Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Architecture of a Residential Solid State Power Substation (SSPS) Node

High integration rates of new loads and distributed generation at the edge of the grid are posing new challenges. However, existing smart power electronic systems are not designed to coordinate and maximize grid support or provide multiple grid services simultaneously. This work presents the application of a solid-state power substation (SSPS) to residential systems to increase this coordination and reduce future challenges. The proposed residential SSPS is validated in simulation including power electronic converter models, feeder models, and optimization.

Krishna Moorthy, Radha↗

Microgrid Controllers : Expanding Their Role and Evaluating Their Performance

Microgrids have long been deployed to provide power to customers in remote areas as well as critical industrial and military loads. Today, they are also being proposed as grid-interactive solutions for energy-resilient communities. Such microgrids will spend most of the time operating while synchronized with the surrounding utility grid but will also be capable of separating during contingency periods due to storms or temporary disturbances such as local grid faults. Properly designed and grid-integrated microgrids can provide the flexibility, reliability, and resiliency needs of both the future grid and critical customers. These systems can be an integral part of future power system designs that optimize investments to achieve operational goals, improved reliability, and diversification of energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Findings from Design and Operation of Connected Neighborhoods

Distributed energy resources and load management are an important emerging part of smart grids. Concurrent management of homeowner preferences and utility objectives requires an intelligent negotiation strategy supported by physical infrastructure that learns, optimizes, and controls the system. While there is a wide body of research related to modelling and simulation of distributed resources, relatively little is known about their practical feasibility. One of the first attempts to address this knowledge gap was through a 62-house connected neighborhood in Alabama. This study makes one more step in advancing this knowledge through a 46-townhome demonstration neighborhood located in Atlanta, GA. It reports hardware design, system architecture, and the results from the summer experimental work. The findings are discussed in the context of earlier experience, and analysis is expanded to areas which were not the focus of earlier research.

Tsybina, Eve↗

Synchrophasor Measurements-based Events Detection Using Deep Learning

Deep learning algorithms have been developed for phasor measurement units (PMUs) analysis aiming at providing grid operators to observe and react to significant real-time changes in the grid associated with multiple factors (e.g., power generation and load variations, different type of faults, and equipment mailfunction), or for offline post-event system diagnostics. In this study, a Long Short-Term Memory (LSTM)-based deep neural network (DNN) is adopted and evaluated to identify the most appropriate model configurations for event detection and longer-term anomalous pattern extraction. The proposed DNN model shows the potential on long-term predictions with the ability to capture nonlinear and nonstationary mixture complex patterns in PMU datasets. Real-world PMU in the WECC system were used for model development and validation.

deep learning↗

Smart Grid Enabled EVSE

The combined team of GE Global Research, Federal Express, National Renewable Energy Laboratory, and Consolidated Edison has successfully achieved the established goals contained within the Department of Energy’s Smart Grid Capable Electric Vehicle Supply Equipment funding opportunity. The final program product, shown charging two vehicles in Figure 1, reduces by nearly 50% the total installed system cost of the electric vehicle supply equipment (EVSE) as well as enabling a host of new Smart Grid enabled features. These include bi-directional communications, load control, utility message exchange and transaction management information. Using the new charging system, Utilities or energy service providers will now be able to monitor transportation related electrical loads on their distribution networks, send load control commands or preferences to individual systems, and then see measured responses. Installation owners will be able to authorize usage of the stations, monitor operations, and optimally control their electricity consumption. These features and cost reductions have been developed through a total system design solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart DG Hub Resilient Solar Project Final Report

Hurricanes, unstable fossil fuel supplies and increased energy loads have revealed the vulnerability of America’s electric grids. Renewable energy has emerged as a viable option; however in order for this sector to reach its full potential it needs to be paired with storage. For example, all of the solar installations in New York City in 2014 were wired to automatically shut down during grid outages for safety reasons and lacked battery backup or other means to function during outages. Pairing solar with batteries can provide critical power needs and reduce dependency on delivered fuel. Additionally, resilient solar systems can also provide benefits outside of emergencies such as utility bill savings and grid support services. Solar+Storage needed a pathway through regulatory, policy and financial hurdles, some of which are unique to urban environments. Sustainable CUNY of the City University of New York (CUNY) formed the Smart Distributed Generation (DG) Hub to develop a strategic pathway to a resilient distributed energy system that integrates storage into resiliency planning and provide support to the grid on peak power days. Through the Smart DG Hub Resilient Solar Project, with support from the U.S. Department of Energy (DOE) as well as the New York State Energy Research and Development Authority, the New York Power Authority and private funding, Sustainable CUNY worked with project partners - including the National Renewable Energy Laboratory, Meister Consultant Group (now Cadmus), subject matter experts at utility companies, and authorities having jurisdiction - to develop a roadmap for the greater deployment of solar+storage as well as a toolkit of resources. Ultimately, in addition to the completed deliverables of multiple resources, the project established a baseline of the current policy, financial, and market landscape, and an understanding of which key areas would require further actions. The DG Hub’s collaborative platform and subject matter expertise gained through this project led directly to a new award from the NYS Energy Research & Development Authority to continue CUNY’s work in targeted areas including energy storage permitting and stakeholder education, similar to the way DOE’s prior support had sowed the initial seeds for the growth of the solar market in NYC, to the NYS market. Finally, the Resilient Solar Project helped inform the New York City (NYC) administration, leading to a significant policy development that included Mayor Bill de Blasio setting a city-wide storage goal of 100 MW by 2020, the first of any city in the country.

