Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Annular denuders for use in global climate and stratospheric measurements of acidic gases and particles

Measurements of acidic and basic gases that coexist with fine particle (less than 2.5 micron) may be useful for determining the impact of these species on global climate changes and determining species that influence stratospheric ozone levels. Annular denuders are well suited for this purpose. A new concentric annular denuder system, consisting of a three channel denuder, a Teflon coated cyclone preseparator, and a multistage filter pack was developed, evaluated, and shown to provide reliable atmospheric measurements of SO2, HNO2, HNO3, NH3, SO4(=), NH4(+), NO3(-), and H(+). For example, the precision of the annular denuder for the ambient measurements of HNO3 and nitrates at concentrations between 0.1 to 3 microgram/cu m was + or - 12 and 16 pct., respectively. The 120 x 25 mm three channel denuder is encased in a stainless steel sheath and has annular spaces that are 1 mm wide. This design was shown to have nearly identical capacity for removal of SO2 as conventional 210 x 25 mm single channel denuder configurations. The cyclone preseparator was designed and tested to have a D sub 50 cutoff diameter of 2.5 micron and minimal retention of HNO3.

Stevens, Robert K.↗

Vivianite oxidation is not photocatalyzed

Vivianite is a hydrous Fe2+ phosphate mineral found in anoxic environments that plays an integral role in P cycling and environmental biogeochemistry. Imbued in the vivianite literature dating as far back as 1918 is the notion that vivianite is light-sensitive and susceptible to rapid photooxidation induced entirely by solar light. However, despite an exhaustive search, to our knowledge this conventionally accepted assumption has never been directly tested, nor has the band gap ever been measured. Resolving this question of photochemical control of vivianite redox chemistry is important for performing and interpreting experiments involving vivianite reactivity with contaminants, and potentially iron and phosphate cycling in the photic zone of aquatic systems. The present study was specifically designed to add¬ress this question. Pure synthetic vivianite samples were irradiated in aqueous suspensions with a Xe lamp at conditions mimicking the solar spectrum and compared to dark controls. Particles stirred in anoxic suspensions for up to 66 days showed no detectable oxidation irrespective of light exposure, according to colorimetric Fe2+/Fe3+ assays, micro X-ray diffraction, and Raman spectroscopy. In contrast, the same experiment performed using air-equilibrated suspensions showed systematic oxidation of up to ~80% mol% Fe(II) at 66 days, but again with no detectable light exposure effect. To test for UV reactivity, further experiments on vivianite powders under air versus N2 atmosphere were performed using a Hg lamp with a longpass filter. In contrast to oxidation in air where no effect of light was detected, after 24 hrs irradiation anoxically, 0.78% Fe was oxidized compared to dark controls, and after 13 days only an additional 0.3% Fe was oxidized. The band gap of pure vivianite was measured by the Tauc method to be 3.5 eV. Contrary to previous reports, solar light has minimal impact on the oxidation of pure vivianite, insignificant in particular when compared to its relatively fast oxidation by oxygen exposure. As such, light does not need to be excluded when running typical vivianite laboratory experiments. Long-term storage of natural vivianite in museums or private collections should continue protective measures given that a possible photocatalytic role of impurities cannot yet be ruled out. Nonetheless, at all depths in natural aquatic systems it appears that the primary abiotic control on the reactivity and half-life of vivianite particles should be the dissolved oxygen concentration, not light exposure.

Vivianite, photochemistry, oxidation↗

Morphology of electrospun nanofibres of polyhydroxybutyrate

This research work focuses on process characteristics of polymer solutions, such as viscosity and electrical conductivity, as well as the parameters of electrospinning using poly-3-hydroxybutyrate modified by titanium dioxide nanoparticles, which have been optimized. Both physical-mechanical characteristics and photooxidation stability of materials have been improved. The structure of materials has been examined by means of X-ray diffraction, differential scanning calorimetry (DSC), IR-spectroscopy, and physical-mechanical testing. The fibrous materials obtained can find a wide application in medicine and filtration techniques as scaffolds for cell growth, filters for body fluids and gas-air media, and sorbents.

