Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Finite Hamiltonian systems: Linear transformations and aberrations

Finite Hamiltonian systems contain operators of position, momentum, and energy, having a finite number N of equally-spaced eigenvalues. Such systems are under the aeis of the algebra su(2), and their phase space is a sphere. Rigid motions of this phase space form the group SU(2); overall phases complete this to U(2). But since N-point states can be subject to U(N) superset of U(2) transformations, the rest of the generators will provide all N{sup 2} unitary transformations of the states, which appear as nonlinear transformations-aberrations-of the system phase space. They are built through the 'finite quantization' of a classical optical system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor system that uses embedded optical fibers

Sensor systems including an interferometer system are disclosed herein. In a general embodiment, the sensor system includes an optical fiber that is embedded into a sample, where the optical fiber has a reflective tip. The optical fiber is optically coupled to a sensor and a detector of the laser interferometer system. The sensor system further includes a computing device or circuit that is configured to receive electrical signals generated by the detector. The laser source is configured to emit light, which is coupled into the optical fiber. The light travels through the optical fiber until the light reaches the reflective tip, where it is reflected back through the optical fiber. The detector is impacted by the reflected light, and generates an electrical signal based upon the reflected light. The computing device generates a value that is indicative of a behavior of the sample based upon the electrical signal.

Chavez, Marcus Alexander↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super Long Conductive Canal for Energy Delivery from Space

The goal of the project is to accomplish a circle of experimental, engineering and technological works on creation of long conductive guide for energy delivery from space. High repetition rate pulse-periodic laser system and the most important components for the project realization will be presented. Optical system for long range energy delivery will be discussed in details. Some new applications of energy delivery system are highlighted.

47 OTHER INSTRUMENTATION↗

Analysis of spatial pseudodepolarizers in imaging systems

The objective of a number of optical instruments is to measure the intensity accurately without bias as to the incident polarization state. One method to overcome polarization bias in optical systems is the insertion of a spatial pseudodepolarizer. Both the degree of depolarization and image degradation (from the polarization aberrations of the pseudodepolarizer) are analyzed for two depolarizer designs: (1) the Cornu pseudodepolarizer, effective for linearly polarized light, and (2) the dual Babinet compensator pseudodepolarizer, effective for all incident polarization states. The image analysis uses a matrix formalism to describe the polarization dependence of the diffraction patterns and optical transfer function.

Mcguire, James P., Jr.↗

WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The OTGS offers a workflow-friendly, patient-friendly solution for intracranial SRT, while being comparable to other real-time options. The minimum rotation uncertainty of the OTGS can be combined with CBCT to ensure maximum accuracy for high-precision SRT.

60 APPLIED LIFE SCIENCES↗

Intrinsic Fiber Optic Chemical Sensors for Subsurface Detection of CO 2

Intelligent Optical Systems, Inc. has developed distributed intrinsic fiber optic sensors to directly quantify the concentration of dissolved or gas-phase CO 2 for leak detection or plume migration in carbon capture and sequestration (CCS). The capability of the sensor for highly sensitive detection of CO 2 in the pressure and temperature range of 15 to 2,000 psi and 25°C to 175°C was demonstrated, as was the capability of operating in highly corrosive and contaminated environments such as those often found in CO 2 injection sites. The novel sensor system was for the first time demonstrated deployed in a deep well, detecting multiple CO 2 releases, in real time, at varying depths. Early CO 2 release detection, by means of a sensor cable integrating multiple sensor segments, was demonstrated, as was the capability of quantifying the leak. The novel fiber optic sensor system exhibits capabilities not achieved by any other monitoring technology. This project represents a breakthrough in monitoring capabilities for CCS applications.

54 ENVIRONMENTAL SCIENCES↗

HIGH RESOLUTION H{alpha} IMAGES OF THE BINARY LOW-MASS PROPLYD LV 1 WITH THE MAGELLAN AO SYSTEM

We utilize the new Magellan adaptive optics system (MagAO) to image the binary proplyd LV 1 in the Orion Trapezium at H{alpha}. This is among the first AO results in visible wavelengths. The H{alpha} image clearly shows the ionization fronts, the interproplyd shell, and the cometary tails. Our astrometric measurements find no significant relative motion between components over {approx}18 yr, implying that LV 1 is a low-mass system. We also analyze Large Binocular Telescope AO observations, and find a point source which may be the embedded protostar's photosphere in the continuum. Converting the H magnitudes to mass, we show that the LV 1 binary may consist of one very-low-mass star with a likely brown dwarf secondary, or even plausibly a double brown dwarf. Finally, the magnetopause of the minor proplyd is estimated to have a radius of 110 AU, consistent with the location of the bow shock seen in H{alpha}.

79 ASTRONOMY AND ASTROPHYSICS↗

Derivation of closed-form ellipsoidal X-ray mirror shapes from Fermat's principle

Ellipsoidal and plane-elliptical surfaces are widely used as reflective, point-to-point focusing elements in many optical systems, including X-ray optics. Here the classical optical path function approach of Fermat is applied to derive a closed-form expression for these surfaces that are uniquely described by the object and image distances and the angle of incidence at a point on a mirror surface. A compact description facilitates design, modeling, fabrication, and testing to arbitrary accuracy. Congruent surfaces in two useful coordinate systems — a system centered on the ellipsoid's axes of symmetry and a mirror-centered or `vertex' system with the surface tangent to the xy plane at the mirror's center — are presented. Expressions for the local slope and radii of curvature are derived from the result, and the first several terms of the Maclauren series expansion are provided about the mirror center.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 {mu}m was obtained at the spatial frequency of 4.3 {mu}m{sup -1} according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

43 PARTICLE ACCELERATORS↗

Communication system uses modulated laser beam

Electro-optical system is placed on a satellite to effect communications between two remote stations. The system employs an essentially passive, retrodirective, laser beam modulator-reflector.

