Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

FY24 Integrated Results for High-Temperature Mechanical Testing of LPBF 316H Stainless Steel

This report provides the mechanical test data of laser powder bed fusion (LPBF) 316H stainless steel (SS) collected during Fiscal Year 2024 (FY 24) under the US Department of Energy, Office of Nuclear Energy’s Advanced Materials and Manufacturing Technologies program, along with the current state of microstructural-based understandings of the behaviors. Materials with variabilities in manufacturing site, machine, laser parameters, powder chemistry, porosity, specimen geometry and heat treatment were tested in high-temperature tension, creep, fatigue and creep-fatigue. Electron microscopy and optical microscopy were performed on selected materials before and after the tests to provide microstructural-based understandings to the mechanical behavior. It was discovered that the as-built (AB) and stress-relieved (SR) materials exhibit similar behaviors in tension and creep, as do the solution-annealed (SA) and hot-isostatic pressed (HIP) materials. The AB and SR materials are softer but more ductile than the SA and HIP materials in tension. In creep, the LPBF materials have comparable rupture times but lower rupture strains compared to the wrought materials. The AB and SR materials have low creep rupture strains (<10%) when tested at 720°C and 800°C, while the SA and HIP materials are much more ductile. The LPBF materials exhibit large scatter in fatigue and creep-fatigue lives. The cyclic lives of creep-fatigue tests are lower than those of fatigue tests. In fatigue and creep-fatigue, SR materials outperform SA materials. A common observation from the cyclic tests is that, given the same post-build heat treatment, a lower initial peak stress generally results in a longer cyclic life regardless of hold time. It was also discovered that the batch variation can be more impactful than heat treatment, as demonstrated by the overall better performance of one batch of material than another, regardless of the heat treatment. The results provided insights into how different factors impact the behaviors of LPBF 316H SS. An outlook to FY 25 work scope is provided.

36 MATERIALS SCIENCE↗

LAB SAFETY: Responding to an Emergency at Berkeley Lab

Berkeley Lab's Protective Services team stages an annual emergency exercise event to test and practice the response and coordination needed for large scale emergency at the lab. The procedures, planning, and training brought to life in these scenarios helps teams become better prepared for an actual event.

99 GENERAL AND MISCELLANEOUS↗

A new experimental testing method for investigation of creep-dominant creep-fatigue interaction in Alloy 617 at 950 °C

An experimental testing procedure is proposed for generating creep-dominant creep-fatigue interaction in Alloy 617 at 950 °C. Most experimental studies on Alloy 617 at elevated temperatures employ a purely strain-controlled loading waveform with a tensile hold period. Strain-controlled loading can only generate interaction in the fatigue-dominant regime of the damage interaction diagram, due to the saturation effect of increasing hold time on cycle life. This saturation is caused by the rapid stress relaxation of Alloy 617 at high temperatures. Design codes for components undergoing creep-fatigue interaction at high temperatures require creep-fatigue testing data in the creep-dominant regime. Here this study investigates multiple creep-fatigue loading waveforms with the objective of producing creep-dominant interaction. The custom loading waveforms are implemented on a servo-hydraulic load frame with a furnace. A hybrid-control scheme with strain-controlled ramps and load-controlled hold periods is proposed due to its flexibility in generating varying proportions of creep and fatigue damage. Experimental data is presented and different loading schemes are compared. Special emphasis is on the creep and fatigue damage contributions by the newly proposed testing method. Several conclusions are discussed and an extension of this current work is suggested to improve the damage interaction diagram for design purposes.

36 MATERIALS SCIENCE↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Innovative Hot Lab Concept for Advanced D and D Application - 19175