36 MATERIALS SCIENCE↗

First neutrino interactions observed with the MicroBooNE Liquid-Argon TPC detector

The MicroBooNE liquid-argon TPC detector started to take its first neutrino data from the Booster Neutrino Beam at the Fermi National Accelerator Laboratory on October 17, 2015. We have performed fullyautomated 3D reconstruction on these first data events using algorithms we have developed for the LArSoft software package, and we have developed a filter to distinguish neutrino interaction candidate events from the large number of events that contain activity originating mostly from cosmic rays. This is the first-time events from a large liquid argon TPC operating on/near the surface have been automatically reconstructed and selected for analysis. We describe the reconstruction and automated filtering procedure, and show displays of some of the first neutrino interactions observed with the detector using 1.86 × 10 18 protons on target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved calorimetric particle identification in NA62 using machine learning techniques

Measurement of the ultra-rare $K^+$ → $π$ +$ν$$\overline{ν}$ decay at the NA62 experiment at CERN requires high-performance particle identification to distinguish muons from pions. Calorimetric identification currently in use, based on a boosted decision tree algorithm, achieves a muon misidentification probability of 1.2×10 -5 for a pion identification efficiency of 75% in the momentum range of 15–40 GeV/c. In this work, calorimetric identification performance is improved by developing an algorithm based on a convolutional neural network classifier augmented by a filter. Muon misidentification probability is reduced by a factor of six with respect to the current value for a fixed pion-identification efficiency of 75%. Alternatively, pion identification efficiency is improved from 72% to 91% for a fixed muon misidentification probability of 10 -5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal and epithermal neutron fluence rate gradient measurements by PADC detectors in LINAC radiotherapy treatments-field

LINAC VARIAN 2100 is where energetic electrons produce Bremsstrahlung radiation, with energies above the nucleon binding energy (E≈5.5MeV). This radiation induce (γ,n) and (e,e’n) reactions mainly in the natural tungsten target material (its total photoneutron cross section is about 4000 mb in a energy range from 9-17 MeV). These reactions may occur also in other components of the system (e.g. multi leaf collimator). During radiation treatment the human body may receive an additional dose inside and outside the treated volume produced by the mentioned nuclear reactions. We measured the neutron density at the treatment table using nuclear track detectors (PADC-NTD). These covered by a boron-converter are employed, including a cadmium filter, to determine the ratio between two groups of neutron energy, i.e. thermal and epithermal. The PADC-NTD detectors were exposed to the radiation field at the iso-center during regular operation of the accelerator. Neutron are determined indirectly by the converting reaction {sup 10}B(n,α){sup 7}Li the emerging charged particle leave their kinetic energy in the PADC forming a latent nuclear track, enlarged by chemical etching (6N, NaOH, 70°C). Track density provides information on the neutron density through calibration coefficient (∼1.6 10{sup 4} neutrons /track) obtained by a californium source. We report the estimation of the thermal and epithermal neutron field and its gradient for photoneutrons produced in radiotherapy treatments with 18 MV linear accelerators. It was obsered that photoneutron production have higher rate at the iso-center.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plasma parameters in the near wake of the Space Shuttle

Results are presented from a Spherical Retarding Potential Analyzer and a spherical Langmuir Probe which were flown on the Spacelab-2 mission of the Space Shuttle Orbiter in August 1985. The probes were mounted in such a position that for certain Orbiter orientations, the wake edge formed by the starboard payload bay sill swept across the probes at a roll rate of once per orbit about an inertially stabilized pointing direction. Profiles of O(+) number density and electron number density across the wake edge showed that the charge particle number densities declined into the wake at a faster rate than that predicted by theoretical models. At angles of more than 10 deg into the wake from its geometric edge, two electron populations are found, with different mean random energies and electrical potentials. One of these populations is suggested to be the result of selective filtering of the high energy tails of the ambient ionospheric population, the other, a result of photoemission from the payload bay surfaces.

