Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Convex Relaxations of Maximal Load Delivery for Multi-Contingency Analysis of Joint Electric Power and Natural Gas Transmission Networks

Recent increases in gas-fired power generation have engendered increased interdependencies between natural gas and power transmission systems. These interdependencies have amplified existing vulnerabilities in gas and power grids, where disruptions can require the curtailment of load in one or both systems. Although typically operated independently, coordination of these systems during severe disruptions can allow for targeted delivery to lifeline services, including gas delivery for residential heating and power delivery for critical facilities. To address the challenge of estimating maximum joint network capacities under such disruptions, we consider the task of determining feasible steady-state operating points for severely damaged systems while ensuring the maximal delivery of gas and power loads simultaneously, represented mathematically as the nonconvex joint Maximal Load Delivery (MLD) problem. To increase its tractability, we present a mixed-integer convex relaxation of the MLD problem. Then, to demonstrate the relaxation’s effectiveness in determining bounds on network capacities, exact and relaxed MLD formulations are compared across various multi-contingency scenarios on nine joint networks ranging in size from 25 to 1191 nodes. The relaxation-based methodology is observed to accurately and efficiently estimate the impacts of severe joint network disruptions, often converging to the relaxed MLD problem’s globally optimal solution within ten seconds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implementing multi-settlement decentralized electricity market design for transactive communities with imperfect communication

Recent advances in information and communication technologies and smart metering, provides strategic opportunities for ``prosumers" to reform their conventional energy practices towards more consumer-centric economies. From an operational perspective, managing power distribution networks is becoming more difficult with such active grid-edge systems providing limited to no visibility or control. Transactive Energy (TE) has been emerging as a key enabler towards effectively and efficiently integrating prosumers into competitive electricity markets. This work presents a transactive implementation of community-centric markets. A co-simulation framework is developed for evaluating the proposed market structure with high-fidelity models. Case studies on the IEEE-123 node test system demonstrate that community-centric transactive markets can enable communities of prosumers to operate collaboratively as grid-edge systems. The potential benefits of implementing community-centric TE systems are also illustrated.

Mukherjee, Monish↗

Grid Interconnection and Performance Testing Procedures for Vehicle-To-Grid (V2G) Power Electronics: Preprint

Bidirectional power electronics can add vehicle-to-grid (V2G) capability in a plug-in vehicle, which then allows the vehicle to operate as a distributed resource (DR). The uniqueness of the battery-based V2G power electronics requires a test procedure that will not only maintain IEEE interconnection standards, but can also evaluate the electrical performance of the vehicle working as a DR. Theobjective of this paper is to discuss a recently published NREL technical report that provides interim test procedures for V2G vehicles for their integration into the electrical distribution systems and for their performance in terms of continuous output power, efficiency, and losses. Additionally, some other test procedures are discussed that are applicable to a V2G vehicle that desires toprovide power reserve functions. A few sample test results are provided based on testing of prototype V2G vehicles at NREL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting

Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economic dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.

17 WIND ENERGY↗

Emergency Asset Positioning for Resilient Transmission Grid Operation

In this paper we study a problem of hurricane emergency preparedness via placement of emergency generation assets prior to its strike. We present a two-stage stochastic model for choosing locations and quantities of emergency storage to help support the power grid through a hurricane event. The expectation of losses in our two-stage model is estimated using the sample average approximation. We construct damage scenarios for sample average approximation using WIND Toolkit meteorological data and fragility curves of various electric grid components. We demonstrate the efficacy of our two-stage planning model by simulating operations during Hurricane Dolly on the 2000-bus transmission test system. Our model, coupled with our scenario selection strategy, is effective at mitigating loss of load when compared to a model without emergency generation assets placed prior to an extreme event.

emergency preparedness↗

Power Plant Cycling Costs

This report provides a detailed review of the most up to date data available on power plant cycling costs. The primary objective of this report is to increase awareness of power plant cycling cost, the use of these costs in renewable integration studies and to stimulate debate between policymakers, system dispatchers, plant personnel and power utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

