Incident Management Preparedness and Coordination Toolkit

As with many professions, safety planners and first responders tend to be specialists in certain areas. To be truly useful, tools should be tailored to meet their specific needs. Thus, general software suites aimed at the professional geographic information system (GIS) community might not be the best solution for a first responder with little training in GIS terminology and techniques. On the other hand, commonly used web-based map viewers may not have the capability to be customized for the planning, response, and recovery (PR&R) mission. Data formats should be open and foster easy information flow among local, state, and federal partners. Tools should be free or low-cost to address real-world budget constraints at the local level. They also need to work both with and without a network connection to be robust. The Incident Management Preparedness and Coordination Toolkit (IMPACT) can satisfy many of these needs while working in harmony with established systems at the local, state, and federal levels. The IMPACT software framework, termed the Geospatial Integrated Problem Solving Environment (GIPSE), organizes tasks, tools, and resources for the end user. It uses the concept of software wizards to both customize and extend its functionality. On the Tasks panel are a number of buttons used to initiate various operations. Similar to macros, these task buttons launch scripts that utilize the full functionality of the underlying foundational components such as the SQL spatial database and ORNL-developed map editor. The user is presented with a series of instruction pages which are implemented with HTML for interactivity. On each page are links which initiate specific actions such as creating a map showing various features. Additional tasks may be quickly programmed and added to the panel. The end user can customize the graphical interface to faciltate its use during an emergency. One of the major components of IMPACT is the ORNL Geospatial Viewer (OGV). It is used to provide various map displays for the Tasks and Maps panels. Unlike typical maps however, the OGV display is highly interactive and can be customized, automated, and animated to meet the needs of the user. It is also a means to both import and export geospatial data from or to existing GIS systems. The built-in simulation capability can be used as the basis of table-top exercises.

Koch, Daniel B.↗

Instrument for assaying radiation

An instrument for assaying radiation includes a flat panel detector having a first side opposed to a second side. A collimated aperture covers at least a portion of the first side of the flat panel detector. At least one of a display screen or a radiation shield may cover at least a portion of the second side of the flat panel detector.

47 OTHER INSTRUMENTATION↗

Systems and methods for direct thermal receivers using near blackbody configurations

An aspect of the present disclosure is a receiver for receiving radiation from a heliostat array that includes at least one external panel configured to form an internal cavity and an open face. The open face is positioned substantially perpendicular to a longitudinal axis and forms an entrance to the internal cavity. The receiver also includes at least one internal panel positioned within the cavity and aligned substantially parallel to the longitudinal axis, and the at least one internal panel includes at least one channel configured to distribute a heat transfer medium.

47 OTHER INSTRUMENTATION↗

Sensing, interlocking solar module system and installation method

A solar module system is coupled directly to a fixed structure either individually or collectively as an array. Universal mounting brackets attached to the back of each solar panel module each connect to one or more other brackets of adjacent solar panels and/or to mounting feet that anchor to the fixed structure. Mounting brackets interlock with mounting brackets on adjacent solar modules and include a flexible snap coupling mechanism including a locking feature to selectively flexibly connect to and disconnect from other mounting brackets of adjacent solar panels.

