Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Projecting Life-Cycle Environmental Impacts of Corn Production in the U.S. Midwest under Future Climate Scenarios using machine learning approach

Emission factors and process-based mechanism models are popular approaches used to estimate life-cycle environmental impacts. However, emission factors are often incapable of describing spatial and temporal heterogeneity of agricultural emissions, whereas process-based mechanism models, capable of capturing the heterogeneity, tend to be very complicated, and time-consuming. Efficient predictions of life-cycle environmental impacts from agricultural production are lacking. This study develops a rapid predictive model to quantify life-cycle global warming (GW), eutrophication (EU) and acidification (AD) impacts of corn production using a novel machine learning approach. We used the boosted regression tree (BRT) model to estimate current and future life-cycle environmental impacts of corn production in 12 U.S. Midwest at county scale under four Intergovernmental Panel on Climate Change (IPCC)’s climate scenarios (RCP2.6. 4.5, 6.0, and 8.5) for years 2009-2100. Results show that future life-cycle GW, EU and AD impacts of corn production will increase under all four scenarios, with the worst environmental impacts shown under the RCP 8.5 scenario. Significant spatial variation were estimated to be 3.6, 29.9 and 1.8-folds under the RCP4.5 scenario, and 6.6, 152.9 and 1.6-folds under the RCP8.5 scenario, respectively. Findings from this study demonstrate the importance of considering county-level life-cycle environmental impacts and the influences of climate change in future years to aid in developing potential adaptation and mitigation programs and policies.

Machine learning, climate change, projections, env↗

Efficient sampling for spatial uncertainty qualification in multibody system dynamics applications.

We present two methods for efficiently sampling the response (trajectory space) of multibody systems operating under spatial uncertainty, when the latter is assumed to be representable with Gaussian processes. In this case, the dynamics (time evolution) of the multibody systems depends on spatially indexed uncertain parameters that span infinite-dimensional spaces. This places a heavy computational burden on existing methodologies, an issue addressed herein with two new conditional sampling approaches. When a single instance of the uncertainty is needed in the entire domain, we use a fast Fourier transform technique. When the initial conditions are fixed and the path distribution of the dynamical system is relatively narrow, we use an incremental sampling approach that is fast and has a small memory footprint. Both methods produce the same distributions as the widely used Cholesky-based approaches. We illustrate this convergence at a smaller computational effort and memory cost for a simple non-linear vehicle model.

97 MATHEMATICS AND COMPUTING↗

Brg1 coordinates multiple processes during retinogenesis and is a tumor suppressor in retinoblastoma

Retinal development requires precise temporal and spatial coordination of cell cycle exit, cell fate specification, cell migration and differentiation. When this process is disrupted, retinoblastoma, a developmental tumor of the retina, can form. Epigenetic modulators are central to precisely coordinating developmental events, and many epigenetic processes have been implicated in cancer. Studying epigenetic mechanisms in development is challenging because they often regulate multiple cellular processes; therefore, elucidating the primary molecular mechanisms involved can be difficult. Here we explore the role of Brg1 (Smarca4) in retinal development and retinoblastoma in mice using molecular and cellular approaches. Brg1 was found to regulate retinal size by controlling cell cycle length, cell cycle exit and cell survival during development. Brg1 was not required for cell fate specification but was required for photoreceptor differentiation and cell adhesion/polarity programs that contribute to proper retinal lamination during development. The combination of defective cell differentiation and lamination led to retinal degeneration in Brg1-deficient retinae. Despite the hypocellularity, premature cell cycle exit, increased cell death and extended cell cycle length, retinal progenitor cells persisted in Brg1-deficient retinae, making them more susceptible to retinoblastoma. In conclusion, ChIP-Seq analysis suggests that Brg1 might regulate gene expression through multiple mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Using spatial logic in classification of Landsat TM data

A strategy for spatial/spectral classification of Landsat TM data is presented. The strategy is founded upon 'spatial logic', a logic that seeks to emulate important aspects of visual image interpretation. The carefully structured classification process begins with spectral stratification of the data into water, vegetated and non-vegetated pixels. A region growing algorithm is then used to define 'fields' of similar land cover composition. Fields are characterized by cover composition, size and neighborhood characteristics. A supervised iterative contextual classification algorithm is developed to assign final land use/land cover labels. Maps are generalized using a spatial post-processing technique. Positive, though preliminary, results are presented.

