Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Compact fission counter for DANCE

The Detector for Advanced Neutron Capture Experiments (DANCE) consists of 160 BF{sub 2} crystals with equal solid-angle coverage. DANCE is a 4{pi} {gamma}-ray calorimeter and designed to study the neutron-capture reactions on small quantities of radioactive and rare stable nuclei. These reactions are important for the radiochemistry applications and modeling the element production in stars. The recognition of capture event is made by the summed {gamma}-ray energy which is equivalent of the reaction Q-value and unique for a given capture reaction. For a selective group of actinides, where the neutron-induced fission reaction competes favorably with the neutron capture reaction, additional signature is needed to distinguish between fission and capture {gamma} rays for the DANCE measurement. This can be accomplished by introducing a detector system to tag fission fragments and thus establish a unique signature for the fission event. Once this system is implemented, one has the opportunity to study not only the capture but also fission reactions. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to {alpha} particles, which is important for experiments with {alpha}-emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. A PPAC with an ingenious design was fabricated in 2006 by integrating amplifiers into the target assembly. However, this counter was proved to be unsuitable for this application because of issues related to the stability of amplifiers and the ability to separate fission fragments from {alpha}'s. Therefore, a new design is needed. A LLNL proposal to develop a new PPAC for DANCE was funded by NA22 in FY09. The design goal is to minimize the mass for the proposed counter and still be able to maintain a stable operation under extreme radioactivity and the ability to separate fission fragments from {alpha}'s. In the following sections, the description is given for the design and performance of this new compact PPAC, for studying the neutron-induced reactions on actinides using DANCE at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulating Blade-Strike on Fish passing through Marine Hydrokinetic Turbines

The study reported here evaluated the occurrence, frequency, and intensity of blade strike of fish on an axial-flow marine hydrokinetic turbine by using two modeling approaches: a conventional kinematic formulation and a proposed Lagrangian particle- based scheme. The kinematic model included simplifying assumptions of fish trajectories such as distribution and velocity. The proposed method overcame the need for such simplifications by integrating the following components into a computational fluid dynamics (CFD) model: (i) advanced eddy-resolving flow simulation, (ii) generation of ambient turbulence based on field data, (iii) moving turbine blades in highly transient flows, and (iv) Lagrangian particles to mimic the potential fish pathways. The test conditions to evaluate the blade-strike probability and fish survival rate were: (i) the turbulent environment, (ii) the fish size, and (iii) the approaching flow velocity. The proposed method offered the ability to produce potential fish trajectories and their interaction with the rotating turbine. Depending upon the scenario, the percentile of particles that registered a collision event ranged from 6% to 19% of the released sample size. Next, by using a set of experimental correlations of the exposure-response of living fish colliding with moving blades, the simulated collision data were used as input variables to estimate the survival rate of fish passing through the operating turbine. The resulting survival rates were greater than 96% in all scenarios, which is comparable to or better than known survival rates for conventional hydropower turbines. The figures of strike probability and mortality rate were amplified by the kinematic model. The proposed method offered the advantage of expanding the evaluation of other mechanisms of stress and injury on fish derived from hydrokinetic turbines and related devices.

CFD↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance studies of Hamamatsu R9800 photomultiplier tube with a new active base designed for use in the Hall D Broadband tagger Hodoscope

This paper presents the results of a study of a high rate photomultiplier and active base assembly designed for use in scintillator counters of the Hall D Jefferson Lab Broadband fixed-array Tagging Hodoscope. In its standard configuration the fixed-array hodoscope consists of 218 plastic scintillator counters made with Hamamatsu R9800 one inch in diameter photomultiplier tube. All tubes are equipped with designed at JLab new active base. The base comprised of a high voltage divider integrated with amplifiers powered by current flowing through the divider (U.S. Patent No. 6,791,269). This original design allows limiting the PMT anode current to 15-20 uA at a 4 MHz count rate, and allows tube operation at lower high voltage bias voltage while retaining a desired overall gain and dynamic range of output signals. The performance of the PMT assemblies were studied at Jeffeson Lab using a picosecond laser (PLP-10). Subsequently, two hundred fifty PMT and base assemblies were manufactured and tested. The results of testing the R9800 photomultiplier in a new active base are presented and discussed.

