Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods: data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Measurement of 𝑑 2⁢ 𝜎/𝑑⁢|$\vec{q}$|⁢𝑑⁢𝐸 avail in charged current 𝜈 𝜇 -nucleus interactions at ⟨𝐸 𝜈 ⟩=1.86 GeV using the NOvA Near Detector

Double- and single-differential cross sections for inclusive charged-current 𝜈 𝜇 -nucleus scattering are reported for the kinematic domain 0 to 2 GeV/𝑐 in three-momentum transfer and 0 to 2 GeV in available energy, at a mean 𝜈 𝜇 energy of 1.86 GeV. The measurements are based on an estimated 995,760 𝜈 𝜇 charged-current (CC) interactions in the scintillator medium of the NOvA Near Detector. The subdomain populated by 2-particle-2-hole (2p2h) reactions is identified by the cross section excess relative to predictions for 𝜈 𝜇 -nucleus scattering that are constrained by a data control sample. Models for 2-particle-2-hole processes are rated by 𝜒 2 comparisons of the predicted-versus-measured 𝜈 𝜇 CC inclusive cross section over the full phase space and in the restricted subdomain. Shortfalls are observed in neutrino generator predictions obtained using the theory-based València and SuSAv2 2p2h models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment

We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 ± 0.19 and 1.86 ± 0.17 near muon and pion track endpoints, respectively. The 3.6⁢𝜎 statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 ± 0.08) and pion (2.34 ± 0.09) nuclear captures. We attribute this difference to geant4’s inaccurate simulation of the nuclear capture process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and chemical orders in N i 64.5 Z r 35.5 metallic glass by molecular dynamics simulation

The atomic structure of Ni 64.5 Zr 35.5 metallic glass has been investigated by molecular dynamics (MD) simulations. The calculated structure factors from the MD glassy sample at room temperature agree well with the X-ray diffraction (XRD) and neutron diffraction (ND) experimental data. Using the pairwise cluster alignment and clique analysis methods, we show that there are three types dominant short-range order (SRO) motifs around Ni atoms in the glass sample of Ni 64.5 Zr 35.5 , i.e., Mixed- Icosahedron(ICO)-Cube, Twined-Cube and icosahedron-like clusters. Furthermore, chemical order and medium-range order (MRO) analysis show that the Mixed-ICOCube and Twined-Cube clusters exhibit the characteristics of the crystalline B2 phase. In conclusion, our simulation results suggest that the weak glass-forming ability (GFA) of Ni 64.5 Zr 35.5 can be attributed to the competition between the glass forming ICO SRO and the crystalline Mixed-ICO-Cube and Twined-Cube motifs.

36 MATERIALS SCIENCE↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing crystalline defects in single nanoparticles from angular correlations of single-shot diffracted X-rays

Characterizing and controlling the uniformity of nanoparticles is crucial for their application in science and technology because crystalline defects in the nanoparticles strongly affect their unique properties. Recently, ultra-short and ultra-bright X-ray pulses provided by X-ray free-electron lasers (XFELs) opened up the possibility of structure determination of nanometre-scale matter with Å spatial resolution. However, it is often difficult to reconstruct the 3D structural information from single-shot X-ray diffraction patterns owing to the random orientation of the particles. This report proposes an analysis approach for characterizing defects in nanoparticles using wide-angle X-ray scattering (WAXS) data from free-flying single nanoparticles. The analysis method is based on the concept of correlated X-ray scattering, in which correlations of scattered X-ray are used to recover detailed structural information. WAXS experiments of xenon nanoparticles, or clusters, were conducted at an XFEL facility in Japan by using the SPring-8 Ångstrom compact free-electron laser (SACLA). Bragg spots in the recorded single-shot X-ray diffraction patterns showed clear angular correlations, which offered significant structural information on the nanoparticles. The experimental angular correlations were reproduced by numerical simulation in which kinematical theory of diffraction was combined with geometric calculations. We also explain the diffuse scattering intensity as being due to the stacking faults in the xenon clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r{sup 2} = 0.772, mean r{sup 2} = 0.562) and for organ volume versus height (max r{sup 2} = 0.781, mean r{sup 2} = 0.601). Conclusions: Adult patients exhibited small variations in organ volume and location with respect to height and weight, but no meaningful correlation existed between these parameters and age or BMI. Once adulthood is reached, organ morphology and positioning seem to remain static. However, clear trends are evident between pediatric organ locations versus age, height, and weight. Such information can be incorporated into a matching methodology that may provide the highest probability of representing the anatomy of a patient undergoing a clinical exam to prospectively estimate the radiation dose.

