Search NASA⌕ Search

SEARCH · Search NASA

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Target Detection via Cognitive Radars Using Change-Point Detection, Learning, and Adaptation

Many radar detection algorithms that assume a stationary environment (clutter) have been proposed and analyzed over the years. However, in practice, changes in the nonstationary environment can perturb the parameters of the clutter distribution, or even alter the clutter distribution family, which can greatly deteriorate the target detection capability. To avoid such potential performance degradation, cognitive radar systems are envisioned which are required to rapidly realize the nonstationarity, accurately learn the new characteristics of the environments, and adaptively update the detector. In this paper, aiming to develop a fully cognitive radar for target detection in nonstationary environments, we propose a unifying framework that integrates (i) change-point detection of clutter distributions by using a data-driven cumulative sum (CUSUM) algorithm and its extended version, (ii) learning/identification of clutter distribution by applying sparse theory and kernel density estimation methods, and (iii) adaptive target detection by automatically modifying the likelihood-ratio test and corresponding detection threshold. Further, with extensive numerical examples, we demonstrate the achieved improvements in detection performance due to the proposed framework in comparison to a nonadaptive case, an adaptive matched filter (AMF) method, and the clairvoyant case. Herein, we also use Wilcoxon rank-sum tests to evaluate the statistical significance of the performance improvements

42 ENGINEERING↗

A New Approach to Computing Normal Tissue Complication Probability of an Intensity-Modulated Radiotherapy Treatment with Stereotactic Radiotherapy Boost of Nasopharyngeal Carcinoma: A Case Study

We attempted to develop a method to compute the normal tissue complication probability (NTCP) of various critical organs from combined intensity-modulated radiotherapy (IMRT) and stereotactic radiotherapy (SRT) boost treatment of nasopharyngeal carcinoma (NPC), with the aid of a nonlinear image registration method. The SRT's planning computed tomography (CT) of a NPC patient treated with IMRT was warped to the IMRT's planning CT using a nonlinear image registration. Because CT and dose were inherently in-register, the entire dose distribution could be deformed using the same deformation field derived from the two CT sets. Using the biologically effective dose concept and the linear-quadratic model, physical doses of IMRT and SRT were converted to a 2Gy-per-fraction equivalent dose to facilitate dose summation. The variation of organs' maximum doses of the combined treatments between traditional maximum dose sum and the proposed method was 1.5Gy {+-} 1.7Gy. After the correction of the effect of fractionation and dose heterogeneity within each organ, NTCP of each organ of interest was computed for the combined treatments. Based on the results of this case study, it is believed that dose registration could be a method for the NTCP computation of various critical organs when different fractionation schemes of radiation therapy treatment are instituted.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Atmospheric River Tracking Method Intercomparison Project (ARTMIP): Quantifying Uncertainties in Atmospheric River Climatology

Atmospheric rivers (ARs) are now widely known for their association with high-impact weather events and long-term water supply in many regions. Researchers within the scientific community have developed numerous methods to identify and track of ARs—a necessary step for analyses on gridded data sets, and objective attribution of impacts to ARs. These different methods have been developed to answer specific research questions and hence use different criteria (e.g., geometry, threshold values of key variables, and time dependence). Furthermore, these methods are often employed using different reanalysis data sets, time periods, and regions of interest. The goal of the Atmospheric River Tracking Method Intercomparison Project (ARTMIP) is to understand and quantify uncertainties in AR science that arise due to differences in these methods. This paper presents results for key AR-related metrics based on 20+ different AR identification and tracking methods applied to Modern-Era Retrospective Analysis for Research and Applications Version 2 reanalysis data from January 1980 through June 2017. We show that AR frequency, duration, and seasonality exhibit a wide range of results, while the meridional distribution of these metrics along selected coastal (but not interior) transects are quite similar across methods. Furthermore, methods are grouped into criteria-based clusters, within which the range of results is reduced. AR case studies and an evaluation of individual method deviation from an all-method mean highlight advantages/disadvantages of certain approaches. For example, methods with less (more) restrictive criteria identify more (less) ARs and AR-related impacts. Finally, this paper concludes with a discussion and recommendations for those conducting AR-related research to consider.