Raitt, W. J.↗

Polar wind ion bands after neutral sheet acceleration

The transport of polar wind protons from their ionospheric source through the magnetosphere is examined, using three-dimensional particle codes. The trajectory simulations demonstrate the escape of the high-latitude polar wind in the boundary layers during the quiescent magnetosphere, and, in contrast, its trapping in the nightside plasma sheet at times of high Kp. It is shown that the equatorial curvature of the magnetic field lines plays the role of an acceleration filter which yields, during active conditions, an 'ion band'-like precipitation of the polar wind protons characterized by a decrease of the downflowing ion energy with latitude, from several hundred down to a few electron volts. A further comparison between data and computations tends to indicate that, during disturbed times, the dayside originating polar wind provides an important contribution to the hundreds of electron volt downflowing protons in the nightside sector.

Delcourt, D. C.↗

THE ILLUMINATION AND GROWTH OF CRL 2688: AN ANALYSIS OF NEW AND ARCHIVAL HUBBLE SPACE TELESCOPE OBSERVATIONS

We present four-color images of CRL 2688 obtained in 2009 using the Wide-Field Camera 3 on Hubble Space Telescope. The F606W image is compared with archival images in very similar filters to monitor the proper motions of nebular structure. We find that the bright N-S lobes have expanded uniformly by 2.5% and that the ensemble of rings has translated radially by 0.''07 in 6.65 yr. The rings were ejected every 100 yr for {approx}4 millennia until the lobes formed 250 yr ago. Starlight scattered from the edges of the dark E-W dust lane is coincident with extant H{sub 2} images and leading tips of eight pairs of CO outflows. We interpret this as evidence that fingers lie within geometrically opposite cones of opening angles Almost-Equal-To 30 Degree-Sign like those in CRL618. By combining our results of the rings with {sup 12}CO absorption from the extended asymptotic giant branch (AGB) wind we ascertain that the rings were ejected at {approx}18 km s{sup -1} with very little variation and that the distance to CRL 2688, v{sub exp}/{theta}-dot{sub exp}, is 300-350 pc. Our 2009 imaging program included filters that span 0.6-1.6 {mu}m. We constructed a two-dimensional dust scattering model of stellar radiation through CRL 2688 that successfully reproduces the details of the nebular geometry, its integrated spectral energy distribution, and nearly all of its color variations. The model implies that the optical opacity of the lobes {approx}> 1, the dust particle density in the rings decreases as radius{sup -3}, and that the mass and momentum of the AGB winds and their rings have increased over time.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fiscal Year 2020 Filtration of Hanford Tank Waste 241-AP-105

Bench-scale filtration testing of 15 liters of 241-AP-105 supernatant was conducted using a Mott inline filter Model 6610 (media grade 5) backpulsed dead-end filter (BDEF) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. The as-received samples were diluted with raw water from the Hanford Site to assess the propensity for solids to form upon dilution and to assess the impact those solids have on filtration performance. The feed was split into two batches. The first batch was settled and decanted as planned in Tank Side Cesium Removal operations. The BDEF was used to filter this AP-105 feed at a targeted flux of 0.065 gpm/ft 2 and exhibited no measurable pressure increase during filtration. The second batch was fed to the BDEF with solids resuspended. This was also operated at the targeted flux of 0.065 gpm/ft 2 . In this case, the target pressure differential of 2 psid (resistance of 6.24 × 10 10 m -1 ) was reached in slightly more than 12 h. A backpulse restored the filter flux; however, the time to the next backpulse was slightly shorter. These tests indicate that after the addition of raw water, settle and decant effectively removed solids from the feed. It is not possible to assess the time required for these solids to settle based on the result from these tests. However, if sufficient time is allowed for the solids to settle, no measurable filter fouling was observed in current testing. In contrast, if insufficient time is allowed for solids to settle, filter fouling will occur relatively quickly and will likely require backpulses more frequently than every 12 hours (1.91 m 3 /m 2 volume filtered). Solids concentrated from backpulse solutions displayed large variability in composition with Al-silicates and mixed chromium-aluminum oxide phases. Amounts of Mg, Fe, and Ca were also found in the presence of Na and O. These solids could be grouped in three categories: (1) soluble Na-salts that formed large block-like particles but were made up of fibrous materials, (2) amorphous Al-phases, and (3) colloidal iron oxides with an average particle diameter of 4.2 µm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life in Extreme Environments Research #2

