Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pattern recognition for Space Applications Center director's discretionary fund

Results and conclusions are presented on the application of recent developments in pattern recognition to spacecraft star mapping systems. Sensor data for two representative starfields are processed by an adaptive shape-seeking version of the Fc-V algorithm with good results. Cluster validity measures are evaluated, but not found especially useful to this application. Recommendations are given two system configurations worthy of additional study,

Singley, M. E.↗

Sensitivity of optimized control systems to minor structural modifications

A procedure for checking whether small changes in a structure have the potential for significant enhancements of its optimized vibration control system is described. The first step in the procedure consists of the calculation of the sensitivity of the parameters of the optimized control system to small changes in the structural parameters. Theh second step consists of the optimization of the structural parameters to produce maximal increase in the performance of the control system with minimal change in the structure. The procedure has been demonstrated for a flexible laboratory structure controlled by several rate-feedback colocated force-actuator velocity-sensor pairs. Significant improvements in the performance of the control system were obtained with small structural modifications. Analytical predictions of such effects have also been validated experimentally.

Haftka, R. T.↗

Determination of cloud liquid water content using the SSM/I

As part of a calibration/validation effort for the special sensor microwave/imager (SSM/I), coincident observations of SSM/I brightness temperatures and surface-based observations of cloud liquid water were obtained. These observations were used to validate initial algorithms and to derive an improved algorithm. The initial algorithms were divided into latitudinal-, seasonal-, and surface-type zones. It was found that these initial algorithms, which were of the D-matrix type, did not yield sufficiently accurate results. The surface-based measurements of channels were investigated; however, the 85V channel was excluded because of excessive noise. It was found that there is no significant correlation between the SSM/I brightness temperatures and the surface-based cloud liquid water determination when the background surface is land or snow. A high correlation was found between brightness temperatures and ground-based measurements over the ocean.

Alishouse, John C.↗

An expert system for monitoring dynamic aspects of RCS

An expert system (ARC) based on the MIMIC(2) framework is being developed for assistance in monitoring the Space Shuttle reaction control system (RCS) and in training RCS mission controllers. ARC has four components: a hypothesis generator, a model-constructor, a model-simulator and a matcher. The hypothesis generator examines current readings of sensors to generate a set of hypotheses. The model constructor generates models from these hypotheses. The simulator predicts future behaviors of the system. The matcher validates hypotheses by testing the predicted states against real data. The hypothesis generator postulates faults using model-based reasoning (MBR), learned rules from real data, and expert-defined rules. The simulator uses a qualitative QSIM model of the RCS which can handle both nominal modes as well as a variety of fault models. This allows the simulator to simulate the system even when one or more components have degraded. Finally, the matcher is responsible for comparing readings against predictions and calculating confidence in a particular hypothesis.

Kulkarni, Deepak↗

Active suspension design for a Large Space Structure ground test facility

The expected future high performance requirements for Large Space Structures (LSS) enforce technology innovations such as active vibration damping techniques e.g., by means of structure sensors and actuators. The implementation of new technologies like that requires an interactive and integrated structural and control design with an increased effort in hardware validation by ground testing. During the technology development phase generic system tests will be most important covering verification and validation aspects up to the preparation and definition of relevant space experiments. For many applications using advanced designs it is deemed necessary to improve existing testing technology by further reducing disturbances and gravity coupling effects while maintaining high performance reliability. A key issue in this context is the improvement of suspension techniques. The ideal ground test facility satisfying these requirements completely will never be found. The highest degree of reliability will always be obtained by passive suspension methods taking into account severe performance limitations such as non-zero rigid body modes, restriction of degrees of freedom of motion and frequency response limitations. Passive compensation mechanisms, e.g., zero-spring-rate mechanisms, either require large moving masses or they are limited with respect to low-frequency performance by friction, stiction or other non-linear effects. With active suspensions these limitations can be removed to a large extent thereby increasing the range of applications. Despite an additional complexity which is associated with a potential risk in reliability their development is considered promising due to the amazing improvement of real-time control technology which is still continuing.

