Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Multiphase Large Eddy Simulation of a Pulsed Sieve-Plate Extraction Column - 18125

Presented here is research resulting from a framework of single-phase and multiphase modelling trials. These are intended to accurately simulate the internal flow phenomena arising in pulsed sieve-plate extraction columns representative of those found in industry. Three-dimensional unsteady flow calculations using large eddy simulation coupled with dynamic sub-grid scale modelling have been used to capture the transient effects of sinusoidal flow conditions using the open source CFD code OpenFOAM{sup R}. Multiphase interface interactions are modelled using the volume of fluid method with appropriate heavy and light phase fluidic properties capturing surface tension, density and viscous effects. The system studied consists of a 150 mm diameter column with two perforated plates with a fractional free area of 25 %, operational under 1 Hz pulsing frequency at a 50 mm amplitude and plate spacing of 300 mm. The materials simulated include water (single-phase) and 3 M nitric acid and dodecane / tributyl phosphate mixture at 30 vol% (multiphase). Results are compared with appropriate correlations from literature. The dispersive mixing efficiency of the system was also evaluated via a mixing index value which allows quantification of the ratio of rotational and irrotational flow components. This study has found that the predictive methods employed are effective at capturing the different scales of turbulence present within pulsed sieve-plate extraction columns, and its influence on their operation. As such, the work highlights the ability of large eddy simulation-based modelling to predict the complex flows in such column geometries. Furthermore, the techniques employed provide valuable insight into the hydrodynamic flow characteristics and mixing mechanisms arising within pulsed sieve-plate extraction columns. (authors)

42 ENGINEERING↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Direct Numerical Simulation of Transitional and Turbulent Flows Over Multi-Scale Surface Roughness—Part I: Methodology and Challenges

Abstract High-fidelity simulation of transitional and turbulent flows over multi-scale surface roughness presents several challenges. For instance, the complex and irregular geometrical nature of surface roughness makes it impractical to employ conforming structured grids, commonly adopted in large-scale numerical simulations due to their high computational efficiency. One possible solution to overcome this problem is offered by immersed boundary methods, which allow wall boundary conditions to be enforced on grids that do not conform to the geometry of the solid boundary. To this end, a three-dimensional, second-order accurate boundary data immersion method (BDIM) is adopted. A novel mapping algorithm that can be applied to general three-dimensional surfaces is presented, together with a newly developed data-capturing methodology to extract and analyze on-surface flow quantities of interest. A rigorous procedure to compute gradient quantities such as the wall shear stress and the heat flux on complex non-conforming geometries is also introduced. The new framework is validated by performing a direct numerical simulation (DNS) of fully developed turbulent channel flow over sinusoidal egg-carton roughness in a minimal-span domain. For this canonical case, the averaged streamwise velocity profiles are compared against results from the literature obtained with a body-fitted grid. General guidelines on the BDIM resolution requirements for multi-scale roughness simulation are given. Momentum and energy balance methods are used to validate the calculation of the overall skin friction and heat transfer at the wall. The BDIM is then employed to investigate the effect of irregular homogeneous surface roughness on the performance of an LS-89 high-pressure turbine blade at engine-relevant conditions using DNS. This is the first application of the BDIM to realize multi-scale roughness for transitional flow in transonic conditions in the context of high-pressure turbines. The methodology adopted to generate the desired roughness distribution and to apply it to the reference blade geometry is introduced. The results are compared to the case of an equivalent smooth blade.

Engineering↗

Budget-Constrained Sizing of Renewable and Energy Storage Systems for Farm-Scale Ammonia Production Within the Food-Energy-Water Nexus

In the transition toward sustainable agriculture, farms have emerged as eco-friendly pioneers, harnessing clean hybrid wind and solar systems to improve farm performance. A concern in this paradigm is the effective sizing of renewable energy systems to ensure optimal energy use within budget considerations. This research focuses on optimizing renewable energy sizing in small-scale ammonia production to meet specific farm demands and enhance local resilience, emphasizing the interplay between environmental and economic factors. These findings promise increased energy efficiency and sustainability in this innovative agricultural sector. Additionally, our approach considers small-scale ammonia plant needs and the dynamic relationships between ammonia, water, and farm demands. Simulations demonstrate substantial cost savings in farm electricity consumption. Specifically, scenarios with renewable energy integration in the farm can reduce at least 13% electricity cost compared to a grid-dependent system in the 15-year simulation.

