Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Performance analysis of absorption thermal energy storage for distributed energy systems

In recent years, distributed energy systems (DES) have attracted worldwide attention. Distributed generation unit (DG) in DES usually works under part load during night, which results in low efficiency and the waste heat of DG cannot be fully utilized. This study proposes a novel absorption thermal energy storage system together with electric energy storage for distributed energy systems. The proposed absorption thermal energy storage system which is a combination of absorption chiller and liquid storage tanks, has a higher energy storage density. During off-peak hours, the extra electricity of DG can be used by electric chillers (EC) and the extra waste heat of DG is stored by the proposed absorption thermal energy storage system. The stored thermal energy is released in peak hours to meet the cooling loads of buildings. A case study of DES in a campus under cooling-dominated climate is conducted to evaluate the performance of the proposed system. The results in a typical summer day indicate that the DG utilization rate increases from 80% to 92.9%, meanwhile the required capacities of electric chillers can be obviously reduced. The operating cost of DES also reduces by 12.9% compared with the DES without energy storage. Through appropriate operation strategy, off-the-grid operation for DES can be achieved without energy waste by applying the proposed energy storage method.

Wang, Lingshi↗

System analysis for the Huntsville Operation Support Center distributed computer system

A simulation model of the NASA Huntsville Operational Support Center (HOSC) was developed. This simulation model emulates the HYPERchannel Local Area Network (LAN) that ties together the various computers of HOSC. The HOSC system is a large installation of mainframe computers such as the Perkin Elmer 3200 series and the Dec VAX series. A series of six simulation exercises of the HOSC model is described using data sets provided by NASA. The analytical analysis of the ETHERNET LAN and the video terminals (VTs) distribution system are presented. An interface analysis of the smart terminal network model which allows the data flow requirements due to VTs on the ETHERNET LAN to be estimated, is presented.

Ingels, F. M.↗

Resident database interfaces to the DAVID system, a heterogeneous distributed database management system

A methodology for building interfaces of resident database management systems to a heterogeneous distributed database management system under development at NASA, the DAVID system, was developed. The feasibility of that methodology was demonstrated by construction of the software necessary to perform the interface task. The interface terminology developed in the course of this research is presented. The work performed and the results are summarized.

Moroh, Marsha↗

An Examination of the Effect of Boundary Layer Ingestion on Turboelectric Distributed Propulsion Systems

A Turboelectric Distributed Propulsion (TeDP) system differs from other propulsion systems by the use of electrical power to transmit power from the turbine to the fan. Electrical power can be efficiently transmitted over longer distances and with complex topologies. Also the use of power inverters allows the generator and motors speeds to be independent of one another. This decoupling allows the aircraft designer to place the core engines and the fans in locations most advantageous for each. The result can be very different installation environments for the different devices. Thus the installation effects on this system can be quite different than conventional turbofans where the fan and core both see the same installed environments. This paper examines a propulsion system consisting of two superconducting generators, each driven by a turboshaft engine located so that their inlets ingest freestream air, superconducting electrical transmission lines, and an array of superconducting motor driven fan positioned across the upper/rear fuselage area of a hybrid wing body aircraft in a continuous nacelle that ingests all of the upper fuselage boundary layer. The effect of ingesting the boundary layer on the design of the system with a range of design pressure ratios is examined. Also the impact of ingesting the boundary layer on off-design performance is examined. The results show that when examining different design fan pressure ratios it is important to recalculate of the boundary layer mass-average Pt and MN up the height for each inlet height during convergence of the design point for each fan design pressure ratio examined. Correct estimation of off-design performance is dependent on the height of the column of air measured from the aircraft surface immediately prior to any external diffusion that will flow through the fan propulsors. The mass-averaged Pt and MN calculated for this column of air determine the Pt and MN seen by the propulsor inlet. Since the height of this column will change as the amount of air passing through the fans change as the propulsion system is throttled, and since the mass-average Pt and MN varies by height, this capture height must be recalculated as the airflow through the propulsor is varied as the off-design performance point is converged.

