Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

SU-E-J-254: Utility of Pinnacle Dynamic Planning Module Utilizing Deformable Image Registration in Adaptive Radiotherapy

Purpose For certain highly conformal treatment techniques, changes in patient anatomy due to weight loss and/or tumor shrinkage can result in significant changes in dose distribution. Recently, the Pinnacle treatment planning system added a Dynamic Planning module utilizing Deformable Image Registration (DIR). The objective of this study was to evaluate the effectiveness of this software in adapting to altered anatomy and adjusting treatment plans to account for it. Methods We simulated significant tumor response by changing patient thickness and altered chin positions using a commercially-available head and neck (H and N) phantom. In addition, we studied 23 CT image sets of fifteen (15) patients with H and N tumors and eight (8) patients with prostate cancer. In each case, we applied deformable image registration through Dynamic Planning module of our Pinnacle Treatment Planning System. The dose distribution of the original CT image set was compared to the newly computed dose without altering any treatment parameter. Result was a dose if we did not adjust the plan to reflect anatomical changes. Results For the H and N phantom, a tumor response of up to 3.5 cm was correctly deformed by the Pinnacle Dynamic module. Recomputed isodose contours on new anatomies were within 1 mm of the expected distribution. The Pinnacle system configuration allowed dose computations resulting from original plans on new anatomies without leaving the planning system. Original and new doses were available side-by-side with both CT image sets. Based on DIR, about 75% of H and N patients (11/15) required a re-plan using new anatomy. Among prostate patients, the DIR predicted near-correct bladder volume in 62% of the patients (5/8). Conclusions The Dynamic Planning module of the Pinnacle system proved to be an accurate and useful tool in our ability to adapt to changes in patient anatomy during a course of radiotherapy.

60 APPLIED LIFE SCIENCES↗

A Fano cavity test for Monte Carlo proton transport algorithms

Purpose: In the scope of reference dosimetry of radiotherapy beams, Monte Carlo (MC) simulations are widely used to compute ionization chamber dose response accurately. Uncertainties related to the transport algorithm can be verified performing self-consistency tests, i.e., the so-called “Fano cavity test.” The Fano cavity test is based on the Fano theorem, which states that under charged particle equilibrium conditions, the charged particle fluence is independent of the mass density of the media as long as the cross-sections are uniform. Such tests have not been performed yet for MC codes simulating proton transport. The objectives of this study are to design a new Fano cavity test for proton MC and to implement the methodology in two MC codes: Geant4 and PENELOPE extended to protons (PENH). Methods: The new Fano test is designed to evaluate the accuracy of proton transport. Virtual particles with an energy ofE{sub 0} and a mass macroscopic cross section of (Σ)/(ρ) are transported, having the ability to generate protons with kinetic energy E{sub 0} and to be restored after each interaction, thus providing proton equilibrium. To perform the test, the authors use a simplified simulation model and rigorously demonstrate that the computed cavity dose per incident fluence must equal (ΣE{sub 0})/(ρ) , as expected in classic Fano tests. The implementation of the test is performed in Geant4 and PENH. The geometry used for testing is a 10 × 10 cm{sup 2} parallel virtual field and a cavity (2 × 2 × 0.2 cm{sup 3} size) in a water phantom with dimensions large enough to ensure proton equilibrium. Results: For conservative user-defined simulation parameters (leading to small step sizes), both Geant4 and PENH pass the Fano cavity test within 0.1%. However, differences of 0.6% and 0.7% were observed for PENH and Geant4, respectively, using larger step sizes. For PENH, the difference is attributed to the random-hinge method that introduces an artificial energy straggling if step size is not small enough. Conclusions: Using conservative user-defined simulation parameters, both PENH and Geant4 pass the Fano cavity test for proton transport. Our methodology is applicable to any kind of charged particle, provided that the considered MC code is able to track the charged particle considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Dual Alpha/Gamma Imaging Tool to Manage Decommissioning Operations