60 APPLIED LIFE SCIENCES↗

LinkShop v.1.0.0

LinkShop is a software tool for applying the method of Linkography to the analysis time-sequence data. LinkShop provides command line, web, and application programming interfaces (API) for input and processing of time-sequence data, abstraction models, and ontologies. The software creates graph representations of the abstraction model, ontology, and derived linkograph. Finally, the tool allows the user to perform statistical measurements of the linkograph and refine the ontology through direct manipulation of the linkograph.

Jarocki, JohnCharles↗

Cadmus v1.0

This software package is for distributed computation of persistent (co)homology. It is primarily intended for Topological Data Analysis (TDA) audience and scientists who use TDA methods and apply them to datasets that are too big to handle on a single machine. There are very few codes available for this; Cadmus outperforms DIPHA, if the user is interested in cohomology. The accompanying paper explaining the algorithm was accepted to ALENEX 26.

Nigmetov, Arnur [Lawrence Berkeley National Labora↗

Pivotal trial characteristics and types of endpoints used to support Food and Drug Administration rare disease drug approvals between 2013 and 2022

Background/aims Rare disease drug development faces unique challenges, such as genotypic and phenotypic heterogeneity within small patient populations and a lack of established outcome measures for conditions without previously successful drug development programs. These challenges complicate the process of selecting the appropriate trial endpoints and conducting clinical trials in rare diseases. In this descriptive study, we examined novel drug approvals for non-oncologic rare diseases by the U.S. Food and Drug Administration’s Center for Drug Evaluation and Research over the past decade and characterized key regulatory and trial design elements with a focus on the primary efficacy endpoint utilized as the basis of approval. Methods Using the Food and Drug Administration’s Data Analysis Search Host database, we identified novel new drug applications and biologics license applications with orphan drug designation that were approved between 2013 and 2022 for non-oncologic indications. From Food and Drug Administration review documents and other external databases, we examined characteristics of pivotal trials for the included drugs, such as therapeutic area, trial design, and type of primary efficacy endpoints. Differences in trial design elements associated with primary efficacy endpoint type were assessed such as randomization and blinding. Then, we summarized the primary efficacy endpoint types utilized in pivotal trials by therapeutic area, approval pathway, and whether the disease etiology is well defined. Results One hundred and seven drugs that met our inclusion criteria were approved between 2013 and 2022. Assessment of the 107 drug development programs identified 150 pivotal trials that were subsequently analyzed. The pivotal trials were mostly randomized (80%) and blinded (69.3%). Biomarkers (41.1%) and clinical outcomes (42.1%) were commonly utilized as primary efficacy endpoints. Analysis of the use of clinical trial design elements across trials that utilized biomarkers, clinical outcomes, or composite endpoints did not reveal statistically significant differences. The choice of primary efficacy endpoint varied by the drug’s therapeutic area, approval pathway, and whether the indicated disease etiology was well defined. For example, biomarkers were commonly selected as primary efficacy endpoints in hematology drug approvals (70.6%), whereas clinical outcomes were commonly selected in neurology drug approvals (69.6%). Further, if the disease etiology was well defined, biomarkers were more commonly used as primary efficacy endpoints in pivotal trials (44.7%) than if the disease etiology was not well defined (27.3%). Discussion In the past 10 years, numerous novel drugs have been approved to treat non-oncologic rare diseases in various therapeutic areas. To demonstrate their efficacy for regulatory approval, biomarkers and clinical outcomes were commonly utilized as primary efficacy endpoints. Biomarkers were not only frequently used as surrogate efficacy endpoints in accelerated approvals, but also in traditionally approved rare disease drugs. The choice of primary efficacy endpoints varied by therapeutic area, approval pathway, and understanding of disease etiology.

