Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Final Report for Project DE-FC02-06ER25755 [Pmodels2]

In this report, we describe the research accomplished by the OSU team under the Pmodels2 project. The team has worked on various angles: designing high performance MPI implementations on modern networking technologies (Mellanox InfiniBand (including the new ConnectX2 architecture and Quad Data Rate), QLogic InfiniPath, the emerging 10GigE/iWARP and RDMA over Converged Enhanced Ethernet (RoCE) and Obsidian IB-WAN), studying MPI scalability issues for multi-thousand node clusters using XRC transport, scalable job start-up, dynamic process management support, efficient one-sided communication, protocol offloading and designing scalable collective communication libraries for emerging multi-core architectures. New designs conforming to the Argonne’s Nemesis interface have also been carried out. All of these above solutions have been integrated into the open-source MVAPICH/MVAPICH2 software. This software is currently being used by more than 2,100 organizations worldwide (in 71 countries). As of January ’14, more than 200,000 downloads have taken place from the OSU Web site. In addition, many InfiniBand vendors, server vendors, system integrators and Linux distributors have been incorporating MVAPICH/MVAPICH2 into their software stacks and distributing it. Several InfiniBand systems using MVAPICH/MVAPICH2 have obtained positions in the TOP500 ranking of supercomputers in the world. The latest November ’13 ranking include the following systems: 7th ranked Stampede system at TACC with 462,462 cores; 11th ranked Tsubame 2.5 system at Tokyo Institute of Technology with 74,358 cores; 16th ranked Pleiades system at NASA with 81,920 cores; Work on PGAS models has proceeded on multiple directions. The Scioto framework, which supports task-parallelism in one-sided and global-view parallel programming, has been extended to allow multi-processor tasks that are executed by processor groups. A quantum Monte Carlo application is being ported onto the extended Scioto framework. A public release of Global Trees (GT) has been made, along with the Global Chunks (GC) framework on which GT is built. The Global Chunks (GC) layer is also being used as the basis for the development of a higher level Global Graphs (GG) layer. The Global Graphs (GG) system will provide a global address space view of distributed graph data structures on distributed memory systems.

97 MATHEMATICS AND COMPUTING↗

Impact of High Performance Computing on the Detailed Simulation of Subsurface Flow and Contaminant Transport Using eSTOMP - 16341

The ability to model subsurface processes at the field-scale is essential to site closure and remedial action decisions. Field-scale models often require high-performance computing to meet the computational demands associated with complex systems, model calibration, and uncertainty quantification. eSTOMP, a parallel version of STOMP, is an analytical tool that meets the need for investigating coupled processes in the subsurface involving regional multi-fluid flow and biogeochemistry. The scalability of eSTOMP makes it ideal for simulating contaminant and geochemical reactive transport when long run times result from execution of a serial code. To demonstrate the impact of high-performance computation on subsurface analyses, the application of eSTOMP is presented for two sites. The first site involves uranium surface complexation within a highly dynamic, variably saturated flow field. The use of this model in conjunction with continued field monitoring is expected to provide a rigorous basis for developing operational strategies for field remediation and for defining defensible remediation endpoints. The second site involves the long-term dissolution of low-level radioactive glass emplaced within a near-surface repository. The waste form release rate is evaluated by modeling the basic physical and chemical processes that are known to control the waste form dissolution behavior, including pH and composition of the fluid contacting the glass. Simulations demonstrate that glass dissolution rates vary both in time and as a function of position within the disposal system, and that a 'leach rate' or radionuclide release rate parameter can only be estimated after identifying these impacts in a dynamic system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure and mechanism of the essential two-component signal-transduction system WalKR in Staphylococcus aureus