ammonia↗

Electron attenuation in free, neutral ethane clusters

The electron effective attenuation length (EAL) in free, neutral ethane clusters has been determined at 40 eV kinetic energy by combining carbon 1s x-ray photoelectron spectroscopy and theoretical lineshape modeling. More specifically, theory is employed to form model spectra on a grid in cluster size (N) and EAL (λ), allowing N and λ to be determined by optimizing the goodness-of-fit χ{sup 2}(N, λ) between model and observed spectra. Experimentally, the clusters were produced in an adiabatic-expansion setup using helium as the driving gas, spanning a range of 100–600 molecules in mean cluster size. The effective attenuation length was determined to be 8.4 ± 1.9 Å, in good agreement with an independent estimate of 10 Å formed on the basis of molecular electron-scattering data and Monte Carlo simulations. The aggregation state of the clusters as well as the cluster temperature and its importance to the derived EAL value are discussed in some depth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A priori mesh quality metrics for three-dimensional hybrid grids

Use of general hybrid grids to attain complex-geometry field simulations poses a challenge on estimation of their quality. Apart from the typical problems of non-uniformity and non-orthogonality, the change in element topology is an extra issue to address. The present work derives and evaluates an a priori mesh quality indicator for structured, unstructured, as well as hybrid grids consisting of hexahedra, prisms, tetrahedra, and pyramids. Emphasis is placed on deriving a direct relation between the quality measure and mesh distortion. The work is based on use of the Finite Volume discretization for evaluation of first order spatial derivatives. The analytic form of the truncation error is derived and applied to elementary types of mesh distortion including typical hybrid grid interfaces. The corresponding analytic expressions provide relations between the truncation error and the degree of stretching, skewness, shearing, torsion, expansion, as well as the type of grid interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of Precipitation and Mesoscale Convective Systems Over the Peruvian Central Andes in Multi 5‐Year Convection‐Permitting Simulations

Abstract Using the Weather Research and Forecasting model with two planetary boundary layer schemes, ACM2 and MYNN, convection‐permitting model (CPM) regional climate simulations were conducted for a 6‐year period, including a one‐year spin‐up period, at a 15‐km grid spacing covering entire South America and a nested convection‐permitting 3‐km grid spacing covering the Peruvian central Andes region. These two CPM simulations along with a 4‐km simulation covering South America produced by National Center for Atmospheric Research (NCAR), three gridded precipitation products, and rain gauge data in Peru and Brazil, are used to document the characteristics of precipitation and mesoscale convective systems (MCSs) in the Peruvian central Andes region. Results show that all km‐scale simulations generally capture the spatiotemporal patterns of precipitation and MCSs at both seasonal and diurnal scales, although biases exist in aspects such as precipitation intensity and MCS frequency, size, propagation speed, and associated precipitation intensity. The 3‐km simulation using MYNN scheme generally outperforms the other simulations in capturing seasonal and diurnal precipitation over the mountain, while both it and the 4‐km simulation demonstrate superior performance in the western Amazon Basin, based on the comparison to the gridded precipitation products and gauge data. Dynamic factors, primarily low‐level jet and terrain‐induced uplift, are the key drivers for precipitation and MCS genesis along the east slope of the Andes, while thermodynamic factors control the precipitation and MCS activity in the western Amazon Basin and over elevated mountainous regions. The study suggests model improvements and better model configurations for future regional climate projections.

Meteorology & Atmospheric Sciences↗

THE SIGNATURE OF INITIAL CONDITIONS ON MAGNETOHYDRODYNAMIC TURBULENCE

We demonstrate that the initial correlation between velocity and current density fluctuations can lead to the formation of enormous current sheets in freely evolving magnetohydrodynamic (MHD) turbulence. These coherent structures are observed at the peak of the energy dissipation rate and are the carriers of long-range correlations despite all of the nonlinear interactions during the formation of turbulence. The size of these structures spans our computational domain, dominating the scaling of the energy spectrum, which follows a E∝k {sup –2} power law. As the Reynolds number increases, the curling of the current sheets due to Kelvin-Helmholtz-type instabilities and reconnection modifies the scaling of the energy spectrum from k {sup –2} toward k {sup –5/3}. This transition occurs due to the decorrelation of the velocity and the current density which is proportional to Re{sub λ}{sup −3/2}. Finite Reynolds number behavior is observed without reaching a finite asymptote for the energy dissipation rate even for a simulation of Re{sub λ} ≅ 440 with 2048{sup 3} grid points. This behavior demonstrates that even state-of-the-art numerical simulations of the highest Reynolds numbers can be influenced by the choice of initial conditions and consequently they are inadequate to deduce unequivocally the fate of universality in MHD turbulence. Implications for astrophysical observations are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolution requirements for aero-optical simulations

