Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Wnt interaction and extracellular release of prominin-1/CD133 in human malignant melanoma cells

Prominin-1 (CD133) is the first identified gene of a novel class of pentaspan membrane glycoproteins. It is expressed by various epithelial and non-epithelial cells, and notably by stem and cancer stem cells. In non-cancerous cells such as neuro-epithelial and hematopoietic stem cells, prominin-1 is selectively concentrated in plasma membrane protrusions, and released into the extracellular milieu in association with small vesicles. Previously, we demonstrated that prominin-1 contributes to melanoma cells pro-metastatic properties and suggested that it may constitute a molecular target to prevent prominin-1-expressing melanomas from colonizing and growing in lymph nodes and distant organs. Here, we report that three distinct pools of prominin-1 co-exist in cultures of human FEMX-I metastatic melanoma. Morphologically, in addition to the plasma membrane localization, prominin-1 is found within the intracellular compartments, (e.g., Golgi apparatus) and in association with extracellular membrane vesicles. The latter prominin-1–positive structures appeared in three sizes (small, ≤40 nm; intermediates ∼40–80 nm, and large, >80 nm). Functionally, the down-regulation of prominin-1 in FEMX-I cells resulted in a significant reduction of number of lipid droplets as observed by coherent anti-Stokes Raman scattering image analysis and Oil red O staining, and surprisingly in a decrease in the nuclear localization of beta-catenin, a surrogate marker of Wnt activation. Moreover, the T-cell factor/lymphoid enhancer factor (TCF/LEF) promoter activity was 2 to 4 times higher in parental than in prominin-1-knockdown cells. Collectively, our results point to Wnt signaling and/or release of prominin-1–containing membrane vesicles as mediators of the pro-metastatic activity of prominin-1 in FEMX-I melanoma. - Highlights: ► First report of release of prominin-1–containing microvesicles from cancer cells. ► Pro-metastatic role of prominin-1–containing microvesicles in FEMX-I melanoma. ► Down-regulation of prominin-1 results in decreased nuclear localization of β-catenin. ► Wnt signaling as mediator of the pro-metastatic activity of prominin-1.

60 APPLIED LIFE SCIENCES↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-19A-01: An Open Source Software for Proton Treatment Planning in Heterogeneous Medium

Purpose: Due to its success in Radiation Oncology during the last decade, interest in proton therapy is on the rise. Unfortunately, despite the global enthusiasm in the field, there is presently no free, multiplatform and customizable Treatment Planning System (TPS) providing proton dose distributions in heterogenous medium. This restricts substantially the progress of clinical research for groups without access to a commercial Proton TPS. The latest implementation of our pencil beam dose calculation algorithm for proton beams within the 3D Slicer open-source environment fulfills all the conditions described above. Methods: The core dose calculation algorithm is based on the Hong algorithm (1), which was upgraded with the Kanematsu theory describing the evolution of the lateral scattering of proton beamlets in heterogeneous medium. This algorithm deals with both mono-energetic beams and Spread Out Bragg Peak (SOBP). In order to be user-friendly, we provide a graphical user interface implemented with the Qt libraries, and visualization with the 3D Slicer medical image analysis software. Two different pencil beam algorithms were developed, and the clinical proton beam line at our facility was modeled. Results: The dose distributions provided by our algorithms were compared to dose distributions coming from both commercialized XiO TPS and literature (dose measurements, GEANT4 and MCNPx) and turned out to be in a good agreement, with maximum dose discrepancies of 5% in homogeneous phantoms and 10% in heterogeneous phantoms. The algorithm of SOBP creation from an optimized weigthing of mono-energetic beams results in flat SOBP. Conclusion: We hope that our efforts in implementing this new, open-source proton TPS will help the research groups to have a free access to a useful, reliable proton dose calculation software.(1) L. Hong et al., A pencil beam algorithm for proton dose calculations, Phys. Med. Biol. 41 (1996) 1305–1330. This project is paid for by NCI/MGH Federal share as a research grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling reactive microscopy with MicroMator

Microscopy image analysis has recently made enormous progress both in terms of accuracy and speed thanks to machine learning methods and improved computational resources. This greatly facilitates the online adaptation of microscopy experimental plans using real-time information of the observed systems and their environments. Applications in which reactiveness is needed are multifarious. Here we report MicroMator, an open and flexible software for defining and driving reactive microscopy experiments. It provides a Python software environment and an extensible set of modules that greatly facilitate the definition of events with triggers and effects interacting with the experiment. We provide a pedagogic example performing dynamic adaptation of fluorescence illumination on bacteria, and demonstrate MicroMator’s potential via two challenging case studies in yeast to single-cell control and single-cell recombination, both requiring real-time tracking and light targeting at the single-cell level.

