Monte Carlo interpretation of the AMMON/REF experiment in EOLE for the JHR reactor calculations

A new experiment, named AMMON and dedicated to the analysis of the JHR neutron physics and to the qualification of the associated neutron calculation tools, is currently in progress in the EOLE zero-power experimental reactor at CEA Cadarache. The first core configuration, so called 'reference configuration' (AMMON/REF) has already been loaded: it consists of an experimental zone of 7 JHR assemblies with U{sub 3}Si{sub 2} 27% {sup 235}U enriched fuel curved plates surrounded by a driver zone with 623 standard PWR UOx fuel pins. The analysis of the AMMON/REF measurements is presented in this paper. It is based on calculations performed with the 3-dimensional reference Monte Carlo TRIPOLI4.7 code and the JEFF3.1.1 European library: it highlights a good agreement between calculation and experiment concerning reactivity and power distribution in the experimental zone. Reactivity prediction is very satisfactory, despite the presence of a large aluminum quantity in the core: C-E=+ 376 pcm {+-} 290. The radial and axial plate power profiles are also in good agreement. Assembly power distribution is predicted within the experimental uncertainties (1{sigma}). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RAPTURE User's Manual

This User's Guide serves as a brief introduction to the RAPTURE radiation effects analysis code. It includes an overview of the input format, RAPTURE's error- and consistency-checking of the user-provided input files, the automatic-differentiation and convergce-checking schemes employed by RAPTURE, and the RAPTURE output files. A variety of example problems are included in this Guide which collectively demonstrate RAPTURE's current capabilities and provide a suite of test problems and template input files for the user. This Guide includes, for each problem, the problem description, RAPTURE input files, and comparison of the RAPTURE solution with solutiong generated with the Monte Carlo transport code ITS, the legacy deterministic code ADEPT, and, where possible, published experimental results. An appendix includes a description of all keywords and options in the RAPTURE input file.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Protection for the First Korea Heavy-ion Medical Accelerator (KHIMA) Facility - Paper 7

The number of particle therapy facilities is increasing worldwide due to the encouraging results obtained at research facilities such as the Lawrence Berkeley National Laboratory (USA), the Helmholtz Center for Heavy Ion Research GSI (Germany), and the Heavy Ion Medical Accelerator (HIMAC) in Chiba (Japan). The first hospital-based heavy-ion therapy facility is under construction in Busan, Korea, at the Korea Institute of Radiological and Medical Sciences [KIRAMS]. The project was originally designed to develop a compact superconducting cyclotron for hadron therapy able to deliver forefront beams of heavier ions, essentially carbon ions of energy, 430 MeV/u. Radiation protection issues play an important role in every stage of the project such as civil construction planning, control system design, and special technological plants. Monte Carlo transport codes are the best tools to solve these issues and the FLUKA2011 and MCNPX2.7.0 codes are used in this work. Beam loss distributions of cyclotron installations in combination with passive or active beam shaping methods have a particularly high implication on the protection layout of the facility. Methods for shielding and activation calculations are described with an emphasis on carbon ion beams. All the tools and databases require verification. Benchmarking is an instrumental process for verification. An overview of benchmarking efforts will also be given and the need for further benchmarks is discussed. (authors)

43 PARTICLE ACCELERATORS↗

Neutron counter based on beryllium activation

The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlated prompt fission data in transport simulations

