Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

The Pandora multi-algorithm approach to automated pattern recognition of cosmic-ray muon and neutrino events in the MicroBooNE detector

The development and operation of Liquid-Argon Time-Projection Chambers for neutrino physics has created a need for new approaches to pattern recognition in order to fully exploit the imaging capabilities offered by this technology. Whereas the human brain can excel at identifying features in the recorded events, it is a significant challenge to develop an automated, algorithmic solution. The Pandora Software Development Kit provides functionality to aid the design and implementation of pattern-recognition algorithms. It promotes the use of a multi-algorithm approach to pattern recognition, in which individual algorithms each address a specific task in a particular topology. Many tens of algorithms then carefully build up a picture of the event and, together, provide a robust automated pattern-recognition solution. This paper describes details of the chain of over one hundred Pandora algorithms and tools used to reconstruct cosmic-ray muon and neutrino events in the MicroBooNE detector. Metrics that assess the current pattern-recognition performance are presented for simulated MicroBooNE events, using a selection of final-state event topologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Addressing uncertainty in genome-scale metabolic model reconstruction and analysis

The reconstruction and analysis of genome-scale metabolic models constitutes a powerful systems biology approach, with applications ranging from basic understanding of genotype-phenotype mapping to solving biomedical and environmental problems. However, the biological insight obtained from these models is limited by multiple heterogeneous sources of uncertainty, which are often difficult to quantify. Here we review the major sources of uncertainty and survey existing approaches developed for representing and addressing them. A unified formal characterization of these uncertainties through probabilistic approaches and ensemble modeling will facilitate convergence towards consistent reconstruction pipelines, improved data integration algorithms, and more accurate assessment of predictive capacity.

59 BASIC BIOLOGICAL SCIENCES↗

Reconstruction and Selection of Neutrino Interactions in MicroBooNE using Deep Convolutional Neural Networks

In this document, we describe a new reconstruction workflow developed for the MicroBooNE experiment. It features the use of Deep Convolutional Neural Networks trained to recognize key structures within the data sufficient for the 3D reconstruction of neutrino interactions within the detector. As a test of the reconstruction utility, the products of the reconstruction workflow are used to select inclusive charged-current (CC) $\nu_e$ and $\nu_\mu$ interactions in both simulated and real MicroBooNE data. In simulation, our $\nu_e$ and $\nu_\mu$ selections achieve an efficiency of 57% and 68\%, respectively, with a purity of 91% and 96%, respectively. We find that these selections are competitive with the inclusive selections used for the most recent MicroBooNE LEE searches. In particular, the CC-$\nu_e$ inclusive selection efficiency improves by over 20% while also improving sample purity. As a first step in quantifying potential bias, the data and Monte Carlo expectati ons are compared for both selections using the MicroBooNE open data. Within statistical and systematic uncertainties, both the electron and muon CC-inclusive event samples agree. A comparison of the real data events chosen by our work and another reconstruction framework shows that the two analyses each identify a sizeable fraction of events the other does not. This suggests that future analyses integrating the strengths of each could lead to combined gains. This work demonstrates, for the first time on real LArTPC data, state-of-the-art neutrino interaction reconstruction centered around deep learning algorithms.

43 PARTICLE ACCELERATORS↗

Novel experimental probes of QCD in SIDIS and e + e - annihilation (Final Technical Report)

The research addressed with this award seeks to advance our understanding of the structure and dynamics underlying the properties of visible matter. In our current understanding the nucleons (protons and neutrons) are not fundamental but are comprised of quarks and gluons, which are collectively called partons. A static quark picture fails to explain the properties of the nucleons, such as their mass and intrinsic spin, which are thought to emerge dynamically from the quark-gluon interactions via the strong force. In this work, novel observables employing correlations of particles produced in the scattering of high energy electrons off protons at the CLAS12 experiment at Jefferson Lab were analyzed to probe quark-gluon interactions. The ultimate goal of this line of inquiry is to be able to describe the properties of protons and neutrons from first principles, similar to how studying the hydrogen atom has led to the formulation of the theory of Quantum Electrodynamics. Because quarks cannot be observed directly but only as part of more complex composite particles, a smaller, complimentary part of this work was the analysis of particle production in electron-positron annihilation at the Belle II experiment to understand the production of particles from initial quarks. This takes advantage of the fact that in e + e - annihilation the initial quark dynamics is known, unlike in the scattering of nucleons. Several new applications using Machine Learning algorithms for event tagging and reconstruction to support this program were developed as part of this award. In addition, we had a significant role in the development of the physics program for the future Electron-Ion Collider, which is a new collider to be build in the US within the next decade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the cross section for the production of a W boson in association with b-jets in pp collisions at root s=7 TeV with the ATLAS detector

