Post-Combustion and Pre-Combustion CO2 Capture Solid Sorbents

Combustion of fossil fuels is one of the major sources of the greenhouse gas CO2. Pressure swing adsorption/sorption (PSA/PSS) and temperature swing adsorption/sorption (TSA/TSS) are some of the potential techniques that could be utilized for removal of CO2 from fuel gas streams. It is very important to develop sorbents to remove CO2 from fuel gas streams that are applicable for a wide range of temperatures. NETL researchers have developed novel CO2 capture sorbents for low, moderate, and high temperature applications. A novel liquid impregnated solid sorbent was developed for CO2 removal in the temperature range of ambient to 60 °C. The sorbent is regenerable at 60 – 80 °C. The sorbent formulations were prepared to be suitable for various reactor configurations (i.e., fixed and fluidized bed). Minimum fluidization gas velocities were also determined. Multi-cycle tests conducted in an atmospheric bench scale reactor with simulated flue gas indicated that the sorbent retains its CO2 sorption capacity with a CO2 removal efficiency of approximately 99% and was unaffected by presence of water vapor. The sorbent was subsequently commercially prepared by Süd Chemie to determine the viability of the sorbent for mass production. Subsequent testing showed that the commercially-synthesized sorbent possesses the same properties as the lab-synthesized equivalent. An innovative solid sorbent containing mixture of alkali earth and alkali compounds was developed for CO2 removal at 200 – 315°C from high pressure gas streams suitable for IGCC systems. The sorbent showed very high capacity for CO2 removal from a gas streams containing 28% CO2 at 200 °C and at 20 atm during a lab scale reactor test. This sorbent can be regenerated at 20 atm and at 375 °C utilizing a gas stream containing steam. High pressure enhanced the CO2 sorption process. Bench scale testing showed consistent capacities and regenerability. A unique high temperature solid sorbent was developed for CO2 capture at temperatures of 500 – 700°C. Bench scale testing of the sorbent yielded very high CO2 capture capacity from a gas stream containing 10% CO2, 30% H2, 15% H2O, and 25% He. Regeneration of the sorbent is possible at 800 – 900 °C.

01 COAL, LIGNITE, AND PEAT↗

Post-Combustion and Pre-Combustion CO2 Capture Solid Sorbents

Combustion of fossil fuels is one of the major sources of the greenhouse gas CO2. Pressure swing adsorption/sorption (PSA/PSS) and temperature swing adsorption/sorption (TSA/TSS) are some of the potential techniques that could be utilized for removal of CO2 from fuel gas streams. It is very important to develop sorbents to remove CO2 from fuel gas streams that are applicable for a wide range of temperatures. NETL researchers have developed novel CO2 capture sorbents for low, moderate, and high temperature applications. A novel liquid impregnated solid sorbent was developed for CO2 removal in the temperature range of ambient to 60 °C. The sorbent is regenerable at 60 – 80 °C. The sorbent formulations were prepared to be suitable for various reactor configurations (i.e., fixed and fluidized bed). Minimum fluidization gas velocities were also determined. Multi-cycle tests conducted in an atmospheric bench scale reactor with simulated flue gas indicated that the sorbent retains its CO2 sorption capacity with a CO2 removal efficiency of approximately 99% and was unaffected by presence of water vapor. The sorbent was subsequently commercially prepared by Süd Chemie to determine the viability of the sorbent for mass production. Subsequent testing showed that the commercially-synthesized sorbent possesses the same properties as the lab-synthesized equivalent. An innovative solid sorbent containing mixture of alkali earth and alkali compounds was developed for CO2 removal at 200 – 315°C from high pressure gas streams suitable for IGCC systems. The sorbent showed very high capacity for CO2 removal from a gas streams containing 28% CO2 at 200 °C and at 20 atm during a lab scale reactor test. This sorbent can be regenerated at 20 atm and at 375 °C utilizing a gas stream containing steam. High pressure enhanced the CO2 sorption process. Bench scale testing showed consistent capacities and regenerability. A unique high temperature solid sorbent was developed for CO2 capture at temperatures of 500 – 700°C. Bench scale testing of the sorbent yielded very high CO2 capture capacity from a gas stream containing 10% CO2, 30% H2, 15% H2O, and 25% He. Regeneration of the sorbent is possible at 800 – 900 °C.

