Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Optical correlation with phase encoding and phase filtering

The image-encoding optical activity of a deformable-mirror device (DMD) has been investigated by means of numerical simulations in the Fourier plane. Simulation results are presented which reveal the sensitivity of phase-encoded/phase-filtered systems to noise, in-plane rotation, and magnification. The present simulations are based on phase-only modulation in the input and filter planes, and do not illustrate the 'phase-mostly' nature of the devices. A procedure to achieve a filter for a real system is proposed based on a simplistic model of a DMD pixel and preliminary device data.

Juday, Richard D.↗

SU-D-17A-02: Four-Dimensional CBCT Using Conventional CBCT Dataset and Iterative Subtraction Algorithm of a Lung Patient

Purpose: The Iterative Subtraction Algorithm (ISA) method generates retrospectively a pre-selected motion phase cone-beam CT image from the full motion cone-beam CT acquired at standard rotation speed. This work evaluates ISA method with real lung patient data. Methods: The goal of the ISA algorithm is to extract motion and no- motion components form the full reconstruction CBCT. The workflow consists of subtracting from the full CBCT all of the undesired motion phases and obtain a motion de-blurred single-phase CBCT image, followed by iteration of this subtraction process. ISA is realized as follows: 1) The projections are sorted to various phases, and from all phases, a full reconstruction is performed to generate an image CTM. 2) Generate forward projections of CTM at the desired phase projection angles, the subtraction of projection and the forward projection will reconstruct a CTSub1, which diminishes the desired phase component. 3) By adding back the CTSub1 to CTm, no motion CBCT, CTS1, can be computed. 4) CTS1 still contains residual motion component. 5) This residual motion component can be further reduced by iteration.The ISA 4DCBCT technique was implemented using Varian Trilogy accelerator OBI system. To evaluate the method, a lung patient CBCT dataset was used. The reconstruction algorithm is FDK. Results: The single phase CBCT reconstruction generated via ISA successfully isolates the desired motion phase from the full motion CBCT, effectively reducing motion blur. It also shows improved image quality, with reduced streak artifacts with respect to the reconstructions from unprocessed phase-sorted projections only. Conclusion: A CBCT motion de-blurring algorithm, ISA, has been developed and evaluated with lung patient data. The algorithm allows improved visualization of a single phase motion extracted from a standard CBCT dataset. This study has been supported by National Institute of Health through R01CA133539.

60 APPLIED LIFE SCIENCES↗

Parallel ptychographic reconstruction

Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.

97 MATHEMATICS AND COMPUTING↗

IFSAR Simulation Using the Shooting and Bouncing Ray Technique

Interferometric Synthetic Aperture Radar (IFSAR) is a technique that allows an automated way to carry out terrain mapping. IFSAR is carried out by first generating a SAR image pair from two antennas that are spatially separated. The phase difference between the SAR image pair is proportional to the topography. After registering the SAR images, the difference in phase in each pixel is extracted to generate an interferogram. Since the phase can only be measured within 2pi radians, phase unwrapping is carried out to extract the absolute phase for each pixel that will be proportional to the local height. While IFSAR algorithm is typically applied to measurement data, it is useful to develop an IFSAR simulator to develop a better understanding of the IFSAR technique. The IFSAR simulator can be used in choosing system parameters, experimenting with processing procedures and mission planning. In this paper we will present an IFSAR simulation methodology to simulate the interferogram based on the shooting and bouncing ray (SBR) technique. SBR is a standard ray-tracing technique used to simulate scattering from large, complex targets. SBR is carried out by shooting rays at the target or scene. At the exit point of each ray, a ray-tube integration is done to find its contribution to the total field. A fast algorithm has been developed for the SBR for simulating SAR images of complex targets. In the IFSAR simulation, we build upon the fast SAR simulation technique. Given the antenna pair configuration, radar system parameters and the geometrical description of the scene, we first simulate two SAR images from each antenna. After post processing the two SAR images, we generate an interferogram. Phase unwrapping is then performed on the interferogram to arrive at the desired terrain map. We will present results from the SBR-based IFSAR simulator. The results will include terrain map reconstruction of urban environments. The reconstruction will be compared to the ground truth to examine the fidelity of the simulation. We will also investigate the effect of multi-bounce scattering in urban environments on phase unwrapping and reconstruction.

Houshmand, Bijan↗

Diffraction and imaging study of imperfections of crystallized lysozyme with coherent X-rays

Phase-contrast X-ray diffraction imaging and high-angular-resolution diffraction combined with phase-contrast radiographic imaging were employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in the symmetric Laue case. The full-width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal was approximately 16.7 arcsec and imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <1 1 0> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Inclusions of impurities or formations of foreign particles in the central growth region are resolved in the images with high sensitivity to defects. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in X-ray diffraction images. The details of the observed defects and the significant change in the revealed microstructures with drying provide insight into the nature of imperfections, nucleation and growth, and the properties of protein crystals.