Hot Labs are used in the nuclear industry for various purposes: maintenance of nuclear reactor, sampling and testing of fuel, inspection activities and decommissioning. Despite their vast use, their current designs and operations do not meet entirely today's needs and requirements of the operations nor tomorrow's. This paper will give an overview of the research and investigations performed around Hot Cells design and concept in order to integrate new operability modes and functions. The overall idea is to bring modularity, flexibility and adaptability to the Hot Lab nuclear industry. Taking the key principles of Model Based System Engineering, an interoperable data model, the most advanced digital technologies (Building Information Modelling - BIM, Virtual Reality / Augmented Reality, Artificial Intelligence), and looking at all the life-cycle of such a facility, a concept design of a new type of Hot Lab has been developed. Four mains aspects are implemented during this study: Implement the principles of the Industry 4.0; use modular and flexible solutions; explore the concept of in service maintenance and predictive maintenance; optimise the decommissioning and dismantling process by taking into account the entire life-cycle of the facility. The design was developed as a case study taking several assumptions to adapt to any project. The design developed demonstrates that modularity and flexibility can be brought in without compromising the core safety functions of such a facility. This Hot Lab concept brings the current Hot Lab to the next level as the design has been adapted to meet the current operational needs, implement novel ideas and consider its entire life-cycle. This paper will demonstrate how decommissioning and dismantling operations can become more efficient and safer with such a concept. In addition, the Model Based System Engineering approach used from the beginning of the design phase allows to have an optimum architecture during its entire lifetime. It also allowed to flag new topics to be further developed for the benefit of the nuclear industry as a whole. A first example would be the development of the Control System using digital tools and artificial intelligence to run remotely controlled equipment inside the Hot Lab. Assystem is an international engineering group. As a key participant in the nuclear industry for over 50 years, the Group supports its clients in managing their capital expenditure throughout their asset life-cycles. Assystem can offer support in project management, design, digital engineering, industrial control systems, security and safety and industrial digitalisation. Assystem's Imagine program is an internal program intending to serve as an incubator for the development of innovations. The Innovative Hot Lab project integrates one of the four innovation projects Assystem choose to develop and invest in. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Streamlining the Design-to-Build Transition with Build-Optimization Software Tools

Scaling-up capabilities for the design, build, and test of synthetic biology constructs holds great promise for the development of new applications in fuels, chemical production, or cellular-behavior engineering. Construct design is an essential component in this process; however, not every designed DNA sequence can be readily manufactured, even using state-of-the-art DNA synthesis methods. Current biological computer-aided design and manufacture tools (bioCAD/CAM) do not adequately consider the limitations of DNA synthesis technologies when generating their outputs. Designed sequences that violate DNA synthesis constraints may require substantial sequence redesign or lead to price-premiums and temporal delays, which adversely impact the efficiency of the DNA manufacturing process. In this paper, we have developed a suite of build-optimization software tools (BOOST) to streamline the design-build transition in synthetic biology engineering workflows. BOOST incorporates knowledge of DNA synthesis success determinants into the design process to output ready-to-build sequences, preempting the need for sequence redesign. The BOOST web application is available at https://boost.jgi.doe.gov and its Application Program Interfaces (API) enable integration into automated, customized DNA design processes. Finally, the herein presented results highlight the effectiveness of BOOST in reducing DNA synthesis costs and timelines.

59 BASIC BIOLOGICAL SCIENCES↗

Expression and effects of TSP50 in mouse embryo and cardiac myocyte development

Highlights: • TSP50 expression increases during early embryonic development. • TSP50 expression decreases during embryonic heart and P19 myocardial development. • Higher or lower TSP50 causes abnormal zygote and P19 myocardial differentiation. TSP50, a testis-specific gene encoding a serine protease-like protein, was specifically expressed in the spermatocytes of testes but abnormally activated and expressed in many different kinds of cancers. Here, we aimed to analyze the expression of TSP50 in mouse embryo and its function in early embryonic development. Firstly, the distribution of TSP50 in oocytes and embryonic development was characterized by immunofluorescence, RT-PCR and western blotting, and the results showed that TSP50 was detected at all studied stages with a dynamic expression pattern. When overexpressed TSP50 in zygotes by microinjection, the zygotes development was highly accelerated. On the contrary, knocking down TSP50 expression by RNA interference greatly retarded the zygote development. Furthermore, TSP50 expression at embryonic day 6.5 (E6.5), day 8.5 (E8.5) and day 10.5 (E10.5) were increasingly enhanced, However, the expression of TSP50 decreased gradually in the development and differentiation of cardiac myocyte from E12.5 to postnatal (P0). Additionally, we found that TSP50 expression was decreased during cardiac myocyte differentiation of P19 cells. Overexpression of TSP50 could decrease the expression of GATA-4, and knockdown of TSP50 markedly increase the expression of GATA-4. Taken together, our data indicate that TSP50 may play an important role during the process of mouse embryonic development as well as myocardial cell differentiation.