25 ENERGY STORAGE↗

Requirements for Robust DERMS Control and Cyber Attack Scenarios

A Distribution Management System (DMS) is responsible for monitoring and maintaining the health of a distribution grid. Common DMS applications include fault location isolation and service restoration, on-line power flow (OLPF), volt/VAR optimization (VVO), and switch order management. These systems were developed primarily in the area of top-down, unidirectional power flow, with large centralized generating plants moving electricity through the transmission grid and into the distribution grid from and thence to consumers. The recent and ongoing addition of distributed energy resources (DER) to the grid, including rooftop and community solar and wind, means that power is now flowing into the distribution grid from the edge, which complicates the functioning of the DMS. To ameliorate this problem, DMS use distributed energy resource management systems (DERMS) to control DER such as solar inverters. DERMS comprise software management tools that allow management and near real-time control of an array of DER. DERMS control devices and grid services including smart inverters, capacitor banks, on-load tap changes, voltage regulators, and customer loads.

14 SOLAR ENERGY↗

Electrical Energy Storage Factual Status Document: Resource Document for the Workshop on Basic Research Needs for Next Generation Electrical Energy Storage, March 2017

Electrical energy storage is of growing importance to energy – with increasing use in transportation and on the electrical grid. Batteries are used in all types of vehicles, but have increased in importance with the growth of hybrid and all-electric powered vehicles. For the electrical grid, batteries have a wide diversity of applications from grid stability to storage of electricity generated when the load is low so it is available when there is more demand. Distributed generation of electricity by solar panels and wind generation are also drivers for enhanced energy storage. In both industries, a key enabler will be low-cost batteries with long life, excellent safety, and superior performance. In addition to these two big markets, consumer electronics powered by rechargeable batteries continues to grow into new areas with the advent of wearable technology, internet-of-things, and virtual reality. Today’s energy storage technologies fall far short of the requirements for many of these growing applications. Because of these technology gaps, advances in energy storage are expected to play a critical role for a secure energy future. This document was produced in preparation for a Department of Energy (DOE) Office of Basic Energy Sciences Workshop titled “Basic Research Needs for Next Generation Electrical Energy Storage.” This workshop will identify key basic research directions that could provide revolutionary breakthroughs needed for meeting future requirements for electrical energy storage. This document was intended to provide a high-level assessment of current technologies used for electrical storage—focusing specifically on batteries and electrochemical capacitors—and to define requirements that are foreseen for the future application of these technologies in transportation vehicles, stationary storage applications, and consumer electronics. Thus, it provides a common background for the workshop participants and sets the technological basis for the workshop.

25 ENERGY STORAGE↗

BWR Spent Nuclear Fuel Acquisition and Testing to Support DOE-NE High Burnup Spent Fuel Data Project

