Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

High-Nickel Cathodes with Mechanical and Interfacial Robustness via Tailored Concentration Gradients for Stable Li-Ion Batteries

Here, we have developed a versatile mathematical framework integrated with an automated reactor system to design and reify highly customizable full concentration gradient (FCG) in high-nickel cathodes for advanced Li-ion batteries. This method provides precise and independent control of the average composition, slope, and curvature of FCGs, enabling the optimization of structural and mechanical properties of the cathode materials. We have showcased this method with Ni 0.8 Co 0.1 Mn 0.1 (OH) 2 precursors of controlled FCGs, which unlocked an optimized cathode with excellent cycling stability without crack formation after repeated cycles. This work opens up new possibilities for the design and manufacturing of advanced cathode materials, enabling safer, high-performance batteries.

25 ENERGY STORAGE↗

In situ dynamic transmission electron microscopy characterization of liquid-mediated crystallization of amorphous Ge

Crystal growth rates during laser-induced, liquid-mediated crystallization of amorphous Ge were measured with movie-mode dynamic transmission electron microscopy (MM-DTEM), a photoemission microscopy technique with nanosecond-scale time resolution. Films of 50-nm thick amorphous Ge were crystallized using a 12-ns laser pulse with a Gaussian spatial profile, which established high local temperature gradients in the specimen. Crystallization proceeded by the formation of a central zone with a high nucleation rate (zone I), followed by liquid-mediated outward growth of columnar grains (zone II), followed by spiraling growth (zone III) until the crystallization halted in cooler parts of the specimen. Zone II growth was imaged for several laser pulse energies with 20-ns electron pulses with 95 ns between frames. A thin liquid layer between the solid amorphous phase and the advancing crystallization front during zone II growth was imaged. The zone II growth rate for each experiment remained nearly constant although the crystallization front passes through a large temperature gradient. Measured growth rates ranged from 5.7 to 13.6 m/s, consistent with transient liquid layer mediated growth rather than solid-state growth. In contrast with a previous report, the growth rate did not increase systematically with laser energy or absorbed energy. The new results, together with previously reported data, suggest that both sets of experiments were conducted under conditions where the growth rate saturates near its maximum value. A phenomenological model based on the concept of upper and lower threshold temperatures for the zone II growth was fitted to the data from these experiments and previous MM-DTEM crystallization experiments.

36 MATERIALS SCIENCE↗

Nozzle material requirements and the status of intermetallic matrix composites

The HSCT exhaust nozzle must manage high temperature exhaust gases and pressure gradients while meeting HSCT economic and noise goals. The important features and requirements for an HSCT exhaust nozzle are shown for a 2DCD (two-dimensional convergent-divergent) design. The same requirements would apply to an axisymmetric design. Exhaust nozzle weight has an adverse effect on the overall aircraft range, payload, and engine specific fuel consumption and is therefore the primary driver for advanced exhaust nozzle materials. Because of the large airflow and pressure gradients, exhaust nozzles are extremely large and heavy when made from current materials. The use of advanced materials with higher specific strength will reduce the weight of exhaust nozzle components. In addition to the flow of high-temperature exhaust gases into the exhaust nozzle, ambient air is entrained to reduce gas exit velocities and suppress sound. This leads to components exposed to extremely high temperature gradients and, hence, high thermal stresses. Further, exhaust gases are highly oxidizing; material environmental resistance will be an important factor for long life. Several viable concepts have been identified to reduce noise through the mixture of exhaust and ambient air. Sound can be further suppressed by acoustic panels that absorb high-frequency noise.

Johnson, Andrew M.↗

3D Quantification of Elemental Gradients within Heterostructured Particles of Battery Cathodes

Heterogenous architectures with elemental gradients tailored within particles have been pursued to combat the instabilities limiting Ni-rich cathode materials for lithium-ion batteries. The growth of different compositional layers is accomplished during the synthesis of hydroxide precursors. However, the extent to which these concentration gradients are modified during high-temperature reactions is difficult to establish in their intact, spherical form. Here, we show the entire three-dimensional structure of a secondary particle can be resolved nondestructively with differential X-ray absorption spectroscopy (XAS) through transmission X-ray microscopy (TXM). The relationship between particle location and elemental content was fully quantified, with high statistical significance, for heterostructures possessing different compositional gradients in the precursors with 90:5:5 Ni:Mn:Co core compositions. Reduced elemental heterogeneity was observed after high-temperature synthesis, but gradients remained. In conclusion, the methodology presented should be used to guide synthesis while assuring that gains in electrochemical performance are linked to precise elemental distributions at the nanoscale.

