Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

An industrial perspective of the LANDSAT opportunity

The feasibility of enhancing LANDSAT products to provide the greatest usability low cost data possible can be determined through government sponsorship and finance of one or more task forces composed of a critical number of experts in multiple disciplines from many industries and academia. The synergism of multiple minds addressing singular problems without the creation of permanent or perpetual structures must yield output in the form of implementable specifications, even if presented as alternatives. Changes are needed within the spacecraft in order to account for Sun angle changes. The use of pointing accuracy to make geometric corrections (and possible radiometric corrections, is needed more than onboard data reduction and information extraction, which assume a proper knowledge of application and reduce potential utilization. Multilinear arrays need to be investigated and methods for sensor calibration and for determining the effects of atmospheric inversion, as well as the best way to back out the modulation transfer function must be determined.

Williams, B. F.↗

Thermal monitoring, measurement, and control system for a Volatile Condensable Materials (VCM) test apparatus

A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.

Ives, R. E.↗

Measurements of the properties of solar wind plasma relevant to studies of its coronal sources

Interplanetary measurements of the speeds, densities, abundances, and charge states of solar wind ions are diagnostic of conditions in the source region of the solar wind. The absolute values of the mass, momentum, and energy fluxes in the solar wind are not known to an accuracy of 20%. The principal limitations on the absolute accuracies of observations of solar wind protons and alpha particles arise from uncertain instrument calibrations, from the methods used to reduce the data, and from sampling biases. Sampling biases are very important in studies of alpha particles. Instrumental resolution and measurement ambiguities are additional major problems for the observation of ions heavier than helium. Progress in overcoming some of these measurement inadequacies is reviewed.

Neugebauer, M.↗

Doppler line profile analysis for a multichannel Fabry-Perot interferometer

A new method of instrument calibration and data analysis is presented for single-etalon interferometric measurements of winds, temperatures, and emission line intensities. The technique has been developed for the multichannel Fabry-Perot interferometer on the Dynamics Explorer spacecraft. A numerical representation of the instrumental transfer function is used based on a truncated Fourier series with empirically determined coefficients. The numerical form is compared with the conventional analytic form. The Fourier coefficients describing the instrument function are generated at the wavelength of a stable He-Ne laser and are translated to other wavelengths using an interpolation technique for both phase and power. A quasi-linear least-squares fitting process involving matrices provides for a rapid and accurate data reduction.

Killeen, T. L.↗

How to design and construct multielement ultrasonic transducers

The practical 'how to' design and construction of multielement ultrasonic transducers are described. First, design procedures based on direct calculations of the desired acoustic field are reviewed. Second, techniques for implementing these designs using piezoelectric active elements are discussed. Finally, optical and acoustic test methods for transducer calibration are indicated.

Burrier, R. A.↗

Calibration requirements and methodology for remote sensors viewing the ocean in the visible

The calibration requirements for ocean-viewing sensors are outlined, and the present methods of effecting such calibration are described in detail. For future instruments it is suggested that provision be made for the sensor to view solar irradiance in diffuse reflection and that the moon be used as a source of diffuse light for monitoring the sensor stability.

Gordon, Howard R.↗

Theoretical study of the dissociation energy and the red and violet band systems of CN

The dissociation energy (D sub O) of CN is determined to be 7.65 + or - 0.06 eV. This corresponds to delta H sub f (CN) = 105.3 + or - 1.5 kcal/mole, in excellent agreement with Engleman and Rouse (1975), but considerably larger than the recent value deduced from shock-tube studies by Colket (1984). The result is obtained not only from extensive ab initio MRCI calculations using a very large Gaussian basis set, but also from extrapolation of the directly computed value by comparison of computed and experimental results fo NO, C2, and N2. As an additional calibration of the methods, the D sub O value for CN was computed from the corresponding value for CN(-) using the experimental electron affinity data. The lifetime of the nu prime = 0 level of the violet (B 2 sigma + yields X 2 sigma +) system was computed to be 62.4 ns, in good agreement with both experiment and previous calculations. Lifetimes for the red (A 2 pi yields X 2 sigma +) system decrease with increasing nu prime, which is consistent both with the recent experiment and calculations. While the computed lifetimes are significantly longer that those obtained from the experiment, they are shorter than those deduced from an analysis of the solar spectrum. However the D sub O and f (sub OO) are consistent with Lambert's model for the solar spectrum.