Hong, Kyungwan [Rare Diseases Team, Office of New ↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

Experimental Studies of Elementary Particle Interactions at High Energies

This is the final report of a program of research on "Experimental Studies of Elementary Particle Interactions at High Energies'' of the High Energy Physics (HEP) group of The Rockefeller University. The research was carried out using the Collider Detector at Fermilab (CDF) and the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) at CERN. Three faculty members, two research associates, and two postdoctoral associates participated in this project. At CDF, we studied proton-antiproton collisions at an energy of 1.96 TeV. We focused on diffractive interactions, in which the colliding antiproton loses a small fraction of its momentum, typically less than 1%, while the proton is excited into a high mass state retaining its quantum numbers. The study of such collisions provides insight into the nature of the diffractive exchange, conventionally referred to as Pomeron exchange. In studies of W and Z production, we found results that point to a QCD-based interpretation of the diffractive exchange, as predicted in a data-driven phenomenology developed within the Rockefeller HEP group. At CMS, we worked on diffraction, supersymmetry (SUSY), dark matter, large extra dimensions, and statistical applications to data analysis projects. In diffraction, we extended our CDF studies to higher energies working on two fronts: measurement of the single/double diffraction and of the rapidity gap cross sections at 7 TeV, and development of a simulation of diffractive processes along the lines of our successful model used at CDF. Working with the PYTHIA8 Monte Carlo simulation authors, we implemented our model as a PYTHIA8-MBR option in PYTHIA8 and used it in our data analysis. Preliminary results indicate good agreement. We searched for SUSY by measuring parameters in the Constrained Minimal Supersymmetric extension of the Standard Model (CMSSM) and found results which, combined with other experimental constraints and theoretical considerations, indicate that the CMSSM is not a viable model. Expressing our results in terms of simple topologies, we exclude squark masses below 0.75 TeV and gluino masses below 1.1 TeV. Astrophysical measurements suggest that about 80% of the matter density of the Universe is non-luminous. One of the theories on dark matter attributes it to Weakly Interacting Massive Particles (WIMPs). We searched for WIMPs in 7 TeV and 8 TeV collisions at CMS and set limits on WIMP production rates, which are competitive and complementary to those of direct detection experiments. Searching for monojets (events with only one jet), which in a popular model could be produced by a jet paired by a gravitino that escapes into extra dimensions, we significantly improved the previously set limit. Our results have been used to set limits on Higgs decay to invisible particles and on production of top squarks in compressed SUSY scenarios. Statistics. We computed Bayesian reference priors for several types of measurement and used them in the analysis of CMS data; investigated the applicability of bootstrap methods to HEP measurements; studied several issues associated with simple-versus-simple hypothesis testing and applied the resulting methods to the measurement of some properties of the top quark and Higgs boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Update on Improvements to NiCE Support for PROTEUS

The Department of Energy Office of Nuclear Energy's Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has supported the development of the NEAMS Integrated Computational Environment (NiCE), a modeling and simulation workflow environment that provides services and plugins to facilitate tasks such as code execution, model input construction, visualization, and data analysis. This report details the development of workflows for the reactor core neutronics application, PROTEUS. This advanced neutronics application (primarily developed at Argonne National Laboratory) aims to improve nuclear reactor design and analysis by providing an extensible and massively parallel, finite-element solver for current and advanced reactor fuel neutronics modeling. The integration of PROTEUS-specific tools into NiCE is intended to make the advanced capabilities that PROTEUS provides more accessible to the nuclear energy research and development community. This report will detail the work done to improve existing PROTEUS workflow support in NiCE. We will demonstrate and discuss these improvements, including the development of flexible IO services, an improved interface for input generation, and the addition of advanced Fortran development tools natively in the platform.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STEM Imaging of Materials: Final Report for DE-FG02-08ER46547

