Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Los Alamos neutron science center nuclear weapons stewardship and unique national scientific capabilities

This presentation gives an overview of the Los Alamos Neutron Science Center (LANSCE) and its contributions to science and the nuclear weapons program. LANSCE is made of multiple experimental facilities (the Lujan Center, the Weapons Neutron Research facility (WNR), the Ultra-Cold Neutron facility (UCN), the proton Radiography facility (pRad) and the Isotope Production Facility (IPF)) served by the its kilometer long linear accelerator. Several research areas are supported, including materials and bioscience, nuclear science, materials dynamics, irradiation response and medical isotope production. LANSCE is a national user facility that supports researchers worldwide. The LANSCE Risk Mitigation program is currently in progress to update critical accelerator equipment to help extend the lifetime of LANSCE as a key user facility. The Associate Directorate of Business Sciences (ADBS) plays an important role in the continued success of LANSCE. This includes key procurement support, human resource support, technical writing support, and training support. LANSCE is also the foundation of the future signature facility MARIE (Matter-Radiation Interactions in Extremes).

43 PARTICLE ACCELERATORS↗

Status of Dual-readout R&D for a Linear Collider in T1015 Collaboration

The hadronic energy resolution required for an hadronic operating at lepton collider is at the limits or even exceeds that obtained with traditional techniques. Furthermore, it is a well established fact that the presence of an electromagnetic section in front of an hadron calorimeter, as occurs in the layouts of the majority of detectors operating at a collider, would deteriorate the hadronic energy resolution of the device. The novel $ADRIANO$ technology (\textit{A Dual-readout Integrally Active Non-segmented Option}), currently under development at Fermilab, overcomes the above limitations by complementing an integrally active calorimeter with the dual-readout technique. Detailed Monte Carlo studies indicate that the energy resolution is in the $25\%/\sqrt{E}$ - $38\%/\sqrt{E}$ interval with a linear response of the detector up to an energy of 200 GeV. A baseline configuration is chosen with an estimated energy resolution of $\sigma(E)/E\approx30\%/\sqrt{E}$. Several prototypes have been built by \textit{T1015} Collaboration at Fermilab, to explore the effect of modifications of the layout from the baseline configuration. Preliminary results from several test beams at the \textit{Fermilab Test Beam Facility} (FTBF) of $\sim1\lambda_{I}$ prototypes are presented. Future prospects with ultra-heavy glass are, also, summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear analysis of a W band groove-loaded folded waveguide traveling wave tube

A linearized field theory of a groove-loaded folded waveguide traveling wave tube (FWTWT) is developed. The influence of groove dimensions and beam parameters on the linear gain and bandwidth of the device is investigated by numerical calculation. In addition, a comparison of the linear gain properties between the groove-loaded FWTWT and the conventional one is also carried out. It is indicated from the investigation that by the groove loading, the electric field that acts on the electron beam is enhanced, the electron beam gives more energy to wave, and the linear gain is raised.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

Characterization and calibration of 8-channel E-band heterodyne radiometer system for SST-1 tokamak

An 8-channel E-band heterodyne radiometer system (74–86 GHz) is designed, characterized, and calibrated to measure the radial electron temperature profile by measuring Electron Cyclotron Emission spectrum at SST-1 Tokamak. The developed radiometer has a noise equivalent temperature of 1 eV and sensitivity of 5 × 10{sup 9} V/W. In order to precisely measure the absolute value of electron temperature, a calibration measurement of the radiometer system is performed using hot-cold Dicke switch method, which confirms the system linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum effects on compressional Alfven waves in compensated semiconductors

Amplitude modulation of a compressional Alfven wave in compensated electron-hole semiconductor plasmas is considered in the quantum magnetohydrodynamic regime in this paper. The important ingredients of this study are the inclusion of the particle degeneracy pressure, exchange-correlation potential, and the quantum diffraction effects via the Bohm potential in the momentum balance equations of the charge carriers. A modified nonlinear Schrödinger equation is derived for the evolution of the slowly varying amplitude of the compressional Alfven wave by employing the standard reductive perturbation technique. Typical values of the parameters for GaAs, GaSb, and GaN semiconductors are considered in analyzing the linear and nonlinear dispersions of the compressional Alfven wave. Detailed analysis of the modulation instability in the long-wavelength regime is presented. For typical parameter ranges of the semiconductor plasmas and at the long-wavelength regime, it is found that the wave is modulationally unstable above a certain critical wavenumber. Effects of the exchange-correlation potential and the Bohm potential in the wave dynamics are also studied. It is found that the effect of the Bohm potential may be neglected in comparison with the effect of the exchange-correlation potential in the linear and nonlinear dispersions of the compressional Alfven wave.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear shearing modes approach to the diocotron instability of a planar electron strip