Muramidase/chemistry↗

On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation

Purpose: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors. Methods: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFs between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert. Results: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images. Conclusions: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Real-space imaging of periodic nanotextures in thin films via phasing of diffraction data

New properties and exotic quantum phenomena can form due to periodic nanotextures, including Moire patterns, ferroic domains, and topologically protected magnetization and polarization textures. Despite the availability of powerful tools to characterize the atomic crystal structure, the visualization of nanoscale strain-modulated structural motifs remains challenging. Here, we develop nondestructive real-space imaging of periodic lattice distortions in thin epitaxial films and report an emergent periodic nanotexture in a Mott insulator. Specifically, we combine iterative phase retrieval with unsupervised machine learning to invert the diffuse scattering pattern from conventional X-ray reciprocal-space maps into real-space images of crystalline displacements. Our imaging in PbTiO 3 /SrTiO 3 superlattices exhibiting checkerboard strain modulation substantiates published phase-field model calculations. Furthermore, the imaging of biaxially strained Mott insulator Ca 2 RuO 4 reveals a strain-induced nanotexture comprised of nanometer-thin metallic-structure wires separated by nanometer-thin Mott-insulating-structure walls, as confirmed by cryogenic scanning transmission electron microscopy (cryo-STEM). The nanotexture in Ca 2 RuO 4 film is induced by the metal-to-insulator transition and has not been reported in bulk crystals. We expect the phasing of diffuse X-ray scattering from thin crystalline films in combination with cryo-STEM to open a powerful avenue for discovering, visualizing, and quantifying the periodic strain-modulated structures in quantum materials.

Science & Technology - Other Topics↗

Investigation of physical image characteristics and phenomenon of edge enhancement by phase contrast using equipment typical for mammography

A technique called phase contrast mammography (PCM) has only recently been applied in clinical examination. In this application, PCM images are acquired at a 1.75x magnification using an x-ray tube for clinical use, and then reduced to the real size of the object by image processing. The images showed enhanced object edges; reportedly, this enhancement occurred because of the refraction of x rays through a cylindrical object. The authors measured the physical image characteristics of PCM to compare the image characteristics of PCM with those of conventional mammography. More specifically, they measured the object-edge-response characteristics and the noise characteristics in the spatial frequency domain. The results revealed that the edge-response characteristics of PCM outperformed those of conventional mammography. In addition, the characteristics changed with the object-placement conditions and the object shapes. The noise characteristics of PCM were better than those of conventional mammography. Subsequently, to verify why object edges were enhanced in PCM images, the authors simulated image profiles that would be obtained if the x rays were refracted and totally reflected by using not only a cylindrical substance but also a planar substance as the object. So, they confirmed that the object edges in PCM images were enhanced because x rays were refracted irrespective of the object shapes. Further, they found that the edge enhancements depended on the object shapes and positions. It was also proposed that the larger magnification than 1.75 in the commercialized system might be more suitable for PCM. Finally, the authors investigated phase-contrast effects to breast tissues by the simulation and demonstrated that PCM would be helpful in the diagnoses of mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global Images of Trapped Ring Current Ions During Main Phase of 17 March 2015 Geomagnetic Storm as Observed by TWINS

A unique view of the trapped particles in the inner magnetosphere provided by energetic neutral atom (ENA) imaging is used to observe the dynamics of the spatial structure and the pitch angle anisotropy on a global scale during the last 6 h of the main phase of a large geomagnetic storm (minimum SYM-H 230 nT) that began on 17 March 2015. Ion flux and pressure anisotropy obtained from Two Wide-angle Imaging Neutral-atom Spectrometers (TWINS) ENA images are shown. The ion flux shows two peaks, an inner one at approximately radii 34 RE in the dusk-to-midnight sector and an outer peak at radii 89 RE prior to midnight. The inner peak is relatively stationary during the entire period with some intensification during the final steep decline in SYM-H to its minimum. The outer peak shows the significant temporal variation brightening and dimming and finally disappearing at the end of the main phase. The pressure anisotropy shows the expected perpendicular pitch angles inside of L 6 but shows parallel pitch angles at greater L values. This is interpreted as consistent with pitch angle-dependent drift as modeled in the Tsy05 magnetic field and Comprehensive Inner Magnetosphere-Ionosphere simulations. The TWINS results are compared directly with Radiation Belt Storm Probes Ion Composition Experiment (RBSPICE)-A measurements. Using 15 min snapshots of flux and pressure anisotropy from TWINS along the path of RBSPICE-A during the 6 h focused upon in this study, the essential features displayed in the TWINS global images are supported.