Rutz, Jonathan J.↗

SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-06: Evaluation of the Performance of Very High-Energy Electron (VHEE) Beams in Radiotherapy: Five Clinical Cases

Purpose: To evaluate the performance of 100–120 MeV very-high energy electron (VHEE) scanning pencil beams to radiotherapy by means of Monte Carlo (MC) simulations. Methods: We selected five clinical cases with target sizes of 1.2 cm{sup 3} to 990.4 cm{sup 3}. We calculated VHEE treatment plans using the MC EGSnrc code implemented in a MATLAB-based graphical user interface developed by our group. We generated phase space data for beam energies: 100 and 120 MeV and pencil beam spot sizes of 1, 3, and 5 mm at FWHM. The number of equidistant beams considered in this work was 16 or 32. Dose was calculated and then imported into a research version of RayStation where treatment plan optimization was performed. We compared the VHEE plans with the clinically delivered volumetric modulated arc therapy (VMAT) plan to evaluate VHEE plans performance. Results: VHEE plans provided the same PTV coverage and dose homogeneity than VMAT plans for all the cases. In average, the mean dose to organs at risk (OARs) was 24% lower for the VHEE plans. The structures that benefited the most from using VHEE were: large bowel for the esophagus case, chest wall for the liver case, brainstem for the acoustic case, carina for the lung case, and genitalia for the anal case, with 23.7–34.6% lower dose. VHEE dose distributions were more conformal than VMAT solution as confirmed by conformity indices CI100 and CI50. Integral dose to the body was in average 19.6% (9.2%–36.5%) lower for the VHEE plans. Conclusion: We have shown that VHEE plans resulted in similar or superior dose distributions compared to clinical VMAT plans for five different cases and a wide range of target volumes, including a case with a small target (1.2 cm{sup 3}), which represents a challenge for VMAT planning and might require the use of more complex non-coplanar VMAT plans. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Laboratories AB. E Hynning: Employee, RaySearch Laboratories AB. B Qu: None. B Loo Jr.: Research support, RaySearch, Varian. P Maxim: Research support, RaySearch, Varian.

60 APPLIED LIFE SCIENCES↗

Comparison of forward and inverse cam generation methods for the design of cam-linkage mechanisms

This paper presents a comparison between the forward and inverse cam generation methods applied to the design of a multi-lobed cam-rocker slider mechanism for function generation. In the forward method, the cam profile is specified directly and then the linkage output is determined using kinematics. In the inverse method, the trajectory of the output link is specified first and then the cam profile is determined using inverse linkage kinematics. First, the cam-linkage mechanism is introduced, and relevant kinematic equations are presented. Then, the cam generation methods are thoroughly explained. Here, the two cam generation methods are applied to a case study of a hydraulic motor using a multi-lobed cam and multiple linkage mechanisms. While the forward method has direct control of the cam shape, the inverse method has direct control of the linkage output and offers an advantage in calculation speed. For the mechanism selected, the cam designed with the inverse method achieved a reduction of at least 50.97% in the torque ripple when compared to the cam designed with the forward method.

42 ENGINEERING↗

The Application of the FDTD Method to Millimeter-Wave Filter Circuits Including the Design and Analysis of a Compact Coplanar

The finite difference time domain (FDTD) method is applied to the analysis of microwave, millimeter-wave and submillimeter-wave filter circuits. In each case, the validity of this method is confirmed by comparison with measured data. In addition, the FDTD calculations are used to design a new ultra-thin coplanar-strip filter for feeding a THz planar-antenna mixer.

Millimeter-wave filter Coplanar-Strip filter↗

Remapping between meshes with isoparametric cells: a case study

We explore an intersection-based remap method between meshes consisting of isoparametric elements. We present algorithms for the case of serendipity isoparametric elements (QUAD8 elements) and piece-wise constant (cell-centered) discrete fields. We demonstrate convergence properties of this remap method with a few numerical experiments.