This project supported research advancing the state of the art in scanning transmission electron microscopy (STEM) imaging and characterization of materials, especially electronic materials. The project began with studies of point defects in materials using high-resolution Z-contrast STEM, then evolved to including methods in four-dimensional (4D) STEM and machine learning. Highlights include: (1) the discovery of stable, p-type ZnO via Sb doping, (2) demonstration that the high performance of InGaN LEDs is not due to In composition fluctuations as previously proposed, (3) the demonstration of the first sub-pm precision high-resolution STEM images using non-rigid registration of a series of STEM images, (4) the extension of high-precision STEM to low dose imaging and spectrum imaging, (5) discovery of a synthesis method for twisted spiral growth of transition-metal dichalcogenide materials via chemical vapor deposition, and (6) development of machine-learning methods for analysis and denoising of enormous 4D STEM data sets.

36 MATERIALS SCIENCE↗

Editorial: Benchmark experiments, development and needs in support of advanced reactor design

Advanced nuclear reactor designs will for the most part be a departure from low enrichment light water reactor (LWR) designs currently operated around the world. Such advanced designs include but are not limited to new TRISO-fueled high temperature gas reactors, heat-pipe cooled micro-reactors, fluoride salt cooled high-temperature reactors, molten salt reactors, lead cooled fast reactors, nuclear thermal propulsion concepts, and include LWR designs with advanced fuel and clad types. Modeling and simulation methods for advanced reactors is necessary for regulators to approve license requests. However, regulators also require that modeling approaches be validated against experimental measurements. Hence, there is a crucial need for data for advanced reactor systems that will support validation of analysis methods. To this end, this Research Topic includes eleven papers organized into topical seven categories relevant for advanced reactor design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Soil Water Characteristics of Cores from Low- and High-Centered Polygons, Utqiagvik (Barrow), Alaska, 2012

This dataset includes soil water characteristic curves for soil and permafrost in two representative frozen cores collected from a high-center polygon (HCP) and a low-center polygon (LCP) from the Barrow Environmental Observatory. Data include soil water content and soil water potential measured using the simple evaporation method for hydrological and biogeochemical simulations and experimental data analysis. Data can be used to generate a soil moisture characteristic curve, which can be fit to a variety of hydrological functions to infer critical parameters for soil physics. Considering the measured the soil water properties, the van Genuchten model predicted well the HCP, in contrast, the Kosugi model well fitted LCP which had more saturated condition. This dataset includes 8 zipped files, one txt files, and one pdf file.Data were collected to estimate soil water potential and water availability at various temperatures and conditions for hydrological and biogeochemical simulations and experimental data analysis. Data can be used to generate a soil moisture characteristic curve, which can be fit to a variety of hydrological functions to infer critical parameters for soil physics.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

System and method for simulation-assisted additive manufacturing involving estimating anisotropic deformation

A simulation-assisted additive manufacturing system and method for generating an anisotropic compensation to account for non-uniform deformation due to additive manufacturing and service loading. The predicted deformation may not be fully defined. The present disclosure provides a system and method for estimating the missing deformation data through regression analysis. The present disclosure also provides an integrated framework where the various simulated-assisted design modules are configured for two-way communication and sharing access to changes to the model.