47 OTHER INSTRUMENTATION↗

The Determination of the Spatial Distribution of Indigenous Lipid Biomarkers in an Immature Jurassic Sediment Using Time-of-Flight–Secondary Ion Mass Spectrometry

The ability to detect and map lipids, including potential lipid biomarkers, within a sedimentary matrix using mass spectrometry (MS) imaging may be critical to determine whether potential lipids detected in samples returned from Mars are indigenous to Mars or are contaminants. Here, we use gas chromatography–mass spectrometry (GC-MS) and time-of-flight–secondary ion mass spectrometry (ToF-SIMS) datasets collected from an organic-rich, thermally immature Jurassic geologic sample to constrain MS imaging analysis of indigenous lipid biomarkers in geologic samples. GC-MS data show that the extractable fractions are dominated by C 27 –C 30 steranes and sterenes as well as isorenieratene derivatives. ToF-SIMS spectra from organic matter-rich laminae contain a strong, spatially restricted signal for ions m/z 370.3, m/z 372.3, and m/z 386.3, which we assign to C 27 sterenes, cholestane (C 27 ), and 4- or 24-methyl steranes (C 28 ), respectively, as well as characteristic fragment ions of isorenieratene derivatives, including m/z 133.1, m/z 171.1, and m/z 237.1. We observed individual steroid spatial heterogeneity at the scale of 10's to 100's of microns. The fine-scale heterogeneity observed implies that indigenous lipid biomarkers concentrated within specific regions may be detectable via ToF-SIMS in samples with even low amounts of organic carbon, including in samples returned from Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Roughness, Porosity and Thermal Resistances of Continuous Casting Mold Slag Layers Devitrified and Crystallized in Laboratory

This paper presents an experimental investigation about the variation, with temperature, of surface roughness, porosity, degree of crystallization and microstructure, occurring in solid layers of a commercial mold powder slag used for casting medium carbon steel thin slabs. Characterization is done with samples devitrified and crystallized at 698 K, 823 K, 898 K and 973 K (425 °C, 550 °C, 625 °C and 700 °C) for 10,800 seconds, in the furnace of a high-temperature confocal laser scanning microscope. As well as, with slag disks devitrified non-isothermally in a heat flow apparatus based on the application of Fourier's law in steady state conditions, where the high temperature surface is maintained at selected values, between 927 K and 1241 K (654 °C and 968 °C). Surface roughness and porosity determinations are performed by image analysis of confocal laser scanning and scanning electron micrographs, respectively. For the time considered and temperatures ≥ 823 K (550 °C) the slag crystallizes completely, and variations of roughness and porosity with temperature are associated with changes in size and packing of the primary crystalline-phase grains. Crystallization induced porosity is significant and causes slag layer expansion. Hence crystallization does not lead to gap formation with a neighboring surface (e.g., mold wall) by shrinkage. Instead, surface separation arises from development of roughness, and measurements with the heat flow apparatus confirm that interfacial thermal resistance between a slag layer and a metallic wall can be estimated from the sum of the means of maximum peak to valley height of their surfaces. Furthermore, the results establish that slag layers roughness and porosity increase with temperature and reveal effective thermal conductivities in the range of ~ 0.3 to ~ 0.5 W/m K. Low effective thermal conductivities must be a consequence of porous bands, whose porosity depends on temperature and reaches values as high as ~ 0.20 and ~ 0.50.

