Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

The CMS RPC system readiness for LHC Run-3 data taking

During Run-3, the LHC is preparing to deliver instantaneous luminosity in the range from 5 × 10 34 cm -2 s -1 to 7.5 × 10 34 cm -2 s -1 . To ensure stable data taking, providing redundant information for robust muon triggering, reconstruction and identification, the CMS RPC collaboration has used the opportunity given by the LHC long shutdown 2 (LS2), to perform a series of maintenance and preparation activities for the new data taking period. The overall performance of the RPC system after the LS2 commissioning period and the activities in preparation for future data taking will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lanthanum halide nanoparticle scintillators for nuclear radiation detection

Nanoparticles with sizes <10 nm were fabricated and characterized for their nanocomposite radiation detector properties. This work investigated the properties of several nanostructured radiation scintillators, in order to determine the viability of using scintillators employing nanostructured lanthanum trifluoride. Preliminary results of this investigation are consistent with the idea that these materials have an intrinsic response to nuclear radiation that may be correlated to the energy of the incident radiation.

36 MATERIALS SCIENCE↗

Quantitative hard x-ray phase contrast imaging of micropipes in SiC

Peculiarities of quantitative hard x-ray phase contrast imaging of micropipes in SiC are discussed. The micropipe is assumed as a hollow cylinder with an elliptical cross section. The major and minor diameters can be restored using the least square fitting procedure by comparing the experimental data, i.e. the profile across the micropipe axis, with those calculated based on phase contrast theory. It is shown that one projection image gives an information which does not allow a complete determination of the elliptical cross section, if an orientation of micropipe is not known. Another problem is a weak accuracy in estimating the diameters, partly because of using pink synchrotron radiation, which is necessary because a monochromatic beam intensity is not sufficient to reveal the weak contrast from a very small object. The general problems of accuracy in estimating the two diameters using the least square procedure are discussed. Two experimental examples are considered to demonstrate small as well as modest accuracies in estimating the diameters.

36 MATERIALS SCIENCE↗

An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the neutron electric dipole moment experiment at the Spallation Neutron Source

In this study, we have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ~600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1–2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, I < 1 pA at 45 kV, correspond to a lower bound on the effective volume resistivity of liquid helium of ρ V > 5 × 10 18 Ω cm. This lower bound is 5 times larger than the bound previously measured. Finally, we report the design, construction, and operational experience of the apparatus, as well as initial results

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A semiempirical transparency model for dual energy cargo radiography applications

Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in which only free streaming photons are detected. However, this approximation neglects second order effects such as scattering, leading to a biased model and thus incorrect material predictions. This work studies the accuracy of the free streaming model by comparing it to simulation outputs, finding that the model shows poor atomic number reconstruction accuracy at high- Z and suffers significantly if the source energy spectra and detector response function are not known exactly. To address these challenges, this work introduces a semiempirical transparency model which modifies the free streaming model by rescaling different components of the mass attenuation coefficient, allowing the model to capture secondary effects ignored by the free streaming model. The semiempirical model displays improvement agreement with simulated results at high- Z and shows excellent extrapolation to materials and thicknesses which were not included during the calibration step. Furthermore, this work demonstrates that the semiempirical model yields accurate atomic number predictions even when the source spectra and detector response are not known exactly. In conclusion, using the semiempirical model, manufacturers can perform a simple calibration to enable more precise Z reconstruction capabilities, which has the potential to significantly improve the performance of existing dual energy radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactions

The increasing adoption of accelerator-based neutron sources (ABNS) for applications including neutron capture therapy (NCT) research has highlighted the need for accurate simulation tools. Precise modelling of the neutron production target is crucial to ensure that simulated predictions of neutron beam characteristics used for subsequent beam shaping assembly design are reliable. This work presents a comprehensive benchmarking of four widely-used Monte Carlo codes - Geant4, PHITS, FLUKA (CERN), and MCNP - for modelling low-energy neutron production target reactions. Using their recommended physics models and cross-section libraries, we evaluate each code’s performance in simulating four beam-target reactions: 7 Li(p,n) 7 Be, 9 Be(p,n) 9 B, 9 Be(d,n) 10 B, and C(d,n)N. Predictions of neutron yield, angular distributions, and energy spectra are compared against available thick target experimental data. Results show varying levels of agreement between the codes depending on the reaction type, energy range, and beam characteristics. Geant4, MCNP and PHITS are the overall best performing codes for the simulation of total neutron yield and yield in the forward direction across most reactions. Across energies where experimental benchmarks exist, inter-code discrepancies in total and forward-directed yield are typically 10 to 30%, with larger deviations at near-threshold incident ion energies. PHITS provides the best overall reproduction of experimental spectra, particularly for the 9 Be(p,n) 9 B reaction. Additionally, PHITS demonstrates superior computational performance for most reactions. These findings provide valuable guidance for ABNS design, highlighting the strengths and limitations of each code for the simulation of low-energy neutron production reactions.