COAL↗

National Energy Water Treatment & Speciation (NEWTS): A Water & Critical Mineral Database and Dashboard

The scarcity of water resources, the need for beneficial water reuse, and the challenges of wastewater treatment are becoming increasingly pressing in economic, social, and environmental domains. Addressing these concerns requires effective treatment strategies to manage wastewater streams and tackle environmental and economic issues. Furthermore, the recovery of critical minerals from the waste streams associated with energy production holds the promise of offsetting treatment costs and securing local sources of valuable minerals. However, relevant data on these waste streams are dispersed and challenging to locate. The process of ingesting such data into modeling software often involves multiple steps, requiring data restructuring to meet software-input requirements. The non-standardized reporting of water data makes data aggregation and reformatting a time-consuming process. Additionally, essential attributes necessary for modeling water treatment and mineral scale formation are frequently missing. Moreover, data gaps vary depending on the region of interest. Consequently, there is a pressing need for high-quality energy-water composition data that can be easily imported into water chemistry modeling software. To address this need, the National Energy Technology Laboratory has created the National Energy Water Treatment and Speciation (NEWTS) Database and Dashboard—a free online tool catering to community leaders and water researchers. NEWTS facilitates a comprehensive understanding of the composition of energy-related wastewater streams in the United States. The datasets provide detailed concentrations and speciation of major and minor aqueous compounds in energy-related wastewater streams, including power plant leachate, acid mine drainage, brackish water, and oil and gas produced water across the United States. Many of the aqueous species are critical minerals (Li, REEs) in high demand to modernize the world’s energy infrastructure. Many of the datasets also contain volumetric flow-rates needed to model the treatment and reuse scenarios in advanced aqueous chemistry software programs. The NEWTS Database and Dashboard offer public access to hitherto challenging-to-access datasets, presented in a standardized format that is tailored for easy input into aqueous chemistry modeling software. By performing the work needed to transform dispersed, disparate data sources into unified, model-ready datasets, NEWTS serves as an essential resource in advancing water treatment research and sustainable water resource management.

produced water management↗

Removal potential of toxic 2378-substituted PCDD/F from incinerator flue gases by waste-derived activated carbons

The application of activated carbons has become a commonly used emission control protocol for the removal or adsorption of persistent organic pollutants from the flue gas streams of waste incinerators. In this study, the 2378-substituted PCDD/F removal efficiency of three types of activated carbons derived from the pyrolysis of refuse derived fuel, textile waste and scrap tyre was investigated and compared with that of a commercial carbon. Experiments were carried out in a laboratory scale fixed-bed reactor under a simulated flue gas at 275 deg. C with a reaction period of four days. The PCDD/F in the solid matrices and exhaust gas, were analyzed using gas chromatography coupled with a triple quadrupole mass spectrometer. In the absence of activated carbon adsorbent, there was a significant increase in the concentration of toxic PCDD/F produced in the reacted flyash, reaching up to 6.6 times higher than in the raw flyash. In addition, there was a substantial release of PCDD/F into the gas phase, which was found in the flue gas trapping system. By application of the different commercial, refuse derived fuel, textile and tyre activated carbons the total PCDD/F toxic equivalent removal efficiencies in the exhaust gas stream were 58%, 57%, 64% and 52%, respectively. In general, the removal of the PCDDs was much higher with an average of 85% compared to PCDFs at 41%. Analysis of the reacted activated carbons showed that there was some formation of PCDD/F, for instance, a total of 60.6 {mu}g I-TEQ kg{sup -1} toxic PCDD/F was formed in the refuse derived fuel activated carbon compared to 34 {mu}g I-TEQ kg{sup -1} in the commercial activated carbon. The activated carbons derived from the pyrolysis of waste, therefore, showed good potential as a control material for PCDD/F emissions in waste incinerator flue gases.