Lange, Thomas J. H.↗

A Robust Vision-Based Algorithm for Detecting and Classifying Small Orbital Debris Using On-Board Optical Cameras

This study develops a vision-based detection and classification algorithm to address the challenges of in-situ small orbital debris environment classification including debris observability and instrument requirements for small debris observation. The algorithm operates in near real time and is robust under difficult tasks in moving objects classification such as multiple moving objects, objects with various movement trajectories and speeds, very small or faint objects, and substantial background motion. The performance of the algorithm is optimized and validated using space image data available through simulated environments generated using NASA Marshall Space Flight Centers Dynamic Star Field Simulator of on-board optical sensors and cameras.

Zamani, Yasin↗

The Cumulus and Stratocumulus CloudSat-CALIPSO Dataset (CASCCAD)

Low clouds continue to contribute greatly to the uncertainty in cloud feedback estimates. Depending on whether a region is dominated by cumulus (Cu) or stratocumulus (Sc) clouds, the interannual low-cloud feedback is somewhat different in both spaceborne and large-eddy simulation studies. Therefore, simulating the correct amount and variation of the Cu and Sc cloud distributions could be crucial to predict future cloud feedbacks. Here we document spatial distributions and profiles of Sc and Cu clouds derived from Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) and CloudSat measurements. For this purpose, we create a new dataset called the Cumulus And Stratocumulus CloudSat-CALIPSO Dataset (CASCCAD), which identifies Sc, broken Sc, Cu under Sc, Cu with stratiform outflow and Cu. To separate the Cu from Sc, we design an original method based on the cloud height, horizontal extent, vertical variability and horizontal continuity, which is separately applied to both CALIPSO and combined CloudSat–CALIPSO observations. First, the choice of parameters used in the discrimination algorithm is investigated and validated in selected Cu, Sc and Sc–Cu transition case studies. Then, the global statistics are compared against those from existing passive- and active-sensor satellite observations. Our results indicate that the cloud optical thickness – as used in passive-sensor observations – is not a sufficient parameter to discriminate Cu from Sc clouds, in agreement with previous literature. Using clustering-derived datasets shows better results although one cannot completely separate cloud types with such an approach. On the contrary, classifying Cu and Sc clouds and the transition between them based on their geometrical shape and spatial heterogeneity leads to spatial distributions consistent with prior knowledge of these clouds, from ground-based, ship-based and field campaigns. Furthermore, we show that our method improves existing Sc–Cu classifications by using additional information on cloud height and vertical cloud fraction variation. Finally, the CASCCAD datasets provide a basis to evaluate shallow convection and stratocumulus clouds on a global scale in climate models and potentially improve our understanding of low-level cloud feedbacks. The CASCCAD dataset (Cesana, 2019, https://doi.org/10.5281/zenodo.2667637) is available on the Goddard Institute for Space Studies (GISS) website at https://data.giss.nasa.gov/clouds/casccad/ (last access: 5 November 2019) and on the zenodo website at https://zenodo.org/record/2667637 (last access: 5 November 2019).

Cesana, Gregory V.↗

IceCube: Demonstration of an 883 GHz Radiometer for Ice Cloud Remote Sensing

IceCube was a technology demonstration of an 883 GHz heterodyne radiometer on a 3U CubeSat for ice cloud characterization. The project was a collaboration between Goddard Space Flight Center, Virginia Diodes Inc., and Wallops Flight Facility. IceCube was launched to the International Space Station (ISS) in April 2017, and was deployed to the orbit in May 2017. The radiometer measured ice cloud emissions from an ISS orbit for over 15 months. IceCube generated the first 883 GHz cloud map over a large operation temperature range of (5 ºC—37 ºC). Cloud ice plays a major role in the cloud precipitation process and Earth’s energy budget. Ice clouds are used in global circulation models as tuning parameters to achieve model agreement with observation at the top of the atmosphere in the radiation budget and at the bottom for precipitation, however, due to a lack of accurate ice cloud measurements large uncertainties exist in these models. Submillimeter wave remote sensing is capable of addressing this issue by measuring cloud ice mass and microphysical properties in the middle-to-upper troposphere. This fills the sensitivity gap not covered by the visible/infrared and microwave sensors [1]. The goal of IceCube was to increase the TRL of a heterodyne 883 GHz radiometer (using commercial parts) from 5 to 7 by validating the performance in a relevant spaceflight environment. The design of the radiometer was driven by frequency of operation, bandwidth, calibration, available power, and thermal environment requirements. The design included a 15 mm aperture off-axis parabolic reflector with a Potter feed horn, an 883 GHz 2nd-harmonic mixer that is fed by a local oscillator chain with a 24.3 GHz dielectric resonator (MLA), followed by a 6 GHz bandwidth centered at 9 GHz intermediate frequency assembly (IFA), receiver interface card, and power distribution unit. The IFA included an internal noise diode calibration to separate the MLA performance from the rest of the system. For this the radiometer had four operational states: antenna, antenna + noise, reference, and reference + noise; each state’s duration was 10 ms. The total power dissipation of the instrument was 5.6 W. The spacecraft had spinning capabilities to provide a cold sky view for calibration. We present the instrument design, ground test results, challenges, and highlight some of the flight measurements.