The nonlinear evolution of the diocotron instability of a planar electron strip is investigated analytically by means of the nonlinear shearing mode for the solution of the initial and boundary value problems. The method is based on the sheared spatial coordinates which account for the motion of electron flow in the electrostatic field of the unstable diocotron modes in addition to the unperturbed sheared motion of the electron flow on the transformed shear coordinates. The time evolutions are studied by the solution of the initial and boundary value problems. The obtained solutions for the perturbed electrostatic potential include two nonlinear effects—the effect of the distortion of the boundaries of the planar electron strip and the effect of the coupling of the sheared nonmodal diocotron modes. It was proved by a two-dimensional particle-in-cell simulation that the developed theory is valid as long as the distortion of the boundaries of the basic shear flow does not change the frequency and growth rate of the linear diocotron instability in the transformed coordinates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A generalized Boltzmann kinetic theory for strongly magnetized plasmas with application to friction

Coulomb collisions in plasmas are typically modeled using the Boltzmann collision operator, or its variants, which apply to weakly magnetized plasmas in which the typical gyroradius of particles significantly exceeds the Debye length. Conversely, O’Neil has developed a kinetic theory to treat plasmas that are so strongly magnetized that the typical gyroradius of particles is much smaller than the distance of the closest approach in a binary collision. Here, we develop a generalized collision operator that applies across the full range of magnetization strength. Since there is no closed-form solution for the scattering cross section when plasma is strongly magnetized, the input to the collision operator is obtained by numerically calculating particle trajectories. To demonstrate novel physics associated with strong magnetization, it is used to compute the friction force on a massive test charge. In addition to the traditional stopping power component, this is found to exhibit a transverse component that is perpendicular to both the velocity and Lorentz force vectors in the strongly magnetized regime, as was predicted recently using linear response theory. As a result, good agreement is found between the collision theory and linear response theory in the regime in which both apply, but the new collision theory also applies to stronger magnetization strength regimes than the linear response theory is expected to apply in.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging

Purpose: For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide ρ{sub e} range. The purpose of the present study was to reveal the relation between the ΔHU image for ρ{sub e} calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. Methods: The author determined the weighting factor, α{sub 0}, of the ΔHU–ρ{sub e} conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρ{sub e} values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the XCOM photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80–140 and 100–140 kV/Sn. Results: The determined α{sub 0} values were 0.455 for 80–140 kV/Sn and 0.743 for 100–140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. Conclusions: The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-threshold parametric excitation of the upper hybrid wave in experiments on electron-cyclotron resonance heating by an ordinary wave

The possibility of the low-threshold decay of an ordinary wave into an upper hybrid wave localized in a plasma column (or in an axisymmetric plasma filament) and a low-frequency wave is analyzed. It is shown that the threshold for such a decay, accompanied by the excitation of an ion-acoustic wave, can easily be overcome for plasma parameters typical of model experiments on the Granit linear plasma facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pseudo-transient Continuation Based Variable Relaxation Solve in Nonlinear Magnetohydrodynamic Simulations

Efficient and robust Variable Relaxation Solver, based on pseudo-transient continuation, is developed to solve nonlinear anisotropic thermal conduction arising from fusion plasma simulations. By adding first and/or second order artificial time derivatives to the system, this type of method advances the resulting time-dependent nonlinear PDEs to steady state, which is the solution to be sought. In this process, only the stiffness matrix itself is involved so that the numerical complexity and errors can be greatly reduced. In fact, this work is an extension of integrating efficient linear elliptic solvers for fusion simulation on Cray XIE. Two schemes are derived in this work, first and second order Variable Relaxations. Four factors are observed to be critical for efficiency and preservation of solution's symmetric structure arising from periodic boundary condition: refining meshes in different coordinate directions, initializing nonlinear process, varying time steps in both temporal and spatial directions, and accurately generating nonlinear stiffness matrix. First finer mesh scale should be taken in strong transport direction; Next the system is carefully initialized by the solution with linear conductivity; Third, time step and relaxation factor are vertex-based varied and optimized at each time step; Finally, the nonlinear stiffness matrix is updated by just scaling corresponding linear one with the vector generated from nonlinear thermal conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for Complex Molecular Architectures for Solvent-Extracted Lignins

