Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Post‐operative nausea and vomiting in bariatric surgery patients: an observational study

Background The risk of post‐operative nausea and vomiting (PONV) in patients undergoing bariatric surgery is unclear. The aim of the study was to investigate the risk of PONV and the use and effectiveness of PONV prophylaxis. Methods This prospective observational study included 74 patients undergoing bariatric surgery with total intravenous anaesthesia. Patients were given PONV prophylaxis based on published guidelines and a simplified PONV risk score. Perioperative data were collected and a questionnaire was used at 2, 4, 6, 24, 48 and 72 h after the operation to evaluate PONV. Data are presented as risk (%) with the 95% confidence interval. Results Sixty five per cent (54–75) of the patients experienced PONV in the first 24 post‐operative hours and the risk increased with the number of risk factors for PONV. PONV occurred in 78% (66–87) of women and 26% (12–49) of men during the first 24 h. In relation to the guidelines, one patient received suboptimal PONV prophylaxis, 23% received optimal prophylaxis and 76% supra‐optimal prophylaxis. The risk of PONV was 82% (59–94) with optimal prophylaxis and 59% (46–71) with supra‐optimal prophylaxis. Of all patients, 34% (24–45) experienced severe PONV in the first 24 h that limited their activity. Conclusions The incidence of PONV in bariatric surgery patients was high despite a PONV prophylaxis regime following current guidelines. These results cast doubt as to the effectiveness of the usual PONV prophylaxis in this patient group and point to the need for further investigation of PONV prophylaxis and treatment in bariatric surgery patients.

Halliday, T. A.↗

Presentation of FP7 matter project: general overview

The 2010-2012 implementation plan of the European Sustainable Nuclear Industrial Initiative (ESNII), prepared in the frame of the Sustainable Nuclear Energy Technology Platform (SNETP), establishes a very tight time schedule for the start of construction of the European Gen IV prototypes; namely the construction of the LFR ETPP (European Technology Pilot Plant) MYRRHA will start in 2014 and that of the SFR Prototype ASTRID will start in 2017. The GEN IV reactors pose new challenges to the designers and scientists in terms of higher operating temperature, higher fuel burn-up, and in some cases more corrosive environment with respect to the present technologies and which impacts the materials performance. In this frame, the MATTER (Materials Testing and Rules) Project starts well targeted R and D activities to perform careful materials studies in GEN IV operational conditions and to find out criteria for the correct use of these materials in relevant reactor applications. Aim of the MATTER Project (that involved 27 partners and will end in 2015) is to complement the materials researches, in the frame of the European Energy Research Alliance (EERA) guidelines, with the implementation of pre-normative rules. The MATTER Project is divided in 3 technical Domains (called DM): DM1 - Development of test and evaluation guidelines for structural materials: to develop/establish best practice guidelines for testing and evaluation procedures, which are aimed to screen and characterize nuclear materials for innovative nuclear systems. DM2 - Pre-normative R and D for Codes and Standards: Pre-normative activities are performed, comprehensive of experiments, to revise and update the design rules (with an EU level consensus) in order to answer to some short term needs of the two projects ASTRID and MYRRHA with respect to the design and the construction of structural components. DM3 - Joint Program Scheme, implementation and Priorities: to optimise the effectiveness and efficiency of the EERA Joint Program on nuclear materials for innovative reactors and to support specific research activities related to fundamental understanding of ODS steels fabrication. ODS steels are considered candidate materials, in the medium-long term, for high fuel burn-up cladding application. After a brief presentation of DM1 and DM3, this paper mainly focuses on description of Pre-normative R and D activities for Codes and Standards (DM2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-153: MRI Based, Daily Adaptive Radiotherapy for Rectal Cancer: Contour Adaptation

Purpose: A major hurdle in adaptive radiotherapy is the adaptation of the planning MRI's delineations to the daily anatomy. We therefore investigate the accuracy and time needed for online clinical target volume (CTV) adaptation by radiation therapists (RTT), to be used in MRI-guided adaptive treatments on a MRI-Linac (MRL). Methods: Sixteen patients, diagnosed with early stage rectal cancer, underwent a T2-weighted MRI prior to each fraction of short-course radiotherapy, resulting in 4–5 scans per patient. On these scans, the CTV was delineated according to guidelines by an experienced radiation oncologist (RO) and considered to be the gold standard. For each patient, the first MRI was considered as the planning MRI and matched on bony anatomy to the 3–4 daily MRIs. The planning MRI's CTV delineation was rigidly propagated to the daily MRI scans as a proposal for adaptation. Three RTTs in training started the adaptation of the CTV conform guidelines, after a two hour training lecture and a two patient (n=7) training set. To assess the inter-therapist variation, all three RTTs altered delineations of 3 patients (n=12). One RTT altered the CTV delineations (n=53) of the remaining 11 patients. Time needed for adaptation of the CTV to guidelines was registered.As a measure of agreement, the conformity index (CI) was determined between the RTTs' delineations as a group. Dice similarity coefficients were determined between delineations of the RTT and the RO. Results: We found good agreement between RTTs' and RO's delineations (average Dice=0.91, SD=0.03). Furthermore, the inter-observer agreement between the RTTs was high (average CI=0.94, SD=0.02). Adaptation time reduced from 10:33 min (SD= 3:46) to 2:56 min (SD=1:06) between the first and last ten delineations, respectively. Conclusion: Daily CTV adaptation by RTTs, seems a feasible and safe way to introduce daily, online MRI-based plan adaptation for a MRL.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-04: Statistical Process Control for Patient-Specific QA in Proton Beams

