At least 1,171 records · Page 65

Non-Intrusive Cable Tester

A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.

Medelius, Pedro J.↗

Is the signal from Cyg X-3, as recorded in some underground experiments, real?

Most of the excitement concerning the underground detection of signals from Cyg X-3 comes not from astrophysical grounds, but from the contradiction with surface experimental data. Believing in the Cyg X-3 signal underground and also that the main processes of muon production are well knownm the conclusion was drawn that the signal in EAS Cherenkov or counter experiments could be remarkably high, which is not the case. Possible solutions to this discrepancy are discussed.

Chudakov, A. E.↗

Asymmetric spin absorption across a low-resistance oxide barrier

An unconventional method of nonlocal spin detection is demonstrated in mesoscopic lateral spin valves at room temperature. Clear nonlocal spin signals are detected between the two ends of an extended ferromagnetic spin detector. This is different from the conventional method in which the nonlocal voltage is measured between the spin detector and the nonmagnetic channel. The results can be understood as spatially non-uniform absorption of a pure spin current into the spin detector across a low-resistance oxide interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel Spectral Acquisition with Orthogonal ICR Cells

FT-based high performance mass analyzers yield increased resolving power and mass measurement accuracy, yet require increased duration of signal acquisition that can limit many applications. The implementation of stronger magnetic fields, multiple detection electrodes for harmonic signal detection, and an array of multiple mass analyzers arranged along the magnetic field axis have been used to decrease required acquisition time. The results presented here show that multiple ion cyclotron resonance (ICR) mass analyzers can also be implemented orthogonal to the central magnetic field axis. The orthogonal ICR cell system presented here consisting of two cells (master and slave cells) was constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. A master cell was positioned, as is normally done with ICR cells, on the central magnetic field axis and a slave cell was located off this central axis, but directly adjacent and alongside the master cell. To achieve ion transfer between cells, ions that were initially trapped in the master cell were drifted across the magnetic field into the slave cell with application of a small DC field applied perpendicularly to the magnetic field axis. A subsequent population of ions was injected and accumulated in the master cell. Simultaneous excitation of cyclotron motion of ions in both cells was carried out; ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition with this orthogonal dual ICR cell array. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Neutron Measurement Capabilities; Expanding the Limits of Correlated Neutron Counting

A number of technical and practical limitations exist within the neutron correlated counting techniques used in safeguards, especially within the algorithms that are used to process and analyze the detected neutron signals. A multi-laboratory effort is underway to develop new and improved analysis and data processing algorithms based on fundamental physics principles to extract additional or more accurate information about nuclear material bearing items.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double-modulation spectroscopy of molecular ions - Eliminating the background in velocity-modulation spectroscopy

Velocity-modulation spectroscopy is an established technique for performing laser absorption spectroscopy of molecular ions in a discharge. However, such experiments are often plagued by a coherent background signal arising from emission from the discharge or from electronic pickup. Fluctuations in the background can obscure the desired signal. A simple technique using amplitude modulation of the laser and two lock-in amplifiers in series to detect the signal is demonstrated. The background and background fluctuations are thereby eliminated, facilitating the detection of molecular ions.

Lan, Guang↗

Method of detecting luminescent target ions with modified magnetic microspheres

This invention provides methods of using modified magnetic microspheres to extract target ions from a sample in order to detect their presence in a microfluidic environment. In one or more embodiments, the microspheres are modified with molecules on the surface that allow the target ions in the sample to form complexes with specific ligand molecules on the microsphere surface. In one or more embodiments, the microspheres are modified with molecules that sequester the target ions from the sample, but specific ligand molecules in solution subsequently re-extract the target ions from the microspheres into the solution, where the complexes form independent of the microsphere surface. Once the complexes form, they are exposed to an excitation wavelength light source suitable for exciting the target ion to emit a luminescent signal pattern. Detection of the luminescent signal pattern allows for determination of the presence of the target ions in the sample.