Lignin, an abundant, naturally occurring biopolymer, is often considered 'waste' and used as a simple fuel source in the paper-making process. However, lignin has emerged as a promising renewable resource for engineering materials, such as carbon fibers. Unfortunately, the molecular architecture of lignin (in vivo and extracted) is still elusive, with numerous conflicting reports in the literature, and knowledge of this structure is extremely important, not only for materials technologies, but also for production of biofuels such as cellulosic ethanol due to biomass recalcitrance. As such, the molecular structures of solvent-extracted (sulfur-free) lignins, which have been modified using various acyl chlorides, have been probed using small-angle X-ray (SAXS) and neutron (SANS) scattering in tetrahydrofuran (THF) solution along with hydrodynamic characterization using dilute solution viscometry and gel permeation chromatography (GPC) in THF. Mass spectrometry shows an absolute molecular weight {approx}18-30 kDa ({approx}80-140 monomers), while GPC shows a relative molecular weight {approx}3 kDa. A linear styrene oligomer (2.5 kDa) was also analyzed in THF using SANS. Results clearly show that lignin molecular architectures are somewhat rigid and complex, ranging from nanogels to hyperbranched macromolecules, not linear oligomers or physical assemblies of oligomers, which is consistent with previously proposed delignification (extraction) mechanisms. Future characterization using the methods discussed here can be used to guide extraction processes as well as genetic engineering technologies to convert lignin into value added materials with the potential for high positive impact on global sustainability.

09 BIOMASS FUELS↗

WE-DE-BRA-08: A Linear Accelerator Target Allowing Rapid Switching Between Treatment and High-Contrast Imaging Modes

Purpose: During radiotherapy treatment, lung tumors can display substantial respiratory motion. This motion usually necessitates enlarged treatment margins to provide full tumour coverage. Unfortunately, these margins limit the dose that can be prescribed for tumour control and cause complications to normal tissue. Options for real-time methods of direct detection of tumour position, and particularly those that obviate the need for inserted fiducial markers, are limited. We propose a method of tumor tracking without implanted fiducial markers using a novel fast switching-target that toggles between a FFF copper/tungsten therapy mode and a FFF low-Z target mode for imaging. In this work we demonstrate proof-of-concept of this new technology. Methods: The prototype includes two targets: i) a FFF copper/tungsten target equivalent to that in the Varian 2100 EX 6 MV, and ii) a low-Z (carbon) target with a thickness of 110% of continuous slowing down approximation range (CSDA) at 7 MeV. The two targets can be exchanged with a custom made linear slide and motor-driven actuator. The usefulness of the switching-target concept is demonstrated through experimental BEV Planar images acquired with continual treatment and imaging at a user-defined period. Results: The prototype switching-target demonstrates that two recent advances in linac technology (FFF target for therapy and low-Z target) can be combined with synergy. The switching-target approach offers the capacity for rapid switching between treatment and high-contrast imaging modes, allowing intrafractional tracking, as demonstrated in this work with dynamic breathing phantom. By using a single beam-line, the design is streamlined and may obviate the need for an auxiliary imaging system (e.g., kV OBI.) Conclusion: This switching-target approach is a feasible combination of two current advances in linac technology (FFF target for therapy and a FFF low-Z target) allowing new options in on-line IGRT.

60 APPLIED LIFE SCIENCES↗

Beam properties and stability of a flattening-filter free 7 MV beam--An overview

Purpose: Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). Methods: Dosimetric properties of the 7XU beam were measured in May and September 2011. We present depth dose curves and beam profiles, output factors, and MLC transmission and assess the stability of the measurements. The 7XU beam was commissioned in the Pinnacle Superscript-Three treatment planning system (TPS), and modeling results including the spectrum are presented. Results: The percent depth dose curve of the 7XU beam is similar to the flat 6X beam line, with a slightly smaller surface dose. The beam profiles show the characteristic shape of flattening-filter free beams, with deviations between measurements of generally less than 1%. The output factors of the 7XU beam decrease more slowly than for the 6X beam. The MLC transmission is comparable but slightly less for the 7XU beam. The 7XU beam can be adequately modeled by the Pinnacle Superscript-Three TPS, with successful dosimetric verification. The spectrum of the 7XU beam has lower photon fluence up to approximately 2.5 MeV and higher fluence beyond, with a slightly higher mean energy. Conclusions: The 7XU beam has been commissioned for clinical use after successful modeling, stability checks, and dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary results from a test beam of ADRIANO prototype