60 APPLIED LIFE SCIENCES↗

The comparison of semiempirical and ab initio molecular modeling methods in activity and property evaluation of selected antimicrobial sulfonamides

A group of sulfonamides exhibiting antimicrobial activity was analyzed with the application of quantitative structure–activity/property relationships method. The purpose of this study was to show the common and differentiating characteristics of the analyzed chemical structures alike physicochemically as well as pharmacologically based on the quantum-chemical calculations both in vacuo and in the aquatic environment together with their microbiological activity and chromatographic retention data. The semiempirical and ab initio level of in silico molecular modeling was performed for calculations of statistically significant molecular descriptors to compare obtained results. The relationship between the structure and biological activity and physicochemical parameters data was able to class and describe analyzed molecules and the applied chemometric approaches (principal component analysis, factor analysis, and multiple regression analysis) revealed the influential features of the tested structures responsible for the antimicrobial activity.

60 APPLIED LIFE SCIENCES↗

Rosiglitazone attenuates inflammation and CA3 neuronal loss following traumatic brain injury in rats

Rosiglitazone, a potent peroxisome proliferator-activated receptor (PPAR)-γ agonist, has been shown to confer neuroprotective effects in stroke and spinal cord injury, but its role in the traumatic brain injury (TBI) is still controversial. Using a controlled cortical impact model in rats, the current study was designed to determine the effects of rosiglitazone treatment (6 mg/kg at 5 min, 6 h and 24 h post injury) upon inflammation and histological outcome at 21 d after TBI. In addition, the effects of rosiglitazone upon inflammatory cytokine transcription, vestibulomotor behavior and spatial memory function were determined at earlier time points (24 h, 1–5 d, 14–20 d post injury, respectively). Compared with the vehicle-treated group, rosiglitazone treatment suppressed production of TNFα at 24 h after TBI, attenuated activation of microglia/macrophages and increased survival of CA3 neurons but had no effect on lesion volume at 21 d after TBI. Rosiglitazone-treated animals had improved performance on beam balance testing, but there was no difference in spatial memory function as determined by Morris water maze. In summary, this study indicates that rosiglitazone treatment in the first 24 h after TBI has limited anti-inflammatory and neuroprotective effects in rat traumatic injury. Further study using an alternative dosage paradigm and more sensitive behavioral testing may be warranted. - Highlights: • Effects of rosiglitazone after CCI were evaluated using a rat TBI model. • Rosiglitazone suppressed production of TNFα at 24 h after CCI. • Rosiglitazone inhibited microglial activation at 21 d after CCI. • Rosiglitazone increased survival of CA3 neurons at 21 d after CCI. • Rosiglitazone-treated animals had improved performance in beam balance testing.

60 APPLIED LIFE SCIENCES↗

Modeling of drug-mediated CYP3A4 induction by using human iPS cell-derived enterocyte-like cells

Many drugs have potential to induce the expression of drug-metabolizing enzymes, particularly cytochrome P450 3A4 (CYP3A4), in small intestinal enterocytes. Therefore, a model that can accurately evaluate drug-mediated CYP3A4 induction is urgently needed. In this study, we overlaid Matrigel on the human induced pluripotent stem cells-derived enterocyte-like cells (hiPS-ELCs) to generate the mature hiPS-ELCs that could be applied to drug-mediated CYP3A4 induction test. By overlaying Matrigel in the maturation process of enterocyte-like cells, the gene expression levels of intestinal markers (VILLIN, sucrase-isomaltase, intestine-specific homeobox, caudal type homeobox 2, and intestinal fatty acid-binding protein) were enhanced suggesting that the enterocyte-like cells were maturated by Matrigel overlay. The percentage of VILLIN-positive cells in the hiPS-ELCs found to be approximately 55.6%. To examine the CYP3A4 induction potential, the hiPS-ELCs were treated with various drugs. Treatment with dexamethasone, phenobarbital, rifampicin, or 1α,25-dihydroxyvitamin D3 resulted in 5.8-fold, 13.4-fold, 9.8-fold, or 95.0-fold induction of CYP3A4 expression relative to that in the untreated controls, respectively. These results suggest that our hiPS-ELCs would be a useful model for CYP3A4 induction test. - Highlights: • The hiPS-ELCs were matured by Matrigel overlay. • The hiPS-ELCs expressed intestinal nuclear receptors, such as PXR, GR and VDR. • The hiPS-ELC is a useful model for the drug-mediated CYP3A4 induction test.