Perez, J. D.↗

Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins

To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-resolution imaging of electrically induced oxygen vacancy migration and phase transformation in SrCoO 2.5-σ

Oxygen ion transport is the key issue in redox processes. Visualizing the process of oxygen ion migration with atomic resolution is highly desirable for designing novel devices such as oxidation catalysts, oxygen permeation membranes, and solid oxide fuel cells. We show the process of electrically induced oxygen migration and subsequent reconstructive structural transformation in a SrCoO 2.5-σ film by scanning transmission electron microscopy. We find that the extraction of oxygen from every second SrO layer occurs gradually under an electrical bias; beyond a critical voltage, the brownmillerite units collapse abruptly and evolve into a periodic nano-twined phase with a high c/a ratio and distorted tetrahedra. These results show that oxygen vacancy rows are not only natural oxygen diffusion channels, but also preferred sites for the induced oxygen vacancies. These direct experimental results of oxygen migration may provide a common mechanism for the electrically induced structural evolution of oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.

60 APPLIED LIFE SCIENCES↗

Deep Learning in Label-free Cell Classification

Label-free cell analysis is essential to personalized genomics, cancer diagnostics, and drug development as it avoids adverse effects of staining reagents on cellular viability and cell signaling. However, currently available label-free cell assays mostly rely only on a single feature and lack sufficient differentiation. Also, the sample size analyzed by these assays is limited due to their low throughput. Here, we integrate feature extraction and deep learning with high-throughput quantitative imaging enabled by photonic time stretch, achieving record high accuracy in label-free cell classification. Our system captures quantitative optical phase and intensity images and extracts multiple biophysical features of individual cells. These biophysical measurements form a hyperdimensional feature space in which supervised learning is performed for cell classification. We compare various learning algorithms including artificial neural network, support vector machine, logistic regression, and a novel deep learning pipeline, which adopts global optimization of receiver operating characteristics. As a validation of the enhanced sensitivity and specificity of our system, we show classification of white blood T-cells against colon cancer cells, as well as lipid accumulating algal strains for biofuel production. In conclusion, this system opens up a new path to data-driven phenotypic diagnosis and better understanding of the heterogeneous gene expressions in cells.

60 APPLIED LIFE SCIENCES↗

Pluto and Charon Seen with the New Horizons Spacecraft

After nearly a decade en route, New Horizons flew through the Pluto system in July 2015. The encounter hemisphere of Pluto shows ongoing surface geological activity centered on a vast basin (Sputnik Planum [SP]*) containing a thick layer of volatile ices with a crater retention age no greater than approximately 10 Ma. Surrounding terrains show active glacial flow, apparent transport and rotation of large buoyant water-ice crustal blocks, and pitting, likely by sublimation erosion and/or collapse. Also seen are constructional mounds with central depressions, and ridges with complex bladed textures. Pluto has ancient cratered terrains up to approximately 4 Ga old that are fractured and mantled, and perhaps eroded by glacial processes. Charon does not appear to be currently active, but experienced major tectonism and resurfacing nearly 4 Ga ago. Imaging spectrometer observations of Pluto reveal the encounter hemisphere to be dominated by volatile ices of N2, CO, and CH4, along with non-volatile components that include H2O and tholins. The most volatile of Pluto's ices (N2 and CO) are especially prevalent in the western half of Tombaugh Regio (TR), and the strikingly flat Sputnik Planum basin, which lies a few km below surrounding elevations. The high mobility of N2 and CO ices enables SP's surface to refresh itself sufficiently rapidly that no impact craters are seen there. This likely occurs through a combination of solid state convective overturning and sublimation/ condensation that produces regular patterns of pits and ridges on scales of 102 to 103 m. In many areas, CH4 appears to favor topographically high regions. Its propensity to condense on ridges could play a role in forming the bladed terrain seen in Tartarus Dorsa. H2O can be discerned across much of Cthulhu Regio, and also in a few isolated spots. In many regions, H2O ice is associated with reddish tholin coloration. Pluto's atmosphere was probed with the radio science experiment (REX) and the Alice UV spectrometer, as well as imaging at high phase angles. The surface pressure, due mostly to N2, is approximately 11 microbars. Extensive multiple haze layers are seen in the images. Alice has detected hydrocarbons in addition to CH4 in the atmosphere. Since both are inert, H2O ice and tholin could have similar geological behaviors on Pluto, possibly including aeolian transport or mobilization by volatile ice glaciation. While Pluto's H2O ice is sculpted and at least partially veiled by more volatile ices, Charon's heavily cratered H2O ice is exposed globally. H2O ice spectral bands characteristic of crystalline ice are seen everywhere on the encounter hemisphere. Charon's north polar region is strikingly red, possibly the result of the unique thermal environment of Charon's poles, which become exceptionally cold during the long, dark winters. Extremely cold regions on Charon' could cold trap gases expanding outward from Pluto as ices, and thereby subject them to rapid radiolytic processing. Charon also exhibits a weak NH3 absorption band over most or all of its surface, with small local concentrations. Detailed results of the radio science, small satellite, particles and plasma, and atmosphere investigations are in press.

