Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Development of a large active area beam telescope based on the SiD microstrip sensor

A beam telescope as one of the most important and often requested test beam equipment provides particle tracking to test beam users. At the DESY II test beam facility, a new beam telescope called Lycorisbased on a microstrip sensor has been designed to address the user demands for momentum measurement in a 1 T solenoid magnet or large area tracking with limited space (3.5 cm between the potential user device and the magnet inner wall). Lycorisis designed to provide a high-precision resolution of at least ~10 µm along the bending direction, and a large active area of 10x10 cm 2 to cover at least 90% of the beam particles at energies of 1-6 GeV. The microstrip sensor was originally designed for the Silicon Detector (SiD) at the International Linear Collider (ILC), which adopted a hybrid-less design, i.e. a second metallization layer is used to route signals from strips to the bump-bonded ASIC, and from the ASIC to a wire-bond pad to the outside. This hybrid-less arrangement eliminates the need for a complex hybrid design, and its functioning is first-time tested in this project. The performance of the sensor modules was firstly tested in the lab then at the DESY II test beam facility in August/September 2018, and the results will be presented here. In addition, a summary will be given at the end with an overview of the ongoing test beam campaign of the Lycorisprototype in February 2019.

47 OTHER INSTRUMENTATION↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Inference of reaction rate parameters based on summary statistics from experiments

Here, we present the results of an application of Bayesian inference and maximum entropy methods for the estimation of the joint probability density for the Arrhenius rate para meters of the rate coefficient of the H 2 /O 2 -mechanism chain branching reaction H + O 2 → OH + O. Available published data is in the form of summary statistics in terms of nominal values and error bars of the rate coefficient of this reaction at a number of temperature values obtained from shock-tube experiments. Our approach relies on generating data, in this case OH concentration profiles, consistent with the given summary statistics, using Approximate Bayesian Computation methods and a Markov Chain Monte Carlo procedure. The approach permits the forward propagation of parametric uncertainty through the computational model in a manner that is consistent with the published statistics. A consensus joint posterior on the parameters is obtained by pooling the posterior parameter densities given each consistent data set. To expedite this process, we construct efficient surrogates for the OH concentration using a combination of Pad'e and polynomial approximants. These surrogate models adequately represent forward model observables and their dependence on input parameters and are computationally efficient to allow their use in the Bayesian inference procedure. We also utilize Gauss-Hermite quadrature with Gaussian proposal probability density functions for moment computation resulting in orders of magnitude speedup in data likelihood evaluation. Despite the strong non-linearity in the model, the consistent data sets all res ult in nearly Gaussian conditional parameter probability density functions. The technique also accounts for nuisance parameters in the form of Arrhenius parameters of other rate coefficients with prescribed uncertainty. The resulting pooled parameter probability density function is propagated through stoichiometric hydrogen-air auto-ignition computations to illustrate the need to account for correlation among the Arrhenius rate parameters of one reaction and across rate parameters of different reactions.

97 MATHEMATICS AND COMPUTING↗

Thermal impact of adhesive-mounted rooftop PV on underlying roof shingles

Adhesive mounting of residential rooftop photovoltaics (PV) is an alternative to traditional rack mounting that reduces installation costs. Adhesive mounting is fast, simple and reduces the need for skilled labor. In our novel design that further reduces the installation costs, a lightweight (glassless and frameless) PV module is directly adhered to a shingled roof using an adhesive tape, creating a <5 mm air gap between the PV back-panel and the roof shingle surface. Although the gap is sufficient for moisture and rainwater transport under the PV panel, potential heat buildup under the module may adversely impact the long-term durability of the shingles. Heat buildup may also increase the heat flux through the roof, resulting in an overall increase in building cooling loads. This study investigates the thermal behavior of the roof under an adhered PV system. Two identical test huts with dark shingle-covered roofs were located in the hot, desert climate of Albuquerque, NM. Adhesively-mounted lightweight PV modules were installed on the south-facing roof of one of the test huts (PV hut), with the other one serving as a reference hut. During the summer season, the asphalt roof shingles under the PV modules experienced a 13 °C reduction in daytime peak temperature compared with the exposed shingles. No evidence of heat buildup under the PV module was observed. It was also found that the temperature of shingles underneath the adhesive was up to 6 °C higher than for shingles underneath the gap space at the daily peak time. Thin but ventilated air gap between the PV back-panel and the roof shingles helped remove the heat, while the adhesive pads (patches) served as thermal bridges between the PV module and the roof. Daily peak heat flow through the attic ceiling was almost 49% lower in the PV hut compared to the reference hut. These results show no evidence of an adverse thermal impact of the adhesive-mounted PV system on the roofing materials, while demonstrating a potential for a notable reduction in space conditioning energy requirements.