Bauschlicher, Charles W., Jr.↗

Summary of results and conclusions based on analysis of volume imaging and high spectral resolution lidar data acquired during FIRE phase 1, part 1

The collection of long term global statistics on cloud cover may be most easily accomplished with satellite based observations; however, measurements derived from passive satellite retrieval methods must be calibrated and verified by in situ or ground based remote sensor observations. Verification is not straight forward, however, because the highly variable nature of cloud altitude, morphology, and optical characteristics complicates the scaling of point measurements to satellite footprint sized areas. This is particularly evident for cirrus clouds which may be organized on horizontal scales of 10's of meters to 8 km or more, and have optical depths ranging from less than .003 to greater than 3. Cirrus clouds can strongly influence earths' radiative balance, but, because they are often transmissive, cirrus clouds are difficult to detect and characterize from satellite measurements. Because of its precise ranging capabilities, spatial resolution and sensitivity, lidar observations have played an important role in the detection, depiction, and characterization of cirrus clouds. Some of the characteristics of cirrus clouds are summarized which observed the High Spectral Resolution and Volume Imaging Lidars during the phase 1 IFO and ETO periods.

Grund, Christian J.↗

MODIS technical report series. Volume 3: MODIS airborne simulator level 1B data user's guide

The purpose of this document is to describe the characteristics of moderate resolution imaging spectroradiometer (MODIS) airborne simulator level 1B data, the calibration and geolocation methods used in processing, the structure and format of the level 1B data files, and methods for accessing the data. The MODIS airborne simulator is a scanning spectrometer which flies on a NASA ER-2 and provides spectral information similar to that which will be provided by the MODIS.

Gumley, Liam E.↗

Application of airborne field mill data for use in launch support

An airborne field mill (ABFM) system was implemented on a Learjet 36A and was used to collect electric-field and microphysical data for summertime convective clouds near Cape Canaveral and the Kennedy Space Center. This system is described and the method used for calibrating it is outlined. Data from this ABFM system were used to investigate the relationship between the strengths of electric fields at the boundaries of summer maritime convective clouds and the distances from these cloud where the fields could first be detected by this system. The relationship between the electric-field strengths at the boundaries of convective clouds and selected radar-measurable parameters of these clouds were also investigated. This study shows promise that the radar volume of these clouds can be used to estimate the order of magnitude electric-field intensity. It is possible that selected remote radar measurements could be incorporated into the launch commit criteria as a means of providing greater confidence and flexibility for determining safe stand-off distances for launch vehicles from convective clouds.

Harris-Hobbs, Ray↗

High Reynolds Number Effects on Multi-Hole Probes and Hot Wire Anemometers

The paper reports on the results from an experimental investigation of the response of multi-hole and hot wire probes at high flow Reynolds numbers (Re approx. 10(exp 6)). The limited results available in literature for 5-hole probes are restricted to Re approx. 10(exp 4). The experiment aims to investigate the probe response (in terms of dimensionless pressure ratios, characterizing pitch, and yaw angles and the total and static pressures) at high Re values and to gauge their effect on the calculated velocity vector. Hot wire calibrations were also undertaken with a parametric variation of the flow pressure, velocity and temperature. Different correction and calibration schemes are sought to be tested against the acquired data set. The data is in the analysis stage at the present time. The test provided good benchmark quality data that can be used to test future calibration and testing methods.