Merchant, J. W.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Chemical vapor infiltration of additively manufactured preforms: Pore-resolved simulations and experimental validation

The densification of additively manufactured porous preforms by chemical vapor infiltration (CVI) is studied using pore-resolved simulations and experiments. Experimentally, 3D printed silicon carbide (SiC) preforms are subject to CVI synthesis using methyltrichlorosilane (MTS) precursor to obtain high purity SiC/SiC composites. Optical images of the cross sections of the processed preforms are analyzed to obtain the spatial porosity distribution. The numerical method is based on a level set formulation to capture the spatial distribution and time evolution of the pore scale microstructural characteristics. The coupled transport and kinetic effects are represented using a dimensionless Thiele modulus. Simulations are initialized using representative synthetic preform geometries comprising of packed particles based on the size distribution of the powder used for 3D printing. The simulation results are validated against the experimental observations in terms of total density and the distribution of residual porosity. The densification characteristics, porosity classification, concentration profiles, and structure functions are analyzed as functions of processing temperature and Thiele modulus.

36 MATERIALS SCIENCE↗

Time-Resolved Imaging of Material Response Following Laser-Induced Breakdown in the Bulk and Surface of Fused Silica

Optical components within high energy laser systems are susceptible to laser-induced material modification when the breakdown threshold is exceeded or damage is initiated by pre-existing impurities or defects. These modifications are the result of exposure to extreme conditions involving the generation of high temperatures and pressures and occur on a volumetric scale of the order of a few cubic microns. The response of the material following localized energy deposition, including the timeline of events and the individual processes involved during this timeline, is still largely unknown. In this work, we investigate the events taking place during the entire timeline in both bulk and surface damage in fused silica using a set of time-resolved microscopy systems. These microscope systems offer up to 1 micron spatial resolution when imaging static or dynamic effects, allowing for imaging of the entire process with adequate temporal and spatial resolution. These systems incorporate various pump-probe geometries designed to optimize the sensitivity for detecting individual aspects of the process such as the propagation of shock waves, near-surface material motion, the speed of ejecta, and material transformations. The experimental results indicate that the material response can be separated into distinct phases, some terminating within a few tens of nanoseconds but some extending up to about 100 microseconds. Overall the results demonstrate that the final characteristics of the modified region depend on the material response to the energy deposition and not on the laser parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating the Effects of Mixing Dynamics on Twin-Screw Granule Quality Attributes via the Development of a Physics-Based Process Map

Twin-screw granulation (TSG) is an emerging continuous wet granulation technique that has not been widely applied in the industry due to a poor mechanistic understanding of the process. This study focuses on improving this mechanistic understanding by analyzing the effects of the mixing dynamics on the granule quality attributes (PSD, content uniformity, and microstructure). Mixing is an important dynamic process that simultaneously occurs along with the granulation rate mechanisms during the wet granulation process. An improved mechanistic understanding was achieved by identifying and quantifying the physically relevant intermediate parameters that affect the mixing dynamics in TSG, and then their effects on the granule attributes were analyzed by investigating their effects on the granulation rate mechanisms. The fill level, granule liquid saturation, extent of nucleation, and powder wettability were found to be the key physically relevant intermediate parameters that affect the mixing inside the twin-screw granulator. An improved geometrical model for the fill level was developed and validated against existing experimental data. Finally, a process map was developed to depict the effects of mixing on the temporal and spatial evolution of the materials inside the twin-screw granulator. This process map illustrates the mechanism of nucleation and the growth of the granules based on the fundamental material properties of the primary powders (solubility and wettability), liquid binders (viscosity), and mixing dynamics present in the system. Furthermore, it was shown that the process map can be used to predict the granule product quality based on the granule growth mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-IeP3-10: Molecular Imaging with Clinical X-Ray Sources and Compton Cameras

Purpose: The application of Compton cameras (CC) is a novel approach translating XFCT to a practical modality realized with clinical CT systems without the restriction of pencil beams. The dual modality design offers additional information without extra patient dose. The purpose of this work is to investigate the feasibility and efficacy of using CCs for volumetric x-ray fluorescence (XF) imaging by Monte Carlo (MC) simulations and statistical image reconstruction. Methods: The feasibility of a CC for imaging x-ray fluorescence emitted from targeted lesions is examined by MC simulations. 3 mm diameter water spheres with various gold concentrations and detector distances are placed inside the lung of an adult human phantom (MIRD) and are irradiated with both fan and cone-beam geometries. A sandwich design CC composed of Silicon and CdTe is used to image the gold nanoparticle distribution. The detection system comprises four 16×26 cm{sup 2} detector panels placed on the chest of a MIRD phantom. Constraints of energy-, spatial-resolution, clinical geometries and Doppler broadening are taken into account. Image reconstruction is performed with a list-mode MLEM algorithm with cone-projector on a GPU. Results: The comparison of reconstruction of cone- and fan-beam excitation shows that the spatial resolution is improved by 23% for fan-beams with significantly decreased processing time. Cone-beam excitation increases scatter content disturbing quantification of lesions near the body surface. Spatial resolution and detectability limit in the center of the lung is 8.7 mm and 20 fM for 50 nm diameter gold nanoparticles at 20 mGy. Conclusion: The implementation of XFCT with a CC is a feasible method for molecular imaging with high atomic number probes. Given constrains of detector resolutions, Doppler broadening, and limited exposure dose, spatial resolutions comparable with PET and molecular sensitivities in the fM range are realizable with current detector technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic map interpretation in a dual-task context