Pluto↗

Quantitative Phase Fraction Detection in Organic Photovoltaic Materials through EELS Imaging

Organic photovoltaic materials have recently seen intense interest from the research community. Improvements in device performance are occurring at an impressive rate; however, visualization of the active layer phase separation still remains a challenge. Our paper outlines the application of two electron energy-loss spectroscopic (EELS) imaging techniques that can complement and enhance current phase detection techniques. Specifically, the bulk plasmon peak position, often used to produce contrast between phases in energy filtered transmission electron microscopy (EFTEM), is quantitatively mapped across a sample cross section. One complementary spectrum image capturing the carbon and sulfur core loss edges is compared with the plasmon peak map and found to agree quite well, indicating that carbon and sulfur density differences between the two phases also allows phase discrimination. Additionally, an analytical technique for determining absolute atomic areal density is used to produce an absolute carbon and sulfur areal density map. We also show how these maps may be re-interpreted as a phase ratio map, giving quantitative information about the purity of the phases within the junction.

14 SOLAR ENERGY↗

Applications of Phase-Based Motion Processing

Image pyramids provide useful information in determining structural response at low cost using commercially available cameras. The current effort applies previous work on the complex steerable pyramid to analyze and identify imperceptible linear motions in video. Instead of implicitly computing motion spectra through phase analysis of the complex steerable pyramid and magnifying the associated motions, instead present a visual technique and the necessary software to display the phase changes of high frequency signals within video. The present technique quickly identifies regions of largest motion within a video with a single phase visualization and without the artifacts of motion magnification, but requires use of the computationally intensive Fourier transform. While Riesz pyramids present an alternative to the computationally intensive complex steerable pyramid for motion magnification, the Riesz formulation contains significant noise, and motion magnification still presents large amounts of data that cannot be quickly assessed by the human eye. Thus, user-friendly software is presented for quickly identifying structural response through optical flow and phase visualization in both Python and MATLAB.

Branch, Nicholas A.↗

The Big Plunge at Venus: The DAVINCI Descent Phase

DAVINCI (Deep Atmosphere Venus Investigation of Noble gases, Chemistry, and Imaging) was selected as one of two new Discovery missions in summer of 2021 with the primary goals to study how the Venus atmosphere formed and changed over time. DAVINCI does this by making in situ measurements of the atmosphere, taking images below the cloud layer during the descent phase, and imaging the surface and clouds during two flyby science opportunities. The Descent Sphere is neither designed nor required to land on the surface so all critical science data must be taken and transmitted to a relay spacecraft prior to impact. This architecture drives the mission to a carefully-crafted concept of operations; deployments, instrument operations, and communications are choreographed to ensure the right data is gathered at the right altitude given the uncertainties in the trajectory and timeline. A complex flow of analyses and tests throughout development will validate the system’s ability to execute the mission goals. In the end DAVINCI will be ready for its one hour of descent time to meet its driving science goals.

DAVINCI↗

Two-dimensional lithium diffusion behavior and probable hybrid phase transformation kinetics in olivine lithium iron phosphate

Olivine lithium iron phosphate is a technologically important electrode material for lithium-ion batteries and a model system for studying electrochemically driven phase transformations. Despite extensive studies, many aspects of the phase transformation and lithium transport in this material are still not well understood. Here we combine operando hard X-ray spectroscopic imaging and phase-field modeling to elucidate the delithiation dynamics of single-crystal lithium iron phosphate microrods with long-axis along the [010] direction. Lithium diffusivity is found to be two-dimensional in microsized particles containing ~3%lithium-iron anti-site defects. Our study provides direct evidence for the previously predicted surface reaction-limited phase-boundary migration mechanism and the potential operation of a hybrid mode of phase growth, in which phase-boundary movement is controlled by surface reaction or lithium diffusion in different crystallographic directions. These findings uncover the rich phase-transformation behaviors in lithium iron phosphate and intercalation com-pounds in general and can help guide the design of better electrodes.

25 ENERGY STORAGE↗