N Ehsan↗

Synthetic Hyperspectral Data for Global Water Quality Algorithm Development

Eutrophication and increasing prevalence of potentially toxic algal blooms (cyanoHABs) among global inland water bodies have become a major ecological concern and require direct attention. There is now a growing necessity to develop pragmatic approaches that allow timely and effective extrapolation of local aquatic processes, to spatially resolved global products. Planned aquatic biogeochemistry remote sensing data products from hyperspectral imagers such as NASA’s Surface Biology and Geology (SBG) mission and relevant aquatic sensor sensitivity precursor airborne imaging spectrometer data provide unprecedented radiometric resolution and sensor sensitivity for characterizing complex aquatic ecosystems. However, scarcity of high-quality freshwater in-situ optical data hinders our capability to develop and validate robust retrieval algorithms. A state-of-the-art synthetic dataset of paired top-of-atmosphere, bottom-of-atmosphere, and optical and biogeophysical data was developed through radiative transfer modeling to simulate natural freshwater ecosystems. A synthetic or precursor dataset for SBG is being used to train robust machine learning models to derive water quality products pertinent to SBG mission objectives. The dataset is also used to show the potential of performing vigorous aquatic sensitivity studies and explored pathways for how best to optimize hyperspectral data for machine learning development. A processing pipeline and resultant global synthetic/precursor dataset for inland waters is presented to establish the innovation for water quality studies of inland waters globally. Optical Society of America Imaging and Applied Optics Congress, Hyperspectral Imaging and Sounding of the Environment (OSA HISE) Meeting, 19-23 July 2021, Virtual Meeting, https://www.osa.org/enus/meetings/osa_meetings/optical_sensors_and_sensing_congress/program/hyperspectral_imaging_and_sounding_of_the_environm/

Synthetic↗

Hydrogen Wide Area Monitoring of LH2 Releases at HSE for the PRESHLY Project

The characterization of liquid hydrogen (LH2) releases has been identified as an international research priority to expand the safe use of hydrogen as an energy carrier. Empirical field measurements such as those afforded by Hydrogen Wide Area Monitoring (HyWAM) can elucidate the behavior of LH2 releases, which can then be used to support and validate dispersion models. HyWAM can be defined as the quantitative three-dimensional spatial and temporal profiling of planned or unintentional hydrogen releases. The NREL Sensor Laboratory developed a HyWAM based upon a distributed array of hydrogen Sensors. The NREL Sensor Laboratory and Health and Safety Executive (HSE) formally committed to collaborate on profiling GH2 and LH2 releases, which allowed for the integration of the NREL HyWAM into the HSE LH2 release behavior investigation supported by the FCH JU Prenormative Research for the Safe Use of Liquid Hydrogen (PRESLHY) program. A HyWAM system consisting of 32 hydrogen measurement points and co-located temperature sensors were distributed downstream of the LH2 release apparatus developed by HSE. In addition, there were proximal wind and weather monitors. In a separate presentation at this conference "HSE SD Experimental Summary for the Characterisation, Dispersion and Electrostatic Hazards of LH2 for the PRESLHY Project" HSE researchers summarize the experimental apparatus and experimental protocols utilized in the HSE LH2 releases that were performed under the auspices of PRESLHY. To supplement the HSE presentation, this presentation will focus on the spatial and temporal behavior LH2 releases as measured by the NREL HyWAM. Correlations to ambient conditions, such as wind speed and direction, plume temperature and hydrogen concentrations will be discussed in addition to the design and performance of the NREL HyWAM, and its potential for improving hydrogen facility safety.