97 MATHEMATICS AND COMPUTING↗

A validated methodology for the prediction of heating and cooling energy demand for buildings within the Urban Heat Island: Case-study of London

This paper describes a method for predicting air temperatures within the Urban Heat Island at discreet locations based on input data from one meteorological station for the time the prediction is required and historic measured air temperatures within the city. It uses London as a case-study to describe the method and its applications. The prediction model is based on Artificial Neural Network (ANN) modelling and it is termed the London Site Specific Air Temperature (LSSAT) predictor. The temporal and spatial validity of the model was tested using data measured 8 years later from the original dataset; it was found that site specific hourly air temperature prediction provides acceptable accuracy and improves considerably for average monthly values. It thus is a very reliable tool for use as part of the process of predicting heating and cooling loads for urban buildings. This is illustrated by the computation of Heating Degree Days (HDD) and Cooling Degree Hours (CDH) for a West-East Transect within London. The described method could be used for any city for which historic hourly air temperatures are available for a number of locations; for example air pollution measuring sites, common in many cities, typically measure air temperature on an hourly basis. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of the implicit MacCormack scheme to the PNS equations

The two-dimensional parabolized Navier-Stokes equations are solved using MacCormack's (1981) implicit finite-difference scheme. It is shown that this method for solving the parabolized Navier-Stokes equations does not require the inversion of block tridiagonal systems of algebraic equations and allows the original explicit scheme to be employed in those regions where implicit treatment is not needed. The finite-difference algorithm is discussed and the computational results for two laminar test cases are presented. Results obtained using this method for the case of a flat plate boundary layer are compared with those obtained using the conventional Beam-Warming scheme, as well as those obtained from a boundary layer code. The computed results for a more severe test of the method, the hypersonic flow past a 15 deg compression corner, are found to compare favorably with experiment and a numerical solution of the complete Navier-Stokes equations.

Lawrence, S. L.↗

Verification benchmarks for single-phase flow in three-dimensional fractured porous media

Flow in fractured porous media occurs in the earth’s subsurface, in biological tissues, and in man-made materials. Fractures have a dominating influence on flow processes, and the last decade has seen an extensive development of models and numerical methods that explicitly account for their presence. To support these developments, four benchmark cases for single-phase flow in three-dimensional fractured porous media are presented. Furthermore, the cases are specifically designed to test the methods’ capabilities in handling various complexities common to the geometrical structures of fracture networks. Based on an open call for participation, results obtained with 17 numerical methods were collected. This paper presents the underlying mathematical model, an overview of the features of the participating numerical methods, and their performance in solving the benchmark cases.

97 MATHEMATICS AND COMPUTING↗

Parallel methods for dynamic simulation of multiple manipulator systems

In this paper, efficient dynamic simulation algorithms for a system of m manipulators, cooperating to manipulate a large load, are developed; their performance, using two possible forms of parallelism on a general-purpose parallel computer, is investigated. One form, temporal parallelism, is obtained with the use of parallel numerical integration methods. A speedup of 3.78 on four processors of CRAY Y-MP8 was achieved with a parallel four-point block predictor-corrector method for the simulation of a four manipulator system. These multi-point methods suffer from reduced accuracy, and when comparing these runs with a serial integration method, the speedup can be as low as 1.83 for simulations with the same accuracy. To regain the performance lost due to accuracy problems, a second form of parallelism is employed. Spatial parallelism allows most of the dynamics of each manipulator chain to be computed simultaneously. Used exclusively in the four processor case, this form of parallelism in conjunction with a serial integration method results in a speedup of 3.1 on four processors over the best serial method. In cases where there are either more processors available or fewer chains in the system, the multi-point parallel integration methods are still advantageous despite the reduced accuracy because both forms of parallelism can then combine to generate more parallel tasks and achieve greater effective speedups. This paper also includes results for these cases.

Mcmillan, Scott↗

Advanced Solution Methods for Microkinetic Models of Catalytic Reactions: A Methanol Synthesis Case Study

Microkinetic models, combined with experimentally measured reaction rates and orders, play a key role in elucidating detailed reaction mechanisms in heterogeneous catalysis and have typically been solved as systems of ordinary differential equations. In this work, we demonstrate a new approach to fitting those models to experimental data. For the specific example treated here, by reformulating a typical microkinetic model for a continuous stirred tank reactor to a system of nonlinear equations, we achieved a 1000-fold increase in solution speed. The reduced computational cost allows a more systematic search of the parameter space, leading to better fits to the available experimental data. We applied this approach to the problem of methanol synthesis by CO/CO2 hydrogenation over a supported-Cu catalyst, an important catalytic reaction with a large industrial interest and potential for large-scale CO2 chemical fixation.