A measurement is presented of the cross section for the production of a W boson with one or two jets, of which at least one must be a b-jet, in pp collisions at {radical}s = 7 TeV. Production via top decay is not included in the signal definition. The measurement is based on 35 pb{sup -1} of data collected with the ATLAS detector at the LHC. The W + b-jet cross section is defined for jets reconstructed with the anti-kt clustering algorithm with transverse momentum above 25 GeV and rapidity within {+-}2.1. The b-jets are identified by reconstructing secondary vertices. The fiducial cross section is measured both for the electron and muon decay channel of the W boson and is found to be 10.2 {+-} 1.9(stat) {+-} 2.6(syst) pb for one lepton flavour. The results are compared with next-to-leading order QCD calculations, which predict a cross section smaller than, though consistent with, the measured value.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Processing of spectrally resolved x-ray images of inertial confinement fusion implosion cores recorded with multimonochromatic x-ray imagers

We discuss the processing of data recorded with multimonochromatic x-ray imagers (MMI) in inertial confinement fusion experiments. The MMI records hundreds of gated, spectrally resolved images that can be used to unravel the spatial structure of the implosion core. In particular, we present a new method to determine the centers in all the array of images, a better reconstruction technique of narrowband implosion core images, two algorithms to determine the shape and size of the implosion core volume based on reconstructed broadband images recorded along three-quasiorthogonal lines of sight, and the removal of artifacts from the space-integrated spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-207-09: Evaluating the Dosimetric Accuracy of Extended Field-Of-View CT Reconstructions Using Clinical Data with Real Patient Geometries

Purpose: To determine the accuracy of dose calculations performed with CT images reconstructed using extended field of view (FOV) algorithms. Methods: In this study we selected 6 radiotherapy patients (3 head and neck & 3 chest/pelvis) whose body circumferences extended past the 50 cm scan FOV in the treatment planning CT. Images acquired on a Siemens Sensation Open scanner, were reconstructed using the standard FOV (sFOV) and two different extended FOV algorithms, eFOV and HDFOV. A physician and dosimetrist identified the radiation target, critical organs, and external patient contour. A benchmark CT was created for each patient, consisting of an average of the 3 CT reconstructions with a density override applied to regions containing truncation artifacts, and was used to create an optimal radiation treatment plan. The plan was copied onto each reconstruction without density override and dose was recalculated. Results: The native sFOV dose calculations had the largest deviation from the benchmark (0.4 – 6.0%). Both the HDFOV and eFOV calculations showed improvement over the sFOV. For patients with a smooth patient contour, the HDFOV calculation had the least deviation from the benchmark (0.1–0.5%) compared to eFOV (0.4–1.8%). In cases with large amounts of tissue and irregular skin folds, the eFOV deviated the least from the benchmark (0.2–0.6%) compared to HDFOV (1.3–1.8%). It was observed that the eFOV scan has large image artifact in air with an average HU of −600 compared to the ideal of −1000. In these cases, the artifact in air appears to attenuate the dose and compensate for the missing tissue density. The HDFOV demonstrated minimal artifact in air. Conclusion: Both eFOV and HDFOV provide improved dose calculation accuracy. The HDFOV reconstruction provides a clearer patient border than the eFOV allowing for well-defined density overrides to be applied with minimal air artifact. This research was supported by Siemens Medical Solutions.

60 APPLIED LIFE SCIENCES↗

Optimal sensor placement for reconstructing wind pressure field around buildings using compressed sensing

Deciding how to optimally deploy sensors in a large, complex, and spatially extended structure is critical to ensure that the surface pressure field is accurately captured for subsequent analysis and design. In some cases, reconstruction of missing data is required in downstream tasks such as the development of digital twins. Here, this paper presents a data-driven sparse sensor selection algorithm, aiming to provide the most information contents for reconstructing aerodynamic characteristics of wind pressures over tall building structures parsimoniously. The algorithm first fits a set of basis functions to the training data, then applies a computationally efficient QR algorithm that ranks existing pressure sensors in order of importance based on the state reconstruction to this tailored basis. The findings of this study show that the proposed algorithm successfully re- constructs the aerodynamic characteristics of tall buildings from sparse measurement locations, generating stable and optimal solutions across a range of conditions. As a result, this study serves as a promising first step toward leveraging the success of data-driven and machine learning algorithms to supplement traditional genetic algorithms currently used in wind engineering.