14 SOLAR ENERGY↗

DOE Zero Energy Ready Homes

This article describes the U.S. Department of Energy's Zero Energy Ready Home Program and Housing Innovation Awards. Since 2013, builders around the country have certified over 1,170 homes to the high performance criteria of the DOE Zero Energy Ready Home program. Each year DOE recognizes the best innovators among this group with the DOE Housing Innovation Awards. 2017 winners will be announced at an awards event taking place at the Energy & Environmental Building Alliance (EEBA) high-performance home summit October 10-12, 2017, in Atlanta, Georgia. Twenty-five builders are expected to take home awards and grand award winners in each of the five competition categories will be revealed at the conference. Participating builders represent every climate zone in the country and DOE Zero Energy Ready labeled homes can be found in 34 states. Homes represent the full spectrum of the U.S. construction industry, from affordable to production to custom homes and from single-family detached to duplexes and up to five-story multifamily buildings as well as some retrofit projects have also met the criteria. Every DOE ZER certified home is certified through the ENERGY STAR Certified Homes (Version 3.0, revision 8) program and the U.S. Environmental Protection Agency’s Indoor airPLUS program. Each home must meet the hot water distribution requirements of the EPA’s WaterSense program and the insulation requirements of the 2012 International Energy Conservation Code. If the home has HVAC ducts, they must be installed within the conditioned space of the home. Appliances, exhaust fans, ceiling fans, and most of the lighting should be ENERGY STAR qualified. The DOE Zero Energy Ready Home program also requires homes to have solar electric panels installed or at a minimum to have the conduit and electrical panel space in place for future PV installation, if the home is in a location appropriate for solar power. Homes are constructed with enough energy efficiency built in so that, with a reasonable amount of solar PV panels (i.e., small enough to fit comfortably on the roof), the home could produce enough of its own power to equal the power it uses in a year.

U.S. Department of Energy Building Technologies Pr↗

CORROSION PERFORMANCE OF MIL-PRF-23377 PRIMER COATED ON LASER-INTERFERENCE STRUCTURED ALUMINUM ALLOY 2024

Laser-Interference Structuring (LIS) is a technique that was proposed to treat aluminum surfaces for improving primer adhesion. LIS may not require a series of chemical treatments, such as those used in chemical conversion coating (CCC) and sulfuric acid anodizing (SAA), which make the pre-treatment of Al panels simpler and quicker for primer painting. Previous test results indicated that LIS surface preparation enhances coating adhesion on Al 2024. To assess the effect of LIS on corrosion resistance of coatings, Al 2024 panels prepared by LIS, CCC and SAA were coated with MIL-PRF-23377 primers and exposed to salt spray environment according to ASTM B117. The exposure is currently in progress and the corrosion attack on the coated panels will be evaluated by the degree of blister formation and rust creepage according to ASTM standards.

Jun, Jiheon↗

Energy storage device and related methods

The present disclosure relates to energy storage devices having: a sealed container configured to house a plurality of energy storage devices and enable electrical communication via terminals of the sealed container and a vent located on a periphery of the sealed container. The vent generally comprises a vent panel; a countersink located adjacent the vent panel; at least one score located in the countersink; a buckling initiator at least partially located on the countersink, where the buckling initiator is configured to intersect with the at least one score; and a hinge portion attached to the vent panel, where the hinge portion is positioned opposite the buckling initiator.

Jarvis, Glenn W.↗

Integrated combustor nozzle for a segmented annular combustion system

The present disclosure is directed to an integrated combustor nozzle for a segmented annular combustion system. The integrated combustor nozzle includes an outer liner segment, an inner liner segment, and a fuel injection panel extending radially between the outer liner segment and the inner liner segment. The fuel injection panel includes a first side wall, a second side wall, and a plurality of premixing channels between the first and second side walls, each of the premixing channels having an outlet on one of the first and second side walls. The aft end of the fuel injection panel defines a turbine nozzle.

33 ADVANCED PROPULSION SYSTEMS↗

Cooling of integrated combustor nozzle of segmented annular combustion system

A segmented annular combustion system includes integrated combustor nozzles, each of which has a fuel injection panel disposed radially between an inner liner segment and an outer liner segment. The fuel injection panel includes an aft end portion, a first side wall, a second side wall, premixing channels defined between the first side wall and the side wall, and injection outlets defined along at least one of the first side wall and the second side wall. The aft end portion defines a turbine nozzle portion. An interior portion between the first side wall and the second side wall includes walls that extend between the first and second side walls, thereby partitioning the interior portion into discrete air cavities. The air cavities and the liner segments may be cooled by impingement inserts or panels.

42 ENGINEERING↗

Systems and methods for direct thermal receivers using near blackbody configurations

An aspect of the present disclosure is a receiver for receiving radiation from a heliostat array that includes at least one external panel configured to form an internal cavity and an open face. The open face is positioned substantially perpendicular to a longitudinal axis and forms an entrance to the internal cavity. The receiver also includes at least one internal panel positioned within the cavity and aligned substantially parallel to the longitudinal axis, and the at least one internal panel includes at least one channel configured to distribute a heat transfer medium.