The Office of Spent Fuel and Waste Disposition (SFWD) within the US Department of Energy (DOE) Office of Nuclear Energy (NE) established the Spent Fuel and Waste Science and Technology (SFWST) campaign to conduct research and development (R&D) activities related to the storage, transportation, and disposal of spent nuclear fuel (SNF) and high-level radioactive waste. The SFWST program was created within SFWD to address issues of extended or long-term SNF storage and transportation. Some near-term objectives of SFWST are to use a science-based, engineering-driven approach to: Support the enhancement of the technical bases to support the continued safe and secure dry storage of SNF for extended periods; Support the enhancement of the technical bases for retrieving SNF after extended dry storage; Support the enhancement of the technical bases for transporting high burnup (HBU) fuel and transporting low burnup fuel and HBU fuel after dry storage DOE-NE, in partnership with the Electric Power Research Institute, developed the High Burnup Spent Fuel Data Project to perform a large-scale demonstration and laboratory-scale testing of HBU pressurized water reactor (PWR) fuels (exceeding 45 gigawatt-days per metric ton of uranium [GWd/MTU]). Under this project, 25 sister rods—which are rods that have the same design, power histories, and other characteristics—were removed from assemblies at the North Anna Nuclear Power Station and sent to Oak Ridge National Laboratory (ORNL) in January 2016. ORNL performed detailed nondestructive examination (NDE) on all 25 rods. The NDE consisted of visual examinations, gamma and neutron scanning, profilometry and rod length measurements, and eddy current examinations. After completing the NDE, 10 of the sister rods were delivered to Pacific Northwest National Laboratory (PNNL) in a NAC International, Inc. legal-weight truck cask in September 2018 for destructive examination (DE). To date, SFWD work has focused on the PWR fuel that is part of the Sister Rod Test program. No boiling water reactor (BWR) fuel has been tested in the program, and the data needs that were identified for the PWR fuel have not been collected for BWR fuel. The goal to obtain six to nine BWR rods and test them at ORNL will support closing this important data gap. BWR fuel comprises approximately 56% of the total fuel assemblies currently in storage at nuclear power plants in the United States. BWR nuclear fuel and cladding designs and manufacturing are significantly different from PWRs. Differences include the following: BWR fuel pellets are larger than PWR pellets; Variations of Zircaloy-2 (including liners) are used instead of the Zircaloy-4 cladding materials used in PWRs; Clad manufacturing and stress-relief processes are different between PWRs and BWRs; The fuel rod dimensions are different because larger rod diameters and thicker cladding are used in BWRs; BWR fuel typically has lower internal rod pressures and sees vastly different operating conditions than PWR fuel (i.e., two-phase flow); BWR assemblies are “canned,” meaning each assembly is surrounded by a metal fuel channel; BWR cladding is often composed of an inner pure Zr liner that has widely different mechanical properties than the Zircaloy-2 alloy and exhibits a stronger affinity for hydrogen; The BWR SNF generally has more total hydrogen in the cladding/liner than typical PWR fuel; The construction of the PWR and BWR assemblies is vastly different; BWR rods are solidly attached to the assembly nozzles and experience a much different vibration and shock load than PWR rods, which are “floating” within a grid system attached to guide tubes, and the rods sit loosely on the bottom end plates. These numerous differences will affect the way the BWR SNF responds under dry storage preparation processes (e.g., vacuum drying) and during transportation. The results collected in the PWR experimental program must be compared with a subset of similar data collected on BWR SNF to establish a technical basis for whether the larger PWR database is sufficient to bound the BWR SNF end-of-life conditions as is currently assumed for several fuel/clad properties. Changes that occur in both fuel types at HBU could exacerbate any mechanical property differences. As the fuel burnup increases, several changes occur that might affect the performance of the fuel, cladding, and assembly hardware in storage and transportation. These changes include increased cladding corrosion layer thickness, increased cladding hydrogen content, increased cladding creep strains, increased fission gas release, and the formation of the HBU structure at the surface of the fuel pellets. The Nuclear Regulatory Commission (NRC) limits the current maximum rod-averaged burnup to 62 GWd/MTU due to these changes and the lack of data at higher burnups.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Modeling of a Solar-To-Hydrogen Flexible High Temperature Steam Electrolysis Plant

Sustainble hydrogen production for use as a renewable combustible fuel and clean chemical feedstock is an important objective as the world moves towards a renewable energy future. High temperature steam electrolysis is a promising hydrogen production technology due to its reduced electric input that is offset by heat input into steam generation and steam superheating. An option to provide this heat is to use concentrating solar thermal technology that can sustainably provide heat input while renewable electricity is used for the electrolysis reaction. In this work, a solar-to-hydrogen high temperature steam electrolysis plant is designed and dynamically modeled, showing continuous hydrogen production by utilizing supplemental heating and efficient recuperative heating from the electrolysis product streams. Through this design, over 90% of the required heat input for the process can by met by a combination of solar and recuperative heat. Additionally, the plant can flexibility operate by ramping down hydrogen production and through flexible heat integration, which intelligently integrates solar heat based on solar conditions. Smooth operation with flexible hydrogen production is demonstrated which decreases electrical input during on-peak grid times and also decreases the total supplemental heat load over the course of a day from 26.1% to 24.5%. In addition, by using flexible heat integration, the plant can increase its solar heat usage by 4.1% relative to a base case. Both options for flexibility show efficient use of solar thermal energy to sustainably and continuously produce hydrogen.

Immonen, Jake (ORCID:0000000341231625)↗

New component development for multi-100 kW low-cost solar array applications

Studies of the cost and performance of flexible arrays have shown that the most dramatic reductions in the $/Watt figure of merit are achieved by increasing performance. An examination of those properties that contribute to array performance indicated areas where radical changes in current design practice and philosophy would result in significant cost and performance impacts. To take advantage of the predicted cost reductions, modules were fabricated and tested that had ultra-thin superstrates as a load carrying member and large area dielectric wraparound (DWA), gridded back surface and copper contacted solar cells.