Detailed information on the fission process can be inferred from the observation, modeling and theoretical understanding of prompt fission neutron and γ-ray observables. Beyond simple average quantities, the study of distributions and correlations in prompt data, e.g., multiplicity-dependent neutron and γ-ray spectra, angular distributions of the emitted particles, n -n, n - γ, and γ - γ correlations, can place stringent constraints on fission models and parameters that would otherwise be free to be tuned separately to represent individual fission observables. The FREYA and CGMF codes have been developed to follow the sequential emissions of prompt neutrons and γ rays from the initial excited fission fragments produced right after scission. Both codes implement Monte Carlo techniques to sample initial fission fragment configurations in mass, charge and kinetic energy and sample probabilities of neutron and γ emission at each stage of the decay. This approach naturally leads to using simple but powerful statistical techniques to infer distributions and correlations among many observables and model parameters. The comparison of model calculations with experimental data provides a rich arena for testing various nuclear physics models such as those related to the nuclear structure and level densities of neutron-rich nuclei, the γ-ray strength functions of dipole and quadrupole transitions, the mechanism for dividing the excitation energy between the two nascent fragments near scission, and the mechanisms behind the production of angular momentum in the fragments, etc. Beyond the obvious interest from a fundamental physics point of view, such studies are also important for addressing data needs in various nuclear applications. The inclusion of the FREYA and CGMF codes into the MCNP6.2 and MCNPX - PoliMi transport codes, for instance, provides a new and powerful tool to simulate correlated fission events in neutron transport calculations important in nonproliferation, safeguards, nuclear energy, and defense programs. Here, this review provides an overview of the topic, starting from theoretical considerations of the fission process, with a focus on correlated signatures. It then explores the status of experimental correlated fission data and current efforts to address some of the known shortcomings. Numerical simulations employing the FREYA and CGMF codes are compared to experimental data for a wide range of correlated fission quantities. The inclusion of those codes into the MCNP6.2 and MCNPX - PoliMi transport codes is described and discussed in the context of relevant applications. The accuracy of the model predictions and their sensitivity to model assumptions and input parameters are discussed. Lastly, a series of important experimental and theoretical questions that remain unanswered are presented, suggesting a renewed effort to address these shortcomings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of energy relaxation of H{sup 0} atoms at the wall on the production profile of H{sup -} ions in large negative ion sources

Production and transport processes of the H{sup 0} atoms are numerically simulated using a three-dimensional Monte Carlo transport code. The code is applied to the large JAEA 10 ampere negative ion source under a Cs-seeded condition to obtain a spatial distribution of surface-produced H{sup -} ions. In this analysis, we focus on the effect of the energy relaxation of the H{sup 0} atoms at the wall on the H{sup -} ion production from the H{sup 0} atoms. The result indicates that, by considering the energy relaxation of the H{sup 0} atoms at the wall, the production profile of the surface-produced H{sup -} ion is well reflected in the production profile of the H{sup 0} atom production.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of Trapping Impurities on He Desorption and Clustering in Irradiated a-Fe

It is well-known that impurities affect the migration of intrinsic point defects in metals. For instance, carbon is a common impurity in Fe that significantly retards diffusion of vacancies. Under fusion irradiation conditions, high levels of He are produced by transmutation reactions. This element strongly interacts with vacancies produced during irradiation and agglomerate into stable He-vacancy clusters that can deteriorate the mechanical properties of the material. A physically-based model accounting for the interactions between He, point defects (interstitials and vacancies) and trapping impurities is therefore necessary to understand and predict damage evolution in Fe. We have used a multi-scale approach to predict the evolution of He in the presence of impurities in irradiated Fe. Density Functional Theory (DFT) calculations were performed to investigate the migration mechanisms and to determine the activation energies of the different atomistic processes. The influence of impurities - such as carbon - on the binding energies of small He-vacancy clusters was also studied. Using the information obtained by DFT a physically-based model was developed and implemented in a kinetic Monte Carlo (kMC) code to follow the evolution of He in Fe. In addition, a model based on the rate theory (RT) was developed in order to achieve larger simulation times and volumes. Results obtained with this model, which is based on a mean field approximation are compared to those obtained with kMC. Using this multi-scale approach, the simulation results are used to interpret the different stages of thermal He desorption experiments and to determine the predominant migration mechanism. The influence of impurities which affect the diffusion of point defects or modify the binding energies of He-vacancy type clusters is also studied. (authors)

36 MATERIALS SCIENCE↗

OpenEdge: A collaborative, open-source, multi-purpose direct simulation Monte Carlo for plasma simulation in magnetic fusion environments