The physics program at future colliders demands an energy resolution of the calorimetric component of detectors at the limits of traditional techniques. The ADRIANO technology (A Dual-readout Integrally Active Non-segmented Option) is under development with an expected excellent performance. Results from detailed Monte Carlo studies on performance with respect to energy resolution, linear response and transverse containment and a preliminary optimization of the layout are presented. A baseline configuration is chosen with an estimated energy resolution of σ(E)/E ≈ 30%/√E, to support an extensive R&D program recently started by T1015 Collaboration at Fermilab. Preliminary results from a test beam at the Fermilab Test Beam Facility (FTBF) of a ~ 1λ(I) prototype are presented, along with simulation studies. Future prospects with ultra-heavy glass are, also, summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retention and surface morphology evaluation of fine-grain dispersion-strengthened tungsten for plasma-facing component applications

This study exposed novel fine-grain dispersion-strengthened tungsten (W) to high fluence, low energy deuterium (D) and helium (He) plasmas to evaluate how material microstructure and composition affect hydrogen retention and surface morphology. Tested materials included fine-grain dispersion-strengthened tungsten (DSW) with 3 wt% zirconium carbide (ZrC) dispersoids, fine-grain dense W without any dispersoids (FGW), and coarse-grained polycrystalline ‘ITER-grade’ W. Samples were exposed to D 2 + and He + plasmas at fusion-relevant fluences (∼10 25 m -2 ) and ion energies (75 eV) over a range of temperatures (200 °C, 300 °C, 450 °C for D, 850 °C for He). Helium ion microscopy was performed on the exposed samples to evaluate surface morphology changes and material integrity. After D plasma exposure, the ZrC dispersoids showed near-surface degradation at exposure temperatures above 300 °C, but no detrimental morphology changes were observed for the adjacent W grains. After He plasma-exposure, nano-structured fuzz formation was observed in the tungsten matrix of all samples. The ZrC dispersoids maintained their integrity despite the surrounding fuzz growth, with clear delineation between the W fuzz and dispersoid regions. Thermal desorption spectroscopy showed that ZrC DSW consistently retained more D than the FGW by about a factor of 2 across all temperatures. At 200 °C and 300 °C, the ITER-W displayed lower D retention than both the DSW and FGW, however at 450 °C ITER-W showed the highest retention, about 50% more than DSW. He retention was comparable across all samples, with the highest retention observed in the fine-grain W, only 26% higher than in ITER-W. These insights on retention behavior will inform further optimization of these novel fine-grained tungsten materials with and without dispersoid additives.

Dispersion-strengthened tungsten↗

Integrated structured light architectures

Abstract The structural versatility of light underpins an outstanding collection of optical phenomena where both geometrical and topological states of light can dictate how matter will respond or display. Light possesses multiple degrees of freedom such as amplitude, and linear, spin angular, and orbital angular momenta, but the ability to adaptively engineer the spatio-temporal distribution of all these characteristics is primarily curtailed by technologies used to impose any desired structure to light. We demonstrate a laser architecture based on coherent beam combination offering integrated spatio-temporal field control and programmability, thereby presenting unique opportunities for generating light by design to exploit its topology.

42 ENGINEERING↗

Linear accelerator x-ray sources with high duty cycle

X-ray cargo inspection systems typically use a several-MV pulsed linear accelerator (linac) to produce a bremsstrahlung spectrum of x rays by bombarding a target with electrons. The x rays traverse the cargo and are detected by a detector array. Spectroscopy of the detected x rays is very desirable: if one can determine the spectrum of the transmitted x rays, one can determine the Z of the material they traversed. Even in relatively low-dose modes of operation, thousands of x rays arrive at each detector element during each pulse, unless the x rays are heavily absorbed or scattered by the cargo. For portal or fixed-site systems, dose rates, and therefore x-ray count rates, are even higher. Because of the high x-ray count rate, spectroscopy is impractical in conventional cargo inspection systems, except in certain special cases. For a mobile system, typical pulse durations are a few microseconds, and the number of pulses is on the order of 100 per second, leading to a duty factor of about 0.04%. Clearly, a linear accelerator x-ray source with much higher duty factor would be useful, since then the same number of x rays could be spread out over time, reducing the x-ray count rate. In this paper, we explore the possibility of designing a linear accelerator system, using more or less Conventional Off the Shelf (COTS) components, capable of duty cycles of 1% or greater. A survey was conducted of available linac RF source options and, given the possibilities, calculations were performed for suitable beam centerline designs. Keeping in mind that the size and cost of the accelerator system should be practical for use in a mobile cargo inspection system, only a few options are shown to be reasonably feasible, both requiring the use of klystrons instead of the magnetrons used in conventional systems. An S-Band design appears clearly possible, and there is also a promising X-Band design.

43 PARTICLE ACCELERATORS↗