Kim, Seokpum↗

Software Quality Metrics for Geant4: An Initial Assessment - Paper 122

In the context of critical applications, such as shielding and radiation protection, ensuring the quality of simulation software they depend on is of utmost importance. The assessment of simulation software quality is crucial both to determine its adoption in experimental applications and to guarantee reproducibility of outcome over time. Geant4 is a simulation system used in a wide range of experimental applications, some of which, such as radiation protection and biomedical studies, may involve critical use cases and would especially profit from an objective assessment of the software quality. In this study, we present the first results from an ongoing analysis of Geant4 code based on established software metrics from the perspective of software engineering. The analysis evaluates the current status of the code to quantify its characteristics with respect to documented quality standards; further appraisals concern evolutions over a series of release distributions. The quantitative assessment of the software is initially focused on a subset of Geant4 packages, which play a key role in scientific applications and are representative of different software development processes. We describe the chosen software metrics that map the entities of a software system to numeric values through mathematical definitions, quantifying software attributes ranging from functionality to maintainability. To measure such metrics, we exploited a set of software metrics tools, i.e. programs that implement a set of software metrics definitions. They allow software engineers to assess a software system by extracting the required attributes from the software and providing the corresponding metric values. To correlate software metrics values in a well-defined way, we used software quality standard models, such as the ISO/IEC 9126 standard, which aggregate numerical values to aid quality analysis and assessment. With this work we aim to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. Furthermore, we intend to highlight what metrics are most effective at evaluating radiation transport software quality. We are confident that the result will provide constructive guidance both to improve key software tools, such as Geant4, and to estimate their contribution in risk analysis concerning sensitive applications. The remainder of this paper is structured as follows. We first discuss the approach adopted to fulfil our assessment. Then, we present the setup of our experiments and the way we collected data. We provide an initial interpretation of a subset of data resulting from measurements made on the selected Geant4 packages. As the analysis is still ongoing at the time of submitting this abstract, some results will be documented in the final paper and in the conference presentation. With this work we aim to create a proper Geant4 data set for evaluating its software characteristics and identifying both strengths and weaknesses. In this initial study, we considered the geometry and processes packages, which play a major role in most simulation applications. The data analysis is in progress at the time of writing; its complexity is related to the differences among software metrics tools, to the large amount of data to be evaluated and to the pioneering character of this project. We are confident that the results will provide valuable indications for the Geant4 user community and constructive guidance to improve key Geant4 packages. Other Monte Carlo codes could profit from the methodology developed in this pilot project for similar assessments of their software quality. At the end of this study, we intend to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Relating the structure of geminal amido esters to their molecular hyperpolarizability

Advanced organic non-linear optical (NLO) materials have attracted increasing attention due to their multitude of applications in modern telecommunication devices. Arguably the most important advantage of organic NLO materials, relative to traditionally used inorganic NLO materials, is their short optical response time. Geminal amido esters with their donor-x-acceptor (D-π-A) architecture exhibit high levels of electron delocalization and substantial intramolecular charge transfer, which should endow these materials with short optical response times and large molecular (hyper)polarizabilities. In order to test this hypothesis, the linear and second-order non-linear optical properties of five geminal amido esters, ( E )-ethyl 3-(X-phenylamino)-2-(Y-phenylcarbamoyl)acrylate (1: X = 4-H,Y = 4-H; 2: X= 4-CH 3 , Y = 4-CH 3 ; 3: X = 4-NO 2 , Y = 2,5-OCH 3 ; 4: X = 2-Cl, Y = 2-Cl; 5: X = 4-Cl, Y = 4-Cl) were synthesized and characterized, whereby NLO structure-function relationships were established including intramolecular charge transfer characteristics, crystal field effects, and molecular first hyperpolarizabilities β. Given the typically large errors (10-30%) associated with the determination of (β) coefficients, three independent methods were used: i) density functional theory, ii) hyper-Rayleigh scattering, and iii) high-resolution X-ray diffraction data analysis based on multipolar modeling of electron densities at each atom. These three methods delivered consistent values of β, and based on these results, 3 should hold the most promise for NLO applications. In conclusion, the correlation between the molecular structure of these geminal amido esters and their linear and non-linear optical properties thus provide molecular design guidelines for organic NLO materials; this leads to the ultimate goal of generating bespoke organic molecules to suit a given NLO device application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