Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Novel Bio-based Polyaspartic Acid Copolymer: Synthesis, Structure and Performance of Degradation

A novel bio-based polyaspartic acid copolymer, as a multifunctional polymer was fabricated via in-site melting polymerization method using L-aspartic acid, γ-aminobutyric acid, L-phenylalanine and L-alanine as raw materials. The synthetic conditions were studied in detail, and the structure and degradation assays of these copolymers were investigated by FT-IR, XRD, weight loss rate, pH values, intrinsic viscosity and SEM. According to the results, all of the copolymers were found to have similar structure and excellent degradability. Additionally, the optimized copolymer C7 [L-aspartic acid (0.45 mol), γ-aminobutyric acid (0.35 mol), L-phenylalanine (0.05 mol) and L-alanine (0.15 mol)] exhibited the highest weight loss rate among all the copolymers. The weight loss rates on the 28th day in aqueous medium, phosphate buffered saline solution, 5.0 wt% trypsin solution and soil culture medium reached up to 44.74 wt%, 99.75 wt%, 90.67 wt% and 83.58 wt%, respectively. And the appropriate introduction of bio-based amino acids could control the degradation of polyaspartic acid distinctly. All of these results indicated that the bio-based polyaspartic acid copolymer could be used for reference as a good understanding of description the degradation of other environmentally friendly bio-based polymers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

Optimization of oncological {sup 18}F-FDG PET/CT imaging based on a multiparameter analysis

Purpose: This paper describes a method to achieve consistent clinical image quality in {sup 18}F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60–90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhanced mobility of dislocation network nodes and its effect on dislocation multiplication and strain hardening

Understanding plastic deformation of crystals in terms of the fundamental physics of dislocations has remained a grand challenge in materials science for decades. To overcome this, the Discrete Dislocation Dynamics (DDD) method has been developed, but its lack of atomistic resolution leaves open the possibility that certain key mechanisms may be overlooked. Here, by comparing large-scale Molecular Dynamics (MD) with DDD simulations performed under identical conditions we uncover significant discrepancies in the predicted strength and microstructure evolution in BCC crystals under high-strain rate conditions. These are traced to unexpected behaviors of dislocation network nodes forming at dislocation intersections, that can move in ways not previously anticipated as revealed by MD. Once these newfound freedoms of nodal motion are incorporated, DDD simulations begin to closely match plastic evolution observed in MD. This additional mechanism of motion whereby non-screw dislocations can change their glide plane profoundly affects fundamental processes of dislocation multiplication, recovery and storage that define strength of metals.

36 MATERIALS SCIENCE↗

Modeling fission product diffusion in TRISO fuel particles with BISON

Diffusion of fission products in intact TRISO particles depends on particle geometry, fission product source rates, time, temperature, and temperature-dependent diffusion coefficients. Simulating this diffusion process requires models for source rates and diffusion coefficients, plus computation of the temperature field if not prescribed. In addition, simulation quality depends on discretization of the geometry, appropriate time stepping, and the accuracy of the solution method. In this paper, we explore the simulation of fission product diffusion in TRISO fuel particles using the finite element method via the fuel performance code Bison. Recent material model development has occurred in Bison for each material present in tri-structural isotropic (TRISO) fuel particles: the buffer, inner pyrolytic carbon, silicon carbide, and outer pyrolytic carbon layers, as well as the fuel kernel. Also, new mesh generation and fission product release fraction capabilities have been added. Diffusion capabilities are shown to converge to the correct solution via formal verification tests. A large number of code benchmarking problems are also given, with good results, showing that Bison’s computed release fractions closely match those of other software tools. Finally, a significant validation effort is detailed in which fission product release, measured as part of the AGR-1 capsule experiments, is compared to Bison outputs. Bison outputs compare very well to the experimental data and to PARFUME results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrodeposited nickel coatings for exceptional corrosion mitigation in industrial grade molten chloride salts for concentrating solar power

Molten chloride salt eutectics are attractive candidates for use as thermal energy storage media and heat transfer fluids in generation-three concentrating solar thermal power (Gen3 CSP) plants. However, corrosion of alloys in molten chloride salts, especially at high temperatures, is an extremely challenging problem that studies focus on lower temperatures, shorter durations, or analytical grade, and high-purity, salts. To date, there has been no study on corrosion or corrosion mitigation in an industrial-grade salt at a high temperature such as 750 °C. To alleviate this knowledge gap, the study presents new multiscale fractal-textured Ni coatings on various alloy surfaces for effective corrosion mitigation at 750 °C in molten chloride salts. Using the electrodeposition method, durable double-layer textured coatings were formed on stainless steel alloys (SS316, SS310, and SS347) and In800H. The corrosion performance of the coatings is investigated in both analytical-grade purity and, for the first time, practically relevant industrial-grade chloride salts. Ni-coated ferrous alloys showed an exceptionally reduced corrosion rate in the range of 350–480 μm/y in analytical-grade salts, and between 450 and 490 μm/y in purified industrial-grade salts at 750 °C. Ni coatings on ferrous alloys reduced corrosion rates by as much as 70% compared to uncoated surfaces and were comparable to the expensive Ha230 alloy with a high Ni content. As a result, by the use of innovative fractal corrosion mitigation coatings, for the first time, low-cost structural alloys are rendered viable for use with industrial-grade chloride salts, which is profoundly beneficial in practical systems.

