Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

A sample holder with integrated laser optics for an ELMITEC photoemission electron microscope

We present a new sample holder compatible with ELMITEC Photoemission Electron Microscopes (PEEMs) containing an optical lens and a mirror. With the integrated optical elements, a laser beam is focused from the back side of the sample at normal incidence, yielding a minimum spot size of about 1 μm. This opens up new possibilities for local laser excitations in PEEM experiments such as imaging all-optical magnetization switching at a small length scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surges as tracers of magnetic lines

During the maximum activity year 1980, chromospheric mass ejections were observed with the Multichannel Subtractive Double Pass Spectrograph operating at Meudon (MSDP), while the UV and X-ray emissions were observed respectively with the UV Spectrograph (UVSP) and HXIS instruments on the SMM satellite. These ejections are not related directly to flares but are located in active regions near sunspots. As the magnetic field is frozen in the matter, the study of the velocity field leads to the geometry of the magnetic structures and the temporal evolution of the magnetic-field lines. Ejections of matter recur often with a period of 10 to 20 minutes. In C IV, the bright loops coincide with the H-alpha surge but are more extended. Associated with the events are either X-ray emission or type-III bursts.

Schmieder, B.↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

Characterization of Silicon PhotoMultipliers at LNS-INFN

The Silicon PhotoMultipliers (SiPMs) are a new generation of photodetectors having high sensitivity, excellent time resolution, compactness, low power supply, and insensitivity to magnetic fields. Their properties make them a valid alternative to the PMTs in several fields, such as particle physics, medicine, and space technology. At Laboratori Nazionali del Sud (LNS), a complete characterization of samples developed by different companies (Hamamatsu, STM, SensL) has been performed in order to measure the most significant properties, consisting of the dark noise, cross talk probability, photon detection efficiency, and charge and timing resolutions. Measurements have also been performed coupling the SiPMs with scintillating fibres and small size LYSO scintillators in order to investigate possible applications in Positron Emission Tomography (PET) diagnostics and in the monitoring of nuclear waste sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submillimeter heterodyne spectroscopy and remote sensing of the upper atmosphere

Submillimeter-wavelength heterodyne spectroscopy by microwave limb sounding (MLS) from orbiting satellite is a measurement technique for studying Earth's stratosphere, mesosphere and lowerr thermosphere on a global scale. Development and deployment of such tools are timely, as stratospheric ozone shileds life from solar ultraviolet radiation but is depleted by pollution from industrial activities. MLS experiments on NASA's Upper Atmosphere Research Satellite (UARS) and Earth Observing System (EOS) are now being developed and implementend for global monitoring. Atmospheric thermal-emission spectra at millimeter and submillimeter wave-lengths are measured as the instrument field of view (FOV) is scanned through the limb from above. Atmospheric profiles of molecular abundances, temperature, pressure, wind and magnetic field can be determined from the measured emission spectra. Intensity of the emission can provide abundance and temperature. Measured linewidths, and emission from temperature-insensitive O2 lines, can provide pressure. Differentitaion of measured pressure with repsect ot measured height differential (obtaiend from the instrument FOV scan encoder) can also provide temperature through atmospheric hydrostatic equilibrium (which relates temperature to pressure and height differential). Doppler shifts of spectral lines can provide wind, and Zeeman splitting of the magnetic-dipole lines of O2 can provide magnetic field.

Waters, J. W.↗

Interstellar Dust Grain Alignment

Dust induced polarization is an efficient probe of the interstellar magnetic field. The combination of short wavelength dichroic extinction polarimetry with far-infrared/sub-mm wave emission observations, using modern instruments, allow us to measure the polarization from diffuse gas to star forming cores. With our improved understanding of the physics of grain alignment we can now better interpret the observations and evaluate the importance of the magnetic field. Radiative Alignment Torque (RAT) grain-alignment has been observationally confirmed, but some aspects and details are still being clarified. The quantitative theoretical frame work provided by RAT theory, also allows long standing questions about the interstellar environment and dust characteristics to be addressed anew - including dust composition and structure. I will review the basics of RAT alignment and its observational support and discuss some of the open questions of dust induced polarization.