Ramachandran, N.↗

Hypersonic Wind Tunnels: Latest Citations from the Aerospace Database

The bibliography contains citations concerning the design, construction, operation, performance, and use of hypersonic wind tunnels. References cover the design of flow nozzles, diffusers, test sections, and ejectors for tunnels driven by compressed air, high-pressure gases, or cryogenic liquids. Methods for flow calibration, boundary layer control, local and freestream turbulence reduction, and force measurement are discussed. Intrusive and non-intrusive instrumentation, sources of measurement error, and measurement corrections are also covered. The citations also include the testing of inlets, nozzles, airfoils, and other components of hypersonic aerospace vehicles. Comprehensive coverage of supersonic and blowdown wind tunnels, and force balance systems for wind tunnels are covered in separate bibliographies.

BIBLIOGRAPHIES↗

Supersonic Wind Tunnels (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning the design, construction, operation, performance, and use of supersonic wind tunnels. References cover the design of flow nozzles, diffusers, test sections, and ejectors for tunnels driven by compressed air, high-pressure gases, or cryogenic liquids. Methods for flow calibration, boundary layer control, local and freestream turbulence reduction, and force measurement are discussed. Instrusive and non-intrusive instrumentation, sources of measurement error, and measurement corrections are also covered. The citations also include the testing of inlets, nozzles, airfoils, and other components of aerospace vehicles that must operate supersonically. Comprehensive coverage of wind tunnel force balancing systems, and blowdown and supersonic wind tunnels are covered in separate bibliographies.(Contains 50-250 citations and includes a subject term index and title list.)

WIND TUNNELS↗

Critical Analyses of Data Differences Between FNMOC and AFGWC Spawned SSM/I Datasets

Antenna temperatures and the corresponding geolocation data from the five sources of the Special Sensor Microwave/Imager data from the Defense Meteorological Satellite Program F11 satellite have been characterized. Data from the Fleet Numerical Meteorology and Oceanography Center (FNMOC) have been compared with data from other sources to define and document the differences resulting from different processing systems. While all sources used similar methods to calculate antenna temperatures, different calibration averaging techniques and other processing methods yielded temperature differences. Analyses of the geolocation data identified perturbations in the FNMOC and National Environmental Satellite, Data and Information Service data. The effects of the temperature differences were examined by generating rain rates using the Goddard Scattering Algorithm. Differences in the geophysical precipitation products are directly attributable to antenna temperature differences.

Ritchie, Adrian A., Jr.↗

Uncertainty Analysis of Instrument Calibration and Application

Experimental aerodynamic researchers require estimated precision and bias uncertainties of measured physical quantities, typically at 95 percent confidence levels. Uncertainties of final computed aerodynamic parameters are obtained by propagation of individual measurement uncertainties through the defining functional expressions. In this paper, rigorous mathematical techniques are extended to determine precision and bias uncertainties of any instrument-sensor system. Through this analysis, instrument uncertainties determined through calibration are now expressed as functions of the corresponding measurement for linear and nonlinear univariate and multivariate processes. Treatment of correlated measurement precision error is developed. During laboratory calibration, calibration standard uncertainties are assumed to be an order of magnitude less than those of the instrument being calibrated. Often calibration standards do not satisfy this assumption. This paper applies rigorous statistical methods for inclusion of calibration standard uncertainty and covariance due to the order of their application. The effects of mathematical modeling error on calibration bias uncertainty are quantified. The effects of experimental design on uncertainty are analyzed. The importance of replication is emphasized, techniques for estimation of both bias and precision uncertainties using replication are developed. Statistical tests for stationarity of calibration parameters over time are obtained.

Tripp, John S.↗

Theoretical Study of the First Transition Row Oxides and Sulfides

The first transition row oxides and sulfides are studied using several different levels of theory. The calculations show the bonding mechanism in the sulfides and oxides to be very similar. For the oxides, accurate experimental data allow the theoretical methods to be calibrated. The same level of theory is used to study the sulfides where there is far less experimental information. For ScO through MnO and CuO the coupled cluster singles and doubles technique including a perturbational estimate of the unliked triple excitations [CCSD(T)] yields spectroscopic constants ((tau)e, (omega)e, and D0) in good agreement with experiment. The triple excitations are found to be very important in achieving this accuracy. For FeO to NiO, the single determinant self-consistent-field (SCF) approach yields pi orbitals that are localized on the metal or oxygen. This appears to cause problems for the single reference techniques; this is discussed in detail for NiO. The complete-active-space SCF/internally contracted averaged coupled pair functional approach (CASSCF/ICACPF) works well for FeO to NiO. The calculation of accurate dipole moments is found to be very difficult.