Pack, G. J.↗

An Aerodynamic Analysis of a Spinning Missile with Dithering Canards

A generic spinning missile with dithering canards is used to demonstrate the utility of an overset structured grid approach for simulating the aerodynamics of rolling airframe missile systems. The approach is used to generate a modest aerodynamic database for the generic missile. The database is populated with solutions to the Euler and Navier-Stokes equations. It is used to evaluate grid resolution requirements for accurate prediction of instantaneous missile loads and the relative aerodynamic significance of angle-of-attack, canard pitching sequence, viscous effects, and roll-rate effects. A novel analytical method for inter- and extrapolation of database results is also given.

Meakin, Robert L.↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

Scale-Resolving Simulations of a Supersonic Retro-Propulsion Concept For Mars Entry, Descent, and Landing

Supersonic retro-propulsion (SRP) is a deceleration technology that could enable largerpayloads and potentially humans to be brought from space to the surface of Mars safely.Accurate and reliable CFD predictions are needed to help design future Mars entry, descent,and landing (EDL) vehicles due to the cost and limitations of wind tunnel tests. TypicalCFD approaches struggle at points along the Mars EDL trajectory with high enough altitude(low enough ambient pressure) that the SRP motor plumes are over-expanded. This workdemonstrates how high-order scale-resolving simulations on Cartesian AMR grids can provideaccurate and reliable time-averaged aerodynamic loads on the vehicle for this challengingflow regime. Greater than second order convergence in the time-averaged integrated axialforce𝐶𝐴is obtained across the three finest mesh resolutions simulated, and the estimateduncertainty is smaller than the unsteady standard deviation – demonstrating the accuracy andreliability of the method. Although costly, this approach can yield higher confidence in𝐶𝐴thanpreviously obtained in a reasonable turnaround time and is within reach for a few points in thetrajectory (i.e. Mach 2.4, 2.52, and 2.78). Further computational performance and numericalmethods improvements are needed to reduce the cost enough to bring this method into the EDLengineering design cycle.

S&M↗

OVERFLOW Analysis of Supersonic Retropropulsion Testing on a Blunt Mars Entry Vehicle Concept

Supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle was simulated using the Overflow Computational Fluid Dynamics (CFD) solver. Two nozzle configurations were tested (1E and 1F) as a subset of the seven total configurations in the Descent System Study (DSS) testing campaign. A generalized, Adaptive Mesh Refinement (AMR) shock capturing and plume refinement technique was developed and calibrated for producing automatic and unique grid systems optimized for any given testing condition. Solution independence from grid resolution was determined by successively increasing grid refinement until asymptotic convergence of the mean aerodynamic loads was observed. Overflow Reynolds-averaged Navier-Stokes (RANS) solutions produced realistic SRP flow phenomena, including Mach disk normal shocks contained in high-thrust plumes and bow shock triple-points. Solutions for the 1E nozzle configuration were steady. Conversely, a subset of the 1F test conditions were unsteady and exhibited periodic, non-sinusoidal expansions and contractions of the streamwise-oriented plume, resulting in unsteady aerodynamic loads on the vehicle. Initial investigations into the effect of turbulence modeling fidelity demonstrated significant differences between the aerodynamic loads simulated with RANS and Detached Eddy Simulation (DES). Multiple flow mechanisms were identified as root causes of these differences, including bow shock shape augmentation and reduced entrainment due to reduced turbulence in the DES simulations. Initial comparisons of pitching moment control authority and aerodynamic drag performance between the tested nozzle configurations demonstrated that the 1E configuration may be more advantageous for the Mars Entry, Descent, and Landing (EDL) task.

Supersonic Retropropulsion↗

Modeling Smart Microgrids for the Developing World with Probabilistic Supply and Demand Inputs

Developing world microgrids often balance insufficient supply with growing, unpredictable demand. Deterministic and probabilistic simulators exist to model these microgrids, and each focuses on different technical aspects. With the addition of smart meters into microgrids, monitoring and control is now available at high granularity, which enriches microgrid planning and operation. This research is designing a new simulator to model smart microgrids with discrete probability distributions as supply and demand inputs. In our model, smart meters allow real-time power clipping for demand side management, effectively smoothing the system load curve as needed. To compare clipping schemes for grid operation and generation mixes for planning, we aggregate inputs by convolution then compute expected energy sold and probability of avoiding power cuts. The simulator plots these values for different combinations of power clipping threshold and number of customers clipped.

13 HYDRO ENERGY↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