14 SOLAR ENERGY↗

The contribution of heavy metals in cigarette smoke condensate to malignant transformation of breast epithelial cells and in vivo initiation of neoplasia through induction of a PI3K–AKT–NFκB cascade

Cigarette smoking is a crucial factor in the development and progression of multiple cancers including breast. Here, we report that repeated exposure to a fixed, low dose of cigarette smoke condensate (CSC) prepared from Indian cigarettes is capable of transforming normal breast epithelial cells, MCF-10A, and delineate the biochemical basis for cellular transformation. CSC transformed cells (MCF-10A-Tr) were capable of anchorage-independent growth, and their anchorage dependent growth and colony forming ability were higher compared to the non-transformed MCF-10A cells. Increased expression of biomarkers representative of oncogenic transformation (NRP-1, Nectin-4), and anti-apoptotic markers (PI3K, AKT, NFκB) were also noted in the MCF-10A-Tr cells. Short tandem repeat (STR) profiling of MCF-10A and MCF-10A-Tr cells revealed that transformed cells acquired allelic variation during transformation, and had become genetically distinct. MCF-10A-Tr cells formed solid tumors when implanted into the mammary fat pads of Balb/c mice. Data revealed that CSC contained approximately 1.011 μg Cd per cigarette equivalent, and Cd (0.0003 μg Cd/1 × 10{sup 7} cells) was also detected in the lysates from MCF-10A cells treated with 25 μg/mL CSC. In similar manner to CSC, CdCl{sub 2} treatment in MCF-10A cells caused anchorage independent colony growth, higher expression of oncogenic proteins and increased PI3K–AKT–NFκB protein expression. An increase in the expression of PI3K–AKT–NFκB was also noted in the mice xenografts. Interestingly, it was noted that CSC and CdCl{sub 2} treatment in MCF-10A cells increased ROS. Collectively, results suggest that heavy metals present in cigarettes of Indian origin may substantially contribute to tumorigenesis by inducing intercellular ROS accumulation and increased expression of PI3K, AKT and NFκB proteins. - Highlights: • Repeated exposure of CSC causes malignant transformation in MCF-10A. • MCF-10A-Tr cells showed a distinct STR profile and tumor inducing characteristics. • Increased expression of PI3K, AKT, and NFκB protein in MCF-10A-Tr and solid tumor. • Increased ROS and PI3K-AKT-NFκB proteins in smoke carcinogen exposed MCF-10A cells. • Cadmium may be a strong contributor to the transformation of MCF-10A cells.

60 APPLIED LIFE SCIENCES↗

Evaluation of the deposition, translocation and pathological response of brake dust with and without added chrysotile in comparison to crocidolite asbestos following short-term inhalation: Interim results