Most low GC Gram-positive bacteria possess an essential walKR two-component system (TCS) for signal transduction involved in regulating cell wall homoeostasis. Despite the well-established intracellular regulatory mechanism, the role of this TCS in extracellular signal recognition and factors that modulate the activity of this TCS remain largely unknown. Here we identify the extracellular receptor of the kinase ‘WalK’ (erWalK) as a key hub for bridging extracellular signal input and intracellular kinase activity modulation in Staphylococcus aureus . Characterization of the crystal structure of erWalK revealed a canonical Per-Arnt-Sim (PAS) domain for signal sensing. Single amino-acid mutation of potential signal-transduction residues resulted in severely impaired function of WalKR. A small molecule derived from structure-based virtual screening against erWalK is capable of selectively activating the walKR TCS. Lastly, the molecular level characterization of erWalK will not only facilitate exploration of natural signal(s) but also provide a template for rational design of erWalK inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Engine including hydraulically actuated valvetrain and method of valve overlap control

An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

42 ENGINEERING↗

Relationships between Vehicle Pricing and Features: Data Driven Analysis of the Chinese Vehicle Market

A full-scale understanding of the dynamics of the Chinese vehicle market can benefit stakeholders with respect to rational decision-making and effective long-term investment. This study attempts to discover the common vehicle pricing patterns in the Chinese market by quantifying statistical correlations among critical vehicle features from intrinsic powertrain systems to extrinsic market positioning. The data samples involve almost all passenger vehicle models sold in 2013 to 2019. After comparing multiple statistical methodologies, a log-transformation variant of the multinomial linear regression model was found to be the best one, and the goodness of fit shows that this model can offer stable estimates, which were validated using 2019 market data. The insights achieved are: (1) The price and major performance features of SUVs/crossovers are similar to those of sedans; (2) If all other explicit features remain the same, the price of a Japanese midsize sedan is 62% higher than that of a Chinese midsize sedan, and European midsize vehicles have the highest prices overall. (3) The incremental price of fuel consumption varies by vehicle class and fuel economy. For example, from 30 to 50 MPG, the vehicle price increases by $119 for a Chinese brand sedan vehicle, by $69 for a Chinese brand SUV.

33 ADVANCED PROPULSION SYSTEMS↗

Thermostat Interface and Usability: A Survey

This report investigates the history of thermostats to better understand the context and legacy regarding the development of this important tool, as well as thermostats' relationships to heating, cooling, and other environmental controls. We analyze the architecture, interfaces, and modes of interaction used by different types of thermostats. For over sixty years, home thermostats have translated occupants' temperature preferences into heating and cooling system operations. In this position of an intermediary, the millions of residential thermostats control almost half of household energy use, which corresponds to about 10percent of the nation's total energy use. Thermostats are currently undergoing rapid development in response to emerging technologies, new consumer and utility demands, and declining manufacturing costs. Energy-efficient homes require more careful balancing of comfort, energy consumption, and health. At the same time, new capabilities will be added to thermostats, including scheduling, control of humidity and ventilation, responsiveness to dynamic electricity prices, and the ability to join communication networks inside homes. Recent studies have found that as many as 50percent of residential programmable thermostats are in permanent"hold" status. Other evaluations found that homes with programmable thermostats consumed more energy than those relying on manual thermostats. Occupants find thermostats cryptic and baffling to operate because manufacturers often rely on obscure, and sometimes even contradictory, terms, symbols, procedures, and icons. It appears that many people are unable to fully exploit even the basic features in today's programmable thermostats, such as setting heating and cooling schedules. It is important that people can easily, reliably, and confidently operate thermostats in their homes so as to remain comfortable while minimizing energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system