Minott, P. O.↗

A proposed laser measurement system for determining surface contour

Electro-optical system can scan a large /100 ft./ antenna in 30 seconds. Comparison of the reflected signal with a reference signal from a Pockel-cell modulator driver yields a signal that can be correlated with the distance covered by the laser. A scanning arrangement then enables contour measurement.

Neubert, H. D.↗

Measurement of structure motion by means of a moving light sheet

The elaboration of an optical system which measures the displacement and velocity of large flexible space structures is reviewed. The motion-measuring system, comprised of a laser, optics, motorized mirror, two photodiodes and electronics, is designed to allow feedback for configuration control of flexible structures. A motor or scanner is employed to sweep the light sheet. The range of motion was shown to be 2 inches, and information was received at a rate of 30 Hz. The uncertainty in displacement measurement was better than +0.01 inch from a distance of 16 feet. The results are considered to be very good for two scanning light sheet systems. Higher sample rates and a more constant speed would improve the rotating mirror option, and the accuracy and range of the scanning mirror option could be upgraded as well. Both setups are shown to be viable noncontact measuring methods for the displacement and velocity of large space structures.

Tcheng, Ping↗

Atomic magnetometer with multiple spatial channels

An atomic magnetometer includes an atomic vapor cell, an optical system conformed to transmit pump radiation and probe radiation through the vapor cell, and an optical detection system arranged to receive and detect probe radiation after it exits the vapor cell. Improvements in the separation of spatial channels are achieved by using a a diffractive optical element arranged to divide at least the pump radiation into a plurality of separate diffracted beams that traverse the vapor cell.

47 OTHER INSTRUMENTATION↗

Precision optical angular position marker system for rotating machinery

An optical system is described which generates one or more markers of the angular shaft position of rotating machinery. The system consists of a light source, an optical cable, a machinery mounted lens assembly, a light detector, and a signal conditioner. Light reflected by targets on the rotor is converted to a digital output signal. The system is highly immune to extreme environments of vibration and temperature and achieved a 0.002 percent precision under operational test conditions.

Barranger, J. P.↗

Colossal Optical Anisotropy from Atomic-Scale Modulations

Materials with large birefringence (Δn, where n is the refractive index) are sought after for polarization control (e.g., in wave plates, polarizing beam splitters, etc.), nonlinear optics, micromanipulation, and as a platform for unconventional light–matter coupling, such as hyperbolic phonon polaritons. Layered 2D materials can feature some of the largest optical anisotropy; however, their use in most optical systems is limited because their optical axis is out of the plane of the layers and the layers are weakly attached. This work demonstrates that a bulk crystal with subtle periodic modulations in its structure—Sr 9/8 TiS 3 —is transparent and positive-uniaxial, with extraordinary index n e = 4.5 and ordinary index n o = 2.4 in the mid- to far-infrared. The excess Sr, compared to stoichiometric SrTiS 3 , results in the formation of TiS 6 trigonal-prismatic units that break the chains of face-sharing TiS 6 octahedra in SrTiS 3 into periodic blocks of five TiS 6 octahedral units. The additional electrons introduced by the excess Sr form highly oriented electron clouds, which selectively boost the extraordinary index n e and result in record birefringence (Δn > 2.1 with low loss). The connection between subtle structural modulations and large changes in refractive index suggests new categories of anisotropic materials and also tunable optical materials with large refractive-index modulation.

36 MATERIALS SCIENCE↗

First data and preliminary experimental results from a new Doppler backscattering system on the MAST-U spherical tokamak

Abstract A new Doppler backscattering (DBS) system, consisting of Q-band and V-band, has been installed and achieved its first data on the MAST-U spherical tokamak. The Q-band and V-band have separate microwave source systems, but share the same optical front-end components. The Q-band and V-band sources simultaneously generate eight (34, 36, 38, 40, 42, 44, 46 and 48 GHz) and seven (52.5, 55, 57.5, 60, 62.5, 65 and 67.5 GHz) fixed frequency probe beams, respectively. These frequencies provide a large range of radial positions from the low-field-side edge plasma to the core, and possibly to the high-field-side edge, depending on the plasma conditions. The quasi-optical system consists of a remotely-tunable polarizer, a focusing lens and a remotely-steerable mirror. By steering the mirror, the system provides remote control of the probed density fluctuation wavenumber, and allow the launch angle to match the magnetic field. The range of accessible turbulence wavenumbers (k θ ) is reasonably large with normalized wavenumberk θ ρ s ranging from <0.5 to 9. The first data acquired by this DBS system is validated by comparing with the data from the other DBS system on MAST-U (introduced in ref. [21]). An example of measuring the velocity profile spanning from the edge to the center in a high-density plasma is presented, indicating the robust capabilities of the integrated Q-band and V-band DBS systems.

Instruments & Instrumentation↗