The goal of this project was to collect suspended particles and microbes for spectral analysis from deep water around hydrothermal vent study sites on the Juan de Fuca Ridge. To accomplish this, the McLane WTS 6-24-47 Sampler (McLane Research Laboratories, Falmouth, MA) was used. The WTS sampler is a programmable unit which is able to collect individual samples across twenty-four 47mm diameter filters at predetermined intervals and duration. Although only one successful deployment was needed, a maximum of three 3 deployments were possible (deployment opportunities were limited by the number of battery packs available). The initial behavior of the WTS and the ship's schedule both indicated that three deployments would be possible. However, it was revealed upon recovery after the first deployment that the WTS failed as it was preparing to collect its first sample.

Fisher, Charles R.↗

NASA Tech Briefs, September 2005

Topivs include: Diamond-Coated Carbon Nanotubes for Efficient Field Emission; Improved Anode Coatings for Direct Methanol Fuel Cells; Advanced Ablative Insulators and Methods of Making Them; PETIs as High-Temperature Resin-Transfer-Molding Materials; Stable Polyimides for Terrestrial and Space Uses; Low-Density, Aerogel-Filled Thermal-Insulation Tiles; High-Performance Polymers Having Low Melt Viscosities; Nonflammable, Hydrophobic Aerogel Composites for Insulation; Front-Side Microstrip Line Feeding a Raised Antenna Patch; Medium-Frequency Pseudonoise Georadar; Facilitating Navigation Through Large Archives; Program for Weibull Analysis of Fatigue Data; Comprehensive Micromechanics-Analysis Code - Version 4.0; Component-Based Visualization System; Software for Engineering Simulations of a Spacecraft; LabVIEW Interface for PCI-SpaceWire Interface Card; Path Following with Slip Compensation for a Mars Rover; International Space Station Electric Power System Performance Code-SPACE; Software for Automation of Real-Time Agents, Version 2; Software for Optimizing Plans Involving Interdependent Goals; Computing Gravitational Fields of Finite-Sized Bodies; Custom Sky-Image Mosaics from NASA's Information Power Grid; ANTLR Tree Grammar Generator and Extensions; Generic Kalman Filter Software; Alignment Stage for a Cryogenic Dilatometer; Rugged Iris Mechanism; Treatments To Produce Stabilized Aluminum Mirrors for Cryogenic Uses; Making AlNx Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam; Making Wide-IF SIS Mixers with Suspended Metal-Beam Leads; Sol-Gel Glass Holographic Light-Shaping Diffusers; Automated Counting of Particles To Quantify Cleanliness; Phase Correction for GPS Antenna with Nonunique Phase Center; Compact Infrasonic Windscreen; Broadband External-Cavity Diode Laser; High-Efficiency Solar Cells Using Photonic-Bandgap Materials; Generating Solid Models from Topographical Data; Computationally Lightweight Air-Traffic-Control Simulation; Spool Valve for Switching Air Flows Between Two Beds; Partial Model of Insulator/ Insulator Contact Charging; Asymmetric Electrostatic Radiation Shielding for Spacecraft; and Reusable Hybrid Propellant Modules for Outer-Space Transport.

Source record↗

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site R. Bhave (Oak Ridge National Laboratory. Oak Ridge, TN) and M. R. Poirier* (Savannah River National Laboratory, Aiken SC) Solid-liquid separation is the limiting step for many waste treatment processes at the Savannah River Site. SRNL researchers have identified the rotary microfilter as a technology to improve the rate of solid-liquid separation processes. SRNL is currently developing the rotary microfilter for radioactive service and plans to deploy the technology as part of the small column ion exchange process. The rotary microfilter can utilize any filter media that is available as a flat sheet. The current baseline membrane is a 0.5 micron (nominal) porous metal filter (Pall PMM050). Previous testing with tubular filters showed that filters composed of a ceramic membrane on top of a stainless steel support produce higher flux than filters composed only of porous metal. The authors are working to develop flat sheet filter media composed of a ceramic membrane and/or ceramic-metal composite on top of a porous stainless steel support that can be used with the rotary microfilter to substantially increase filter flux resulting in a more compact, energy efficient and cost-effective high level radioactive waste treatment system. Composite membranes with precisely controlled pore size distribution were fabricated on porous metal supports. High quality uniform porous metal (316SS) supports were fabricated to achieve high water permeability. Separative layers of several different materials such as ultrafine metal particles and ceramic oxides were used to fabricate composite membranes. The fabrication process involved several high temperature heat treatments followed by characterization of gas and liquid permeability measurements and membrane integrity analysis. The fabricated composite membrane samples were evaluated in a static test cell manufactured by SpinTek. The composite membranes were evaluated on several feed slurries: 1 wt. % strontium carbonate in deionized water, 1 wt. % monosodium titanate in simulated salt solution, and 1 wt. % simulated sludge in simulated salt solution and deionized water. Flux as a function of feed flow rate and transmembrane pressure was measured for each of the above described feed slurries. The authors will discuss the new membrane development efforts, waste slurry filtration performance evaluations and scale-up considerations.

