Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

Geng, Rong-Li↗

ZnCr and ZnNb Cold Spray Coatings

Novel cold spray zinc-based alloy coatings have been investigated for corrosion protection of API 5L low carbon steel pipelines used in transporting natural gas. These different zinc alloy coatings are designed for use to help prevent internal corrosion and improve the lifespan of steel pipelines via sacrificial anodic protection. The corrosion behavior of these cold deposited zinc alloy coatings was investigated in CO2 saturated 3.5 wt.% NaCl solutions under simulated natural gas pipeline conditions. Electrochemical tests were conducted at 25 and 40 °C to determine the polarization resistance and galvanic current between each coating and the steel substrate in the galvanic couple. Tests were conducted at atmospheric, 1 bar, pressure. The results indicate that use of these coatings has the potential to increase the lifespan of steel pipelines above what a zinc coating alone could provide.

Teeter, Lucas↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

Cold Crucible Induction Melting Technology for Vitrification of High Level Waste: Development and Status in India

Cold crucible induction melting is globally emerging as an alternative technology for the vitrification of high level radioactive waste. The new technology offers several advantages such as high temperature availability with long melter life, high waste loading, high specific capacity etc. Based on the laboratory and bench scale studies, an engineering scale cold crucible induction melter was locally developed in India. The melter was operated continuously to assess its performance. The electrical and thermal efficiencies were found to be in the range of 70-80 % and 10-20 % respectively. Glass melting capacities up to 200 kg m{sup -2} hr{sup -1} were accomplished using the ESCCIM. Industrially adaptable melter operating procedures for start-up, melting and pouring operations were established (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility Evaluation and Retrofit Plan for Cold Crucible Induction Melter Deployment in the Defense Waste Processing Facility at Savannah River Site

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 kHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 deg. C to 200 deg. C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 deg. C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualification of CASMO5 / SIMULATE-3K against the SPERT-III E-core cold start-up experiments

SIMULATE-3K is a three-dimensional kinetic code applicable to LWR Reactivity Initiated Accidents. S3K has been used to calculate several international recognized benchmarks. However, the feedback models in the benchmark exercises are different from the feedback models that SIMULATE-3K uses for LWR reactors. For this reason, it is worth comparing the SIMULATE-3K capabilities for Reactivity Initiated Accidents against kinetic experiments. The Special Power Excursion Reactor Test III was a pressurized-water, nuclear-research facility constructed to analyze the reactor kinetic behavior under initial conditions similar to those of commercial LWRs. The SPERT III E-core resembles a PWR in terms of fuel type, moderator, coolant flow rate, and system pressure. The initial test conditions (power, core flow, system pressure, core inlet temperature) are representative of cold start-up, hot start-up, hot standby, and hot full power. The qualification of S3K against the SPERT III E-core measurements is an ongoing work at Studsvik. In this paper, the results for the 30 cold start-up tests are presented. The results show good agreement with the experiments for the reactivity initiated accident main parameters: peak power, energy release and compensated reactivity. Predicted and measured peak powers differ at most by 13%. Measured and predicted reactivity compensations at the time of the peak power differ less than 0.01 $. Predicted and measured energy release differ at most by 13%. All differences are within the experimental uncertainty. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cold crucible deployment in La Hague facility: the feedback from the first four years of operation - 15119

In April 2010, a Cold Crucible Induction Melter (CCIM) started hot operation for the first time ever in an existing very high active facility (R7) at La Hague. This was the culmination of more than two decades of R and D involving progressive process and technological development. The industrial deployment included extensive cleaning of the hot cell, removal of the previous melter, exchange of several mechanical and process components in the cell, and implementation of the various additional utilities and components necessary for operation of the new CCIM. The design and implementation phases for this deployment were described in a previous paper at WM. The CCIM has now been operated for more than four years, essentially processing active effluents from D and D operations and high-level liquid waste from reprocessed U-Mo-Sn-Al spent fuel. During this period, many data have been collected to confirm the process parameters that were defined during the qualification of this innovating process. Even if some difficulties occurred, the experience of the operating teams with the support of engineering and R and D allow managing them. This paper presents the start-up methodology and history of the cold crucible deployment in La Hague facility with the feedback from the first years of operation. The production records with the different liquid solutions treated in the process are itemized. The lessons learned during the first four years of operation of the CCIM are presented with the difficulties encountered and the solutions implemented, emphasizing the benefits of a close integration between RD, engineering, and operation teams. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ Cold-Spray Repair of Environmental Mission Infrastructure for Component Life Extension - 19424