14 SOLAR ENERGY↗

Forecasting Battery Electrode Performance via Electrochemical Fluorescence Microscopy and Machine-Learning

Predicting lithium-ion battery performance is hindered by microscale electrode heterogeneities invisible to conventional diagnostics. Here, we combine electrochemical fluorescence microscopy (EFM), which maps electronic connectivity by visualizing an electrofluorophore reaction distribution, with a multitask ElasticNet regression to forecast discharge capacity from spatial heterogeneity. Analyzing 196 images from six pilot-scale LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathodes with varying carbon loadings, we extract 62 descriptors that capture morphology and texture. A compact five-feature model predicts capacity across eight discharge rates, achieving a per-target R 2 of up to 0.63 and an overall R 2 of 0.92, with a mean absolute percentage error of less than 2%. This performance rivals impedance-based approaches while avoiding their reliance on postformation data and incomplete electronic network information. Our facile and rapid, image-driven method may enable electrode quality control upstream of costly cell assembly to offer a transformative tool for data-driven battery research and manufacturing.

battery electrodes↗

Sliceable, Moldable, and Highly Conductive Electrolytes for All-Solid-State Batteries

All-solid-state batteries (ASSBs) require solid electrolytes with high ionic conductivity, stability, and deformability for optimal energy and power density. Here, we developed lithium-deficient lithium yttrium bromide (LYB) solid electrolytes, Li 3–x YBr 6–x (0 ≤ x ≤ 0.50), using a comelting method with controlled lithium deficiency. These electrolytes exhibit favorable mechanical properties such as high moldability and sliceability. The Li 2.65 YBr 5.65 composition has an ionic conductivity of 4.49 mS cm –1 at 25 °C and an activation energy of 0.28 eV. Compared to Li 3 YBr 6 , Li 2.65 YBr 5.65 demonstrates improved rate performance and cycling stability in ASSBs. High-resolution X-ray diffraction confirms the formation of the LYB phase with a C2/m space group. Structural analysis reveals increased cation disorder and larger polyhedral volumes for x > 0 in Li 3–x YBr 6–x , contributing to reduced Li + migration energy barriers. Bond valence site energy calculations and molecular dynamics simulations reveal enhanced 3D lithium-ion transport. NMR spectroscopy further highlights increased Li + dynamics and impurity elimination.

Poudel, Tej P. [Florida State Univ., Tallahassee, ↗

Correlating Microstructural Lithium Metal Growth with Electrolyte Salt Depletion in Lithium Batteries Using 7 Li MRI

Lithium dendrite growth in lithium ion and lithium rechargeable batteries is associated with severe safety concerns. To overcome these problems, a fundamental understanding of the growth mechanism of dendrites under working conditions is needed. In this work, in situ 7 Li magnetic resonance (MRI) is performed on both the electrolyte and lithium metal electrodes in symmetric lithium cells, allowing the behavior of the electrolyte concentration gradient to be studied and correlated with the type and rate of microstructure growth on the Li metal electrode. For this purpose, chemical shift (CS) imaging of the metal electrodes is a particularly sensitive diagnostic method, enabling a clear distinction to be made between different types of microstructural growth occurring at the electrode surface and the eventual dendrite growth between the electrodes. We report the CS imaging shows that mossy types of microstructure grow close to the surface of the anode from the beginning of charge in every cell studied, while dendritic growth is triggered much later. Simple metrics have been developed to interpret the MRI data sets and to compare results from a series of cells charged at different current densities. The results show that at high charge rates, there is a strong correlation between the onset time of dendrite growth and the local depletion of the electrolyte at the surface of the electrode observed both experimentally and predicted theoretical (via the Sand’s time model). A separate mechanism of dendrite growth is observed at low currents, which is not governed by salt depletion in the bulk liquid electrolyte. The MRI approach presented here allows the rate and nature of a process that occurs in the solid electrode to be correlated with the concentrations of components in the electrolyte.