14 SOLAR ENERGY↗

Segmented annular combustion system with axial fuel staging

A segmented annular combustion system includes an alternating arrangement of fuel nozzles and integrated combustor nozzles. The fuel nozzles deliver fuel to the primary combustion zones. The integrated combustor nozzles include an inner liner segment, an outer liner segment, and a fuel injection panel extending between the liner segments. The fuel injection panel includes injection outlets on one or both side walls to deliver a combustible mixture to the secondary combustion zones. Each fuel injection panel, which provides a boundary between adjacent primary and secondary combustion zones, includes an aft end that defines a turbine nozzle. The segmented annular combustion system is part of a gas turbine.

02 PETROLEUM↗

Cost Assessment of Building Envelope Retrofits

About 65% of US buildings were constructed before the Department of Energy established the Building Energy Codes Program in 1992; therefore, their envelopes are likely significant contributors to heating and cooling loads. Numerous techniques to improve the thermal, airtightness, and water tightness performance of existing envelopes have been explored; however, these tend to be lengthy and disruptive because most of the material assembly occurs at the job site. Overclad panels that are fabricated offsite and include most of the envelope components are a potential mechanism to reduce construction time and minimize disturbance to building occupants. These benefits have been demonstrated by European programs such as Energiesprong and MORE-CONNECT, as well as a few case studies in the US. Nevertheless, preliminary evaluations appear to indicate that overclad panels may be too costly to be implemented in the US. This paper summarizes cost estimates, strengths and weaknesses from several envelope retrofit techniques; assesses the feasibility of overclad panels in the US; and proposes methods, such as advanced manufacturing techniques, that could decrease the cost of building envelope retrofits.

Salonvaara, Mikael↗

Segmented annular combustion system

An annular combustion system includes a fuel nozzle, a panel fuel injector including a fuel plenum and at least one premixing channel therein, an inner liner including an inner band radially spaced from an outer band and an inner flow annulus formed therebetween, and an outer liner radially spaced from the inner liner and comprising an inner band radially spaced from an outer band and an outer flow annulus formed therebetween. The fuel nozzle is positioned radially between the inner liner and the outer liner, and the panel fuel injector extends radially between the inner liner and the outer liner. At least one of the inner flow passage and the outer flow passage is in fluid communication with at least one of a premix air plenum, a cooling air cavity and a cooling air plenum defined within the panel fuel injector.

42 ENGINEERING↗

Strategies for Working Remotely: Responding to Pandemic-Driven Change.

In response to the COVID-19 pandemic, the Exascale Computing Project’s (ECP) Interoperable Design of Extreme-scale Application Software (IDEAS) productivity team launched the panel series Strategies for Working Remotely to facilitate informal, cross-organizational dialog in the absence of face-to-face meetings. In a time of pandemic, organizations increasingly need to reach across perceived boundaries to learn from each other, so that we can move beyond stand-alone silos to more connected multidisciplinary and multiorganizational configurations. The present paper argues that the unplanned transition to remote work, overuse of electronic communication, and need to unlearn habits associated with an overreliance on face-to-face, created unique opportunities to learn from the situation and accelerate cross-institutional cooperation and collaboration through online community dialog facilitated by informal panel discussions. Recommendations for facilitating online panel discussions to foster cross-organizational dialog are provided by applying the Simulation Experience Design Method.