Cold spray offers a potential option for performing in situ repair of U.S. Department of Energy (DOE) complex infrastructure critical to the Office of Environmental Management cleanup mission. Application to the DOE complex has the potential to reduce cost, schedule, and safety risk impacts associated with component failures and would negate the need to procure and construct replacement infrastructure. A concept and technical basis are presented for developing remotely deployable cold-spray systems for performing in situ repairs in hazardous environments such as nuclear waste tanks, piping, and process vessels to extend component service life or return critical infrastructure to service. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preserving the Mound Laboratory Legacy-The Mound Cold War Discovery Center - 19550

The Mound Cold War Discovery Center (MCWDC) opened at the former DOE Mound Laboratory in Miamisburg, Ohio, on April 23, 2018, approximately three years after the US Department of Energy (DOE) Office of Legacy Management, Dayton History, the Mound Science and EnergyMuseum Association (MSEMA), and the Mound Development Corporation signed the Mound Educational Center Memorandum of Agreement (MOA). This MOA designated each party's responsibilities for the facility and laid the groundwork for DOE to enter into a Cooperative Agreement with Dayton History to design, build, and perform initial operations of the educational center. Dayton History is a nonprofit organization that operates several historical facilities in Montgomery County, Ohio. The Mound Development Corporation is the nonprofit organization that operates the Mound Business Park, privately owned property previously associated with the former DOE Mound Laboratory. The US Atomic Energy Commission began operations at the Mound Laboratory in 1948 as an integrated research, development, and production facility that supported the nation's weapons and energy programs. In October 2015, DOE entered into a five-year Cooperative Agreement with Dayton History to preserve, protect, and make accessible legacy records and information about the history of the Mound site through the development of an educational center. Years One and Two were for design and construction, respectively. Years Three through Five were for operation of the new center. The new center, located in a building owned by the Mound Development Corporation, would carry on the mission started by the MSEMA, a nonprofit organization started by former Mound site employees more than 15 years ago after DOE mission work ended at the site. As part of the cooperative agreement, Dayton History is responsible for creating interactive displays and exhibits to draw, entertain, and educate the public on the Mound site's significant contributions to the protection of the nation; developing educational programs; and initiating marketing strategies for the long-term sustainability of the educational center. In 2016, parties to the MOA officially named the facility the Mound Cold War Discovery Center. The MCWDC was designed to preserve the history of the Mound site through effective, entertaining, and efficient communication of the history of the Mound Laboratory; the site's legacy to the US weapons production complex and space exploration program; and promote understanding of what has happened at the site since DOE mission work ended, including environmental cleanup under the Comprehensive Environmental Response, Compensation, and Liability Act and the regulator-approved end state of industrial/commercial land use with associated institutional controls. The cooperative agreement requires Dayton History to develop and implement marketing strategies to support the long-term sustainability of the MCWDC at the Mound site. Dayton History will submit a report after the first year of operation and every year thereafter during the period of the cooperative agreement. These reports will describe and status efforts to obtain sustainability and offer for consideration any operational changes, corrections, or suggestions that may improve the potential for sustainability. Prior to the end of the cooperative agreement, a sustainability assessment decision will be made by DOE to determine whether the MCWDC has enough community interest to financially sustain itself at the Mound site. The status of the MCWDC Legacy Fund established by Dayton History will be considered in DoE's assessment determination. If DOE determines that the MCWDC is not sustainable at the Mound site, the exhibits will be relocated to Carillon Historical Park in Dayton, with the five key exhibits that were predetermined in the MOA to be placed on permanent display, thereby maintaining the legacy of the Mound site. Dayton History is required to submit a final closeout report at the end of Year Five of the cooperative agreement. The report will describe all activities completed under the agreement, provide an assessment of how project goals were achieved or not achieved, and describe how the legacy of the site will be preserved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE - 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined Joule heated melters. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed Joule Heated Melter, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations.