Bhave, Ramesh R↗

H Ly-alpha transmittance of thin foils of C, Si/C, and Al/C for keV particle detectors

A class of instruments designed for remote sensing of space plasmas by measuring energetic neutral atoms (ENA) uses a thin foil as both a signal generator and a light shield. An ENA imager must look directly at the ENA source region, which is also usually an intense source of H Ly-alpha (1216 A) photons. It is desirable to minimize the energy threshold for ENA detectors, at the same time maximizing the blocking of H Ly-alpha. Optimizing filter design to meet these two contrary requirements has led us to measure the transmittance of thin C, Si/C, and Al/C foils at H Ly-alpha. Our results indicate that (1) transmittance of less than 0.0007 can be achieved with 7 micro-g/sq cm Si on 1.7 micro-g/sq cm C; (2) an Si/C composite foil with a thin carbon layer is more effective in blocking UV radiation while having the lowest energy threshold of all the foils measured; and (3) transmittance of Si/C foils of known Si and C thicknesses cannot be accurately predicted, but must be measured.

Drake, V. A.↗

Numerical methods for the weakly compressible Generalized Langevin Model in Eulerian reference frame

A well established approach for the computation of turbulent flow without resolving all turbulent flow scales is to solve a filtered or averaged set of equations, and to model non-resolved scales by closures derived from transported probability density functions (PDF) for velocity fluctuations. Effective numerical methods for PDF transport employ the equivalence between the Fokker–Planck equation for the PDF and a Generalized Langevin Model (GLM), and compute the PDF by transporting a set of sampling particles by GLM (Pope (1985) [1]). The natural representation of GLM is a system of stochastic differential equations in a Lagrangian reference frame, typically solved by particle methods. A representation in a Eulerian reference frame, however, has the potential to significantly reduce computational effort and to allow for the seamless integration into a Eulerian-frame numerical flow solver. GLM in a Eulerian frame (GLMEF) formally corresponds to the nonlinear fluctuating hydrodynamic equations derived by Nakamura and Yoshimori (2009) [12]. Unlike the more common Landau–Lifshitz Navier–Stokes (LLNS) equations these equations are derived from the underdamped Langevin equation and are not based on a local equilibrium assumption. Similarly to LLNS equations the numerical solution of GLMEF requires special considerations. In this paper we investigate different numerical approaches to solving GLMEF with respect to the correct representation of stochastic properties of the solution. We find that a discretely conservative staggered finite-difference scheme, adapted from a scheme originally proposed for turbulent incompressible flow, in conjunction with a strongly stable (for non-stochastic PDE) Runge–Kutta method performs better for GLMEF than schemes adopted from those proposed previously for the LLNS. We show that equilibrium stochastic fluctuations are correctly reproduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A photodiode-based neutral particle bolometer for characterizing charge-exchanged fast-ion behavior

A neutral particle bolometer (NPB) has been designed and implemented on Tri Alpha Energy's C-2 device in order to spatially and temporally resolve the charge-exchange losses of fast-ion populations originating from neutral beam injection into field-reversed configuration plasmas. This instrument employs a silicon photodiode as the detection device with an integrated tungsten filter coating to reduce sensitivity to light radiation. Here we discuss the technical aspects and calibration of the NPB, and report typical NPB measurement results of wall recycling effects on fast-ion losses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