47 OTHER INSTRUMENTATION↗

Anthropogenic climate change impacts exacerbate summer forest fires in California

Record-breaking summer forest fires have become a regular occurrence in California. Observations indicate a fivefold increase in summer burned area (BA) in forests in northern and central California during 1996 to 2021 relative to 1971 to 1995. While the higher temperature and increased dryness have been suggested to be the leading causes of increased BA, the extent to which BA changes are due to natural variability or anthropogenic climate change remains unresolved. Here, we develop a climate-driven model of summer BA evolution in California and combine it with natural-only and historical climate simulations to assess the importance of anthropogenic climate change on increased BA. Our results indicate that nearly all the observed increase in BA is due to anthropogenic climate change as historical model simulations accounting for anthropogenic forcing yield 172% (range 84 to 310%) more area burned than simulations with natural forcing only. We detect the signal of combined historical forcing on the observed BA emerging in 2001 with no detectable influence of the natural forcing alone. In addition, even when considering fuel limitations from fire-fuel feedbacks, a 3 to 52% increase in BA relative to the last decades is expected in the next decades (2031 to 2050), highlighting the need for proactive adaptations.

54 ENVIRONMENTAL SCIENCES↗

Advanced detectors and signal processing

Continued progress is reported toward development of a silicon on garnet technology which would allow fabrication of advanced detection and signal processing circuits on bubble memories. The first integrated detectors and propagation patterns have been designed and incorporated on a new mask set. In addition, annealing studies on spacer layers are performed. Based on those studies, a new double layer spacer is proposed which should reduce contamination of the silicon originating in the substrate. Finally, the magnetic sensitivity of uncontaminated detectors from the last lot of wafers is measured. The measured sensitivity is lower than anticipated but still higher than present magnetoresistive detectors.

Greve, D. W.↗

Flight test results of a vector-based failure detection and isolation algorithm for a redundant strapdown inertial measurement unit

Flight test results of a vector-based fault-tolerant algorithm for a redundant strapdown inertial measurement unit are presented. Because the inertial sensors provide flight-critical information for flight control and navigation, failure detection and isolation is developed in terms of a multi-level structure. Threshold compensation techniques for gyros and accelerometers, developed to enhance the sensitivity of the failure detection process to low-level failures, are presented. Four flight tests, conducted in a commercial transport type environment, were used to determine the ability of the failure detection and isolation algorithm to detect failure signals, such a hard-over, null, or bias shifts. The algorithm provided timely detection and correct isolation of flight control- and low-level failures. The flight tests of the vector-based algorithm demonstrated its capability to provide false alarm free dual fail-operational performance for the skewed array of inertial sensors.

Morrell, F. R.↗

Digital Interface Board to Control Phase and Amplitude of Four Channels

An increasing number of parts are designed with digital control interfaces, including phase shifters and variable attenuators. When designing an antenna array in which each antenna has independent amplitude and phase control, the number of digital control lines that must be set simultaneously can grow very large. Use of a parallel interface would require separate line drivers, more parts, and thus additional failure points. A convenient form of control where single-phase shifters or attenuators could be set or the whole set could be programmed with an update rate of 100 Hz is needed to solve this problem. A digital interface board with a field-programmable gate array (FPGA) can simultaneously control an essentially arbitrary number of digital control lines with a serial command interface requiring only three wires. A small set of short, high-level commands provides a simple programming interface for an external controller. Parity bits are used to validate the control commands. Output timing is controlled within the FPGA to allow for rapid update rates of the phase shifters and attenuators. This technology has been used to set and monitor eight 5-bit control signals via a serial UART (universal asynchronous receiver/transmitter) interface. The digital interface board controls the phase and amplitude of the signals for each element in the array. A host computer running Agilent VEE sends commands via serial UART connection to a Xilinx VirtexII FPGA. The commands are decoded, and either outputs are set or telemetry data is sent back to the host computer describing the status and the current phase and amplitude settings. This technology is an integral part of a closed-loop system in which the angle of arrival of an X-band uplink signal is detected and the appropriate phase shifts are applied to the Ka-band downlink signal to electronically steer the array back in the direction of the uplink signal. It will also be used in the non-beam-steering case to compensate for phase shift variations through power amplifiers. The digital interface board can be used to set four 5-bit phase shifters and four 5-bit attenuators and monitor their current settings. Additionally, it is useful outside of the closed-loop system for beamsteering alone. When the VEE program is started, it prompts the user to initialize variables (to zero) or skip initialization. After that, the program enters into a continuous loop waiting for the telemetry period to elapse or a button to be pushed. A telemetry request is sent when the telemetry period is elapsed (every five seconds). Pushing one of the set or reset buttons will send the appropriate command. When a command is sent, the interface status is returned, and the user will be notified by a pop-up window if any error has occurred. The program runs until the End Program button is depressed.