54 ENVIRONMENTAL SCIENCES↗

Testing of Optimized Bubbler Configuration for HLW Melter

The principal objective of this work was to determine the glass production rate increase and ancillary effects of adding more bubbler outlets to the current WTP HLW melter baseline. This was accomplished through testing on the HLW Pilot Melter (DM1200) at VSL. The DM1200 unit was selected for these tests since it was used previously with several HLW waste streams including the four tank wastes proposed for initial processing at Hanford. This melter system was also used for the development and optimization of the present baseline WTP HLW bubbler configuration for the WTP HLW melter, as well as for MACT testing for both HLW and LAW. Specific objectives of these tests were to: Conduct DM1200 melter testing with the baseline WTP bubbling configuration and as augmented with additional bubblers. Conduct DM1200 melter testing to differentiate the effects of total bubbler air flow and bubbler distribution on glass production rate and cold cap formation. Collect melter operating data including processing rate, temperatures at a variety of locations within the melter plenum space, melt pool temperature, glass melt density, and melter pressure with the baseline WTP bubbling configuration and as augmented with additional bubblers. Collect melter exhaust samples to compare particulate carryover for different bubbler configurations. Analyze all collected data to determine the effects of adding more bubblers to the WTP HLW melter to inform decisions regarding future lid re-designs. The work used a high aluminum HLW stream composition defined by ORP, for which an appropriate simulant and high waste loading glass formulation were developed and have been previously processed on the DM1200.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control of Radioactive Methyl Iodide Gases by Mesoporous Hybrid Adsorbents at High Humid Condition - 19329

During the operation of nuclear facility as well as decommissioning stage, various radioactive gaseous wastes are generated. It is generally recognized that radioiodine is potentially one of the most hazardous gas on the human body and environment. Iodine-131 release in the gaseous effluents at the nuclear facilities had been a critical environmental concern. Reducing iodine release is a critical issue in radioactive waste system evaluation, especially in their adherence to the 'as low as reasonably achievable' (ALARA) criteria because radioiodine among these gaseous wastes has radiological harm. Therefore, numerous studies for the removal of radioiodine from the off-gas stream of nuclear facilities have been performed with formation processes and chemical structure. There has been some concern regarding the use of TEDA-impregnated activated carbon as an adsorbent for radioiodine removal, because of the low ignition point of TEDA and the possible release of TEDA from the charcoal in continuously flowing air streams. Therefore, the TEDA-impregnated activated carbon cannot use to trap radioiodine generated from high humid condition, due to the rapid drop of the removal efficiency. It is obvious that high humid can be expected during design basis event such as loss-of-coolant accident (LOCA). Therefore, investigation on the retention of organic radioiodine (CH3I131) by various activated carbons at high humid condition has extensively been performed so far. But there are no good results on the adsorption of methyl iodide at high humid condition up to now. As a result, the promising approach to the problem of iodine removal under high humid conditions is to use organic-inorganic hybrid adsorbents in which are enough retention characteristics from hydrophobic property. In order to develop the best removal efficiency for the control of radioiodine gas generated from a high humid process, a hydrophobic adsorbents was developed and the performance test of adsorbent using radioactive methyl iodide tracer was also performed. Demonstration test of adsorbent using radioactive methyl iodide tracer was performed at high humid conditions up to 97% relative humidity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Evaluation of Side Stream Filtration for Cooling Towers

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. Cooling towers represent the point in a cooling system where heat is dissipated to the atmosphere through evaporation. Cooling towers are commonly used in industrial applications and in large commercial buildings to release waste heat extracted from a process or building system through evaporation of water.

Technical, Evaluation, Side-Stream, Filtration, Co↗

The influence of state-to-state kinetics on diffusion and heat transfer behind shock waves

In the paper, the influence of vibrational and chemical kinetics on heat transfer and diffusion in hypersonic flows of N{sub 2}/N mixture in the relaxation zone behind shock waves is studied on the basis of the state-to-state kinetic theory approach. The results of calculations of vibrational level populations ni, gas temperature T, total energy flux q, diffusion velocities of molecules at different vibrational states V{sub i} and atoms V{sub a} in the relaxation zone behind a shock front are presented for the free stream Mach number M = 10, 15. The contribution of different dissipative processes to the total energy flux is estimated for various flow conditions. The impact of non-equilibrium vibrational distributions in the free stream on molecular level populations and transport properties in the relaxation zone is shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cadarache LOR (liquides organiques radioactifs) treatment by a solidification process using NOCHAR polymers