25 ENERGY STORAGE↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

Micro-tearing mode dominated electron heat transport in DIII-D H-mode pedestal

Abstract A new, comprehensive set of evidence reveals that Micro-Tearing Modes (MTMs) dominate pedestal electron heat transport in an H-mode experiment in the DIII-D tokamak. The experiment investigates the role of MTMs by scanning pedestal collisionality, a main drive of MTM instability, from 0.43 to 0.84 on the pedestal top. Broadband (150–800 kHz) magnetic and density fluctuations originating from the pedestal gradient region and highly consistent with MTMs are observed, with amplitude increasing during the scan. The higher magnetic fluctuation amplitude correlates with a lower pedestal electron temperature gradient, implying MTMs may regulate the pedestal electron heat transport. The collisionality scan results in profile and transport changes consistent with predicted transport capability of MTMs: (1) experimentally-determined electron heat diffusivity increases ∼40% at the location where the broadband density fluctuations peak; (2) ion heat diffusivity has less increase (<20%); and (3) a locally flattened region in the electron temperature pedestal is observed at high collisionality. A local, linear gyrokinetic simulation finds MTMs as the most unstable mode in the pedestal gradient region. In addition, local, nonlinear simulations suggest MTMs can dominate and drive experimentally-relevant, megawatt-level electron heat flux. This result establishes MTMs as an effective transport mechanism in the H-mode pedestal, in particular at high collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolution requirements for velocity gradients in turbulence

Since high resolution numerical simulations of turbulent flows, or experiments at high Reynolds numbers, represent a substantial investment in resources, the estimation of the minimum resolution required for the study of a given property has been the subject of continued interest. Different properties require, in general, different resolutions, and the present paper is dedicated to the requirements for the measurement of the probability distribution functions of the velocity gradients and, in particular, of their low order moments. The deviation of these quantities from the values corresponding to a Gaussian distribution was one of the first indications of the presence of Reynolds number-dependent intermittency and has been the object of recent interest as numerical simulations have become able to explore the distribution of gradients in the low Reynolds number range, while new experiments have extended the range to increasingly high Reynolds numbers. We will use progressive filtering of the results of numerical simulations of isotropic turbulence as a model for the effect of a sensor of finite size. The numerical issues will be addressed first to ensure that the simulations are fully resolved from the point of view of the velocity gradients. This will also give us an estimate for the numerical resolution required for the different quantities.

Jimenez, Javier↗

Artifact identification in X-ray diffraction data using machine learning methods

In situ synchrotron high-energy X-ray powder diffraction (XRD) is highly utilized by researchers to analyze the crystallographic structures of materials in functional devices ( e.g. battery materials) or in complex sample environments ( e.g. diamond anvil cells or syntheses reactors). An atomic structure of a material can be identified by its diffraction pattern along with a detailed analysis of the Rietveld refinement which yields rich information on the structure and the material, such as crystallite size, microstrain and defects. For in situ experiments, a series of XRD images is usually collected on the same sample under different conditions ( e.g. adiabatic conditions) yielding different states of matter, or is simply collected continuously as a function of time to track the change of a sample during a chemical or physical process. In situ experiments are usually performed with area detectors and collect images composed of diffraction patterns. For an ideal powder, the diffraction pattern should be a series of concentric Debye–Scherrer rings with evenly distributed intensities in each ring. For a realistic sample, one may observe different characteristics other than the typical ring pattern, such as textures or preferred orientations and single-crystal diffraction spots. Textures or preferred orientations usually have several parts of a ring that are more intense than the rest, whereas single-crystal diffraction spots are localized intense spots owing to diffraction of large crystals, typically >10 µm. In this work, an investigation of machine learning methods is presented for fast and reliable identification and separation of the single-crystal diffraction spots in XRD images. The exclusion of artifacts during an XRD image integration process allows a precise analysis of the powder diffraction rings of interest. When it is trained with small subsets of highly diverse datasets, the gradient boosting method can consistently produce high-accuracy results. The method dramatically decreases the amount of time spent identifying and separating single-crystal diffraction spots in comparison with the conventional method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Co-free gradient lithium-rich cathode for high-energy batteries with optimized cyclability

Lithium-rich layered oxides (LLOs) hold the promise for high-energy battery cathodes. However, its application has been hindered by voltage decay associated with irreversible reactions at high voltages despite decades of intensive efforts. Here, we first theoretically studied the molecular orbitals of Mn-based Li-rich configurations. We found that the π-bond ring formed within the LiMn 6 structure could participate in stable redox reactions as one unit, but Co could disrupt its symmetry. We thus designed and synthesized Co-free concentration-gradient LLOs (CF-CG-LLOs) materials. The combination of concentration gradient and Co removal leads to exceptional capacity retention without any fading over 100 cycles of the pouch cell. More importantly, it exhibits an extraordinarily low voltage decay of 0.15 mV/cycle, accompanied by a high Coulombic efficiency of 99.86%. This concept and demonstration of CF-CG-LLO cathodes reveal a viable avenue toward low-cost, high-energy-density battery cathodes.