Analytical criteria are developed to estimate the error of aero-optical computations due to inadequate spatial resolution of refractive index fields in high Reynolds number flow simulations. The unresolved turbulence structures are assumed to be locally isotropic and at low turbulent Mach number. Based on the Kolmogorov spectrum for the unresolved structures, the computational error of the optical path length is estimated and linked to the resulting error in the computed far-field optical irradiance. It is shown that in the high Reynolds number limit, for a given geometry and Mach number, the spatial resolution required to capture aero-optics within a pre-specified error margin does not scale with Reynolds number. In typical aero-optical applications this resolution requirement is much lower than the resolution required for direct numerical simulation, and therefore, a typical large-eddy simulation can capture the aero-optical effects. The analysis is extended to complex turbulent flow simulations in which non-uniform grid spacings are used to better resolve the local turbulence structures. As a demonstration, the analysis is used to estimate the error of aero-optical computation for an optical beam passing through turbulent wake of flow over a cylinder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time evaluation of cybersecurity threats to DER inverter grid-support functions

In this project we aim to contribute to the understanding of the type and severity of potential cybersecurity attacks to the grid-support functionalities of DER systems interconnected to the AC distribution grid via inverters. Our preliminary work focused on developing a small-scale testbed allowing to study cybersecurity threats to an isolated photovoltaic-battery system using a real-time simulator (Typhoon HIL602+) with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) system. In this project we propose to expand upon this development by utilizing a) a recently acquired NovaCor RTDS (Real Rime digital Simulator) to emulate the DER-inverter-grid topology including main grid-support functions as defined by IEEE Std. 1547-2018, and b) an industrial control and automation device to enable realistic evaluation of control functions and utilization of communication protocols for real-time data transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the effects of a nonhydrostatic dynamical core in high-resolution aquaplanet simulations

This study explores the impact of a nonhydrostatic dynamical core in high-resolution regional climate simulations using an aquaplanet framework. The Weather Research and Forecasting (WRF) model is used to conduct simulations with both hydrostatic (H) and nonhydrostatic (NH) solvers at horizontal grid spacings (?x) of 36, 12, and 4 km. The differences between the H and NH simulated precipitation (?P) are notable even at ?x = 12 km in the inter-tropical convergence zone and the transition region to the drier subtropics. At gray-zone grid spacing (12 km and 4 km) over the tropics, ?P is sensitive to whether a cumulus parameterization scheme is used or not. With an idealized Witch of Agnesi land mountain, differences in the precipitation and circulation (vertical velocity) between the H and NH simulations are significant even at ?x = 36 km in the tropics due largely to the strong feedbacks related to moist processes. The differences increase as the model grid spacing and mountain half width (a) are reduced, accompanied by a shift towards a more nonhydrostatic flow regime at a = 24 km. Latent heat release drastically enhances the differences between the NH and H simulations and extends the effect of nonhydrostatic dynamics to a broader region over the mountain and downstream over the tropics. Overall, differences exist between H and NH simulations even at resolutions between 12 and 36 km, but the differences are sensitive to the representations of moist physics and other features such as horizontal diffusion used in the WRF model.

nonhydrostatic dynamics, latent heating, nonhydros↗

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

Broadening of Cloud Droplet Spectra through Eddy Hopping: Turbulent Adiabatic Parcel Simulations

Abstract This paper investigates spectral broadening of droplet size distributions through a mechanism referred to as the eddy hopping. The key idea, suggested a quarter century ago, is that droplets arriving at a given location within a turbulent cloud follow different trajectories and thus experience different growth histories and that this leads to a significant spectral broadening. In this study, the adiabatic parcel model with superdroplets is used to contrast droplet growth with and without turbulence. Turbulence inside the parcel is described by two parameters: (i) the dissipation rate of the turbulent kinetic energy ε and (ii) the linear extent of the parcel L. As expected, an adiabatic parcel without turbulence produces extremely narrow droplet spectra. In the turbulent parcel, a stochastic scheme is used to account for vertical velocity fluctuations that lead to local supersaturation fluctuations for each superdroplet. These fluctuations mimic the impact of droplets hopping turbulent eddies in a natural cloud. For L smaller than a few meters, noticeable spectral broadening is possible only for strong turbulence—say, ε > 100 cm2 s−3. For L typical for grid lengths of large-eddy simulation (LES) models (say, L between 10 and 100 m), the impact is significant even with relatively modest turbulence intensities. The impact increases with both L and ε. The representation of eddy hopping developed in this paper can be included in a straightforward way in the subgrid-scale scheme of a Lagrangian LES cloud model and may lead to a significant acceleration of simulated rain development through collision–coalescence.

Grabowski, Wojciech W.↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