Felder, James L.↗

Cascade energy optimization for waste heat recovery in distributed energy systems

The efficiency of distributed energy systems can be significantly increased through waste heat recovery from industry or power generation. The technologies used for this process are typically dependent on the quality and temperature grades of waste heat. To maximize the efficiency of cascade heat utilization, it is important to optimize the choice of waste heat recovery technologies and their operation. Here, a detailed mixed integer linear programming optimization model is proposed for waste heat recovery in a district-scale microgrid. The model can distinguish waste heat quality for planning and operation optimization of distributed energy systems. Heat utilization technologies are formulated in this developed model and categorized in different temperature grades. The developed model is validated using four typical cases under different settings of system operation and business models. It is found that the optimization model, by distinguishing waste heat temperature, can increase energy cost savings by around 5%, compared to models that do not consider waste heat temperature grades. Additionally, the results indicate that the developed model can provide more realistic configuration and technologies dispatch.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Byzantine-Fault Tolerant Self-Stabilizing Protocol for Distributed Clock Synchronization Systems

Embedded distributed systems have become an integral part of safety-critical computing applications, necessitating system designs that incorporate fault tolerant clock synchronization in order to achieve ultra-reliable assurance levels. Many efficient clock synchronization protocols do not, however, address Byzantine failures, and most protocols that do tolerate Byzantine failures do not self-stabilize. Of the Byzantine self-stabilizing clock synchronization algorithms that exist in the literature, they are based on either unjustifiably strong assumptions about initial synchrony of the nodes or on the existence of a common pulse at the nodes. The Byzantine self-stabilizing clock synchronization protocol presented here does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The proposed protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period. Proofs of the correctness of the protocol as well as the results of formal verification efforts are reported.

Malekpour, Mahyar R.↗

A Byzantine-Fault Tolerant Self-Stabilizing Protocol for Distributed Clock Synchronization Systems

Embedded distributed systems have become an integral part of safety-critical computing applications, necessitating system designs that incorporate fault tolerant clock synchronization in order to achieve ultra-reliable assurance levels. Many efficient clock synchronization protocols do not, however, address Byzantine failures, and most protocols that do tolerate Byzantine failures do not self-stabilize. Of the Byzantine self-stabilizing clock synchronization algorithms that exist in the literature, they are based on either unjustifiably strong assumptions about initial synchrony of the nodes or on the existence of a common pulse at the nodes. The Byzantine self-stabilizing clock synchronization protocol presented here does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The proposed protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period. Proofs of the correctness of the protocol as well as the results of formal verification efforts are reported.

Malekpour, Mahyar R.↗

Combined Transmission and Distribution Test System to Study High Penetration of Distributed Solar Generation

Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.

Samaan, Nader A.↗

Finite Control in Underdamped Distributed Parameter Systems

Specifically, a class of distributed parameter systems is defined using Hilbert space methods based on a partial differential equation model of a structure. In this space a simple, easy to check definition of underdamping is constructed based on the well known single degree of freedom concept of critical damping. It is then shown that if a given distributed parameter system satisfies this definition, each mode of the modal expansion of the solution is in fact an underdamped function of time. It is noted that a distributed parameter system which is underdamped is also uniformly exponentially stable. By appealing to the work of Gibson, a finite dimensional model of the system will yield satisfactory control laws. Furthermore, it is shown that the assumption of the underdamping also allows straightforward computation of rough bounds on the magnitude of the unmodeled or residual modes for a modal truncation scheme. Hence, underdamped systems are precisely that class of distributed parameter systems which are not likely to have spillover problems and which will yield convergence of finite dimensional control laws to control laws which are optimal for the full distributed parameter model of the system.