Andersson, B.-G.↗

The beamline ID32 at the ESRF for soft X-ray high energy resolution resonant inelastic X-ray scattering and polarisation dependent X-ray absorption spectroscopy

Here, the ID32 Soft X-ray Beamline line is an ESRF upgrade beamline for X-ray absorption (XAS) and Resonant Inelastic X-ray Scattering (RIXS) spectroscopic studies. It was opened to Users in October 2014 and provides polarised soft X-rays in the 400–1600 eV energy range. It has two branches: One branch has been designed for X-ray magnetic dichroism experiments, both linear (XMLD) and circular (XMCD), with high sensitivity, reproducibility, flexibility, user friendliness and the capability for fast energy scanning. The X-ray beam is available in two experimental areas, one with a dedicated superconducting high field magnet and a sample preparation facility, the second area being open for User instruments. The other branch is dedicated to very high energy resolution Resonant Inelastic X-ray Scattering experiments with a combined resolving power up to 30 000 around 930 eV. A scattering arm which is continuously variable under UHV vacuum over 100 degrees and a four-circle sample goniometer allows accurate positioning of the sample to enable 3D mapping of q space. Combined with the possibility of polarisation analysis of the outgoing photons the beamline provides a state-of-the-art soft X-ray RIXS facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unified Picture for Magnetic Correlations in Iron-Based Superconductors

The varying metallic antiferromagnetic correlations observed in iron-based superconductors are unified in a model consisting of both itinerant electrons and localized spins. The decisive factor is found to be the sensitive competition between the superexchange antiferromagnetism and the orbital-degenerate double-exchange ferromagnetism. Our results reveal the crucial role of Hund's rule coupling for the strongly correlated nature of the system and suggest that the iron-based superconductors are closer kin to manganites than cuprates in terms of their diverse magnetism and incoherent normal-state electron transport. This unified picture would be instrumental for exploring other exotic properties and the mechanism of superconductivity in this new class of superconductors.

36 MATERIALS SCIENCE↗

Surveyor Project Final Report: Part 1 - Project Description and Performance, Volume 1

The Surveyor Project planned and conducted seven unmanned lunar missions for which spacecraft were launched between May 1966 and January 1968. Each of the spacecraft was successfully launched with the then newly developed Atlas/Centaur vehicle which utilized for the first time a high-specific-impulse, liquid hydrogen/liquid oxygen fueled stage. Five of the spacecraft successfully soft-landed and returned a great quantity of engineering and scientific data on extensive postlanding operations, accomplishing all mission and project objectives. Four of the spacecraft soft-landed at selected mare sites to provide data which were required to support the Apollo Program. The final spacecraft was then successfully used for scientific investigation of a contrasting site in the rugged lunar highlands. Surveyor was a fully attitude-stabilized spacecraft designed to receive and execute a wide variety of earth commands, as well as to perform certain automatic functions including the critical terminal-descent and soft-landing sequences. Significant new and advanced subsystems that were developed and/or used in combination to enable Surveyor to execute the complex terminal phase of flight were: (1) a solid-propellant main retro motor, (2) throttlable liquid-propellant vernier engines (also used for midcourse velocity correction), (3) highly sensitive velocity- and altitude-sensing radars, and (4) an automatic closed-loop guidance and control system. The first Surveyor spacecraft carried a survey television camera which, together with other engineering instrumentation, obtained in-flight and postlanding data. The complement of instruments carried on later missions included various combinations of the following additional devices: (1) a soil mechanics/surface sampler instrument for picking, digging, and handling lunar surface material; (2) an alpha scattering instrument for performing a chemical analysis of the lunar surface material; and (3) magnets attached to the spacecraft for determining magnetic properties of the soil.