60 APPLIED LIFE SCIENCES↗

Towards replacement of animal tests with in vitro assays: a gene expression biomarker predicts in vitro and in vivo estrogen receptor activity

High-throughput transcriptomics (HTTr) has the potential to support efforts to reduce or replace some animal tests. In past studies, we described a computational approach utilizing a gene expression biomarker consisting of 46 genes to predict estrogen receptor (ER) activity after chemical exposure in ER-positive human breast cancer cells including the MCF-7 cell line. We hypothesized that the biomarker model could identify ER activities of chemicals examined by Endocrine Disruptor Screening Program (EDSP) Tier 1 screening assays in which transcript profiles of the same chemicals were examined in MCF-7 cells. For the 62 chemicals examined including 5 chemicals examined in this study using RNA-Seq, the ER biomarker model accuracy was 1) 97% for in vitro reference chemicals, 2) 76–85% for guideline uterotrophic assays, and 3) 87–88% for guideline and nonguideline uterotrophic assays. For the same chemicals, these accuracies were similar or slightly better than those of the ToxCast ER model based on 18 in vitro assays. The performance of the ER biomarker model indicates that HTTr interpreted using the ER biomarker correctly identifies active and inactive ER reference chemicals. Finally, as part of the HTTr screening program the approach could rapidly identify chemicals with potential ER bioactivities for additional screening and testing.

60 APPLIED LIFE SCIENCES↗

Glutathione-S-transferase A3 knockout mice are sensitive to acute cytotoxic and genotoxic effects of aflatoxin B1

Aflatoxin B1 (AFB1) is a major risk factor for hepatocellular carcinoma (HCC) in humans. However, mice, a major animal model for the study of AFB1 carcinogenesis, are resistant, due to high constitutive expression, in the mouse liver, of glutathione S-transferase A3 subunit (mGSTA3) that is lacking in humans. Our objective was to establish that a mouse model for AFB1 toxicity could be used to study mechanisms of toxicity that are relevant for human disease, i.e., an mGSTA3 knockout (KO) mouse that responds to toxicants such as AFB1 in a manner similar to humans. Exons 3-6 of the mGSTA3 were replaced with a neomycin cassette by homologous recombination. Southern blotting, RT-PCR, Western blotting, and measurement of AFB1-N{sup 7}-DNA adduct formation were used to evaluate the mGSTA3 KO mice. The KO mice have deletion of exons 3-6 of the mGSTA3 gene, as expected, as well as a lack of mGSTA3 expression at the mRNA and protein levels. Three hours after injection of 5 mg/kg AFB1, mGSTA3 KO mice have more than 100-fold more AFB1-N{sup 7}-DNA adducts in their livers than do similarly treated wild-type (WT) mice. In addition, the mGSTA3 KO mice die of massive hepatic necrosis, at AFB1 doses that have minimal toxic effects in WT mice. We conclude that mGSTA3 KO mice are sensitive to the acute cytotoxic and genotoxic effects of AFB1, confirming the crucial role of GSTA3 subunit in protection of normal mice against AFB1 toxicity. We propose the mGSTA3 KO mouse as a useful model with which to study the interplay of risk factors leading to HCC development in humans, as well as for testing of additional possible functions of mGSTA3.

60 APPLIED LIFE SCIENCES↗

SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial interests with the commercialization of this QA device.

07 ISOTOPE AND RADIATION SOURCES↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

Extremely Early Diagnostic Test for Prostate Cancer

This article reports the results of a blinded fiber diffraction study of skin samples taken from TRAMP mice and age-matched controls to determine whether changes noted in fiber diffraction studies of human skin were present in these TRAMP mice studies. These mice are bred to progress to Gleeson Type 3 to Type 5 prostate cancer. Small strips, 1 mm x 5 mm, cut from the mouse skin samples were loaded into cells in the same way as human samples and slightly stretched to remove the crimp. They remained fully hydrated throughout exposure to the synchrotron beam. The added change that was reported for prostate cancer in 2009 was obtained for all TRAMP mice samples, indicating that this change can be read as High Grade Cancer in human diagnostic tests. These changes were evident for all 3 and 7 week old TRAMP mice samples but not for any of the control samples. This indicates that the changes in the fibre diffraction patterns appear much earlier than in any other available prostate cancer diagnostic test, as none of these can verify the presence of prostate cancer in the TRAMP mice before 10 weeks of age. The fiber diffraction test is therefore the most accurate and earliest test for high grade prostate cancer.