In France, two options can be considered to handle the Very Low Level Waste (VLLW) and the Low Level Waste (LLW). The first one is the incineration at CENTRACO facility and the second one is the disposal at ANDRA sites. The waste acceptance in these two channels is dependent upon the adequacy between the waste characteristics (physical chemistry and radiological) and the channel specifications. If the waste characteristics and the channel specifications (presence of significant quantities of halogens, complexing agents, organic components... or/and high activity limits) are incompatible, an alternative solution have to be identify. It consists of a waste pre-treatment process. For Cadarache LOR (Liquides Organiques Radioactifs) waste streams, two radioactive scintillation cocktails have to be treated. They are composed of a mix of organic liquids and water: for the first one, 19 % of organic compounds (xylene, mesitylene, diphenyloxazole, TBP...) and 86.9 % of water, and for the second one, 23 % of organic compounds (TBP...) and 77 % of water. They contain halogens (chlorine and fluorine), complexants agents (nitrate, sulphate, oxalate and formate) and have got αβγ spectra with mass activities equal to some 100 Bq/g. Therefore, tritium is also present. As a consequence, in order for storage acceptance at the ANDRA site, it is necessary to pre-treat the waste. An adequate solution seems to be a solidification process using NOCHAR polymers. Indeed, NOCHAR polymers correspond to an important variety of products applied to the treatment of radioactive aqueous and organic liquids (solvent, oil, solvent/oil mixing ...) and sludge through a mechanical and chemical solidification process. For Cadarache LOR, N910 and N960 respectively dedicated to the organic and aqueous liquids solidification are considered. With the N910, the organic waste solidification occurs in two steps. As the organic liquid travels moves through the polymer strands, the strands swell and immobilize the liquid. Then as the polymer-organic cure, over time, the polymer continues to collapse on the organic to create a permanent chemical bond. The N960 has the ability to absorb aqueous waste up to 100 times its own weight. It creates a strong mechanical bond which permanently traps the contamination imbedded in the aqueous liquids. Therefore, these two NOCHAR polymers seem to be able to constitute a suitable solidification matrix for a final acceptance in storage on ANDRA sites. In order to validate the solidification process using NOCHAR polymers as an acceptable solution for Cadarache LOR treatment, some solidification tests realised with N910 and N960, have been carried out for different Waste/Polymer ratios. To determine the best Waste/Polymer ratio and the optimal experimental parameters, exudation tests have been made. Indeed, the process prevents leaching and it results in the absence residual free organic or aqueous liquid which is forbidden in storage by ANDRA specifications. With these results, the obtained scientific data constitute a fundamental basis of an ANDRA agreement. As a conclusion, the aim of this study is to demonstrate that the pre-treatment by solidification using NOCHAR polymers can constitute a solution for Cadarache LOR handling and more generally, for various organic and mixed organic/aqueous waste which can not be directly acceptable at CENTRACO facility or at ANDRA storage sites. So then, this study is a solid background to demonstrate the feasibility of the waste pre-treatment by solidification with NOCHAR polymer and to encourage this process development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal control to handle variations in moisture content and reactor in-feed rate

The variations in feedstock characteristics, such as moisture and particle size distribution, lead to an inconsistent flow of feedstock from the biomass pre-processing system to the reactor in-feed system. These inconsistencies result in low on-stream times at the reactor in-feed equipment. This research develops an optimal process control method for a biomass pre-processing system comprised of milling and densification operations to provide the consistent flow of feedstock to a reactor's throat. This method uses a mixed-integer optimization model to identify optimal bale sequencing, equipment in-feed rate, and buffer location and size in the biomass pre-processing system. This method, referred to as the hybrid process control (HPC), aims to maximize throughput over time. We compare HPC with a baseline feed forward process control. Our case study based on switchgrass finds that HPC reduces the variation of a reactor's feeding rate by up to 100% without increasing the operating cost of the biomass pre-processing system for biomass with moisture ranging from 10 to 25%. Additionally, HPC reduces the cost of processing biomass by 0.36%–2.22%, and reduces processing time by 0.35%-2.24%. Furthermore, a biorefinery can adapt HPC to achieve its design capacity.