HYDROGEN↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ANALYSIS OF THE MSL/MEDLI ENTRY DATA WITH COUPLED CFD AND MATERIAL RESPONSE.

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heat-shield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material. PICA is a lightweight carbon fiber/polymeric resin material that offers out-standing performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on Open-FOAM (PATO) using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA, is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Mars Science Laboratory↗

Lightning and 85-GHz MCSs in the Global Tropics

Numerous observations of tropical convection show that tropical continental mesoscale convective systems (MCSs) are much more prolific lightning producers than their oceanic counterparts. Satellite-based climatologies using 85-GHz passive microwave ice-scattering signatures from the Special Sensor Microwave/Imager (SSM/I) indicate that MCSs of various size and intensity are found throughout the global tropics. In contrast, global lightning distributions show a strong land bias with an order of magnitude difference between land and ocean lightning. This is somewhat puzzling, since 85-GHz ice-scattering and the charge separation processes that lead to lightning are both thought to depend upon the existence of large graupel particles. The fact that low 85-GHz brightness temperatures are observed in tropical oceanic MCSs containing virtually no lightning leads to the postulate that tropical oceanic and tropical continental MCSs have fundamentally different hydrometeor profiles through the mixed phase region of the cloud (0 C <= T <= 20 C). Until recently, validation of this postulate has not been practicable on a global scale. Recent deployment of the Tropical Rainfall Measuring Mission (TRMM) satellite presents a unique opportunity for MCS studies. The multi-sensor instrument ensemble aboard TRMM, including a multi-channel microwave radiometer, the Lightning Imaging Sensor (LIS), and the first space-borne radar, facilitates high-resolution case studies of MCS structure throughout the global tropics. An important precursor, however, is to better understand the distribution of MCSs and lightning in the tropics. With that objective in mind, this research undertakes a systematic comparison of 85-GHz-defined MCSs and lightning over the global tropics for a full year, as an initial step toward quantifying differences between land and ocean convective systems.

Toracinta, E. Richard↗

Analysis of MSL/MEDLI Entry Data with Coupled CFD and Material Response

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on OpenFOAM (PATO) [4,5,6] using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA [7], is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Thermal Protection Systems↗

Validation of Surface Bio-Optical Properties in the Gulf of Maine as a Means for Improving Satellite Primary Production Estimates

One of the greatest challenges in providing sea-truth data for various ocean color sensors is climatology. This is particularly true in the Gulf of Maine since it is cloudy and foggy more than it is clear; the climatology shows on average, about one in four to five days has clear skies with clear days slightly more frequent in the late summer and early fall. Our strategy has been to use a ship of opportunity where one has choice of the sampling days. This provides much better flexibility to sample during clear periods with good satellite coverage. Our Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) contract has been to use the M/S Scotia Prince ferry as a ship of opportunity, running between Portland, Maine and Yarmouth, NS. Measurements include continuous, surface, along-track fluorescence, two independent measures of backscattering, total light scattering, absorption, beam attenuation, above-water remote sensing reflectance, calcite-dependent light scattering, temperature, and salinity. Expendable bathythermography (XBT) drops allow acquisition of vertical temperature information, useful for defining isopycnal slope, which affects primary production. These data are comparable to a previous program from early 1982, where a ship of opportunity program (SOOP) was run on the truck ferry, M/V Marine Evangeline, which ran along the same transect. These surface data were combined with satellite-derived sea surface temperature fields to examine the Maine coastal current. Unfortunately, this program stopped in 1982. The ongoing SIMBIOS results will dovetail nicely with the previous work (which also had Coastal Zone Color Scanner (CZCS) coverage) for looking at any long-term changes in the Gulf of Maine hydrography, bio-optics, and biogeochemistry.

Balch, William M.↗

Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

Galileo↗