Jet Propulsion Laboratory↗

Surveyor Project Final Report: Part 1 - Project Description and Performance, Volume 2

The Surveyor Project planned and conducted seven unmanned lunar missions for which spacecraft were launched between May 1966 and January 1968. Each of the spacecraft was successfully launched with the then newly developed Atlas/Centaur vehicle which utilized for the first time a high-specific-impulse, liquid hydrogen/liquid oxygen fueled stage. Five of the spacecraft successfully soft-landed and returned a great quantity of engineering and scientific data on extensive postlanding operations, accomplishing all mission and project objectives. Four of the spacecraft soft-landed at selected mare sites to provide data which were required to support the Apollo Program. The final spacecraft was then successfully used for scientific investigation of a contrasting site in the rugged lunar highlands. Surveyor was a fully attitude-stabilized spacecraft designed to receive and execute a wide variety of earth commands, as well as to perform certain automatic functions including the critical terminal-descent and soft-landing sequences. Significant new and advanced subsystems that were developed and/or used in combination to enable Surveyor to execute the complex terminal phase of flight were: (1) a solid-propellant main retro motor, (2) throttlable liquid-propellant vernier engines (also used for midcourse velocity correction), (3) highly sensitive velocity- and altitude-sensing radars, and (4) an automatic closed-loop guidance and control system. The first Surveyor spacecraft carried a survey television camera which, together with other engineering instrumentation, obtained in-flight and postlanding data. The complement of instruments carried on later missions included various combinations of the following additional devices: (1) a soil mechanics/surface sampler instrument for picking, digging, and handling lunar surface material; (2) an alpha scattering instrument for performing a chemical analysis of the lunar surface material; and (3) magnets attached to the spacecraft for determining magnetic properties of the soil.

Jet Propulsion Laboratory↗

A 0.4 to 10 GHz airborne electromagnetic environment survey of USA urban areas

An airborne electromagnetic-environment survey of some U.S. metropolitan areas measured terrestrial emissions within the broad frequency spectrum from 0.4 to 10 GHz. A Cessna 402 commercial aircraft was fitted with both nadir-viewing and horizon-viewing antennas and instrumentation, including a spectrum analyzer, a 35 mm continuous film camera, and a magnetic tape recorder. Most of the flights were made at a nominal altitude of 10,000 feet, and Washington, D. C., Baltimore, Philadelphia, New York, and Chicago were surveyed. The 450 to 470 MHz land-mobile UHF band is especially crowded, and the 400 to 406 MHz space bands are less active. This paper discusses test measurements obtained up to 10 GHz. Sample spectrum analyzer photograhs were selected from a total of 5,750 frames representing 38 hours of data.

Taylor, R. E.↗

On tenuous plasmas, fireballs, and boundary layers in the earth's magnetotail

The plasma instrumentation (the Lepedea) and the magnetometer aboard IMP 8 performed correlative measurements of magnetic fields and plasmas within the geomagnetic tail at geocentric radial distances of about 23-46 R-E during March-October 1974. The hot tenuous plasmas within the plasma sheet were found to be in a state of almost continuous flow and were threaded with northward, or closed geomagnetic lines. The satellite encountered a region of acceleration in the magnetotail, the 'fireball' which exhibits strong jetting of plasmas in excess of 1000 km/s, proton temperatures of about 10 to the 7th K, disordered magnetic fields, southward magnetic fields during tailward jetting of plasmas, and northward magnetic fields for fast plasma flows toward earth. In addition, the magnetosheath plasmas within the boundary layers which are contiguous to the plasma sheet display evidence of plasma heating, great changes in bulk flow velocities, and acceleration of energetic electrons with an energy of greater than 45 keV.

Frank, L. A.↗

Cardiovascular imaging and image processing: Theory and practice - 1975; Proceedings of the Conference, Stanford University, Stanford, Calif., July 10-12, 1975

The present collection of papers outlines advances in ultrasonography, scintigraphy, and commercialization of medical technology as applied to cardiovascular diagnosis in research and clinical practice. Particular attention is given to instrumentation, image processing and display. As necessary concomitants to mathematical analysis, recently improved magnetic recording methods using tape or disks and high-speed computers of large capacity are coming into use. Major topics include Doppler ultrasonic techniques, high-speed cineradiography, three-dimensional imaging of the myocardium with isotopes, sector-scanning echocardiography, and commercialization of the echocardioscope. Individual items are announced in this issue.

Harrison, D. C.↗

Revised upper limit on the internal magnetic moment of Venus

Over four Venus years of low altitude nightside PVO magnetometer observations are used to establish a new upper limit for the magnetic moment of Venus. Improvements over previous studies include data coverage and new instrument calibration information. The upper limit on an internal dipole moment is determined to be 8.4 x 10 to the 10th T cu m.

Phillips, J. L.↗