09 BIOMASS FUELS↗

RESULTS FOR THE SECOND QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, the DDA (Deliquification, Dissolution, and Adjustment) process, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are listed in the current Saltstone WAC. Waste Solidification Engineering (WSE) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2011 Second Quarter samples collected from Tank 50 on April 4, 2011 and discusses those results in further detail than the previously issued results report. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for {sup 59}Ni is above the requested limit from Reference 2 but below the established limit in Reference 3. (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. (4) The reported concentration of {sup 242m}Am is above the target in Listed in Attachment 8.4 of the Saltstone WAC. (5) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3. (6) The reported detection limit for Norpar 13{sup 5} is greater than the limit from Table 4 and Attachment 8.2 of the WAC. (7) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (8) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a statistical model (tool) for classifying buried object detectability

To improve warfighter safety under changing requirements, assets must be adaptable and able to detect and mark buried hazards. Current GPR systems would benefit by improvements in speed, usability, and operational versatility to enhance operational effectiveness for all platforms and missions. Our sponsor requests that LLNL research GPR methodologies and approaches to allow for specific improvements to be made in those areas. MiRadar uses a novel multi-static array architecture coupled with tomographic processing to focus returned energy from the real (physical) and synthetic (motion-derived) apertures. 3D streaming movies of the subsurface are easily interpreted, slashing training times. Real-time processing codes enable imaging and operation three times faster; automated volumetric detection algorithms warn of possible hazards. In a two-week trial, multiple vehicle-mounted arrays and a new ultralightweight architecture on a small, unmanned aircraft system executed 498 runs, collecting over 400km of data on 13 preemplaced lanes containing 384 simulated buried threats.

42 ENGINEERING↗

RESULTS FOR THE FOURTH QUARTER TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, the DDA (Deliquification, Dissolution, and Adjustment) process, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are listed in the current Saltstone WAC. SRS Liquid Waste Operations (LWO) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2009 Fourth Quarter samples collected from Tank 50 on October 2, 2009 and discusses those results in further detail than the previously issued results report. This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (3) The reported detection limits for {sup 59}Ni and {sup 94}Nb are above the requested limits from Reference 4. However, they are each below the limits established in Reference 3. (4) The reported detection limit for isopropanol is greater than the requested limit from Table 4 of the WAC. (5) The reported detection limits for {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of BOC'S Lotox Process for the Oxidation of Elemental Mercury in Flue Gas from a Coal-Fired Boiler

Linde's Low Temperature Oxidation (LoTOx{trademark}) process has been demonstrated successfully to remove more than 90% of the NOx emitted from coal-fired boilers. Preliminary findings have shown that the LoTOx{trademark} process can be as effective for mercury emissions control as well. In the LoTOx{trademark} system, ozone is injected into a reaction duct, where NO and NO{sub 2} in the flue gas are selectively oxidized at relatively low temperatures and converted to higher nitrogen oxides, which are highly water soluble. Elemental mercury in the flue gas also reacts with ozone to form oxidized mercury, which unlike elemental mercury is water-soluble. Nitrogen oxides and oxidized mercury in the reaction duct and residual ozone, if any, are effectively removed in a wet scrubber. Thus, LoTOx{trademark} appears to be a viable technology for multi-pollutant emission control. To prove the feasibility of mercury oxidation with ozone in support of marketing LoTOx{trademark} for multi-pollutant emission control, Linde has performed a series of bench-scale tests with simulated flue gas streams. However, in order to enable Linde to evaluate the performance of the process with a flue gas stream that is more representative of a coal-fired boiler; one of Linde's bench-scale LoTOx{trademark} units was installed at WRI's combustion test facility (CTF), where a slipstream of flue gas from the CTF was treated. The degree of mercury and NOx oxidation taking place in the LoTOx{trademark} unit was quantified as a function of ozone injection rates, reactor temperatures, residence time, and ranks of coals. The overall conclusions from these tests are: (1) over 80% reduction in elemental mercury and over 90% reduction of NOx can be achieved with an O{sub 3}/NO{sub X} molar ratio of less than two, (2) in most of the cases, a lower reactor temperature is preferred over a higher temperature due to ozone dissociation, however, the combination of both low residence time and high temperature proved to be effective in the oxidation of both NOx and elemental mercury, and (3) higher residence time, lower temperature, and higher molar ratio of O{sub 3}/NOx contributed to the highest elemental mercury and NOx reductions.