Purpose: The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. Methods: They equipped a research Siemens Artiste linear accelerator (linac) with a 41 x 41 cm{sup 2} a-Si flat-panel detector underneath the treatment head. The in-line geometry allows kV (imaging) and MV (treatment) beams to share closely aligned beam axes. The kV source, usually mounted directly across from the flat-panel imager, was retracted toward the gantry by 13 cm to intentionally misalign kV and MV beams, resulting in a geometric separation of MV treatment field and kV image on the detector. Two consecutive images acquired within 140 ms (the first with MV-only and the second with kV and MV signal) were subtracted to generate a kV-only image. The images were then analyzed ''online'' with an automated threshold-based marker detection algorithm. They employed a 3D and a 4D phantom equipped with either a single radioopaque marker or three Calypso beacons to mimic respiratory motion. Measured room positions were either cross-referenced with a phantom voltage signal (single marker) or the Calypso system. The accuracy of the back-projection (from detected marker positions into room coordinates) was verified by a simulation study. Results: A phantom study has demonstrated that the imaging framework is capable of automatically detecting marker positions and sending this information to the tracking tool at an update rate of 7.14 Hz. The system latency is 86.9 {+-} 1.0 ms for single marker detection in the absence of MV radiation. In the presence of a circular MV field of 5 cm diameter, the latency is 87.1 {+-} 0.9 ms. The total RMS position detection accuracy is 0.20 mm (without MV radiation) and 0.23 mm (with MV). Conclusions: Based on the evaluated motion patterns and MV field size, the positional accuracy and system latency indicate that this system is suitable for real-time adaptive applications.

60 APPLIED LIFE SCIENCES↗

Verification and source-position error analysis of film reconstruction techniques used in the brachytherapy planning systems

A method was presented that employs standard linac QA tools to verify the accuracy of film reconstruction algorithms used in the brachytherapy planning system. Verification of reconstruction techniques is important as suggested in the ESTRO booklet 8: ''The institution should verify the full process of any reconstruction technique employed clinically.'' Error modeling was also performed to analyze seed-position errors. The ''isocentric beam checker'' device was used in this work. It has a two-dimensional array of steel balls embedded on its surface. The checker was placed on the simulator couch with its center ball coincident with the simulator isocenter, and one axis of its cross marks parallel to the axis of gantry rotation. The gantry of the simulator was rotated to make the checker behave like a three-dimensional array of balls. Three algorithms used in the ABACUS treatment planning system: orthogonal film, 2-films-with-variable-angle, and 3-films-with-variable-angle were tested. After exposing and digitizing the films, the position of each steel ball on the checker was reconstructed and compared to its true position, which can be accurately calculated. The results showed that the error is dependent on the object-isocenter distance, but not the magnification of the object. The averaged errors were less than 1 mm within the tolerance level defined by Roueet al. [''The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy,'' Radiother. Oncol. 78, 78-83 (2006)]. However, according to the error modeling, the theoretical error would be greater than 2 mm if the objects were located more than 20 cm away from the isocenter with a 0.5 deg. reading error of the gantry and collimator angles. Thus, in addition to carefully performing the QA of the gantry and collimator angle indicators, it is suggested that the patient, together with the applicators or seeds inside, should be placed close to the isocenter as much as possible. This method could be used to test the reconstruction techniques of any planning system, and the most suitable one can be chosen for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Periodic Boundary-Value Problems for Systems of Functional-Differential Equations

We obtain necessary and sufficient conditions for the existence of a unique solution to a periodic boundary-value problem for all systems of first-order functional-differential equations from a given family of systems. Families of systems of functional-differential equations are detrmined by the norms of positive functional operators of equations of the system. The verification of necessary and sufficient conditions of the existence of a unique periodic solution for all systems from a given family consists of the verification of positivity of a finite number of a real-valued functions defined on a finite-dimensional set.

97 MATHEMATICS AND COMPUTING↗

A Misalignment Tolerant Magnetic Coupler Design and Implementation for Wireless Charging of Unmanned Aerial Vehicles (UAVs)