25 ENERGY STORAGE↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Carbon-Binder Optimization for Lithium-Ion Battery Extreme Fast Charge

Battery performance is strongly correlated with electrode microstructure and weight loading of the electrode components. Among them are the carbon-black and binder additives that enhance effective conductivity and provide mechanical integrity. However, these both reduce effective ionic transport in the electrolyte phase and reduce energy density. Therefore, an optimal additive loading is required to maximize performance, especially for fast charging where ionic transport is essential. Such optimization analysis is however challenging due to the nanoscale imaging limitations that prevent characterizing this additive phase and thus quantifying its impact on performance. Herein, an additive-phase generation algorithm has been developed to remedy this limitation and identify percolation threshold used to define a minimal additive loading. Improved ionic transport coefficients from reducing additive loading has been then quantified through homogenization calculation, macroscale model fitting, and experimental symmetric cell measurement, with good agreement between the methods. Rate capability test demonstrates capacity improvement at fast charge at the beginning of life, from 37% to 55%, respectively for high and low additive loading during 6C CC charging, in agreement with macroscale model, and attributed to a combination of lower cathode impedance, reduced electrode tortuosity and cathode thickness.

carbon-binder additives↗

Dynamic scan control in STEM: spiral scans

Abstract Scanning transmission electron microscopy (STEM) has emerged as one of the foremost techniques to analyze materials at atomic resolution. However, two practical difficulties inherent to STEM imaging are: radiation damage imparted by the electron beam, which can potentially damage or otherwise modify the specimen and slow-scan image acquisition, which limits the ability to capture dynamic changes at high temporal resolution. Furthermore, due in part to scan flyback corrections, typical raster scan methods result in an uneven distribution of dose across the scanned area. A method to allow extremely fast scanning with a uniform residence time would enable imaging at low electron doses, ameliorating radiation damage and at the same time permitting image acquisition at higher frame-rates while maintaining atomic resolution. The practical complication is that rastering the STEM probe at higher speeds causes significant image distortions. Non-square scan patterns provide a solution to this dilemma and can be tailored for low dose imaging conditions. Here, we develop a method for imaging with alternative scan patterns and investigate their performance at very high scan speeds. A general analysis for spiral scanning is presented here for the following spiral scan functions: Archimedean, Fermat, and constant linear velocity spirals, which were tested for STEM imaging. The quality of spiral scan STEM images is generally comparable with STEM images from conventional raster scans, and the dose uniformity can be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Technology Research and Development (NTRD) Technical Monthly November FY18

Single crystals of U 3 Si 2 were grown at various crystal rotation and pull rates to establish the best parameters for growth of crystals with diameters ≥5 mm (Figure 1). Crystals were pulled from the melt using a modified Czochralski method. U 3 Si 2 single crystals will enable more fundamental property studies for this proposed high density fuel providing data to develop and inform physics-based fuel performance models. (D. Byler)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2.2.2.405 - Verdant/NREL Research Measurement Campaign

The marine renewable energy industry primarily uses thermoset composite materials for blades and other hydrodynamic components, which can have up to 50% reduction in strength when exposed to seawater and are not recyclable. Thermoplastic composite materials have been shown at a coupon-scale to have improved seawater saturated properties but have not been validated at full scale. The primary goal of the project is to demonstrate the structural properties of thermoplastic-fiberglass composite blades compared to epoxy-fiberglass composite blades in seawater at a tidal energy site on an operational turbine. Through this work, NREL manufactured, tested and deployed thermoplastic blades and a data acquisition system on Verdant Power's turbine TriFrame in the East River, NYC. The thermoplastic blades and DAQ were retrieved after a 6-month deployment with no signs of degradation and all cable connections, structural supports and strain gages had a 100% survival rate. The blades are currently undergoing post-deployment structural validation to compare their performance to traditional epoxy blades that were deployed for the same amount of time. This will increase confidence in thermoplastic materials and move it closer to commercial adoption, as well as increase confidence in the design of a DAQ and instrumentation method for a tidal turbine. However, due to an error in the DAQ software that was introduced after the DAQ and software were validated, there was no loads data collected during the deployment.

blade testing↗

Reactive transport modeling and characterization of concrete materials with fly ash replacement under carbonation attack - 15477

