Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

NASA’s Quiet Electric ENgines (QUEEN): Summary of the Acoustic Tests of the QUEEN V1

Noise produced by an electric ducted fan system was measured in tests at the NASA Glenn Research Center Acoustical Testing Laboratory. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, an Electronic Speed Controller, a custom-designed inlet bellmouth, and several experimental inlet duct acoustic liners. Fan speed, thrust, and noise were measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large regional single-aisle aircraft. Lessons learned will be used to guide development of future QUEEN prototypes. Results of a thermal test of the Electronic Speed Controller measured during this test are presented in a separate report.

L Danielle Koch↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the Acoustic Tests of the QUEEN V1

Noise produced by an electric ducted fan system was measured in tests at the NASA Glenn Research Center Acoustical Testing Laboratory. Main components of the system include a Commercial-Off-the-Shelf fan, shroud, motor, and Electronic Speed Controller, plus a custom-designed inlet bellmouth, and four experimental inlet duct acoustic liners. Fan speed and noise were measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large single-aisle aircraft. Results indicated that inlet duct acoustic liners reduced tone and broadband noise as compared to a hardwall inlet duct. Predicted performance of the honeycomb liner compared well with measurements from an array of far field microphones. Inlet acoustic liners are just one method for mitigating noise for electric ducted fans for aircraft propulsion systems. Lessons learned will be used to guide development of future QUEEN prototypes. Results of a thermal test of the Electronic Speed Controller are presented in a separate report.

Aircraft propulsion and power↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the Acoustic Tests of the QUEEN V1

Noise produced by an electric ducted fan system was measured in tests at the NASA Glenn Research Center Acoustical Testing Laboratory. Main components of the system include a Commercial-Off-the-Shelf fan, shroud, motor, and Electronic Speed Controller, plus a custom-designed inlet bellmouth, and four experimental inlet duct acoustic liners. Fan speed and noise were measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large single-aisle aircraft. Results indicated that inlet duct acoustic liners reduced tone and broadband noise as compared to a hardwall inlet duct. Predicted performance of the honeycomb liner compared well with measurements from an array of far field microphones. Inlet acoustic liners are just one method for mitigating noise for electric ducted fans for aircraft propulsion systems. Lessons learned will be used to guide development of future QUEEN prototypes. Results of a thermal test of the Electronic Speed Controller are presented in a separate report.

Aircraft propulsion and power↗

Direct Measurements of Infrared Intensities of HCN and H2O + HCN Ices for Laboratory and Observational Astrochemistry

Hydrogen cyanide (HCN) is found in a wide variety of extraterrestrial environments within and beyond the solar system, and for that reason laboratory spectroscopists have studied this compound in many spectral regions, including the infrared (IR). However, one aspect that remains to be investigated is the intrinsic IR spectral intensities of solid HCN as opposed to relative band strengths, intrinsic intensities being needed to measure HCN abundances. Here we report measurements of IR absorption coefficients and band strengths, along with supporting refractive indices and densities, of both amorphous and crystalline HCN at two temperatures, one for interstellar work and one more relevant to the outer solar system. Spectra are presented at both temperatures, along with optical constants that can be used in numerical models. Despite widespread and longstanding interest in and investigations of solid HCN, this is the first time that the properties we are reporting have been measured in a single laboratory, avoiding the need for estimates or to combine results from various authors. We find that our measured band strength of ~1 × 1017 cm molecule1 for the CN vibration of HCN, in both amorphous HCN and in an H2O-rich ice, is substantially higher than an earlier estimate. Unless errors of 100% can be tolerated then our new value requires a rescaling of earlier work. Our results shed light on why HCN and other nitriles have been so difficult to identify in the solid state, in contrast to their many detections in the gas phase.

astrochemistry – methods: laboratory – solid state↗

Direct Measurements of Infrared Intensities of HCN and H2O + HCN Ices for Laboratory and Observational Astrochemistry

Hydrogen cyanide (HCN) is found in a wide variety of extraterrestrial environments within and beyond the solar system, and for that reason laboratory spectroscopists have studied this compound in many spectral regions, including the infrared (IR). However, one aspect that remains to be investigated is the intrinsic IR spectral intensities of solid HCN as opposed to relative band strengths, intrinsic intensities being needed to measure HCN abundances. Here we report measurements of IR absorption coefficients and band strengths, along with supporting refractive indices and densities, of both amorphous and crystalline HCN at two temperatures, one for interstellar work and one more relevant to the outer solar system. Spectra are presented at both temperatures, along with optical constants that can be used in numerical models. Despite widespread and longstanding interest in and investigations of solid HCN, this is the first time that the properties we are reporting have been measured in a single laboratory, avoiding the need for estimates or to combine results from various authors. We find that our measured band strength of ~1 × 1017 cm molecule1 for the CN vibration of HCN, in both amorphous HCN and in an H2O-rich ice, is substantially higher than an earlier estimate. Unless errors of 100% can be tolerated then our new value requires a rescaling of earlier work. Our results shed light on why HCN and other nitriles have been so difficult to identify in the solid state, in contrast to their many detections in the gas phase.

astrochemistry – methods: laboratory – solid state↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

A design study of a photorefractive page composer

A laboratory demonstration and preliminary system analysis of a page composer designed to have the dual advantages of low optical loss and small size, were reported. The current page composer is optically addressed and functions by virtue of optically induced refractive index changes in the active material. Laboratory demonstrations of the device were successfully performed using 10 x 10 bit and 128 x 128 bit data arrays. It was established that the only significant obstacle to the construction of a brass-board model working at megabit data rates is the lack of sensitivity of the photorefractive materials which were considered during the course of this study. Possible materials for future consideration are the photoplastics. While they have more than the required sensitivity, their stability and suitability for double exposure holography was not investigated. If a sufficiently sensitive material is found, then the photorefractive page composer could be built to perform in a highly efficient fashion which would result in a overall reduction of the size of the memory system and an easing of the requirements upon the sensitivity of the holographic recording material.