The present experiment was designed to assess the extent to which spatial and verbal-analytic (VA) information processing resources are used in performing a simulated aircraft navigation task. Subjects were required to decide whether a 'match' or a mismatch' existed between a schematic 3D perspective forward field of view and a 2D top-down map. On dual-task trials, this navigation task was concurrently performed with either a VA side-task or with one of two tracking tasks. The data suggest that a VA strategy was most likely to be used when stimuli were simple or were mismatches, whereas a spatial mental rotation strategy was apparently used to confirm complex match stimuli. These results indicate that it may be possible to specify conditions wherein navigation is likely to compete for resources critical to other cockpit activities, such as aircraft control and communication.

Williams, Henry P.↗

First Results From A Multi-Ion Beam Lithography And Processing System At The University Of Florida

The University of Florida (UF) have collaborated with Raith to develop a version of the Raith ionLiNE IBL system that has the capability to deliver multi-ion species in addition to the Ga ions normally available. The UF system is currently equipped with a AuSi liquid metal alloy ion source (LMAIS) and ExB filter making it capable of delivering Au and Si ions and ion clusters for ion beam processing. Other LMAIS systems could be developed in the future to deliver other ion species. This system is capable of high performance ion beam lithography, sputter profiling, maskless ion implantation, ion beam mixing, and spatial and temporal ion beam assisted writing and processing over large areas (100 mm2)--all with selected ion species at voltages from 15-40 kV and nanometer precision. We discuss the performance of the system with the AuSi LMAIS source and ExB mass separator. We report on initial results from the basic system characterization, ion beam lithography, as well as for basic ion-solid interactions.

36 MATERIALS SCIENCE↗

Experimental study of the spatial distributions of relativistic electron beams reflected and refracted by a thin foil

Photographs of cross sections of an electron beam scattered from thin foils have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of particles both reflected from a foil and passed through it. The spatial distribution of electrons incident on aluminum, copper, and lead foils, as well as on bimetallic foils composed of aluminum and lead layers and of aluminum and copper layers, has been measured. The effect of the material and thickness of the foil, as well as of the angle between the initial beam trajectory and the target plane, on the spatial distribution of electrons has been studied. The effect of the sequence of the metal layers in bimetallic foils on the distribution of beams has been analyzed. A 7.4-MeV microtron has been used as a source of electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous-variable quantum computation with spatial degrees of freedom of photons

We discuss the use of the transverse spatial degrees of freedom of photons propagating in the paraxial approximation for continuous-variable information processing. Given the wide variety of linear optical devices available, a diverse range of operations can be performed on the spatial degrees of freedom of single photons. Here we show how to implement a set of continuous quantum logic gates which allow for universal quantum computation. In contrast with the usual quadratures of the electromagnetic field, the entire set of single-photon gates for spatial degrees of freedom does not require optical nonlinearity and, in principle, can be performed with a single device: the spatial light modulator. Nevertheless, nonlinear optical processes, such as four-wave mixing, are needed in the implementation of two-photon gates. The efficiency of these gates is at present very low; however, small-scale investigations of continuous-variable quantum computation are within the reach of current technology. In this regard, we show how novel cluster states for one-way quantum computing can be produced using spontaneous parametric down-conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using High Spatial Resolution Satellite Imagery to Map Forest Burn Severity Across Spatial Scales in a Pine Barrens Ecosystem