59 BASIC BIOLOGICAL SCIENCES↗

Using Biomolecules to Separate Plutonium - 18393

Relying on the thermodynamics and the reaction kinetics of the metal-ligand bond is the traditional approach to selective separation of metals such as plutonium. An alternative is to use a biologically based separation that leverages multiple factors to sense, bind and transport metals in a series of steps. The protein serum transferrin (Tf) handles the regulation and transport of iron in the blood. Iron and a synergistic anion bind to Tf in one or both of Tf's two lobes (N-lobe and C-lobe). The conformation of Tf changes due to the lobes closing around the metals. The conformational change that occurs when a metal ion and synergistic anion bind to transferrin can trigger additional interactions with the transferrin receptor protein and the subsequent transport of the metal-transferrin complex into cells. Transferrin also is known to bind and transport plutonium into cells but this process is less efficient than iron transport because certain plutonium-transferrin complexes appear to be unable to trigger the same conformational change in transferrin as the iron-transferrin complex. We hypothesize that the synergistic anion is the cause of the different conformational changes that inhibit plutonium-transferrins from binding to the transferrin receptor protein. Using cerium as a non-radioactive surrogate for plutonium(IV), we have been able to synthesize cerium-transferrin complexes with only carbonate as the synergistic anion as a prelude to experiments with plutonium-transferrin complexes that can test our hypothesis. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Monitoring microstructural evolution of alloy 617 with non-linear acoustics for remaining useful life prediction; multiaxial creep-fatigue and creep-ratcheting

The research built upon a prior investigation to develop a unified constitutive model for design-­by-­analysis of the intermediate heat exchanger (IHX) for a very high temperature reactor (VHTR) design of next generation nuclear plants (NGNPs). Model development requires a set of failure data from complex mechanical experiments to characterize the material behavior. Therefore uniaxial and multiaxial creep-­fatigue and creep-­ratcheting tests were conducted on the nickel-­base Alloy 617 at 850 and 950°C. The time dependence of material behavior, and the interaction of time dependent behavior (e.g., creep) with ratcheting, which is an increase in the cyclic mean strain under load-­controlled cycling, are major concerns for NGNP design. This research project aimed at characterizing the microstructure evolution mechanisms activated in Alloy 617 by mechanical loading and dwell times at elevated temperature. The acoustic harmonic generation method was researched for microstructural characterization. It is a nonlinear acoustics method with excellent potential for nondestructive evaluation, and even online continuous monitoring once high temperature sensors become available. It is unique because it has the ability to quantitatively characterize microstructural features well before macroscale defects (e.g., cracks) form. The nonlinear acoustics beta parameter was shown to correlate with microstructural evolution using a systematic approach to handle the complexity of multiaxial creep-­fatigue and creep-­ratcheting deformation. Mechanical testing was conducted to provide a full spectrum of data for: thermal aging, tensile creep, uniaxial fatigue, uniaxial creep-­fatigue, uniaxial creep-ratcheting, multiaxial creep-fatigue, and multiaxial creep-­ratcheting. Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), and Optical Microscopy were conducted to correlate the beta parameter with individual microstructure mechanisms. We researched application of the harmonic generation method to tubular mechanical test specimens and pipes for nondestructive evaluation. Tubular specimens and pipes act as waveguides, thus we applied the acoustic harmonic generation method to guided waves in both plates and shells. Magnetostrictive transducers were used to generate and receive guided wave modes in the shell sample and the received signals were processed to show the sensitivity of higher harmonic generation to microstructure evolution. Modeling was initiated to correlate higher harmonic generation with the microstructure that will lead to development of a life prediction model that is informed by the nonlinear acoustics measurements.

36 MATERIALS SCIENCE↗