36 MATERIALS SCIENCE↗

Distinct symmetry and limited peptide refolding activity of the thermosomes from the acidothermophilic archaea Acidianus tengchongensis S5{sup T}

Recombinant thermosomes from the Acidianus tengchongensis strain S5{sup T} were purified to homogeneity and assembled in vitro into homo-oligomers (rATcpn{alpha} or rATcpn{beta}) and hetero-oligomers (rATcpn{alpha}{beta}). The symmetries of these complexes were determined by electron microscopy and image analysis. The rATcpn{alpha} homo-oligomer was shown to possess 8-fold symmetry while both rATcpn{beta} and rATcpn{alpha}{beta} oligomers adopted 9-fold symmetry. rATcpn{alpha}{beta} oligomers were shown to contain the {alpha} and {beta} subunits in a 1:2 ratio. All of the complexes prevented the irreversible inactivation of yeast alcohol dehydrogenase at 55 {sup o}C and completely prevented the formation of aggregates during thermal inactivation of citrate synthase at 45 {sup o}C. All rATcpn complexes showed trace ATP hydrolysis activity. Furthermore, rATcpn{beta} sequestered fully chemically denatured substrates (GFP and thermophilic malic dehydrogenase) in vitro without refolding them in an ATP-dependent manner. This property is similar to previously reported properties of chaperonins from Sulfolobus tokodaii and Sulfolobus acidocaldarius. These features are consistent with the slow growth rates of these species of archaea in their native environment.

60 APPLIED LIFE SCIENCES↗

Characterization of the porous structures of the green body and sintered biomedical titanium scaffolds with micro-computed tomography

The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures with various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.

36 MATERIALS SCIENCE↗

Interactive lung segmentation in abnormal human and animal chest CT scans

Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in challenging chest CT images. Both systems do not require prior knowledge of the scans under consideration and work on a variety of scans.

60 APPLIED LIFE SCIENCES↗

Measurement of Photovoltaic Module Deformation Dynamics During Hail Impact Using Digital Image Correlation

Stereo high-speed video of photovoltaic modules undergoing laboratory hail tests was processed using digital image correlation to determine module surface deformation during and immediately following impact. The purpose of this work was to demonstrate a methodology for characterizing module impact response differences as a function of construction and incident hail parameters. Video capture and digital image analysis were able to capture out-of-plane module deformation to a resolution of ±0.1 mm at 11 kHz on an in-plane grid of 10 × 10 mm over the area of a 1 × 2 m commercial photovoltaic module. With lighting and optical adjustments, the technique was adaptable to arbitrary module designs, including size, backsheet color, and cell interconnection. Furthermore, impacts were observed to produce an initially localized dimple in the glass surface, with peak deflection proportional to the square root of incident energy. Subsequent deformation propagation and dissipation were also captured, along with behavior for instances when the module glass fractured. Natural frequencies of the module were identifiable by analyzing module oscillations postimpact. Limitations of the measurement technique were that the impacting ice ball obscured the data field immediately surrounding the point of contact, and both ice and glass fracture events occurred within 100 μs, which was not resolvable at the chosen frame rate. Increasing the frame rate and visualizing the back surface of the impact could be applied to avoid these issues. Applications for these data include validating computational models for hail impacts, identifying the natural frequencies of a module, and identifying damage initiation mechanisms.

14 SOLAR ENERGY↗

Disky elliptical galaxies and the allegedly over-massive black hole in the compact massive “es” galaxy NGC 1271

While spiral and lenticular galaxies have large-scale disks extending beyond their bulges, and most local early-type galaxies with 10{sup 10} < M {sub *}/M {sub ⊙} < 2 × 10{sup 11} contain a disk (e.g., ATLAS{sup 3D}), the early-type galaxies do possess a range of disk sizes. The edge-on, intermediate-scale disk in the “disky elliptical” galaxy NGC 1271 has led to some uncertainty regarding its spheroidal component. Walsh et al. reported a directly measured black hole mass of (3.0{sub −1.1}{sup +1.0})×10{sup 9} M{sub ⊙} for this galaxy, which they remarked was an order of magnitude greater than what they expected based on their derivation of the host spheroid’s luminosity. Our near-infrared image analysis supports a small embedded disk within a massive spheroidal component with M{sub sph,∗}=(0.9±0.2)×10{sup 11} M{sub ⊙} (using M{sub ∗}/L{sub H}=1.4{sub −0.11}{sup +0.13} from Walsh et al.). This places NGC 1271 just 1.6σ above the near-linear M {sub bh}–M {sub sph,*} relation for early-type galaxies. Therefore, past speculation that there may be a systematic difference in the black hole scaling relations between compact massive early-type galaxies with intermediate-scale disks, i.e., ES galaxies such as NGC 1271, and early-type galaxies with either no substantial disk (E) or a large-scale disk (S0) is not strongly supported by NGC 1271. We additionally (1) show how ES galaxies fit naturally in the (“bulge”-to-total)-(morphological-type) diagram, while noting a complication with recent revisions to the Hubble-Jeans tuning-fork diagram, (2) caution about claims of over-massive black holes in other ES galaxies if incorrectly modeled as S0 galaxies, and (3) reveal that the compact massive spheroid in NGC 1271 has properties similar to bright bulges in other galaxies, which have grown larger-scale disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasar variability in the mid-infrared