Source record↗

Flow Control and Measurement in Electric Propulsion Systems: Towards an AIAA Reference Standard

Accurate control and measurement of propellant flow to a thruster is one of the most basic and fundamental requirements for operation of electric propulsion systems, whether they be in the laboratory or on flight spacecraft. Hence, it is important for the electric propulsion community to have a common understanding of typical methods for flow control and measurement. This paper addresses the topic of propellant flow primarily for the gaseous propellant systems which have dominated laboratory research and flight application over the last few decades, although other types of systems are also briefly discussed. While most flight systems have employed a type of pressure-fed flow restrictor for flow control, both thermal-based and pressure-based mass flow controllers are routinely used in laboratories. Fundamentals and theory of operation of these types of controllers are presented, along with sources of uncertainty associated with their use. Methods of calibration and recommendations for calibration processes are presented. Finally, details of uncertainty calculations are presented for some common calibration methods and for the linear fits to calibration data that are commonly used.

thrust measurement↗

On the universality of microlensing in quadruple gravitational lenses

It is well known that multiply imaged quasars are likely to be affected by microlensing. Quadruply imaged systems are especially useful laboratories for studying microlensing because their macrolens models are relatively well constrained. We begin with analytical results for a simple family of galaxy models. These results can be used to estimate the magnifications and time delays for the quadruple systems. We compute expected brightness fluctuations due to microlensing in several such systems for a range of source sizes. Among these we treat for the first time the limiting case of a completely unresolved source. For the case of MG 0414+0534 we interpret the discrepant optical-to-radio flux ratios for the different components as the result of microlensing. On the assumption that the lensing galaxy is roughly isothermal this gives a 95% confidence upper limit on the optical source size of 10(exp 16) cm x (mean value of M)/0.1 solar mass(exp 1/2) where (M) is the average stellar mass of the lensing galaxy. For more centrally concentrated macromodels the upper limit is greater. Sufficiently long strings of photometric observations can in principle constrain the degree of concentration.

Witt, Hans J.↗

Laboratory Velocimeter Measurements Using the Edge Technique

We have developed a simple but powerful measurement methodology using the edge technique to measure the Doppler shift of backscatter laser radiation. With this method, instantaneous velocity information, including wind measurements, can be obtained with sub-meter-per-second accuracy and with high range resolution using a pulsed lidar system. This paper describes laboratory experiments that demonstrate the basic principles of the edge technique. These experiments demonstrate the sensitivity of the technique and the high velocity accuracy which can be obtained. In addition, many of the characteristics which make the edge technique a powerful method for use in lidar wind application were verified. These include the insensitivity of the measurement to laser and/or edge filter frequency jitter and drift, and the ability to make Doppler shift measurements which are of the order of 100 times better than the spectral bandwidth of the measurement (the combined spectral width of the laser and edge filter).

Gentry, Bruce M.↗

NWP Impact of Cloud Top and Boundary Layer Winds from a Satellite Borne Lidar: an Observing System Simulation Experiment

Observing systems simulation experiments (OSSE's) provide a powerful tool to assess the impact of proposed satellite borne observing systems on meteorological applications models. We describe the results of an OSSE conducted to assess the impact of data from a low power lidar wind sensor on the forecast accuracy of a global spectral numerical weather prediction (NWP) model, the Air Force Geophysics Laboratory Global Data Assimilation System. The instrument would be operating at near-infrared wavelengths thereby increasing the backscatter signal relative to comparable infrared lidar.

Isaacs, R. G.↗

Monte Carlo Computational Modeling of the Energy Dependence of Atomic Oxygen Undercutting of Protected Polymers

A Monte Carlo computational model has been developed which simulates atomic oxygen attack of protected polymers at defect sites in the protective coatings. The parameters defining how atomic oxygen interacts with polymers and protective coatings as well as the scattering processes which occur have been optimized to replicate experimental results observed from protected polyimide Kapton on the Long Duration Exposure Facility (LDEF) mission. Computational prediction of atomic oxygen undercutting at defect sites in protective coatings for various arrival energies was investigated. The atomic oxygen undercutting energy dependence predictions enable one to predict mass loss that would occur in low Earth orbit, based on lower energy ground laboratory atomic oxygen beam systems. Results of computational model prediction of undercut cavity size as a function of energy and defect size will be presented to provide insight into expected in-space mass loss of protected polymers with protective coating defects based on lower energy ground laboratory testing.

Banks, Bruce A.↗

Microbial ecology measurement system

The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

Source record↗

Fabrication of neurophysiological monitoring systems

A system designed to collect electroencephalographic, electro-oculographic, electromyographic, and head motion data is described. The portable instrumentation provides a rapid and simple means by which neurophysiological data can be obtained by the patient in his home and the taped data returned to the laboratory for analysis. The system was designed primarily for the study of sleep.

Frost, J. D., Jr.↗

Data-Acquisition System With Remotely Adjustable Amplifiers

Improved data-acquisition system has both centralized and decentralized characteristics developed. Provides infrastructure for automation and standardization of operation, maintenance, calibration, and adjustment of many transducers. Increases efficiency by reducing need for diminishing work force of highly trained technicians to perform routine tasks. Large industrial and academic laboratory facilities benefit from systems like this one.

Nurge, Mark A.↗