42 ENGINEERING↗

Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H{sub 2}O mole fraction

To monitor two-dimensional (2D) distributions of temperature and H{sub 2}O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors’ knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H{sub 2}O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm{sup −1} (1343.3 nm) and 7185.6 cm{sup −1} (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H{sub 2}O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H{sub 2}O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ensemble‐Based, Large‐Eddy Reconstruction of Wind Turbine Inflow in a Near‐Stationary Atmospheric Boundary Layer Through Generative Artificial Intelligence

ABSTRACT To validate the second‐by‐second dynamics of turbines in field experiments, it is necessary to accurately reconstruct the winds going into the turbine. Current time‐resolved inflow reconstruction techniques estimate wind behavior in unobserved regions using relatively simple spectral‐based models of the atmosphere. Here, we develop a technique for time‐resolved inflow reconstruction that is rooted in a large‐eddy simulation model of the atmosphere. Our “large‐eddy reconstruction” technique blends observations and atmospheric model information through a diffusion model machine learning algorithm, allowing us to generate probabilistic ensembles of reconstructions for a single 10‐min observational period. Our generated inflows can be used directly by aeroelastic codes or as inflow boundary conditions in a large‐eddy simulation. We verify the second‐by‐second reconstruction capability of our technique in three synthetic field campaigns, finding positive Pearson correlation coefficient values () between ground‐truth and reconstructed streamwise velocity, as well as smaller positive correlation coefficient values for unobserved fields (spanwise velocity, vertical velocity, and temperature). We validate our technique in three real‐world case studies by driving large‐eddy simulations with reconstructed inflows and comparing to independent inflow measurements. The reconstructions are visually similar to measurements, follow desired power spectra properties, and track second‐by‐second behavior ().

17 WIND ENERGY↗

Anisotropic modeling and joint-MAP stitching for improved ultrasound model-based iterative reconstruction of large and thick specimens

One-sided non-destructive evaluation (NDE) is widely used to inspect materials, such as concrete structures in nuclear power plants (NPP). A widely used method for one-sided NDE is the synthetic aperture focusing technique (SAFT). The SAFT algorithm produces reasonable results when inspecting simple structures. However, for complex structures, such as heavily reinforced thick concrete structures, SAFT results in artifacts and hence there is a need for a more sophisticated inversion technique. Model-based iterative reconstruction (MBIR) algorithms, which are typically equivalent to regularized inversion techniques, offer a powerful framework to incorporate complex models for the physics, detector miscalibrations and the materials being imaged to obtain high quality reconstructions. Previously, we have proposed an ultrasonic MBIR method that signifcantly improves reconstruction quality compared to SAFT. However, the method made some simplifying assumptions on the propagation model and did not disucss ways to handle data that is obtained by raster scanning a system over a surface to inspect large regions. In this paper, we propose a novel MBIR algorithm that incorporates an anisotropic forward model and allows for the joint processing of data obtained from a system that raster scans a large surface. We demonstrate that the new MBIR method can produce dramatic improvements in reconstruction quality compared to SAFT and suppresses articfacts compared to the perviously presented MBIR approach.