Environmental Molecular Sciences Laboratory↗

Quantifying the impact of temporal analysis of products reactor initial state uncertainties on kinetic parameters

The temporal analysis of products (TAP) reactor, a transient kinetic tool, provides users with information as the catalyst state evolves. However, the state of the art for TAP uncertainty quantification only considers the experimental noise present in the outlet flow signal. Additional sources of uncertainty, including, but not limited to, initial surface coverages, the catalyst zone location, the inert void fraction, and the gas pulse intensity and pulse delay, are not included. For this reason, a framework for quantifying all uncertainty sources present in TAP experiments is presented and applied to a carbon monoxide oxidation case study. Herein, two methods for quantifying these sources of uncertainty are introduced. The first utilizes initial state sensitivities to approximate the parameter variances, as well as to provide insights into the structural certainty of the model. The second generates parameter confidence distributions through an ensemble-based sampling algorithm. This initial state covariance matrix can ultimately be merged with the experimental noise covariance matrix, providing a unified description of the parameter uncertainties for a single TAP experiment.

36 MATERIALS SCIENCE↗

Sequential formulation of all‐way coupled finite strain thermoporomechanics for largely deformable gas hydrate deposits

We develop a numerically stable sequential formulation of thermoporomechanics for largely deformable gas hydrate deposits, extended from the fixed stress split of infinitesimal transformation. Constitutive equations are based on the total Lagrangian approach for both flow and geomechanics, including dynamic full tensor permeability and thermal conductivity updated from the deformation gradient. For space discretization, we take the cell-centered finite volume and node-based finite element method for flow and geomechanics, respectively. Then, we propose a sequential implicit method for all-way coupled thermoporomechanics, where the nonisothermal multiphase flow problem of gas hydrates is solved implicitly first and then the geomechanics problem is solved implicitly at the next step. During solution of the flow problem, we fix the rate of first Pioal total stress for numerical stability as well as apply porosity correction and entropy correction to account for geomechanical effects. We test numerical examples where flow and geomechanics parameters are based on deep oceanic gas hydrate deposits. When applying depressurization, even though the results between the infinitesimal transformation and finite strain geomechanics are similar in the early stages due to small deformation, we find differences between them in the late times as deformation becomes large. Accordingly, permeability and thermal conductivity tensors become nonisotropic full tensors although they are initially isotropic. Furthermore, we identify numerical stability of the developed sequential method from the test cases that exhibit the highly complex coupled gas hydrate systems with large deformation. Thus, the proposed sequential formulation can be applied in largely deformable gas hydrate systems.

42 ENGINEERING↗

Veneziano variations: how unique are string amplitudes?

String theory offers an elegant and concrete realization of how to consistently couple states of arbitrarily high spin. But how unique is this construction? In this paper we derive a novel, multi-parameter family of four-point scattering amplitudes exhibiting i) polynomially bounded high-energy behavior and ii) exchange of an infinite tower of high-spin modes, albeit with a finite number of states at each resonance. These amplitudes take an infinite-product form and, depending on parameters, exhibit mass spectra that are either unbounded or bounded, thus corresponding to generalizations of the Veneziano and Coon amplitudes, respectively. For the bounded case, masses converge to an accumulation point, a peculiar feature seen in the Coon amplitude but more recently understood to arise naturally in string theory [1]. Importantly, our amplitudes contain free parameters allowing for the customization of the slope and offset of the spin-dependence in the Regge trajectory. We compute all partial waves for this multi-parameter class of amplitudes and identify unitary regions of parameter space. For the unbounded case, we apply similar methods to derive new deformations of the Veneziano and Virasoro-Shapiro amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computing black hole partition functions from quasinormal modes

We propose a method of computing one-loop determinants in black hole space-times (with emphasis on asymptotically anti-de Sitter black holes) that may be used for numerics when completely-analytic results are unattainable. The method utilizes the expression for one-loop determinants in terms of quasinormal frequencies determined by Denef, Hartnoll and Sachdev in [1]. A numerical evaluation must face the fact that the sum over the quasinormal modes, indexed by momentum and overtone numbers, is divergent. A necessary ingredient is then a regularization scheme to handle the divergent contributions of individual fixed-momentum sectors to the partition function. To this end, we formulate an effective two-dimensional problem in which a natural refinement of standard heat kernel techniques can be used to account for contributions to the partition function at fixed momentum. We test our method in a concrete case by reproducing the scalar one-loop determinant in the BTZ black hole background. Furthermore, we then discuss the application of such techniques to more complicated spacetimes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