Wireless power transfer technology is getting more attention these days as a part of expanded battery charging infrastructure and network at a wide range of power levels. Charging Unmanned aerial vehicles (UAVs) is one wireless charging application, and charging their batteries can be challenging because they have short flight times and are frequently charged. For wireless charging of UAVs, the misalignment performance of the magnetic coupler pads is critical because landing on a charging pad at a perfectly aligned position is difficult and can be time-consuming. Different coil shapes and system structures have been proposed in the literature to overcome this challenge. A new design with a high misalignment tolerance is needed; therefore, to fill this gap, a wireless power transfer system has been designed for a 250 W UAV battery charging system with a new magnetic coupler design. A 3D model of the proposed design was created, and finite element simulations were performed. To prove the proposed design, the magnetic coupler prototypes were developed, and experimental results are presented herein. The misalignment tolerance of the proposed system was observed for various rotational positions of the secondary coil, from 0° to 360°. The results demonstrate that DC–DC efficiency varies between 80% and 85% within full 360° rotation of the receiver coil. This result enables the proposed system to address the misalignment problem for wireless charging of UAVs.

UAVs↗

Information-theoretic treatment of tripartite systems and quantum channels

A Holevo measure is used to discuss how much information about a given positive operator valued measure (POVM) on system a is present in another system b, and how this influences the presence or absence of information about a different POVM on a in a third system c. The main goal is to extend information theorems for mutually unbiased bases or general bases to arbitrary POVMs, and especially to generalize ''all-or-nothing'' theorems about information located in tripartite systems to the case of partial information, in the form of quantitative inequalities. Some of the inequalities can be viewed as entropic uncertainty relations that apply in the presence of quantum side information, as in recent work by Berta et al. [Nature Physics 6, 659 (2010)]. All of the results also apply to quantum channels: For example, if E accurately transmits certain POVMs, the complementary channel F will necessarily be noisy for certain other POVMs. While the inequalities are valid for mixed states of tripartite systems, restricting to pure states leads to the basis invariance of the difference between the information about a contained in b and c.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deformable Mirror Materials Issue Assessment

It was a pleasure to speak with you and Dr. Olivier Guyon about your project to develop a coronagraph and in particular about materials science considerations in the development of the deformable mirror (DM) for the coronagraph. The coronagraph application will demand more of a DM than previous applications with regard to precision, and since the characterization and modeling tools are currently under development, you asked me to comment on materials issues that might impact the DM design and testing. I have not conducted research on this question, and my own research on modeling MEMS has not included DM systems. I am only in a position to discuss some general considerations that may help in developing a research plan for the DM system. As I understand it, the relevant points about the DM system are as follows. The DM surface needs to be positioned to less than 1 {angstrom} RMS of the desired shape, and be stable to 0.3 {angstrom} RMS for an hour. In the ultimate application in space the stability requirements may be greater. For example, the DM shape can be set using a bright star and then allow the coronagraph to be turned to a dim star to collect data for several hours, counting on the mirror shape to be stable. The DM is made of a polysilicon membrane coated with one or more metal layers for the reflective surface and actuated by 32x32 or 64x64 electrostatic actuators on the back side. The uncertainty in the position of any one actuator should be at the few-picometer level or less averaged over the 300-{micro}m region of the actuator. Currently, experiments are conducted that can characterize the surface shape to the 1 nm level, and it is anticipated that the experiments will be able to characterize the shape at the sub-Angstrom level but not in the immediate future. Regarding stability, under relatively large deformations (10's of nm), the DM mirror surface shows no hysteresis at the measurable nm level. Let me begin by saying that I am not aware of any article in the literature that directly assesses surface position stability at the sub-Angstrom level across 100's of microns of surface. Interferometry is typically used for precise metrology over areas this large, but not typically at the sub-Angstrom level. For the purpose of these comments, I assume that it will be possible to measure the precision of the mirror shape and stability at the requisite sub-Angstrom level at some point during the coronagraph development using interferometers or some other high-precision metrology technique. The hope is that the comments at this point may identify some potential issues that can be resolved early in the development to avoid costly surprises in the later stages.