Almansouri, Hani↗

SU-G-IeP3-10: Molecular Imaging with Clinical X-Ray Sources and Compton Cameras

Purpose: The application of Compton cameras (CC) is a novel approach translating XFCT to a practical modality realized with clinical CT systems without the restriction of pencil beams. The dual modality design offers additional information without extra patient dose. The purpose of this work is to investigate the feasibility and efficacy of using CCs for volumetric x-ray fluorescence (XF) imaging by Monte Carlo (MC) simulations and statistical image reconstruction. Methods: The feasibility of a CC for imaging x-ray fluorescence emitted from targeted lesions is examined by MC simulations. 3 mm diameter water spheres with various gold concentrations and detector distances are placed inside the lung of an adult human phantom (MIRD) and are irradiated with both fan and cone-beam geometries. A sandwich design CC composed of Silicon and CdTe is used to image the gold nanoparticle distribution. The detection system comprises four 16×26 cm{sup 2} detector panels placed on the chest of a MIRD phantom. Constraints of energy-, spatial-resolution, clinical geometries and Doppler broadening are taken into account. Image reconstruction is performed with a list-mode MLEM algorithm with cone-projector on a GPU. Results: The comparison of reconstruction of cone- and fan-beam excitation shows that the spatial resolution is improved by 23% for fan-beams with significantly decreased processing time. Cone-beam excitation increases scatter content disturbing quantification of lesions near the body surface. Spatial resolution and detectability limit in the center of the lung is 8.7 mm and 20 fM for 50 nm diameter gold nanoparticles at 20 mGy. Conclusion: The implementation of XFCT with a CC is a feasible method for molecular imaging with high atomic number probes. Given constrains of detector resolutions, Doppler broadening, and limited exposure dose, spatial resolutions comparable with PET and molecular sensitivities in the fM range are realizable with current detector technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delineation of geological facies from poorly differentiated data

The ability to delineate geologic facies and to estima.te their properties from sparse data is essential for modeling physical and biochemical processes occurring in the 'ubsurface. If such data are poorly differentiated, this challcnrring task is complicated further by the absence of a clear distinction between different hydrofacies even at locations where data. are available. vVe consider three alt mative approaches for analysis of poorly differentiated data: a k-means clU!:iterinrr algorithm, an expectation-maximization algorithm, and a minimum-variance algorithm. Two distinct synthetically generated geological settings are used to r:tnalyze the ability of these algorithmti to as ign accurately the membership of such data in a given geologic facies. On average, the minimum-variance algorithm provides a more robust p rformance than its two counterparts and when combined with a nearest-neighbor algorithm, it also yields the most accurate reconstruction of the boundaries between the facies.

58 GEOSCIENCES↗

Flux Cube Reconstruction from Slitless Spectroscopy

Slitless spectroscopy enables efficient, large-area surveys without target preselection, yet it faces challenges from source blending, higher noise, and lost spatial–spectral information. We present an advanced, nonparametric, data-driven algorithm that leverages multiple dispersion angles to reconstruct three-dimensional flux distributions, providing low-resolution integral field unit capabilities from slitless data. By treating each pixel as an independent element, our method naturally handles source confusion without requiring prior assumptions regarding redshifts, templates, or model libraries. We validate the algorithm using simulated Roman Space Telescope wide-field slitless spectroscopy images that are equivalent to what is expected from the High-Latitude Time-Domain Survey. First, we demonstrate that a host-galaxy model reconstructed from multiple dispersion angles can be used to accurately subtract host light from a transient, recovering a Type Ia supernova spectrum with minimal bias. Second, we showcase a high-fidelity flux-cube reconstruction of a complex galaxy, successfully measuring the redshift and recovering continuum, emission, and absorption features. This approach highlights the potential of multi-dispersion-angle slitless data to provide spatially resolved spectral information in a nonparametric way, which is traditionally accessible only with integral field spectroscopy, opening a new window into large, unbiased, and spatially resolved studies of galaxy evolution.

Griggio, M. [Space Telescope Science Institute, Ba↗

Slicing with deep learning models at ProtoDUNE-SP

DUNE is a cutting-edge experiment aiming to study neutrinos in detail, with a special focus on the flavor oscillation mechanism. The prototype of the DUNE Far Detector Single Phase TPC (ProtoDUNE-SP) was built and operated at CERN with a full set of reconstruction tools. To implement these reconstruction tools, Pandora, a multi-algorithm framework, has been developed. A large number of these algorithms, some of them being exploiting traditional clustering, detector physics and deep learning approaches, have been applied to images to gradually build up a picture out of singular events. One of such algorithms is the Pandora slicing algorithm which aims to partition the detector hits of an event in sets called slices. Each slice represents a single interaction in the detector and should identify all the hits related to the interacting particle and its subsequent decay products. We expect the order of tens of slices per event in ProtoDUNE-SP. In this paper we present a deep learning approach to the problem, designing a model able to outperform the state-of-the-art slicing algorithm which is currently implemented within Pandora. We assess the performance of our tool in terms of efficiency and accuracy, while exploiting hardware accelerating setups. The ultimate goal is to incorporate this deep learning approach in the Pandora reconstruction tool.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Textureless Macula Swelling Detection with Multiple Retinal Fundus Images

Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. We also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.

60 APPLIED LIFE SCIENCES↗