The Decadal IRAC Boötes Survey is a mid-IR variability survey of the ∼9 sq. deg. of the NDWFS Boötes Field and extends the time baseline of its predecessor, the Spitzer Deep, Wide-Field Survey (SDWFS), from 4 to 10 years. The Spitzer Space Telescope visited the field five times between 2004 and 2014 at 3.6 and 4.5 μm. We provide the difference image analysis photometry for a half a million mostly extragalactic sources. In mid-IR color–color plane, sources with quasar colors constitute the largest variability class (75%), 16% of the variable objects have stellar colors and the remaining 9% have the colors of galaxies. Adding the fifth epoch doubles the number of variable active galactic nuclei (AGNs) for the same false positive rates as in SDWFS, or increases the number of sources by 20% while decreasing the false positive rates by factors of 2–3 for the same variability amplitude. We quantify the ensemble mid-IR variability of ∼1500 spectroscopically confirmed AGNs using single power-law structure functions (SFs), which we find to be steeper (index γ≈0.45) than in the optical (γ≈0.3), leading to much lower amplitudes at short time-lags. This provides evidence for large emission regions, smoothing out any fast UV/optical variations, as the origin of infrared quasar variability. The mid-IR AGN SF slope γ seems to be uncorrelated with both the luminosity and rest-frame wavelength, while the amplitude shows an anti-correlation with the luminosity and a correlation with the rest-frame wavelength.

79 ASTRONOMY AND ASTROPHYSICS↗

Lack of Radiation Dose or Quality Dependence of Epithelial-to-Mesenchymal Transition (EMT) Mediated by Transforming Growth Factor {beta}

Purpose: Epithelial-to-mesenchymal transition (EMT) is a phenotype that alters cell morphology, disrupts morphogenesis, and increases motility. Our prior studies have shown that the progeny of human mammary epithelial cells (HMECs) irradiated with 2 Gy undergoes transforming growth factor {beta} (TGF-{beta})-mediated EMT. In this study we determined whether radiation dose or quality affected TGF-{beta}-mediated EMT. Methods and Materials: HMECs were cultured on tissue culture plastic or in Matrigel (BD Biosciences, San Jose, CA) and exposed to low or high linear energy transfer (LET) and TGF-{beta} (400 pg/mL). Image analysis was used to measure membrane-associated E-cadherin, a marker of functional epithelia, or fibronectin, a product of mesenchymal cells, as a function of radiation dose and quality. Results: E-cadherin was reduced in TGF-{beta}-treated cells irradiated with low-LET radiation doses between 0.03 and 2 Gy compared with untreated, unirradiated cells or TGF-{beta} treatment alone. The radiation quality dependence of TGF-{beta}-mediated EMT was determined by use of 1 GeV/amu (gigaelectron volt / atomic mass unit) {sup 56}Fe ion particles at the National Aeronautics and Space Administration's Space Radiation Laboratory. On the basis of the relative biological effectiveness of 2 for {sup 56}Fe ion particles' clonogenic survival, TGF-{beta}-treated HMECs were irradiated with equitoxic 1-Gy {sup 56}Fe ion or 2-Gy {sup 137}Cs radiation in monolayer. Furthermore, TGF-{beta}-treated HMECs irradiated with either high- or low-LET radiation exhibited similar loss of E-cadherin and gain of fibronectin and resulted in similar large, poorly organized colonies when embedded in Matrigel. Moreover, the progeny of HMECs exposed to different fluences of {sup 56}Fe ion underwent TGF-{beta}-mediated EMT even when only one-third of the cells were directly traversed by the particle. Conclusions: Thus TGF-{beta}-mediated EMT, like other non-targeted radiation effects, is neither radiation dose nor quality dependent at the doses examined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MID-INFRARED VARIABILITY FROM THE SPITZER DEEP WIDE-FIELD SURVEY