25 ENERGY STORAGE↗

A Comparison of Four Indices for Combining Distance and Dose Differences

Purpose: When one is comparing two dose distributions, a number of methods have been published to combine dose difference and distance to agreement into a single measure. Some have been defined as pass/fail indices and some as numeric indices. We show that the pass/fail indices can all be used to derive numeric indices, and we compare the results of using these indices to evaluate one-dimensional (1D) and three-dimensional (3D) dose distributions, with the aim of selecting the most appropriate index for use in different circumstances. Methods and Materials: The indices compared are the gamma index, the kappa index, the index in International Commission on Radiation Units and Measurements Report 83, and a box index. Comparisons are made for 1D and 3D distributions. The 1D distribution is chosen to have a variety of dose gradients. The 3D distribution is taken from a clinical treatment plan. The effect of offsetting distributions by known distances and doses is studied. Results: The International Commission on Radiation Units and Measurements Report 83 index causes large discontinuities unless the dose gradient cutoff is set to equal the ratio of the dose tolerance to the distance tolerance. If it is so set, it returns identical results to the kappa index. Where the gradient is very high or very low, all the indices studied in this article give similar results for the same tolerance values. For moderate gradients, they differ, with the box index being the least strict, followed by the gamma index, and with the kappa index being the most strict. Conclusions: If the clinical tolerances are much greater than the uncertainties of the measuring system, the kappa index should be used, with tolerance values determined by the clinical tolerances. In cases where the uncertainties of the measuring system dominate, the box index will be best able to determine errors in the delivery system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed characterization of the LLNL imaging proton spectrometer

Ultra-intense short pulse lasers incident on solid targets (e.g., thin Au foils) produce well collimated, broad-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields, and density gradients in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built [H. Chen et al., Rev. Sci. Instrum. 81, 10D314 (2010)] for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. In order to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple-relaxation-time color-gradient lattice Boltzmann model for simulating two-phase flows with high density ratio

In this paper, we propose a color-gradient lattice Boltzmann (LB) model for simulating two-phase flows with high density ratio and high Reynolds number. The model applies a multi-relaxation-time (MRT) collision operator to enhance the stability of the simulation. A source term, which is derived by the Chapman-Enskog analysis, is added into the MRT LB equation so that the Navier-Stokes equations can be exactly recovered. Also, a new form of the equilibrium density distribution function is used to simplify the source term. To validate the proposed model, steady flows of a static droplet and the layered channel flow are first simulated with density ratios up to 1000. Small values of spurious velocities and interfacial tension errors are found in the static droplet test, and improved profiles of velocity are obtained by the present model in simulating channel flows. Then, two cases of unsteady flows, Rayleigh-Taylor instability and droplet splashing on a thin film, are simulated. In the former case, the density ratio of 3 and Reynolds numbers of 256 and 2048 are considered. The interface shapes and spike/bubble positions are in good agreement with the results of previous studies. In the latter case, the droplet spreading radius is found to obey the power law proposed in previous studies for the density ratio of 100 and Reynolds number up to 500.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STANDARDIZATION OF CEBAF 12 GEV UPGRADE CAVITY TESTING

CEBAF 12GeV upgrade project includes 80 new 7-cell cavities to form 10 cryomodules. Each cavity underwent RF qualification at 2.07K using a high power accelerating gradient test and an HOM survey in Jefferson Lab's Vertical Testing Area (VTA) before cavity string assembly. In order to ensure consistently high quality data, updated cavity testing procedures and analysis were implemented and used by a group of VTA operators. For high power tests, a cavity testing procedure was developed and used in conjunction with a LabVIEW program to collect the test data. Additionally while the cavity was at 2.07K, an HOM survey was performed using a network analyzer and a combination of Excel and Mathematica programs. Data analysis was standardized and an online logbook, Pansophy, was used for data storage and mining. The Pansophy system allowed test results to be easily summarized and searchable across all cavity tests. In this presentation, the CEBAF 12GeV upgrade cavity testing procedure, method for data analysis, and results reporting results will be discussed.