Smith, Amy E.↗

HD 2685 b: a hot Jupiter orbiting an early F-type star detected by TESS

We report on the confirmation of a transiting giant planet around the relatively hot (T(eff) = 6801 ± 76 K) star HD2685, whose transit signal was detected in Sector 1 data of NASA’s TESS mission. We confirmed the planetary nature of the transit signal using Doppler velocimetric measurements with CHIRON, CORALIE, and FEROS, as well as using photometric data obtained with the Chilean-Hungarian Automated Telescope and the Las Cumbres Observatory. From the joint analysis of photometry and radial velocities, we derived the following parameters for HD2685 b: P = 4.12688(+0.00005,-0.00004) days, e = 0.091(+0.039, -0.047), MP = 1.17 ± 0.12 M(J) , and R(P) =1.44 ± 0.05 R(J). This system is a typical example of an inflated transiting hot Jupiter in a low-eccentricity orbit. Based on the apparent visual magnitude (V = 9.6 mag) of the host star, this is one of the brightest known stars hosting a transiting hot Jupiter, and it is a good example of the upcoming systems that will be detected by TESS during the two-year primary mission. This is also an excellent target for future ground- and space-based atmospheric characterization as well as a good candidate for measuring the projected spin-orbit misalignment angle through the Rossiter–McLaughlin effect.

Matías I. Jones↗

Colorimetric-Luminance Readout for Quantitative Analysis of Fluorescence Signals with a Smartphone CMOS Sensor

Smartphones have shown promise as an enabling technology for portable and distributed point-of-care diagnostic tests. The CMOS camera sensor can be used for detecting optical signals, including fluorescence for applications such as isothermal nucleic acid amplification tests. However, such analysis is typically limited mostly to end point detection of single targets. In this paper, we present a smartphone-based image analysis pipeline that utilizes the CIE xyY (chromaticity-luminance) color space to measure the luminance (in lieu of RGB intensities) of fluorescent signals arising from nucleic acid amplification targets, with a discrimination sensitivity (ratio between the positive to negative signals), which is an order of magnitude more than traditional RGB intensity based analysis. Furthermore, the chromaticity part of the analysis enables reliable multiplexed detection of different targets labeled with spectrally separated fluorophores. We apply this chromaticity-luminance formulation to simultaneously detect Zika and chikungunya viral RNA via end point RT-LAMP (Reverse transcription Loop-Mediated isothermal amplification). We also show real time LAMP detection of Neisseria gonorrhoeae samples down to a copy number of 3.5 copies per 10 μL of reaction volume in our smartphone-operated portable LAMP box. Finally, our chromaticity-luminance analysis is readily adaptable to other types of multiplexed fluorescence measurements using a smartphone camera.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of environmental backgrounds on atmospheric monitoring of nuclear explosions