There currently lacks sufficient knowledge to accurately characterize structural, hydraulic, and chemical performance of cementitious materials that are required to contain and shield nuclear waste for thousands of years. There are a number of degradation methods that can affect the integrity of these materials over this time frame including carbonation which lowers the alkalinity of the material and can induce cracking in materials with steel reinforcement. The rate and extent of carbonation in these materials is impacted by the addition of fly ash and its composition which can vary depending on the fly ash source. To characterize the carbonation reaction, the changes in the microstructure and elemental distribution as a function of extent of carbonation and fly ash type were evaluated using scanning electron microscopy (SEM) coupled with energy dispersive x-ray spectroscopy (EDS). Micro-concretes were prepared with no fly ash (control case) and with fly ash of various calcium compositions. The progression of the carbonation front was observed in the backscattered electron images by the formation of calcium carbonate and depth was confirmed with a phenolphthalein pH indicator test. The migration and deposition of chemical species were observed in carbonated regions from EDS data and were explained based on the changes in material alkalinity and solubility determined from EPA Method 1313 (Liquid-solid partitioning (LSP) as a function of eluate pH). The changes in mass transport properties from carbonation were observed using EPA Method 1315 (Mass transfer rates in monolithic and compacted granular materials using semi-dynamic tank leaching procedures). The carbonation reaction in each material was simulated using LeachXS/ORCHESTRA, a reactive transport modeling tool, which provided further evidence of localized deposition and migration of chemical species due to changes in speciation and solubility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shielding and Activation Analyses for Beam Test Facility at SNS

The beam test facility (BTF) will be a copy of the accelerator front end of the Spallation Neutron Source (SNS) facility and will be used for test and development of new front-end equipment, for conducting research in accelerator physics (in a further build-out) for the SNS second target station moderator development (tests). The BTF is assembled and will be operating in the radio frequency (RF) on-site annex building. Negatively charged hydrogen ions (H{sup -}), generated at the ion source, will be accelerated to 2.5 MeV. The facility is capable of producing one-ms-long pulses at 60 Hz repetition rate with up to 50 mA peak current. This beam will be safely terminated in the beam stop. In order to support the BTF project from a radiation protection point of view, neutronics simulations and activation analyses were performed to develop shielding around the beam stop, evaluate dose rates in case of an accident and to evaluate the radionuclide inventory at the facility end-of-life for decommissioning. The challenge of the analyses was to consider low energy charges particles reaction physics to fit the calculations into our routine transport and activation methods as practiced for the much higher energy spallation environment. (authors)

43 PARTICLE ACCELERATORS↗

Stirred-Reactor Coupon Analysis: An International Round Robin Study

The objective of this task was to determine the precision of the SRCA technique when used to determine the dilute condition corrosion rate. To this end, an interlaboratory round robin study was conducted per the instructions in ASTM Practice E691 to measure the precision with which the SRCA test method can be conducted. Twelve independent labs from eleven different institutions each evaluated four glass compositions in three different conditions. The ASTM procedures recommend at least 6 labs participate in a round robin testing the same 3 materials in the same conditions to determine precision. In this case, 12 labs each performed 12 independent tests. This was only possible thanks to the multi-glass testing capability of the SRCA test. A total of 108 duplicate pairs were used to calculate the repeatability of the tests, with the same glass tested in the same vessel, producing as identical conditions as possible for the replicates. These test results were quite tightly clustered, with a median difference from the average value of the pair of only 2.9%. Based on the calculations outlined in ASTM E177-20 and a measured standard deviation of 4.74%, the intralaboratory repeatability limit (r) was calculated to be within 13.3% of the expected value with 95% confidence level. The reproducibility limit (R) of the test was examined using all 277 data points from the round robin. Because of the differences in dissolution rates due to pH variability and intrinsically for the 12 conditions tested, the reproducibility limits for each condition and overall were calculated from the percent relative residual value for each test. The SRCA test is expected to be reproducible within 64% of the expected value with a 95% confidence level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The utility of ultrasound guidance in transjugular liver biopsy: our experience

Purpose: To demonstrate the utility of ultrasound (US) guidance in improving the safety and efficacy of transjugular liver biopsy (TJLB) by analyzing all the TJLBs performed by us in the last 4 years. Materials and methods: Forty-seven patients who underwent TJLB in the last 4 years in our two centers were retrospectively analyzed. US guidance was used for all but for one patient during the two crucial steps of the procedure—for internal jugular vein (IJV) access and during the parenchymal biopsy. Biopsies were obtained under real-time sonographic guidance from the right lobe after confirming an adequate room for needle throw without breaching the liver capsule or any major hilar structures. Post-procedure complications, tissue yield, and histopathological adequacy of samples were analyzed. Results: Overall technical success rate was 100%. No major complications were found where ultrasound-assisted TJLB (uTJLB) was performed. One patient who underwent non-US guided TJLB had an event of a capsular breach and intra-peritoneal hemorrhage requiring coil embolization. Samples were of adequate dimension. Histopathological positivity was 100%. The overall complication rate for uTJLB was 4.7% which was due to minor complications in two patients. Conclusions: Addition of US unit to the angiographic suite is effortless and Interventional Radiologists being already skilled in US can easily implement this simple yet valuable modification to conventional TJLB procedures. Our experience on uTJLB further emphasizes the role of US guidance in improving the procedural success rate, safety profile, and efficacy in the histopathological outcome of TJLB in all patients irrespective of age and disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