Bauschlicher, Charles W., Jt.↗

Formation of Carbon Nanotube Based Gears: Quantum Chemistry and Molecular Mechanics Study of the Electrophilic Addition of o-Benzyne to Fullerenes, Graphene, and Nanotubes

Considerable progress has been made in recent years in chemical functionalization of fullerene molecules. In some cases, the predominant reaction products are different from those obtained (using the same reactants) from polycyclic aromatic hydrocarbons (PAHs). One such example is the cycloaddition of o-benzyne to C60. It is well established that benzyne adds across one of the rings in naphthalene, anthracene and other PAHs forming the [2+4] cycloaddition product (benzobicyclo[2.2.2.]-octatriene with naphthalene and triptycene with anthracene). However, Hoke et al demonstrated that the only reaction path for o-benzyne with C60 leads to the [2+2] cycloaddition product in which benzyne adds across one of the interpentagonal bonds (forming a cyclobutene ring in the process). Either reaction product results in a loss of aromaticity and distortion of the PAH or fullerene substrate, and in a loss of strain in the benzyne. It is not clear, however, why different products are preferred in these cases. In the current paper, we consider the stability of benzyne-nanotube adducts and the ability of Brenner's potential energy model to describe the structure and stability of these adducts. The Brenner potential has been widely used for describing diamondoid and graphitic carbon. Recently it has also been used for molecular mechanics and molecular dynamics simulations of fullerenes and nanotubes. However, it has not been tested for the case of functionalized fullerenes (especially with highly strained geometries). We use the Brenner potential for our companion nanogear simulations and believe that it should be calibrated to insure that those simulations are physically reasonable. In the present work, Density Functional theory (DFT) calculations are used to determine the preferred geometric structures and energetics for this calibration. The DFT method is a kind of ab initio quantum chemistry method for determining the electronic structure of molecules. For a given basis set expansion, it is comparable in accuracy to the MP2 method (better than Hartree Fock, but less accurate than more extensive electron correlation methods such as MP4 or CCSD). However, for systems with large numbers of basis functions it more efficient than any other methods that include electron correlation effects. In this presentation we show the results of DFT calculations for the reaction of benzyne with naphthalene, C60, and nanotube models. We compare energies for [2+2] and [2+4] cycloaddition products. The preferred products for the naphthalene and C60 reactions have been determined by experiment and, thus, these cases serve as a validation of our quantum chemical approach. We also compare the DFT and Brenner potential results. Finally we can predict the likelihood of reaction between benzyne and nanotubes.

Jaffe, Richard↗

Development of an Intelligent Videogrammetric Wind Tunnel Measurement System

A videogrammetric technique developed at NASA Langley Research Center has been used at five NASA facilities at the Langley and Ames Research Centers for deformation measurements on a number of sting mounted and semispan models. These include high-speed research and transport models tested over a wide range of aerodynamic conditions including subsonic, transonic, and supersonic regimes. The technique, based on digital photogrammetry, has been used to measure model attitude, deformation, and sting bending. In addition, the technique has been used to study model injection rate effects and to calibrate and validate methods for predicting static aeroelastic deformations of wind tunnel models. An effort is currently underway to develop an intelligent videogrammetric measurement system that will be both useful and usable in large production wind tunnels while providing accurate data in a robust and timely manner. Designed to encode a higher degree of knowledge through computer vision, the system features advanced pattern recognition techniques to improve automated location and identification of targets placed on the wind tunnel model to be used for aerodynamic measurements such as attitude and deformation. This paper will describe the development and strategy of the new intelligent system that was used in a recent test at a large transonic wind tunnel.

Graves, Sharon S.↗