Inman, D. J.↗

The unified data system - A distributed processing network for control and data handling on a spacecraft

This paper presents the results obtained in a continuing investigation of real-time distributed processing systems which is being conducted at the Jet Propulsion Laboratory. A distributed processor architecture has been developed for control and data handling on a planetary spacecraft. This system, designated the Unified Data System, has been implemented in a feasibility breadboard. The following aspects of the Unified Data System are described: (1) standardized building block elements and their configuration into microprocessor modules, (2) a highly redundant bus structure which connects the various modules and facilitates intercommunications with minimal software support, (3) the structure of software within the individual modules and its coordination between modules, and (4) the mechanisms by which fault-tolerance can be implemented within the network. Through the attributes of multilevel standardization, simplicity, and flexibility, this system is expected to result in significant cost savings to future spacecraft missions.

Rennels, D. A.↗

System Analysis for the Huntsville Operation Support Center, Distributed Computer System

HOSC as a distributed computing system, is responsible for data acquisition and analysis during Space Shuttle operations. HOSC also provides computing services for Marshall Space Flight Center's nonmission activities. As mission and nonmission activities change, so do the support functions of HOSC change, demonstrating the need for some method of simulating activity at HOSC in various configurations. The simulation developed in this work primarily models the HYPERchannel network. The model simulates the activity of a steady state network, reporting statistics such as, transmitted bits, collision statistics, frame sequences transmitted, and average message delay. These statistics are used to evaluate such performance indicators as throughout, utilization, and delay. Thus the overall performance of the network is evaluated, as well as predicting possible overload conditions.

Ingels, F. M.↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for evaluating electrolyte wetting and distribution

Systems and techniques for measuring process characteristics including electrolyte distribution in a battery cell. A non-destructive method for analyzing a battery cell includes determining acoustic features at two or more locations of the battery cell, the acoustic features based on one or more of acoustic signals travelling through at least one or more portions of the battery cell during one or more points in time or responses to the acoustic signals obtained during one or more points in time, wherein the one or more points in time correspond to one or more stages of electrolyte distribution in the battery cell. One or more characteristics of the battery cell are determined based on the acoustic features at the two or more locations of the battery cell.

Dou, Shan↗

Design and Benchmarking of a Network-In-the-Loop Simulation for Use in a Hardware-In-the-Loop System

Distributed engine control (DEC) systems alter aircraft engine design constraints because of fundamental differences in the input and output communication between DEC and centralized control architectures. The change in the way communication is implemented may create new optimum engine-aircraft configurations. This paper continues the exploration of digital network communication by demonstrating a Network-In-the-Loop simulation at the NASA Glenn Research Center. This simulation incorporates a real-time network protocol, the Engine Area Distributed Interconnect Network Lite (EADIN Lite), with the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software. The objective of this study is to assess digital control network impact to the control system. Performance is evaluated relative to a truth model for large transient maneuvers and a typical flight profile for commercial aircraft. Results show that a decrease in network bandwidth from 250 Kbps (sampling all sensors every time step) to 40 Kbps, resulted in very small differences in control system performance.

Networked Systems↗

An overview of the EOSDIS V0 information management system: Lessons learned from the implementation of a distributed data system

The EOSDIS Version 0 system, released in July, 1994, is a working prototype of a distributed data system. One of the purposes of the V0 project is to take several existing data systems and coordinate them into one system while maintaining the independent nature of the original systems. The project is a learning experience and the lessons are being passed on to the architects of the system which will distribute the data received from the planned EOS satellites. In the V0 system, the data resides on heterogeneous systems across the globe but users are presented with a single, integrated interface. This interface allows users to query the participating data centers based on a wide set of criteria. Because this system is a prototype, we used many novel approaches in trying to connect a diverse group of users with the huge amount of available data. Some of these methods worked and others did not. Now that V0 has been released to the public, we can look back at the design and implementation of the system and also consider some possible future directions for the next generation of EOSDIS.

Ryan, Patrick M.↗

Blockchain for Fault-Tolerant Grid Operations

Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