Raybourn, Elaine M.↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface

Cosmic rays are energetic nuclei and elementary particles that originate from stars and intergalactic events. The interaction of these particles with the upper atmosphere produces a wide range of secondary particles that reach the surface of the earth, of which muons are the most prominent. With enough energy, muons can travel up to a few kilometers beneath the surface of the earth before being stopped completely. The terrestrial muon flux profile and associated zenith angle can be utilized to determine geological characteristics of a location (e.g., rock overburden and density) without having to use conventional methods such as boreholes. This work uses a low-power plastic scintillator-based muon detection system as a prototype for this non-destructive geological assay methodology. Four custom designed 102 cm x 51 cm x 5 cm plastic scintillation panels are used to realize two orthogonal detection planes. Optical photons from each scintillation panel are read using OnSemi J-Series 4x4 silicon photomultiplier (SiPM) arrays in conjunction with preamplifiers. Simultaneous triggers between detectors from two planes indicate a coincidence event which is recorded using the QuarkNet data acquisition system (DAQ) from Fermi National Accelerator Laboratory. A custom detector holder was designed to securely mount the detection system and rotate the panels along the zenith to collect data at variable angles. In order to quantify the systematic uncertainties associated with the detector, such as energy depositions and angular resolution of the detector design, a Monte Carlo (MC) simulation using Geant4 is being developed. Cosmic ray flux prediction will be included in the project by adding the CORSIKA MC code to the simulation toolchain. Simulated and experimental data will drive the development and validation of a reconstruction algorithm that, upon completion, is expected to predict average overburden and rock density. Extended detector exposure to muons can be used as a means to understand changes in the surrounding environment like rock porosity. On the experimental front, muons will initially be measured at the surface, establishing the baseline flux. This is followed by recording the muon flux at variable depths and zenith angles, where the data will be used by the reconstruction algorithm to predict the overburden. The result will be benchmarked against geological surveys. The measured flux data will also be used to benchmark independent and established models. Successful proof-of-concept demonstration of this technology can open doors for long term non-invasive geological monitoring. The detector design, experimental methodology, and the benchmarking efforts are detailed in this work.

Gadey, Harish Reddy↗

Licensing, Regulations and Developing Guidance for Nuclear Technology Deployment for Embarking countries in Africa

The African region is witnessing an increased number of countries at different stages of implementing or considering the introduction of peaceful nuclear power programs to meet the demand of their rapidly growing economies as well as clean energy needs. Grid size, cost, licensing, and regulations will be some of the challenges to deploying larger power reactors. A key element of the regulatory framework will be the inclusion of nuclear security information and assurance that security is integrated into the license review process.As each country continue to implement and consider different reactor designs from several vendors, the significance of customer knowledge of licensing, Regulations, and guidance document to facilitate the deployment and operational needs for nuclear technology cannot be over-emphasized. This special session will bring together a selected panel of key stakeholders and policymakers from embarking countries in Africa to participate in a panel discussion to share their experience in the licensing, regulations, and development of guidance for power plant deployment. The session will also consider and identify potential gaps that may affect the licensing and regulatory applications for the future nuclear infrastructure. As well, the panel will promote regional networking and communication to increase capacities in readiness for the potential deployment of additional technology, such as Small Modular Reactors.

Dahunsi, Stephen↗

Application of Derrick Corporation's stack sizer technology for slimes reduction in 6 inch clean coal hydrocyclone circuits

The article discusses the successful introduction of Derrick Corporation's Stack Sizer technology for removing minus 200 mesh slimes from 6-inch coal hydrocyclone underflow prior to froth flotation or dewatering by screen bowl centrifuges. In 2006, the James River Coal Company selected the Stack Sizer fitted with Derrick 150 micron and 100 micron urethane screen panels for removal of the minus 100 mesh high ash clay fraction from the clean coal spiral product circuits. After this application proved successful, Derrick Corporation introduced new 75 micron urethane screen panels for use on the Stack Sizer. Evaluation of feed slurry to flotation cells and screen bowl centrifuges showed significant amounts of minus 75 micron that could potentially be removed by efficient screening technology. Removal of the minus 75 micron fraction was sought to reduce ash and moisture content of the final clean coal product. Full-scale lab tests confirmed that the Stack Sizer fitted with Derrick 75 micron urethane screen panels consistently reduced the minus 75 micron percentage in coal slurry from 6-inch clean coal hydrocyclone underflow that is approximately 15 to 20% solid by-weight and 30 to 60% minus 75 micron to a clean coal fraction that is approximately 13 to 16% minus 75 micron. As a result total ash is reduced from approximately 36 to 38% in the hydrocyclone underflow to 14 to 16% in the oversize product fraction form the Stack Sizers. 1 fig., 2 tabs., 5 photos.