitter

In this paper, the status of an all-solid-state UV converter development for ozone sensing applications is discussed. A high energy Nd:YAG laser for pumping the UV converter arrangement was recently reported. The pump is an all-solid-state, single longitudinal mode, and conductively cooled Nd:YAG laser operating at 1064 nm wavelength. Currently, this pump laser provides an output pulse energy of greater than 1J/pulse at 50 Hz PRF and a pulsewidth of 22 ns with an electrical-to-optical system efficiency of greater than 7% and a M(sup 2) value of approx. 2. The spatial profile of the output beam is a rectangular super Gaussian. This Nd:YAG pump laser has been developed to pump the nonlinear optics based UV converter arrangement to generate 320 nm and 308 nm wavelengths by means of 532 nm wavelength. Previously, this UV converter arrangement has demonstrated IR-to-UV conversion efficiency of 24% using a flash lamp pumped laser providing a round, flat top spatial profile. Recently, the UV converter was assembled and tested at NASA LaRC for pumping with the diode pumped Nd:YAG laser. With current spatial profile, the UV converter was made operational. Current efforts to maximize the nonlinear conversion efficiency by refining its spatial profile to match RISTRA OPO requirements are progressing.

Prasad, Narasimha S.↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