Chrysotile has been frequently used in the past in manufacturing brakes and continues to be used in brakes in many countries. This study was designed to provide an understanding of the biokinetics and potential toxicology following inhalation of brake dust following short term exposure in rats. The deposition, translocation and pathological response of brake dust derived from brake pads manufactured with chrysotile were evaluated in comparison to the amphibole, crocidolite asbestos. Rats were exposed by inhalation 6 h/day for 5 days to either brake dust obtained by sanding of brake-drums manufactured with chrysotile, a mixture of chrysotile and the brake dust or crocidolite asbestos. No significant pathological response was observed at any time point in either the brake dust or chrysotile/brake dust exposure groups. The long chrysotile fibers (> 20 μm) cleared quickly with T{sub 1/2} estimated as 30 and 33 days, respectively in the brake dust and the chrysotile/brake dust exposure groups. In contrast, the long crocidolite fibers had a T{sub 1/2} > 1000 days and initiated a rapid inflammatory response in the lung following exposure resulting in a 5-fold increase in fibrotic response within 91 days. These results provide support that brake dust derived from chrysotile containing brake drums would not initiate a pathological response in the lung following short term inhalation. - Highlights: • We evaluated brake dust w/wo added chrysotile in comparison to crocidolite asbestos. • Persistence, translocation, pathological response in the lung and pleural cavity. • Chrysotile cleared rapidly from the lung while the crocidolite asbestos persisted. • No significant pathology observed at any time point in the brake-dust groups. • Crocidolite produced pathological response - Wagner 4 interstitial fibrosis by 32d.

60 APPLIED LIFE SCIENCES↗

Evaluation of the fate and pathological response in the lung and pleura of brake dust alone and in combination with added chrysotile compared to crocidolite asbestos following short-term inhalation exposure

This study was designed to provide an understanding of the biokinetics and potential toxicology in the lung and pleura following inhalation of brake dust following short term exposure in rats. The deposition, translocation and pathological response of brake-dust derived from brake pads manufactured with chrysotile were evaluated in comparison to the amphibole, crocidolite asbestos. Rats were exposed by inhalation 6 h/day for 5 days to either brake-dust obtained by sanding of brake-drums manufactured with chrysotile, a mixture of chrysotile and the brake-dust or crocidolite asbestos. The chrysotile fibers were relatively biosoluble whereas the crocidolite asbestos fibers persisted through the life-time of the animal. This was reflected in the lung and the pleura where no significant pathological response was observed at any time point in the brake dust or chrysotile/brake dust exposure groups through 365 days post exposure. In contrast, crocidolite asbestos produced a rapid inflammatory response in the lung parenchyma and the pleura, inducing a significant increase in fibrotic response in both of these compartments. Crocidolite fibers were observed embedded in the diaphragm with activated mesothelial cells immediately after cessation of exposure. While no chrysotile fibers were found in the mediastinal lymph nodes, crocidolite fibers of up to 35 μm were observed. These results provide support that brake-dust derived from chrysotile containing brake drums would not initiate a pathological response in the lung or the pleural cavity following short term inhalation. - Highlights: • Evaluated brake dust w/wo added chrysotile in comparison to crocidolite asbestos. • Persistence, translocation, pathological response in the lung and pleural cavity. • Chrysotile cleared rapidly from the lung while the crocidolite asbestos persisted. • No significant pathology in lung or pleural cavity observed at any time point in the brake-dust groups. • Crocidolite quickly produced pathological response in the lung and pleural cavity.

60 APPLIED LIFE SCIENCES↗

Transcriptional profiling of rat white adipose tissue response to 2,3,7,8-tetrachlorodibenzo-ρ-dioxin

Polychlorinated dibenzodioxins are environmental contaminants commonly produced as a by-product of industrial processes. The most potent of these, 2,3,7,8-tetrachlorodibenzo-ρ-dioxin (TCDD), is highly lipophilic, leading to bioaccumulation. White adipose tissue (WAT) is a major site for energy storage, and is one of the organs in which TCDD accumulates. In laboratory animals, exposure to TCDD causes numerous metabolic abnormalities, including a wasting syndrome. We therefore investigated the molecular effects of TCDD exposure on WAT by profiling the transcriptomic response of WAT to 100 μg/kg of TCDD at 1 or 4 days in TCDD-sensitive Long-Evans (Turku/AB; L-E) rats. A comparative analysis was conducted simultaneously in identically treated TCDD-resistant Han/Wistar (Kuopio; H/W) rats one day after exposure to the same dose. We sought to identify transcriptomic changes coinciding with the onset of toxicity, while gaining additional insight into later responses. More transcriptional responses to TCDD were observed at 4 days than at 1 day post-exposure, suggesting WAT shows mostly secondary responses. Two classic AHR-regulated genes, Cyp1a1 and Nqo1, were significantly induced by TCDD in both strains, while several genes involved in the immune response, including Ms4a7 and F13a1 were altered in L-E rats alone. We compared genes affected by TCDD in rat WAT and human adipose cells, and observed little overlap. Interestingly, very few genes involved in lipid metabolism exhibited altered expression levels despite the pronounced lipid mobilization from peripheral fat pads by TCDD in L-E rats. Of these genes, the lipolysis-associated Lpin1 was induced slightly over 2-fold in L-E rat WAT on day 4. - Highlights: • Exposure to TCDD causes wasting syndrome in L-E rats but not in H/W rats. • We examined the transcriptome of TCDD-treated L-E and H/W rat white adipose tissue. • L-E WAT demonstrated altered abundance of several genes involved in immune response. • Few genes had altered abundance in both L-E rat WAT and human adipocytes (hMADS). • Pmepa1 was induced in both L-E WAT and differentiated hMADS cells.