43 PARTICLE ACCELERATORS↗

Thermal Stability of LiNi x Mn y Co z O 2 Cathode Materials

Here, the thermal evolution of LiNi x Mn y Co z O 2 (NMC) lithium-ion battery electrode materials is examined at various states of charge (SOC) or lithium concentrations for a variety of Ni:Mn:Co ratios or electrode compositions. Synchrotron X-ray diffraction (XRD) combined with Rietveld analysis shows the onset decomposition temperatures of phases, decomposition products, lattice parameters, and phase fractions as a function of composition and SOC. SOC impacts the lattice parameters of the NMC phase, where a collapse of the c-axis in the NMC phases is noted due to lithium extraction. Among the compositions examined, the low-Ni NMC111 uncycled sample (NMC111 0% SOC) exhibited the highest thermal stability, with a decomposition temperature approximately 250 °C higher than that of NMC532 0% and NMC811 0%. When the SOC exceeds 50% (i.e., more than 0.4 mol of Li ions extracted), the influence of Ni content on the decomposition temperature becomes negligible, with decomposition occurring around 250−300 °C for all compositions. Ni content also affects the decomposition pathways: NMC111 tends to first form a TM 3 O 4 -type phase, where TM represents transition metals, before transforming into a TMO-type phase, whereas most of the NMC811 samples directly decompose into the TMO phase. The presence of metallic phases was confirmed by both XRD and thermogravimetric-differential scanning calorimetry (TGA-DSC) analysis, as a result of heating under inert conditions. The TGA-DSC results suggest that metallic phase formation is favored at lower SOC in samples with a higher Ni content. This work provides comprehensive insight into the thermal degradation pathways of NMC materials as a function of composition, SOC, and temperature.

Peng, Jian [Univ. of New South Wales, Sydney, NSW ↗

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

DNP-enhanced ultrawideline 207 Pb solid-state NMR spectroscopy: an application to cultural heritage science

Dynamic nuclear polarization (DNP) is used to enhance the (ultra)wideline 207 Pb solid-state NMR spectra of lead compounds of relevance in the preservation of cultural heritage objects. The DNP SSNMR experiments enabled, for the first time, the detection of the basic lead carbonate phase of the lead white pigment by 207 Pb SSNMR spectroscopy. Variable-temperature experiments revealed that the short T'2 relaxation time of the basic lead carbonate phase hinders the acquisition of the NMR signal at room temperature. We additionally observe that the DNP enhancement is twice as large for lead palmitate (a lead soap, which is a degradation product implicated in the visible deterioration of lead-based oil paintings), than it is for the basic lead carbonate. As a result, this enhancement has allowed us to detect the formation of a lead soap in an aged paint film by 207 Pb SSNMR spectroscopy; which may aid in the detection of deterioration products in smaller samples removed from works of art.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

FY 2009 Advanced Test Reactor National Scientific User Facility User's Guide

Collaborative development of nuclear energy science and technology by three major sectors— academia, the commercial nuclear power industry, and the federal government—is key to meeting challenges in the development of nuclear energy. All three share a common need for experimental capabilities, whether for basic science investigations, applied research in nuclear fuels and materials or validation of data. In April 2007, to fill this need, the U.S. Department of Energy (DOE) Deputy Secretary of Energy designated the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) as a National Scientific User Facility (NSUF). The Office of Nuclear Energy (NE), the Office of Science, and Office of Naval Nuclear Propulsion Programs, or Naval Reactors (NR) strongly endorsed the action. While functioning as a NSUF, the ATR will continue to support its current national missions. This document provides a guide for prospective experimenters interested in performing irradiation research in the ATR. The following contains a brief discussion of the NSUF objectives, a description of the ATR and its experiment capabilities, the ancillary capabilities of the INL to support irradiation experiment development and Post Irradiation Examination (PIE), the process for users to follow to conduct an irradiation experiment, the conditions that apply to experimenters, and the technical requirements for materials inserted into the ATR test positions. This document is not intended to provide all the necessary information required to perform an experiment in the ATR, but will serve as a guide to concept development and initial experiment planning. An experienced team of INL researchers will work with experimenters to ensure that all experiments comply with all INL and ATR requirements.

36 MATERIALS SCIENCE↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