The knowledge of the radiological state of a nuclear plant under decommissioning is a key factor at any stage of the project: from the initial characterization (to define the best scenario and the main dismantling steps), during the monitoring of the decontamination operations, for the waste management and, last but not least, for the final controls. During a facility's operation, a clear view of the process radiological level is equally necessary, in order to plan maintenance scheduling and optimize interventions by personnel. Radiation protection teams generally ensure worker radiological safety, and also supply dose mappings for each of the areas associated with typical spectra. In most cases, this mapping does not give enough information to be used as input data when preparing maintenance or clean-up work. With advances in activity modeling calculation codes (using 3D), the way measurements are made to recover the best input radiological data on site is a key factor. Nuclear instrumentation is still in progress and the evolution of the technologies and software allow us to get imaging information in real time. The gamma camera is going to evolve and to become more compact and more sensitive. New portable gamma cameras have to be tested under high level dose rate. The alpha camera is also evolving: from the first prototype tested on site to solar blind alpha camera (to reduce the influence of light) to the new dual alpha/gamma prototype. (authors)

42 ENGINEERING↗

The importance of delayed neutron precursors in gamma dose calculations for activated primary heat exchanger components in the Molten Salt Breeder Reactor

The Molten Salt Reactor (MSR) Multiphysics Applications technical area in the Nuclear Energy Advanced Modeling and Simulation program has supported the development of 3D Monte Carlo models of the Molten Salt Breeder Reactor (MSBR) over the last couple of years. This MSBR model was previously run with the Shift Monte Carlo code to perform radiation shielding calculations in the reactor cell area. The MSBR is a 2250 MWth (1000 MWe) liquid-fueled molten salt reactor design developed at Oak Ridge National Laboratory in the 1970s. Determining the source terms from activated primary heat exchanger (HX) components is important because delayed and prompt neutron fluxes incident on these components affect the dose rate in the primary HX maintenance areas. This information can be used in the development of remote handling procedures required during shutdown for maintenance. A methodology has been developed and is proposed in this paper to quantify the activated source term from the primary HX components as a result of the movement of the delayed neutron precursors in flowing primary fuel salt through the primary HXs in the MSBR. The goal of this research is to evaluate the gamma dose rates in the maintenance hatches above the primary HX using the activated HX source terms. The study showed that the gamma dose rates are approximately two orders of magnitudes higher when accounting for the neutron activation from the movement of delayed neutron precursors through the HXs than when flowing fuel is not considered. Thus, the movement of delayed neutron precursors must be taken into account for accurately predicting the neutron activation of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-C-BRC-07: Parametrized GPU Accelerated Electron Monte Carlo Second Check

Purpose: I am presenting a parameterized 3D GPU accelerated electron Monte Carlo second check program. Method: I wrote the 3D grid dose calculation algorithm in CUDA and utilized an NVIDIA GeForce GTX 780 Ti to run all of the calculations. The electron path beyond the distal end of the cone is governed by four parameters: the amplitude of scattering (AMP), the mean and width of a Gaussian energy distribution (E and α), and the percentage of photons. In my code, I adjusted all parameters until the calculated PDD and profile fit the measured 10×10 open beam data within 1%/1mm. I then wrote a user interface for reading the DICOM treatment plan and images in Python. In order to verify the algorithm, I calculated 3D dose distributions on a variety of phantoms and geometries, and compared them with the Eclipse eMC calculations. I also calculated several patient specific dose distributions, including a nose and an ear. Finally, I compared my algorithm’s computation times to Eclipse’s. Results: The calculated MU for all of the investigated geometries agree with the TPS within the TG-114 action level of 5%. The MU for the nose was < 0.5 % different while the MU for the ear at 105 SSD was ∼2 %. Calculation times for a 12MeV 10×10 open beam ranged from 1 second for a 2.5 mm grid resolution with ∼15 million particles to 33 seconds on a 1 mm grid with ∼460 million particles. Eclipse calculation runtimes distributed over 10 FAS workers were 9 seconds to 15 minutes respectively. Conclusion: The GPU accelerated second check allows quick MU verification while accounting for patient specific geometry and heterogeneity.

60 APPLIED LIFE SCIENCES↗

Algorithmic Improvements to MCNP5 for High-Resolution Fusion Neutronics Analyses

Neutronics analyses of the ITER experimental fusion reactor rely on increasingly complex geometry models and estimates of energy-dependent neutron flux and radiation dose-rate distributions generated at ever higher resolutions. There are significant practical challenges with applying the Monte Carlo N-Particle (MCNP) continuous-energy transport code to high-resolution analyses. For models consisting of more than 100 000 surfaces and cells, geometry initialization can take several hours, thus slowing down model integration and transport analysis efforts. In multithreaded simulations, the amount of memory consumed by superimposed mesh tally data increases in proportion to the number of threads. This behavior limits either the tally resolution or the number of processor cores that can be utilized in the simulation. This paper describes algorithmic improvements that were implemented in a modified version of MCNP5 to overcome these limitations. These improvements are referred to as the Oak Ridge National Laboratory Transformative Neutronics (ORNL-TN) upgrade. Here, a comparison of the performance and memory usage of both MCNP5 and ORNL-TN on several relevant fusion neutronics models is presented. In these tests and in actual high-resolution neutronics analyses, ORNL-TN reduces geometry processing times from hours to a few seconds and increases in-memory mesh tally capacity from the order of 10 8 to 10 10 space-energy bins.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Does administering iodine in radiological procedures increase patient doses?