As a primary disturbance agent, fire significantly influences local processes and services of forest ecosystems. Although a variety of remote sensing based approaches have been developed and applied to Landsat mission imagery to infer burn severity at 30 m spatial resolution, forest burn severity have still been seldom assessed at fine spatial scales (less than or equal to 5 m) from very-high-resolution (VHR) data. We assessed a 432 ha forest fire that occurred in April 2012 on Long Island, New York, within the Pine Barrens region, a unique but imperiled fire-dependent ecosystem in the northeastern United States. The mapping of forest burn severity was explored here at fine spatial scales, for the first time using remotely sensed spectral indices and a set of Multiple Endmember Spectral Mixture Analysis (MESMA) fraction images from bi-temporal - pre- and post-fire event - WorldView-2 (WV-2) imagery at 2 m spatial resolution. We first evaluated our approach using 1 m by 1 m validation points at the sub-crown scale per severity class (i.e. unburned, low, moderate, and high severity) from the post-fire 0.10 m color aerial ortho-photos; then, we validated the burn severity mapping of geo-referenced dominant tree crowns (crown scale) and 15 m by 15 m fixed-area plots (inter-crown scale) with the post-fire 0.10 m aerial ortho-photos and measured crown information of twenty forest inventory plots. Our approach can accurately assess forest burn severity at the sub-crown (overall accuracy is 84% with a Kappa value of 0.77), crown (overall accuracy is 82% with a Kappa value of 0.76), and inter-crown scales (89% of the variation in estimated burn severity ratings (i.e. Geo-Composite Burn Index (CBI)). This work highlights that forest burn severity mapping from VHR data can capture heterogeneous fire patterns at fine spatial scales over the large spatial extents. This is important since most ecological processes associated with fire effects vary at the less than 30 m scale and VHR approaches could significantly advance our ability to characterize fire effects on forest ecosystems.

Meng, Ran↗

Ultrafast Imaging of Laser Driven Shock Waves using Betatron X-rays from a Laser Wakefield Accelerator

Abstract Betatron radiation from laser wakefield accelerators is an ultrashort pulsed source of hard, synchrotron-like x-ray radiation. It emanates from a centimetre scale plasma accelerator producing GeV level electron beams. In recent years betatron radiation has been developed as a unique source capable of producing high resolution x-ray images in compact geometries. However, until now, the short pulse nature of this radiation has not been exploited. This report details the first experiment to utilize betatron radiation to image a rapidly evolving phenomenon by using it to radiograph a laser driven shock wave in a silicon target. The spatial resolution of the image is comparable to what has been achieved in similar experiments at conventional synchrotron light sources. The intrinsic temporal resolution of betatron radiation is below 100 fs, indicating that significantly faster processes could be probed in future without compromising spatial resolution. Quantitative measurements of the shock velocity and material density were made from the radiographs recorded during shock compression and were consistent with the established shock response of silicon, as determined with traditional velocimetry approaches. This suggests that future compact betatron imaging beamlines could be useful in the imaging and diagnosis of high-energy-density physics experiments.

43 PARTICLE ACCELERATORS↗

Origin of the Short-Term Variations of the Cosmic Ray Flux

Detection of cosmic ray fluxes makes it possible to study dynamics of the interplanetary magnetic field and gain information about processes that occur both on the solar surface and in the entire Solar system. The main variations in the cosmic ray intensity are 27-day variations and Forbush effects. These variations are caused by complex spatial solar-plasma formations resulting from various processes on the solar surface and propagating in space with widely varying velocities. The data recorded by the PAMELA magnetic spectrometer on board the Resurs-DK1 satellite in 2006–2016 are used.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TPSAS-NF1676L-35172-DND

The wide field of view instrument on Earth Radiation Budget Experiment (ERBE) Earth Radiation Budget Satellite (ERBS) took measurements from November 1984 through September 1999. It provides top-of-atmosphere (TOA) reflected shortwave and emitted longwave irradiance at a 10 degree by 10 degree spatial resolution. We have recently re-processed ERBS wide field of view data with algorithms similar to those used in the CERES process (Shrestha et al. 2019). We also calibrated ERBS shortwave and longwave irradiance with CERES-derived irradiances. Combining ERBS and CERES data, we analyze the time series of global mean net TOA irradiance from 1985. The change of TOA net radiation over 30 years derived from ERBS and CERES data is larger than the change derived by Allan et al. (2014). The difference in the net irradiance change from two data sets is, however, within the uncertainty of ocean heating rates derived from ocean temperature measurements in 80?s. We also investigate the spatial distribution of changes in reflected shortwave irradiances derived from ERBS and CERES periods. The spatial distribution of reflected shortwave irradiance changes over the tropics and sub-tropical regions derived from our data set is qualitatively consistent with the result of Norris et al. (2016).

Antonio Viudez-Mora↗