Purpose: To evaluate and improve the reliability of proton QA process, to provide an optimal customized level using the statistical process control (SPC) methodology. The aim is then to suggest the suitable guidelines for patient-specific QA process. Methods: We investigated the constancy of the dose output and range to see whether it was within the tolerance level of daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to suggest the suitable guidelines for patient-specific QA in proton beam by using process capability indices. In this study, patient QA plans were classified into 6 treatment sites: head and neck (41 cases), spinal cord (29 cases), lung (28 cases), liver (30 cases), pancreas (26 cases), and prostate (24 cases). Results: The deviations for the dose output and range of daily QA process were ±0.84% and ±019%, respectively. Our results show that the patient-specific range measurements are capable at a specification limit of ±2% in all treatment sites except spinal cord cases. In spinal cord cases, comparison of process capability indices (Cp, Cpm, Cpk ≥1, but Cpmk ≤1) indicated that the process is capable, but not centered, the process mean deviates from its target value. The UCL (upper control limit), CL (center line) and LCL (lower control limit) for spinal cord cases were 1.37%, −0.27% and −1.89%, respectively. On the other hands, the range differences in prostate cases were good agreement between calculated and measured values. The UCL, CL and LCL for prostate cases were 0.57%, −0.11% and −0.78%, respectively. Conclusion: SPC methodology has potential as a useful tool to customize an optimal tolerance levels and to suggest the suitable guidelines for patient-specific QA in clinical proton beam.

60 APPLIED LIFE SCIENCES↗

SU-E-T-148: Benchmarks and Pre-Treatment Reviews: A Study of Quality Assurance Effectiveness

Purpose: To determine the impact benchmarks and pre-treatment reviews have on improving the quality of submitted clinical trial data. Methods: Benchmarks are used to evaluate a site’s ability to develop a treatment that meets a specific protocol’s treatment guidelines prior to placing their first patient on the protocol. A pre-treatment review is an actual patient placed on the protocol in which the dosimetry and contour volumes are evaluated to be per protocol guidelines prior to allowing the beginning of the treatment. A key component of these QA mechanisms is that sites are provided timely feedback to educate them on how to plan per the protocol and prevent protocol deviations on patients accrued to a protocol. For both benchmarks and pre-treatment reviews a dose volume analysis (DVA) was performed using MIM softwareTM. For pre-treatment reviews a volume contour evaluation was also performed. Results: IROC Houston performed a QA effectiveness analysis of a protocol which required both benchmarks and pre-treatment reviews. In 70 percent of the patient cases submitted, the benchmark played an effective role in assuring that the pre-treatment review of the cases met protocol requirements. The 35 percent of sites failing the benchmark subsequently modified there planning technique to pass the benchmark before being allowed to submit a patient for pre-treatment review. However, in 30 percent of the submitted cases the pre-treatment review failed where the majority (71 percent) failed the DVA. 20 percent of sites submitting patients failed to correct their dose volume discrepancies indicated by the benchmark case. Conclusion: Benchmark cases and pre-treatment reviews can be an effective QA tool to educate sites on protocol guidelines and to minimize deviations. Without the benchmark cases it is possible that 65 percent of the cases undergoing a pre-treatment review would have failed to meet the protocols requirements.Support: U24-CA-180803.

60 APPLIED LIFE SCIENCES↗

TU-C-201-00: Clinical Implementation of HDR Brachytherapy

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-01: Clinical Implementation of HDR: A New User’s Perspective

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-02: Clinical Implementation of HDR: Afterloader and Applicator Selection

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-03: The Use of Checklists and Audit Tools for Safety and QA

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-03: IMRT Dosimetry Differences in An Institution with Community and Academic Model