Multi-objective Decisions on Integrated Energy Systems Planning and Operation for Industrial Combined Heat and Power Supply

Unlike the power sector—which can transmit electricity over long distances via established grids—the industrial sector poses a unique challenge due to its geographically concentrated large-scale heat processes. Enhancing energy security in such industrial parks provides a dual benefit: reduced exposure to volatile fossil fuel prices and improved economic viability, largely driven by economies of scale in energy supply and distribution. This study presents a comprehensive technoeconomic analysis of a nuclear energy hub, employing a mechanism-focused approach to evaluate uncertainties in operational strategies and capacity optimization. Load profiles from three major energy intesive industries—chemical, refinery, and steelmaking—are examined, each presenting unique challenges and opportunities for nuclear energy integration. We adopt a multi-objective optimization framework, converting multiple objectives into a single objective function through the e-constraint method. The findings highlight clear trade-offs between system conditions and varying levels of energy independence. Overall, this analysis is granular enough to address industry-specific concerns yet sufficiently generalizable to provide actionable insights into the feasibility of nuclear-based clean heat solutions for the industrial sector.

25 - ENERGY STORAGE↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Site Energy Management System Platform Development

A site energy management system is a critical component of future high-power EV charging hubs. It monitors and supervises all inter-hub operations, coordinates grid interactions, and implements energy management strategies and load-sharing controls at various levels and time scales. This report provides a comprehensive high-level overview and guidelines on the essential elements of such energy management systems. These elements primarily focus on the core functions, architecture, and monitoring aspects of site energy management. The core functions define the grid services and operational objectives that a charging hub is expected to provide and achieve. The architectural section investigates the coordination between hub assets, different control schemes, and their potential benefits and drawbacks. Lastly, the report discusses the needs, types, and functionalities of a monitoring and visualization system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Durability tests of a five-centimeter diameter ion thruster system.

A modified Hughes SIT-5 system is being tested for durability at the Lewis Research Center. As of Oct. 1, 1972, the thruster subsystem has logged over 8000 hours of operation. The initial 2023 hours were run with a translating screen thrust vector grid. The thruster is currently operating with an electrostatic type vector grid. Profiles and maps taken at widely separated intervals show that performance and operating characteristics have remained essentially constant. Overall efficiency is about 32 per cent and power to thrust ratio is 170 watts per millipound at a specific impulse of 2500 seconds. Telescopic examination of the vector grid shows some sputtering erosion due to charge exchange and direct impingement ions. An independent test of the propellant storage and cathode-isolator-vaporizer subsystem has demonstrated good reliability under simulated thruster operating conditions.

Nakanishi, S.↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Enabling Resiliency Operations across Multiple Microgrids with Grid Friendly Appliance Controllers

Changes in economic, technological, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, as well as integrating electricity generation with other municipal functions. When grid connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via a collection of microgrids. To achieve the highest level of resiliency, it may be necessary to conduct switching operations to interconnect individual microgrids. While the interconnection of multiple microgrids can increase the resiliency of the system, the associated switching operations can cause large transients in low inertia microgrids. The combination of low system inertia and IEEE 1547 and 1547a-compliant inverters can prevent multiple microgrids from being interconnected during extreme weather events. This study will present a method of using end-use loads equipped with Grid Friendly™ Appliance controllers to facilitate the switching operations between multiple microgrids; operations that are necessary for optimal operations when islanded for resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and Control of Electric Power Systems

The analysis and optimization needs for planning and operation of the electric power system are challenging due to the scale and the form of model representations. The connected network spans the continent and the mathematical models are inherently nonlinear. Traditionally, computational limits have necessitated the use of very simplified models for grid analysis, and this has resulted in either less secure operation, or less efficient operation, or both. The research conducted in this project advances techniques for power system optimization problems that will enhance reliable and efficient operation. The results of this work appear in numerous publications and address different application problems include optimal power flow (OPF), unit commitment, demand response, reliability margins, planning, transmission expansion, as well as general tools and algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