Popov, Vladimir↗

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation counter and wire chamber front end modules for high energy physics experiments

This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of {approx}20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with {approx}100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of {approx}4 {micro}s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of {approx}0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative SCR Materials and System for Low Temperature Aftertreatment

US automotive OEMs are required to meet the twin challenge of corporate average fleet fuel economy of 54.5 mpg and stringent Bin30/SULEV30 emissions standards for light duty vehicles by 2025. This creates a heavy burden on the R&D community to discover and develop the necessary enabling technologies by 2023 to integrate into powertrain systems intended for 2025. Further amplifying the emissions challenge is the reduction in engine exhaust energy resulting from more fuel-efficient powertrains and the regulatory requirement of 15-year system performance. This forces aftertreatment systems to continue to push their operational limits to increasingly lower temperatures. This CRADA will focus on a broad and very important area of critical relevance to DOE and Stellantis, i.e., development of low temperature aftertreatment approaches, while not sacrificing durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radio-frequency heating of the coronal plasma during flares

A model is developed for the radio-frequency (RF) heating of soft X-ray emitting plasma in solar flares due to absorption of amplified cyclotron radiation. The radiation, carrying approximately 10 to the 27th to approximately 10 to the 30th erg/s, is generated through maser emission following partial precipitation of electrons in one or more flaring loops. The maser operates in a large number of small regions, each producing an 'elementary burst' (EB) of short duration. This radiation propagates either directly or after reflection to the second-harmonic absorption layer, where it is absorbed by thermal electrons. The properties of EBs and the heating of the electrons in the absorption layer are discussed in detail. RF heating and evaporation models for the production of soft X-ray emitting plasma are compared. Properties of the RF heating model that explain observed features are energy transport across field lines, rapid heating (in approximately 1 s) of coronal plasma to approximately 3 x 10 to the 7th K, and instigation of turbulent velocities up to the ion sound speed.

Melrose, D. B.↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

A DUAL-BAND MILLIMETER-WAVE KINETIC INDUCTANCE CAMERA FOR THE IRAM 30 m TELESCOPE

The Neel IRAM KIDs Array (NIKA) is a fully integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. The instrument includes dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz. The imaging sensors consist of two spatially separated arrays of KIDs. The first array, mounted on the 150 GHz branch, is composed of 144 lumped-element KIDs. The second array (220 GHz) consists of 256 antenna-coupled KIDs. Each of the arrays is sensitive to a single polarization; the band splitting is achieved by using a grid polarizer. The optics and sensors are mounted in a custom dilution cryostat, with an operating temperature of {approx}70 mK. Electronic readout is realized using frequency multiplexing and a transmission line geometry consisting of a coaxial cable connected in series with the sensor array and a low-noise 4 K amplifier. The dual-band NIKA was successfully tested in 2010 October at the Institute for Millimetric Radio Astronomy (IRAM) 30 m telescope at Pico Veleta, Spain, performing in-line with laboratory predictions. An optical NEP was then calculated to be around 2 x 10{sup -16} W Hz{sup -1/2} (at 1 Hz) while under a background loading of approximately 4 pW pixel{sup -1}. This improvement in comparison with a preliminary run (2009) verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically relevant faint and extended objects were then imaged including the Galactic Center SgrB2 (FIR1), the radio galaxy Cygnus A, and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipartite nonlocality distillation

The stronger nonlocality than that allowed in quantum theory can provide an advantage in information processing and computation. Since quantum entanglement is distillable, can nonlocality be distilled in the nonsignalling condition? The answer is positive in the bipartite case. In this article the distillability of the multipartite nonlocality is investigated. We propose a distillation protocol solely exploiting xor operations on output bits. The probability-distribution vectors and matrix are introduced to tackle the correlators. It is shown that only the correlators with extreme values can survive the distillation process. As the main result, the amplified nonlocality cannot maximally violate any Bell-type inequality. Accordingly, a distillability criterion in the postquantum region is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small signal amplifiers and converters for millimeter wave Satcom systems

This paper describes the current state of the art and the various design tradeoffs encompassing the variety of small signal active circuit 'building blocks' deployed in millimeter wave Satcom receivers and transmitters. Included in this catagory are such low noise receiver components as parametric and FET amplifiers and low loss mixer downconverters as well as low level transmitter driver components such as resistive and varactor upconverters. Current and projected state of the art performance data will be presented along with specific examples of operating hardware.

Okean, H. C.↗

Improved charge injection device and a focal plane interface electronics board for stellar tracking

An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.

Michon, G. J.↗

Proposed Ka-band array-fed near field Cassegrain system for NASA's Polar Probe Mission

A Ka-band array-fed near-field Cassegrain antenna envisioned for NASA's Solar Probe Mission is the basis of the present spacecraft telecommunications system, which is designed for operation at X-band up/downlink and Ka-band downlink. The hexagonal array employed, which is located at the Cassegrain point of the 0.75-m reflector, encompasses 37 active elements; each of these contains 1/4-W HEMT amplifiers. Relative to a TWTA-based system, this active array feed reduces mass, increases dc power efficiency, enhanced reliability, and reduces volume requirements.

Kellogg, K.↗

Tuners For Coplanar-Strip Transmission Lines

Sliding radio-frequency short circuits easily adjusted for optimum impedance. Tuning elements developed for use in planar integrated circuits operating at frequencies from about 10 to more than 1,000 GHz. Purpose of such adjustment to adjust impedance presented to circuit connected to nonshorted end of transmission line and thereby optimizes performance of circuit. Mixers, oscillators, amplifiers, couplers, and phase shifters among circuits improved by incorporating tuners of this type.

Mcgrath, William R.↗

Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS Instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗

The Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