Purpose: Radiation outcome among institutions can be interpreted meaningfully if the dose delivery and prescription to the target volume is documented accurately and consistently. ICRU-83 recommended specific guidelines in IMRT for target volume definitions and dose reporting. This retrospective study evaluates the pattern of IMRT dose prescription and recording in an academic institution (AI) and a community hospital (CH) models in a single institution with reference to ICRU-83 recommendation. Materials & Methods: Dosimetric information of 625 (500 from academic and 125 from community) patients treated with IMRT was collected retrospectively from the AI and a CH. The dose-volume histogram (DVH) for the target volume of each patient was extracted. Standard dose parameters such as D2, D50, D95, D98, D100, as well as the homogeneity index (HI) defined as (D2-D98)/D50 and monitor units (MUs) were collected. Results: Significant dosimetric variations were observed in disease sites and between AI and CH. The variation in the mean value of D95 for AI is 98.48±4.12 and for CH is 96.41±4.13. A similar pattern was noticed for D50 (104.18±6.04 for AI and 101.05±3.49 for CH). Thus, nearly 95% of patients received dosage higher than 100% to the site viewed by D50 and varied between AI and CH models. The average variation of HI is found to be 0.12±0.08 and 0.11±0.08 for AI and CH model, showing better IMRT treatment plans for academic model compared to community. Conclusion: Even with the implementation of ICRU-83 guidelines, there is a large variation in dose prescription and delivery in IMRT. The variation is institution and site specific. For any meaningful comparison of the IMRT outcome, strict guidelines for dose reporting should be maintained in every institution.

60 APPLIED LIFE SCIENCES↗

MO-A-BRB-00: TG191: Clinical Use of Luminescent Dosimeters

This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3) To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-A-BRB-01: TG191: Clinical Use of Luminescent Dosimeters

This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3) To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of the TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.

60 APPLIED LIFE SCIENCES↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Evaluation of Visual Analytics Environments: The Road to the Visual Analytics Science and Technology Challenge Evaluation Methodology

The evaluation of visual analytics environments was a topic in Illuminating the Path [Thomas 2005] as a critical aspect of moving research into practice. For a thorough understanding of the utility of the systems available, evaluation not only involves assessing the visualizations, interactions or data processing algorithms themselves, but also the complex processes that a tool is meant to support (such as exploratory data analysis and reasoning, communication through visualization, or collaborative data analysis [Lam 2012; Carpendale 2007]). Researchers and practitioners in the field have long identified many of the challenges faced when planning, conducting, and executing an evaluation of a visualization tool or system [Plaisant 2004]. Evaluation is needed to verify that algorithms and software systems work correctly and that they represent improvements over the current infrastructure. Additionally to effectively transfer new software into a working environment, it is necessary to ensure that the software has utility for the end-users and that the software can be incorporated into the end-user’s infrastructure and work practices. Evaluation test beds require datasets, tasks, metrics and evaluation methodologies. As noted in [Thomas 2005] it is difficult and expensive for any one researcher to setup an evaluation test bed so in many cases evaluation is setup for communities of researchers or for various research projects or programs. Examples of successful community evaluations can be found [Chinchor 1993; Voorhees 2007; FRGC 2012]. As visual analytics environments are intended to facilitate the work of human analysts, one aspect of evaluation needs to focus on the utility of the software to the end-user. This requires representative users, representative tasks, and metrics that measure the utility to the end-user. This is even more difficult as now one aspect of the test methodology is access to representative end-users to participate in the evaluation. In many cases the sensitive nature of data and tasks and difficult access to busy analysts puts even more of a burden on researchers to complete this type of evaluation. User-centered design goes beyond evaluation and starts with the user [Beyer 1997, Shneiderman 2009]. Having some knowledge of the type of data, tasks, and work practices helps researchers and developers know the correct paths to pursue in their work. When access to the end-users is problematic at best and impossible at worst, user-centered design becomes difficult. Researchers are unlikely to go to work on the type of problems faced by inaccessible users. Commercial vendors have difficulties evaluating and improving their products when they cannot observe real users working with their products. In well-established fields such as web site design or office software design, user-interface guidelines have been developed based on the results of empirical studies or the experience of experts. Guidelines can speed up the design process and replace some of the need for observation of actual users [heuristics review references]. In 2006 when the visual analytics community was initially getting organized, no such guidelines existed. Therefore, we were faced with the problem of developing an evaluation framework for the field of visual analytics that would provide representative situations and datasets, representative tasks and utility metrics, and finally a test methodology which would include a surrogate for representative users, increase interest in conducting research in the field, and provide sufficient feedback to the researchers so that they could improve their systems.

evaluation↗

Sensemaking, stakeholder discord, and long-term risk communication at a US Superfund site