36 MATERIALS SCIENCE↗

A Proof for the Unbiased Nature of Range-Doppler Measurements in Coarse-Resolution Dechirp-on-Receive Feedback Synthetic Aperture Radar Navigation

In feedback synthetic aperture radar (SAR) navigation, observables extracted from SAR range-Doppler images correct position and velocity errors accumulated within an associated navigation system. Unlike most other sensors, which produce measurements without input from a navigation system, SARs require a prior estimate of the radar’s position and velocity to adjust the radar’s matched filter during range-Doppler image formation. Consequently, it is possible for position and velocity errors within a navigation system to manifest as additional errors (biases) in the range-Doppler measurement observables. Prior work has not tackled this possibility in the context of feedback SAR navigation with a dechirp-on-receive radar. This paper offers a proof demonstrating that range-Doppler observables extracted from coarse-resolution vertical SAR images formed with a dechirp-on-receive radar may be safely modeled as unbiased measurements of the radar’s true position and velocity despite the presence of moderate navigation errors.

dechirp-on-receive↗

Measurement of the inelastic proton-proton cross section at $ \sqrt{s}=13 $ TeV

A measurement of the inelastic proton-proton cross section with the CMS detector at a center-of-mass energy of $\sqrt{s} =$ 13 TeV is presented. The analysis is based on events with energy deposits in the forward calorimeters, which cover pseudorapidities of -6.6 $< \eta <$ -3.0 and +3.0 $< \eta <$ +5.2. An inelastic cross section of 68.6 $\pm$ 0.5 (syst) $\pm$ 1.6 (lumi) mb is obtained for events with $M_\mathrm{X} >$ 4.1 GeV and/or $M_\mathrm{Y} >$ 13 GeV, where $M_\mathrm{X}$ and $M_\mathrm{Y}$ are the masses of the diffractive dissociation systems at negative and positive pseudorapidities, respectively. Furthermore, the results are compared with those from other experiments as well as to predictions from high-energy hadron-hadron interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ({sup 90}Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamics based on the principle of least abbreviated action: Entropy production in a network of coupled oscillators

We present some novel thermodynamic ideas based on the Maupertuis principle. By considering Hamiltonians written in terms of appropriate action-angle variables we show that thermal states can be characterized by the action variables and by their evolution in time when the system is nonintegrable. We propose dynamical definitions for the equilibrium temperature and entropy as well as an expression for the nonequilibrium entropy valid for isolated systems with many degrees of freedom. This entropy is shown to increase in the relaxation to equilibrium of macroscopic systems with short-range interactions, which constitutes a dynamical justification of the Second Law of Thermodynamics. Several examples are worked out to show that this formalism yields the right microcanonical (equilibrium) quantities. The relevance of this approach to nonequilibrium situations is illustrated with an application to a network of coupled oscillators (Kuramoto model). We provide an expression for the entropy production in this system finding that its positive value is directly related to dissipation at the steady state in attaining order through synchronization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Tumor Position and PTV Margins Using Image Guidance and Respiratory Gating

Purpose: To evaluate the margins currently used to generate the planning target volume for lung tumors and to determine whether image-guided patient setup or respiratory gating is more effective in reducing uncertainties in tumor position. Methods and Materials: Lung tumors in 7 patients were contoured on serial four-dimensional computed tomography (4DCT) data sets (4-8 4DCTs/patient; 50 total) obtained throughout the course of treatment. Simulations were performed to determine the tumor position when the patient was aligned using skin marks, image-guided setup based on vertebral bodies, fiducials implanted near the tumor, and the actual tumor volume under various scenarios of respiratory gating. Results: Because of the presence of setup uncertainties, the reduction in overall margin needed to completely encompass the tumor was observed to be larger for imaged-guided patient setup than for a simple respiratory-gated treatment. Without respiratory gating and image-guided patient setup, margins ranged from 0.9 cm to 3.1 cm to completely encompass the tumor. These were reduced to 0.7-1.7 cm when image-guided patient setup was simulated and further reduced with respiratory gating. Conclusions: Our results indicate that if respiratory motion management is used, it should be used in conjunction with image-guided patient setup in order to reduce the overall treatment margin effectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