60 APPLIED LIFE SCIENCES↗

Effect of diosgenin on metabolic dysfunction: Role of ERβ in the regulation of PPARγ

The present study was designed to investigate the effect of diosgenin (DSG) on metabolic dysfunction and to elucidate the possible molecular mechanisms. High fat (HF) diet-fed mice and 3T3-L1 preadipocytes was used to evaluate the effect of DSG. We showed that DSG attenuated metabolic dysfunction in HF diet-fed mice, as evidenced by reduction of blood glucose level and improvement of glucose and insulin intolerance. DSG ameliorated oxidative stress, reduced body weight, fat pads, and systematic lipid profiles and attenuated lipid accumulation. DSG inhibited 3T3-L1 adipocyte differentiation and reduced adipocyte size through regulating key factors. DSG inhibited PPARγ and its target gene expression both in differentiated 3T3-L1 adipocytes and fat tissues in HF diet-fed mice. Overexpression of PPARγ suppressed DSG-inhibited adipocyte differentiation. DSG significantly increased nuclear expression of ERβ. Inhibition of ERβ significantly suppressed DSG-exerted suppression of adipocyte differentiation and PPARγ expression. In response to DSG stimulation, ERβ bound with RXRα and dissociated RXRα from PPARγ, leading to the reduction of transcriptional activity of PPARγ. These data provide new insight into the mechanisms underlying the inhibitory effect of DSG on adipocyte differentiation and demonstrate that ERβ-exerted regulation of PPARγ expression and activity is critical for DSG-inhibited adipocyte differentiation. - Highlights: • Diosgenin (DSG) attenuated metabolic dysfunction in high fat (HF) diet-fed mice. • DSG reduced oxidative stress and lipid accumulation in HF diet-fed mice. • DSG inhibited 3T3-L1 adipocyte differentiation and reduced adipocyte size. • DSG induced the binding of ERβ with RXRα. • DSG-induced activation of ERβ dissociated RXRα from PPARγ and reduced PPARγ activity.

60 APPLIED LIFE SCIENCES↗

Carvedilol prevents functional deficits in peripheral nerve mitochondria of rats with oxaliplatin-evoked painful peripheral neuropathy

Oxaliplatin use as chemotherapeutic agent is frequently limited by cumulative neurotoxicity which may compromise quality of life. Reports relate this neurotoxic effect to oxidative stress and mitochondrial dysfunction in peripheral nerves and dorsal root ganglion (DRG). Carvedilol is an antihypertensive drug, has also been appreciated for its antioxidant and mitoprotective properties. Carvedilol co-treatment did not reduce the anti-tumor effects of oxaliplatin in human colon cancer cells (HT-29), but exhibited free radical scavenging activity against oxaliplatin-induced oxidative stress in neuronal cells (Neuro-2a). Hence, the present study was designed to investigate the effect of carvedilol in the experimental model of oxaliplatin-induced peripheral neuropathy (OIPN) in Sprague-Dawley rats. Oxaliplatin reduced the sensory nerve conduction velocity and produced the thermal and mechanical nociception. Carvedilol significantly (P < 0.001) attenuated these functional and sensorimotor deficits. It also counteracted oxidative/nitrosative stress by reducing the levels of nitrotyrosine and improving the mitochondrial superoxide dismutase expression in both sciatic nerve and DRG tissues. It improved the mitochondrial function and prevented the oxaliplatin-induced alteration in mitochondrial membrane potential in sciatic nerve thus prevented loss of intra epidermal nerve fiber density in the foot pads. Together the results prompt the use of carvedilol along with chemotherapy with oxaliplatin to prevent the peripheral neuropathy. - Graphical abstract: Schematic representation neuroprotective mechanisms of carvedilol in oxaliplatin-induced peripheral neuropathy. - Highlights: • Oxaliplatin-induced mitochondrial dysfunction causes neurotoxicity. • Mitochondrial dysfunction leads to bioenergetic and functional deficits. • Carvedilol alleviated oxaliplatin-induced behavioural and functional changes. • Targeting mitochondria with carvedilol attenuated neuropathic pain.