We use the multi-epoch, mid-infrared Spitzer Deep Wide-Field Survey to investigate the variability of objects in 8.1 deg{sup 2} of the NOAO Deep Wide Field Survey Booetes field. We perform a Difference Image Analysis of the four available epochs between 2004 and 2008, focusing on the deeper 3.6 and 4.5 {mu}m bands. Out of 474, 179 analyzed sources, 1.1% meet our standard variability selection criteria that the two light curves are strongly correlated (r>0.8) and that their joint variance ({sigma}{sub 12}) exceeds that for all sources with the same magnitude by 2{sigma}. We then examine the mid-IR colors of the variable sources and match them with X-ray sources from the XBooetes survey, radio catalogs, 24 {mu}m selected active galactic nucleus (AGN) candidates, and spectroscopically identified AGNs from the AGN and Galaxy Evolution Survey (AGES). Based on their mid-IR colors, most of the variable sources are AGNs (76%), with smaller contributions from stars (11%), galaxies (6%), and unclassified objects, although most of the stellar, galaxy, and unclassified sources are false positives. For our standard selection criteria, 11%-12% of the mid-IR counterparts to X-ray sources, 24 {mu}m AGN candidates, and spectroscopically identified AGNs show variability. The exact fractions depend on both the search depth and the selection criteria. For example, 12% of the 1131 known z>1 AGNs in the field and 14%-17% of the known AGNs with well-measured fluxes in all four Infrared Array Camera bands meet our standard selection criteria. The mid-IR AGN variability can be well described by a single power-law structure function with an index of {gamma} {approx} 0.5 at both 3.6 and 4.5 {mu}m, and an amplitude of S {sub 0} {approx_equal} 0.1 mag on rest-frame timescales of 2 yr. The variability amplitude is higher for shorter rest-frame wavelengths and lower luminosities.

79 ASTRONOMY AND ASTROPHYSICS↗

Persistence of bubble outlets in soft, methane-generating sediments

Sediments submerged beneath many inland waterways and shallow oceans emit methane, a potent greenhouse gas, but the magnitude of the methane flux to the atmosphere remains poorly constrained. In many settings, the majority of methane is released through bubbling, and the spatiotemporal heterogeneity of this ebullition both presents challenges for measurement and impacts bubble dissolution and atmospheric emissions. In this paper, we present laboratory-scale experiments of methane ebullition in a controlled incubation of reconstituted sediments from a eutrophic lake. Image analysis of a 0.14 m 2 sediment surface area allowed identification of individual bubble outlets and resolved their location to ~1 cm. While ebullition events were typically concentrated in bursts lasting ~2 min, some major outlets showed persistent activity over the scale of days and even months. This persistence was surprising given the previously observed ephemerality of spatial structure at the field scale. This persistence suggests that, at the centimeter scale, conduits are reopened as a result of a drop in tensile strength due to deformation of sediments by the rising bubbles. Finally, the mechanistic insight from this work sheds light on the spatiotemporal distribution of methane venting from organic-rich sediments and has important implications for bubble survival in the water column and associated biogeochemical pathways of methane.

58 GEOSCIENCES↗

IMPACT OF PARTICLE AGGLOMERATION ON ACCUMULATION RATES IN THE GLASS DISCHARGE RISER OF HLW MELTER

The major factor limiting waste loading in continuous high-level radioactive waste (HLW) melters is an accumulation of particles in the glass discharge riser during a frequent and periodic idling of more than 20 days. An excessive accumulation can produce robust layers a few centimeters thick, which may clog the riser, preventing molten glass from being poured into canisters. Since the accumulation rate is driven by the size of particles we investigated with X-ray microtomography, scanning electron microscopy, and image analysis the impact of spinel forming components, noble metals, and alumina on the size, concentration, and spatial distribution of particles, and on the accumulation rate. Increased concentrations of Fe and Ni in the baseline glass resulted in the formation of large agglomerates that grew over the time to an average size of ~185±155 µm, and produced >3 mm thick layer after 120 h at 850 °C. The noble metals decreased the particle size, and therefore significantly slowed down the accumulation rate. Addition of alumina resulted in the formation of a network of spinel dendrites which prevented accumulation of particles into compact layers.

Accumulation↗