43 PARTICLE ACCELERATORS↗

Global gyrokinetic simulations of the H-mode tokamak edge pedestal

Global gyrokinetic simulations of DIII-D H-mode edge pedestal show two types of instabilities may exist approaching the onset of edge localized modes: an intermediate-n, high frequency mode which we identify as the “kinetic peeling ballooning mode (KPBM),” and a high-n, low frequency mode. Our previous study [W. Wan et al., Phys. Rev. Lett. 109, 185004 (2012)] has shown that when the safety factor profile is flattened around the steep pressure gradient region, the high-n mode is clearly kinetic ballooning mode and becomes the dominant instability. Otherwise, the KPBM dominates. Here, the properties of the two instabilities are studied by varying the density and temperature profiles. It is found that the KPBM is destabilized by density and ion temperature gradient, and the high-n mode is mostly destabilized by electron temperature gradient. Nonlinear simulations with the KPBM saturate at high levels. The equilibrium radial electric field (E{sub r}) reduces the transport. The effect of the parallel equilibrium current is found to be weak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distortion-free magnetic resonance imaging in the zero-field limit

MRI is a powerful technique for clinical diagnosis and materials characterization. Images are acquired in a homogeneous static magnetic field much higher than the fields generated across the field of view by the spatially encoding field gradients. Without such a high field, the concomitant components of the field gradient dictated by Maxwell's equations lead to severe distortions that make imaging impossible with conventional MRI encoding. In this paper, we present a distortion-free image of a phantom acquired with a fundamentally different methodology in which the applied static field approaches zero. Our technique involves encoding with pulses of uniform and gradient field, and acquiring the magnetic field signals with a SQUID. The method can be extended to weak ambient fields, potentially enabling imaging in the Earth's field without cancellation coils or shielding. Other potential applications include quantum information processing and fundamental studies of long-range ferromagnetic interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of Dissimilar Metal Welding for the NGNP Helical-Coil Steam Generator

The U.S. Department of Energy (DOE) is currently funding research and development of a new high temperature gas cooled reactor (HTGR) that is capable of providing high temperature process heat for industry. The steam generator of the HTGR will consist of an evaporator economizer section in the lower portion and a finishing superheater section in the upper portion. Alloy 800H is expected to be used for the superheater section, and 2.25Cr 1Mo steel is expected to be used for the evaporator economizer section. Dissimilar metal welds (DMW) will be needed to join these two materials. It is well known that failure of DMWs can occur well below the expected creep life of either base metal and well below the design life of the plant. The failure time depends on a wide range of factors related to service conditions, welding parameters, and alloys involved in the DMW. The overall objective of this report is to review factors associated with premature failure of DMWs operating at elevated temperatures and identify methods for extending the life of the 2.25Cr 1Mo steel to alloy 800H welds required in the new HTGR. Information is provided on a variety of topics pertinent to DMW failures, including microstructural evolution, failure mechanisms, creep rupture properties, aging behavior, remaining life estimation techniques, effect of environment on creep rupture properties, best practices, and research in progress to improve DMW performance. The microstructure of DMWs in the as welded condition consists of a sharp chemical concentration gradient across the fusion line that separates the ferritic and austenitic alloys. Upon cooling from the weld thermal cycle, a band of martensite forms within this concentration gradient due to high hardenability and the relatively rapid cooling rates associated with welding. Upon aging, during post weld heat treatment (PWHT), and/or during high temperature service, C diffuses down the chemical potential gradient from the ferritic 2.25Cr 1Mo steel toward the austenitic alloy. This can lead to formation of a soft C denuded zone near the interface on the ferritic steel, and nucleation and growth of carbides on the austenitic side that are associated with very high hardness. These large differences in microstructure and hardness occur over very short distances across the fusion line (~ 50 100 ?m). A band of carbides also forms along the fusion line in the ferritic side of the joint. The difference in hardness across the fusion line increases with increasing aging time due to nucleation and growth of the interfacial carbides. Premature failure of DMWs is generally attributed to several primary factors, including: the sharp change in microstructure and mechanical properties across the fusion line, the large difference in coefficient of thermal expansion (CTE) between the ferritic and austenitic alloys, formation of interfacial carbides that lead to creep cavity formation, and preferential oxidation of the ferritic steel near the fusion line. In general, the large gradient in mechanical properties and CTE serve to significantly concentrate the stress along the fusion where a creep susceptible microstructure has evolved during aging. Presence of an oxide notch can concentrate the stress even further. Details of the failure mechanism and the relative importance of each factor varies.

2.25Cr-1Mo↗