OpenEdge is a collaborative, open-source, object-oriented Direct Simulation Monte Carlo (DSMC) code, designed specifically for plasma simulations in magnetic fusion environments. Here, the code features include advanced structures, robust capabilities, and an effective parallelization strategy, all of which significantly enhance performance. It includes specialized modules for managing complex particle interactions, including collisions, ionization/recombination, and reflection/sputtering. Benchmarks and performance analyses have confirmed its efficiency and scalability. Versatile and adaptable, OpenEdge is applied across a broad spectrum of plasma-material interaction studies and charged particle transport in various fusion research settings.

Boundary plasma↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

Erosion of Extraction Electrodes of Ion Sources due to Sputtering

The effects upon erosion due to implanted atoms in extraction electrodes of an ion source have been investigated through calculating the sputtering yields with a Monte Carlo simulation code, ACAT. The results obtained with ACAT have indicated that the sputtering yields of extraction electrodes are substantially affected by the retention of implanted atoms depending upon the mass ratio of electrode materials and extracted ions from the source plasma. The enhanced erosion takes place as the heavier ion beam species like phosphor is implanted into lighter electrode material like carbon. Additional mixing of materials arising from ion source operation, such as hot cathode materials evaporation onto a carbon extraction electrode, can shorten the lifetime of the extraction electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photonuclear reaction based high-energy x-ray spectrometer to cover from 2 MeV to 20 MeV

A photonuclear-reaction-based hard x-ray spectrometer is developed to measure the number and energy spectrum of fast electrons generated by interactions between plasma and intense laser light. In this spectrometer, x-rays are converted to neutrons through photonuclear reactions, and the neutrons are counted with a bubble detector that is insensitive to x-rays. The spectrometer consists of a bundle of hard x-ray detectors that respond to different photon-energy ranges. Proof-of-principle experiment was performed on a linear accelerator facility. A quasi-monoenergetic electron bunch (N{sub e} = 1.0 × 10{sup −6} C, E{sub e} = 16 ± 0.32 MeV) was injected into a 5-mm-thick lead plate. Bremsstrahlung x-rays, which emanate from the lead plate, were measured with the spectrometer. The measured spectral shape and intensity agree fairly well with those computed with a Monte Carlo simulation code. The result shows that high-energy x-rays can be measured absolutely with a photon-counting accuracy of 50%–70% in the energy range from 2 MeV to 20 MeV with a spectral resolution (Δhν/hν) of about 15%. Quantum efficiency of this spectrometer was designed to be 10{sup −7}, 10{sup −4}, 10{sup −5}, respectively, for 2–10, 11–15, and 15–25 MeV of photon energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-185: Study of the Robustness of a Proton Arc Technique Based On PBS Beams

Purpose: One potential technique to realize proton arc is through using PBS beams from many directions to form overlaid Bragg peak (OBP) spots and placing these OBP spots throughout the target volume to achieve desired dose distribution. In this study, we analyzed the robustness of this proton arc technique. Methods: We used a cylindrical water phantom of 20 cm in radius in our robustness analysis. To study the range uncertainty effect, we changed the density of the phantom by ±3%. To study the setup uncertainty effect, we shifted the phantom by 3 & 5 mm. We also combined the range and setup uncertainties (3mm/±3%). For each test plan, we performed dose calculation for the nominal and 6 disturbed scenarios. Two test plans were used, one with single OBP spot and the other consisting of 121 OBP spots covering a 10×10cm{sup 2} area. We compared the dose profiles between the nominal and disturbed scenarios to estimate the impact of the uncertainties. Dose calculation was performed with Gate/GEANT based Monte Carlo software in cloud computing environment. Results: For each of the 7 scenarios, we simulated 100k & 10M events for plans consisting of single OBP spot and 121 OBP spots respectively. For single OBP spot, the setup uncertainty had minimum impact on the spot’s dose profile while range uncertainty had significant impact on the dose profile. For plan consisting of 121 OBP spots, similar effect was observed but the extent of disturbance was much less compared to single OBP spot. Conclusion: For PBS arc technique, range uncertainty has significantly more impact than setup uncertainty. Although single OBP spot can be severely disturbed by the range uncertainty, the overall effect is much less when a large number of OBP spots are used. Robustness optimization for PBS arc technique should consider range uncertainty with priority.