Radionuclide monitoring for nuclear explosions includes measuring radioactive aerosol and noble gas concentrations in the atmosphere. The International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty (CTBT) has made such measurements for decades, revealing much about how atmospheric radioactivity impacts the sensitivity of the network. For example, civilian emissions of radioiodine make a substantial regional impact, but a minor global impact, while civilian radioxenon emissions create major regional and complex global impacts. This example statement is strongly influenced by the minimum signal level anticipated to be interesting. The original design of the IMS anticipated relatively large signal levels, and the accomplished IMS network substantially meets or exceeds the sensitivity needed to detect those signal levels. Much lower signal levels can be motivated, which could require reconsideration of station sensitivity. Using measured and simulated background concentrations, various possible desired signal levels, and an innovative anomaly threshold, maps of sensitivity and a station ranking are developed for current and future stations. These provide a strong motivation for additional experimentation to learn about sources and the potential plusses of new technology.

Eslinger, Paul W.↗

Neutron scattering study of the kagome metal Sc 3 Mn 3 Al 7 Si 5

Sc 3 Mn 3 Al 7 Si 5 is a rare example of a correlated metal in which the Mn moments form a kagome lattice. The absence of magnetic ordering to the lowest temperatures suggests that geometrical frustration of magnetic interactions may lead to strong magnetic fluctuations. We have performed inelastic neutron scattering measurements on Sc 3 Mn 3 Al 7 Si 5 , finding that phonon scattering dominates for energies from ~20–50 meV. These results are in good agreement with ab initio calculations of the phonon dispersions and densities of states, and as well reproduce the measured specific heat. A weak magnetic signal was detected at energies less than ~10 meV, present only at the lowest temperatures. The magnetic signal is broad and quasielastic, as expected for metallic paramagnets.

36 MATERIALS SCIENCE↗

A carrier sensed multiple access protocol for high data base rate ring networks

The results of the study of a simple but effective media access protocol for high data rate networks are presented. The protocol is based on the fact that at high data rates networks can contain multiple messages simultaneously over their span, and that in a ring, nodes used to detect the presence of a message arriving from the immediate upstream neighbor. When an incoming signal is detected, the node must either abort or truncate a message it is presently sending. Thus, the protocol with local carrier sensing and multiple access is designated CSMA/RN. The performance of CSMA/RN with TTattempt and truncate is studied using analytic and simulation models. Three performance factors, wait or access time, service time and response or end-to-end travel time are presented. The service time is basically a function of the network rate, it changes by a factor of 1 between no load and full load. Wait time, which is zero for no load, remains small for load factors up to 70 percent of full load. Response time, which adds travel time while on the network to wait and service time, is mainly a function of network length, especially for longer distance networks. Simulation results are shown for CSMA/RN where messages are removed at the destination. A wide range of local and metropolitan area network parameters including variations in message size, network length, and node count are studied. Finally, a scaling factor based upon the ratio of message to network length demonstrates that the results, and hence, the CSMA/RN protocol, are applicable to wide area networks.

Foudriat, E. C.↗

Diplex Fiber-Optic Link For Frequency And Time Signals

Diplex fiber-optic link part of Goldstone Deep Space Communications complex. Relatively inexpensive equipment delivers signals of high quality. At central station, signal combiner adds 5-MHz reference-frequency signal and 36-bit time-code signal, forming composite signal, which modulates light transmitted along optical fiber. At remote station, fiber-optic receiver detects composite signal and provides input to diplexer, which separates frequency reference signal from time-code signal. Signals then amplified to desired levels.

Lutes, George F.↗

Method of multiplexed analysis using ion mobility spectrometer

A method for analyzing analytes from a sample introduced into a Spectrometer by generating a pseudo random sequence of a modulation bins, organizing each modulation bin as a series of submodulation bins, thereby forming an extended pseudo random sequence of submodulation bins, releasing the analytes in a series of analyte packets into a Spectrometer, thereby generating an unknown original ion signal vector, detecting the analytes at a detector, and characterizing the sample using the plurality of analyte signal subvectors. The method is advantageously applied to an Ion Mobility Spectrometer, and an Ion Mobility Spectrometer interfaced with a Time of Flight Mass Spectrometer.

47 OTHER INSTRUMENTATION↗