Abstract Introduction: Risk communication can help reduce exposures to environmental contaminants, mitigate negative health outcomes, and inform community-based decisions about hazardous waste sites. While communication best practices have long guided such efforts, little research has examined unintended consequences arising from such guidelines. As rhetoric informs stakeholder sensemaking, the language used in and reinforced by these guidelines can challenge relationships and exacerbate stakeholder tensions. Objectives: This study evaluates risk communication at a U.S. Superfund site to identify unintended consequences arising from current risk communication practices. Methods: This qualitative case study crystallizes data spanning 6 years from three sources: 1) local newspaper coverage of site-related topics; 2) focus-group transcripts from a multi-year project designed to support future visioning of site use; and 3) published blog entries authored by a local environmental activist. Constant comparative analysis provides the study’s analytic foundation, with qualitative data analysis software QSR NVivo 8 supporting a three-step process: 1) provisional coding to identify broad topic categories within datasets, 2) coding occurrences of sensemaking constructs and emergent intra-dataset patterns, and 3) grouping related codes across datasets to examine the relationships among them. Results: Existing risk communication practices at this Superfund site contribute to a dichotomous conceptualization of multiple and diverse stakeholders as members of one of only two categories: the government or the public. This conceptualization minimizes perceptions of capacity, encourages public commitment to stances aligned with a preferred group, and contributes to negative expectations that can become self-fulfilling prophecies. Conclusion: Findings indicate a need to re-examine and adapt risk communication guidelines to encourage more pluralistic understanding of the stakeholder landscape.

Environmental Sciences & Ecology↗

Sample Identifiers and Metadata Reporting Format for Environmental Systems Science

The ESS-DIVE sample identifiers and metadata reporting format primarily follows the System for Earth Sample Registration (SESAR) Global Sample Number (IGSN) guide and template, with modifications to address Environmental Systems Science (ESS) sample needs and practicalities (IGSN-ESS). IGSNs are associated with standardized metadata to characterize a variety of different sample types (e.g. object type, material) and describe sample collection details (e.g. latitude, longitude, environmental context, date, collection method). Globally unique sample identifiers, particularly IGSNs, facilitate sample discovery, tracking, and reuse; they are especially useful when sample data is shared with collaborators, sent to different laboratories or user facilities for analyses, or distributed in different data files, datasets, and/or publications. To develop recommendations for multidisciplinary ecosystem and environmental sciences, we first conducted research on related sample standards and templates. We provide a comparison of existing sample reporting conventions, which includes mapping metadata elements across existing standards and Environment Ontology (ENVO) terms for sample object types and environmental materials. We worked with eight U.S. Department of Energy (DOE) funded projects, including those from Terrestrial Ecosystem Science and Subsurface Biogeochemical Research Scientific Focus Areas. Project scientists tested the process of registering samples for IGSNs and associated metadata in workflows for multidisciplinary ecosystem sciences. We provide modified IGSN metadata guidelines to account for needs of a variety of related biological and environmental samples. While generally following the IGSN core descriptive metadata schema, we provide recommendations for extending sample type terms, and connecting to related templates geared towards biodiversity (Darwin Core) and genomic (Minimum Information about any Sequence, MIxS) samples and specimens. ESS-DIVE recommends registering samples for IGSNs through SESAR, and we include instructions for registration using the IGSN-ESS guidelines. Our resulting sample reporting guidelines, template (IGSN-ESS), and identifier approach can be used by any researcher with sample data for ecosystem sciences.

54 ENVIRONMENTAL SCIENCES↗

A Retrospective Tiered Environmental Assessment of the Mount Storm Wind Energy Facility, West Virginia, USA

Bird and bat fatalities from wind energy projects are an environmental and public concern, with post-construction fatalities sometimes differing from predictions. Siting facilities in this context can be a challenge. In March 2012 the U.S. Fish and Wildlife Service (USFWS) released Land-based Wind Energy Guidelines to assess collision fatalities and other potential impacts to species of concern and their habitats to aid in siting and management. The Guidelines recommend a tiered approach for assessing risk to wildlife, including a preliminary site evaluation that may evaluate alternative sites, a site characterization, field studies to document wildlife and habitat and to predict project impacts, post construction studies to estimate impacts, and other post construction studies. We applied the tiered assessment framework to a case study site, the Mount Storm Wind Energy Facility in Grant County, West Virginia, USA, to demonstrate the use of the USFWS assessment approach, to indicate how the use of a tiered assessment framework might have altered outputs of wildlife assessments previously undertaken for the case study site, and to assess benefits of a tiered ecological assessment framework for siting wind energy facilities. The conclusions of this tiered assessment for birds are similar to those of previous environmental assessments for Mount Storm. This assessment found risk to individual migratory tree-roosting bats that was not emphasized in previous preconstruction assessments. Differences compared to previous environmental assessments are more related to knowledge accrued in the past 10 years rather than to the tiered structure of the Guidelines. Benefits of the tiered assessment framework include good communication among stakeholders, clear decision points, a standard assessment trajectory, narrowing the list of species of concern, improving study protocols, promoting consideration of population-level effects, promoting adaptive management through post-construction assessment and mitigation, and sharing information that can be used in other assessments.

17 WIND ENERGY↗