60 APPLIED LIFE SCIENCES↗

Recurrence analysis of friction based dry-couplant ultrasonic Lamb waves in plate-like structures

Here, in this study, the effect of friction on the generation of dry-coupled Lamb waves is experimentally investigated. Recurrence analysis is performed to analyze the complex behavior of friction based dry-coupled Lamb waves. In particular, the effect of the normal force, which is necessary for a stronger dry-coupled Lamb wave generation and the friction, on the transmission of mechanical energy and determinism characteristics of Lamb waves are investigated. The results verify that larger friction coefficient and friction force are crucial for generation and propagation of strong Lamb waves supporting the fact that the main mechanism to transfer mechanical energy using dry-couplant is friction. The sensitivity of Lamb waves to the friction coefficient, highlights the importance of designing specific pads with respect to condition of the surface. Besides, the results show that the normal force and friction coefficient can change the determinism characteristics behavior of multimode Lamb waves. Furthermore, it is shown that the determinism value is sensitive to the friction coefficient and normal force. A similar trend is observed in the determinism values and friction coefficient. In general, a smaller friction coefficient indicates smaller determinism value. Additionally, it is shown that a normal load can change the behavior of a system, as observed from recurrence plots, owing to changes in the Lamb waves trajectories in the phase-space domain. In addition, it is shown that recurrence plots enable the detection of mode transitions in multimode Lamb waves. Recurrence analysis is a complementary tool to frequency domain methods for accurate analysis of multimode Lamb waves behavior.

42 ENGINEERING↗

Additively manufactured and cast high-temperature aluminum alloys for electric vehicle brake rotor application

Electric vehicle brake rotors demand lightweight, high thermal conductivity materials with good resistance to wear, creep, salt corrosion, and thermal fade, all of which present challenges to the traditionally used cast iron. In this work, we investigated the braking performance of recently developed high-temperature aluminum alloys in both cast and 3D printed forms, that possess excellent microstructural and mechanical stability at elevated temperatures. Three aluminum alloys, Al-6Cu-Mn-Zr, Al-9Cu-Mn-Zr, and Al-Ce-Ni-Mn-Zr and a reference cast iron were tested on a sub-scale brake tester against a commercial brake pad material over a range of sliding speeds between 2 and 15 m/s. The performance of these alloys was evaluated for wear resistance, friction behavior, temperature elevation, and surface morphological change. Although all three candidate alloys had lower wear-resistance than cast iron, Al-Ce-Ni-Mn-Zr showed a significantly reduced wear rate in comparison to the Al-Cu-Mn-Zr alloys. Moreover, Al-Ce-Ni-Mn-Zr alloy had the most consistent friction behavior at all sliding speeds and good fade resistance, as the coefficient of friction did not dramatically decrease with temperature rise but stayed within a desirable range of 0.35–0.50 instead. The superior wear resistance and braking performance of the Al-Ce-Ni-Mn-Zr alloy were attributed to its higher hardness, and high temperature yield strength and creep resistance compared with the Al-Cu-Mn-Zr alloys. In conclusion, the results suggest that the braking performance of these aluminum alloys could be further enhanced by increasing the hardness and forming a more stable transfer layer on the sliding surface.

36 MATERIALS SCIENCE↗