60 APPLIED LIFE SCIENCES↗

Fast-ion D{sub {alpha}} measurements and simulations in quiet plasmas

The D{sub {alpha}} light emitted by neutralized deuterium fast ions is measured in magnetohydrodynamics (MHD)-quiescent, magnetically confined plasmas during neutral beam injection. A weighted Monte Carlo simulation code models the fast-ion D{sub {alpha}} spectra based on the fast-ion distribution function calculated classically by TRANSP [R. V. Budny, Nucl. Fusion 34, 1247 (1994)]. The spectral shape is in excellent agreement and the magnitude also has reasonable agreement. The fast-ion D{sub {alpha}} signal has the expected dependencies on various parameters including injection energy, injection angle, viewing angle, beam power, electron temperature, and electron density. The neutral particle diagnostic and measured neutron rate corroborate the fast-ion D{sub {alpha}} measurements. The relative spatial profile agrees with TRANSP and is corroborated by the fast-ion pressure profile inferred from the equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo simulation of an x-ray volume imaging cone beam CT unit

In this work the authors characterized the radiation field produced by a kilovolt cone beam computed tomography (CBCT) unit integrated in the Elekta Synergy linear accelerator. The x-ray volume imaging (XVI) radiation unit was modeled in detail using the BEAMNRC Monte Carlo (MC) code system. The simulations of eight collimator cassettes and the neutral filter F0 were successfully carried out. MC calculations from the EGSNRC code DOSXYZNRC were benchmarked against measurements in water. A large set of depth dose and lateral profiles was acquired with the ionization chamber in water, with the x-ray tube in a stationary position, and with the beam energy set to 120 kV. Measurements for all the available collimator cassettes were compared with calculations, showing very good agreement (<2% in most cases). Furthermore, half value layer measurements were carried out and used to validate the MC model of the XVI unit. In this case dose calculations were performed with the EGSNRC code cavity and these showed excellent agreement. In this manuscript the authors also report on the optimization work of the relevant parameters that influenced the development of the MC model. The dosimetric part of this work was very useful in characterizing the XVI radiation output for the energy of interest. The detailed simulation part of the work is the first step toward an accurate MC based assessment of the dose delivered to patients during routine CBCT scans for image and dose guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling blur in various detector geometries for MeV radiography

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for applications in MeV radiography. Segmented scintillating detectors, where low Z scintillators combined with a high-Z metal matrix, can be designed in which the resolution increases with increasing metal fraction. Here, the combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution. Select detector geometries were tested by comparing simulation and experimental modulation transfer functions to validate the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation of the Conversion X-Rays from the Electron Beam of PFMA-3

PFMA-3, a dense Plasma Focus device, is being optimized as an X-ray generator. X-rays are obtained from the conversion of the electron beam emitted in the backward direction and driven to impinge on a 50 {mu}m brass foil. Monte Carlo simulations of the X-ray emission have been conducted with MCNPX. The electron spectrum had been determined experimentally and is used in the present work as input to the simulations. Dose to the brass foil has been determined both from simulations and from measurements with a thermographic camera, and the two results are found in excellent agreement, thus validating further the electron spectrum assumed as well as the simulation set-up. X-ray emission has been predicted both from bremsstrahlung and from characteristic lines. The spectrum has been found to be comprised of two components of which the one at higher energy, 30 divide 70 keV, is most useful for IORT applications. The results are necessary to estimate penetration in and dose to Standard Human Tissue.

43 PARTICLE ACCELERATORS↗