Purpose: The authors investigated the changes in the pattern of energy deposition in tissue equivalent phantoms following the introduction of iodinated contrast media. Methods: The phantom consisted of a small “contrast sphere,” filled with water or iodinated contrast, located at the center of a 28 cm diameter water sphere. Monte Carlo simulations were performed using MCNP5 codes, validated by simulating irradiations with analytical solutions. Monoenergetic x-rays ranging from 35 to 150 keV were used to simulate exposures to spheres containing contrast agent with iodine concentrations ranging from 1 to 100 mg/ml. Relative values of energy imparted to the contrast sphere, as well as to the whole phantom, were calculated. Changes in patterns of energy deposition around the contrast sphere were also investigated. Results: Small contrast spheres can increase local absorbed dose by a factor of 13, but the corresponding increase in total energy absorbed was negligible (<1%). The highest localized dose increases were found to occur at incident photon energies of about 60 keV. For a concentration of about 10 mg/ml, typical of clinical practice, localized absorbed doses were generally increased by about a factor of two. At this concentration of 10 mg/ml, the maximum increase in total energy deposition in the phantom was only 6%. These simulations demonstrated that increases in contrast sphere doses were offset by corresponding dose reductions at distal and posterior locations. Conclusions: Adding iodine can result in values of localized absorbed dose increasing by more than an order of magnitude, but the total energy deposition is generally very modest (i.e., <10%). Their data show that adding iodine primarily changes the pattern of energy deposition in the irradiated region, rather than increasing patient doses per se.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factors were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.

07 ISOTOPE AND RADIATION SOURCES↗

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Generation of a novel phase-space-based cylindrical dose kernel for IMRT optimization

Purpose: Improving dose calculation accuracy is crucial in intensity-modulated radiation therapy (IMRT). We have developed a method for generating a phase-space-based dose kernel for IMRT planning of lung cancer patients. Methods: Particle transport in the linear accelerator treatment head of a 21EX, 6 MV photon beam (Varian Medical Systems, Palo Alto, CA) was simulated using the EGSnrc/BEAMnrc code system. The phase space information was recorded under the secondary jaws. Each particle in the phase space file was associated with a beamlet whose index was calculated and saved in the particle's LATCH variable. The DOSXYZnrc code was modified to accumulate the energy deposited by each particle based on its beamlet index. Furthermore, the central axis of each beamlet was calculated from the orientation of all the particles in this beamlet. A cylinder was then defined around the central axis so that only the energy deposited within the cylinder was counted. A look-up table was established for each cylinder during the tallying process. The efficiency and accuracy of the cylindrical beamlet energy deposition approach was evaluated using a treatment plan developed on a simulated lung phantom. Results: Profile and percentage depth doses computed in a water phantom for an open, square field size were within 1.5% of measurements. Dose optimized with the cylindrical dose kernel was found to be within 0.6% of that computed with the nontruncated 3D kernel. The cylindrical truncation reduced optimization time by approximately 80%. Conclusions: A method for generating a phase-space-based dose kernel, using a truncated cylinder for scoring dose, in beamlet-based optimization of lung treatment planning was developed and found to be in good agreement with the standard, nontruncated scoring approach. Compared to previous techniques, our method significantly reduces computational time and memory requirements, which may be useful for Monte-Carlo-based 4D IMRT or IMAT treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-525: Ionization Chamber Perturbation in Flattening Filter Free Beams