36 MATERIALS SCIENCE↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Single-band Cold Mass Support System for the MICE Superconducting Coupling Magnet

The cooling channel of the Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils, which are magnetically hooked together and contained in seven modules. The operations of a pair of MICE superconducting coupling magnets are affected directly by the other solenoid coils in the MICE channel. In order to meet the stringent requirement for the magnet center and axis azimuthal angle at 4.2 K, a self-centered tension-band cold mass support system with intermediate thermal interruption was applied for the MICE superconducting coupling magnet. The physical center of the magnet does not change as it is cooled down from 300 K to 4.2 K using this support system. This paper analyzed and calculated force loads on the coupling magnet under various operation modes of the MICE cooling channel. The performance parameters of a single-band cold mass support system were calculated also.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cold Nuclear Matter Effects on Quarkonium Production from the SPS to the LHC

The J/{psi}, {psi}{prime} and {chi}c production yields are expected to be considerably suppressed in a quark-gluon plasma. In addition, the {Gamma} states, with the possible exception of the 1S state, are also expected to be suppressed. However, in proton-nucleus collisions all the quarkonium production cross sections scale less than linearly with the number of binary nucleon-nucleon collisions. These 'cold nuclear matter' effects need to be accounted for before signals of the high density QCD medium can be identified in the measurements made in nucleus-nucleus collisions. There are two cold nuclear matter effects important for midrapidity quarkonium production: 'nuclear absorption', a final-state effect, and shadowing, an initial-state effect. We characterize these effects and study their energy and rapidity dependence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conserved synteny at the protein family level reveals genes underlying Shewanella species' cold tolerance and predicts their novel phenotypes

In spite of a rapid growth in the number of sequenced bacteria and significant progress in the annotation of their genomes, current computational technologies are limited in their capability to associate the genotype of a sequenced bacterial organism with its phenotypic traits. We evaluated two novel, complimentary approaches that can facilitate this task. They are based on correlation between the numbers of the trait-specific protein families or Pfam domains and a quantitative characteristic of the phenotypic trait among different bacterial species. Our first, a top-down approach, involves quantification and comparison of a higher-level characteristic, a bacterial phenotype, to reveal genomic characteristics and specific genes related to the phenotype. The second, a bottom-up approach, predicts phenotypes by quantification of molecular functions in the genomes of closely related bacterial species and by following pair-wise correlation of the molecular functions enrichments and their network clustering. The approach is implemented using network analysis tools. The approaches were validated by a comparison of 19 sequenced Shewanella species. Using the first approach, we were able to identify specific domains and gene clusters associated with cold tolerance of these mesophilic species and to predict some novel cellular mechanisms underlying the phenotype. We find that in three tested species both cold and salt tolerance relate to presence in their genome of a specific Na+/H+ antiporter. By using the second approach we identified genomic clusters predicting several environmentally relevant phenotypes in the newly sequenced Shewanella species including degradation of aromatic compounds by an aerobic hybrid pathway, utilization of ethanolamine, and arsenic and copper resistance. Results of the study confirm validity of the approaches and their utility for (i) computational predictions of phenotypic traits in the sequenced organisms, (ii) revealing genomic determinants of known complex phenotypes, (iii) orthologs prediction, and for (iv) discovery of function of unknown domains and hypothetical proteins.

59 BASIC BIOLOGICAL SCIENCES↗