Purpose: Changing the characteristic of a photon beam by mechanically removing the flattening filter may impact the dose response of ionization chambers. Thus, perturbation factors of cylindrical ionization chambers in conventional and flattening filter free photon beams were calculated by Monte Carlo simulations. Methods: The EGSnrc/BEAMnrc code system was used for all Monte Carlo calculations. BEAMnrc models of nine different linear accelerators with and without flattening filter were used to create realistic photon sources. Monte Carlo based calculations to determine the fluence perturbations due to the presens of the chambers components, the different material of the sensitive volume (air instead of water) as well as the volume effect were performed by the user code egs-chamber. Results: Stem, central electrode, wall, density and volume perturbation factors for linear accelerators with and without flattening filter were calculated as a function of the beam quality specifier TPR{sub 20/10}. A bias between the perturbation factors as a function of TPR{sub 20/10} for flattening filter free beams and conventional linear accelerators could not be observed for the perturbations caused by the components of the ionization chamber and the sensitive volume. Conclusion: The results indicate that the well-known small bias between the beam quality correction factor as a function of TPR20/10 for the flattening filter free and conventional linear accelerators is not caused by the geometry of the detector but rather by the material of the sensitive volume. This suggest that the bias for flattening filter free photon fields is only caused by the different material of the sensitive volume (air instead of water)

60 APPLIED LIFE SCIENCES↗

SU-F-J-98: Improvement and Evaluation Of Deformation Image Registration On Parotid Glands During Radiation Therapy for Nasopharyngeal Cancer

Purpose: To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions. Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software (Adaptive Plan, TomoTherapy), and were edited manually if necessary. The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs. The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index (DSI). Two-tailed t-test analysis was carried out to compare the DSI changes during the course of RT. Results: For 10 patient plans, the accuracy of deformation image registration (DIR) with the rotation shift was obviously better than those without the rotation shift. The Dice scores of the ipsi- and contra-lateral parotids for with and without the rotation shifts were found to be correlated with each other [0.904±0.031 vs 0.919±0.030 (p<0.001); 0.900±0.031 vs 0.910±0.032 (p<0.001)]. The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT. The DSI values between the first and last fraction were 0.932±0.020 vs 0.899±0.030 in 10 patient plans. Conclusion: DIR was successfully improved using the strategic innovation for ART. And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225).

60 APPLIED LIFE SCIENCES↗

Final Review of Safety Assessment Issues at Savannah River Site, August 2011

At the request of Savannah River Nuclear Solutions (SRNS) management, a review team composed of experts in atmospheric transport modeling for environmental radiation dose assessment convened at the Savannah River Site (SRS) on August 29-30, 2011. Though the meeting was prompted initially by suspected issues related to the treatment of surface roughness inherent in the SRS meteorological dataset and its treatment in the MELCOR Accident Consequence Code System Version 2 (MACCS2), various topical areas were discussed that are relevant to performing safety assessments at SRS; this final report addresses these topical areas.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-748: Theoretical Investigation On Using High Energy Proton Beam for Total-Body-Irradiation

Purpose: The broad-slow-rising entrance dose region proximal to the Bragg peak made by a mono-energetic proton beam could potentially be used for total body irradiation (TBI). Due to the quasi-uniform dose deposition, customized thickness compensation may not be required to deliver a uniform dose to patients with varied thickness. We investigated the possibility, efficacy, and hardware requirement to use such proton beam for TBI. Methods: A wedge shaped water phantom with thickness varying from 2 cm to 40 cm was designed to mimic a patient. Geant4 based Monte Carlo code was used to simulate broad mono-energetic proton beams with energy ranging from 250 MeV to 300 MeV radiating the phantom. A 6 MV photon with 1 cm water equivalent build-up used for conventional TBI was also calculated. A paired-opposing beam arrangement with no thickness compensation was used to generate TBI plans for all beam energies. Dose from all particles were scored on a grid size of 2 mm{sup 3}. Dose uniformity across the phantom was calculated to evaluate the plan. The field size limit and the dose uniformity of Mevion S250 proton system was examined by using radiochromic films placed at extended treatment distance with the open large applicator and 90° gantry angle. Results: To achieve a maximum ± 7.5% dose variation, the largest patient thickness variation allowed for 250 MeV, 275 MeV, and 300 MeV proton beams were 27.0 cm, 34.9 cm and 36.7 cm. The value for 6 MV photon beam was only 8.0 cm to achieve the same dose variation. With open gantry, Mevion S250 system allows 5 m source-to-surface distance producing an expected 70 cm{sup 2} field size. Conclusion: Energetic proton beam can potentially be used to deliver TBI. Treatment planning and delivery would be much simple since no thickness compensation is required to achieve a uniform dose distribution.

60 APPLIED LIFE SCIENCES↗