01 COAL, LIGNITE, AND PEAT↗

Iterative Strategies for Aftershock Classification in Automatic Seismic Processing Pipelines

We report aftershock sequences following very large earthquakes present enormous challenges to near-real-time generation of seismic bulletins. The increase in analyst resources needed to relocate an inflated number of events is compounded by failures of phase-association algorithms and a significant deterioration in the quality of underlying, fully automatic event bulletins. Current processing pipelines were designed a generation ago, and, due to computational limitations of the time, are usually limited to single passes over the raw data. With current processing capability, multiple passes over the data are feasible. Processing the raw data at each station currently generates parametric data streams that are then scanned by a phase-association algorithm to form event hypotheses. We consider the scenario in which a large earthquake has occurred and propose to define a region of likely aftershock activity in which events are detected and accurately located, using a separate specially targeted semiautomatic process. This effort may focus on so-called pattern detectors, but here we demonstrate a more general grid-search algorithm that may cover wider source regions without requiring waveform similarity. Given many well-located aftershocks within our source region, we may remove all associated phases from the original detection lists prior to a new iteration of the phase-association algorithm. We provide a proof-of-concept example for the 2015 Gorkha sequence, Nepal, recorded on seismic arrays of the International Monitoring System. Even with very conservative conditions for defining event hypotheses within the aftershock source region, we can automatically remove about half of the original detections that could have been generated by Nepal earthquakes and reduce the likelihood of false associations and spurious event hypotheses. Lastly, further reductions in the number of detections in the parametric data streams are likely, using correlation and subspace detectors and/or empirical matched field processing.

58 GEOSCIENCES↗

Text-based Analytics for Biosurveillance

The ability to prevent, mitigate, or control a biological threat depends on how quickly the threat is identified and characterized. Ensuring the timely delivery of data and analytics is an essential aspect of providing adequate situational awareness in the face of a disease outbreak. This chapter outlines an analytic pipeline for supporting an advanced early warning system that can integrate multiple data sources and provide situational awareness of potential and occurring disease situations. The pipeline, includes real-time automated data analysis founded on natural language processing (NLP), semantic concept matching, and machine learning techniques, to enrich content with metadata related to biosurveillance. Online news articles are presented as an example use case for the pipeline, but the processes can be generalized to any textual data. In this chapter, the mechanics of a streaming pipeline are briefly discussed as well as the major steps required to provide targeted situational awareness. The text-based analytic pipeline includes various processing steps as well as identifying article relevance to biosurveillance (e.g., relevance algorithm) and article feature extraction (who, what, where, why, how, and when). The ability to prevent, mitigate, or control a biological threat depends on how quickly the threat is identified and characterized. Ensuring the timely delivery of data and analytics is an essential aspect of providing adequate situational awareness in the face of a disease outbreak. This chapter outlines an analytic pipeline for supporting an advanced early warning system that can integrate multiple data sources and provide situational awareness of potential and occurring disease situations. The pipeline, includes real-time automated data analysis founded on natural language processing (NLP), semantic concept matching, and machine learning techniques, to enrich content with metadata related to biosurveillance. Online news articles are presented as an example use case for the pipeline, but the processes can be generalized to any textual data. In this chapter, the mechanics of a streaming pipeline are briefly discussed as well as the major steps required to provide targeted situational awareness. The text-based analytic pipeline includes various processing steps as well as identifying article relevance to biosurveillance (e.g., relevance algorithm) and article feature extraction (who, what, where, why, how, and when).

Biomedical NLP↗

Fast shared-memory streaming multilevel graph partitioning

In this report we show that a fast parallel graph partitioner can benefit many applications by reducing data transfers. The online methods for partitioning graphs have to be fast and they often rely on simple one-pass streaming algorithms, while the offline methods for partitioning graphs contain more involved algorithms and the most successful methods in this category belong to the multilevel approaches. In this work, we assess the feasibility of using streaming graph partitioning algorithms within the multilevel framework. Our end goal is to come up with a fast parallel offline multilevel partitioner that can produce competitive cutsize quality. We rely on a simple but fast and flexible streaming algorithm throughout the entire multilevel framework. This streaming algorithm serves multiple purposes in the partitioning process: a clustering algorithm in the coarsening, an effective algorithm for the initial partitioning, and a fast refinement algorithm in the uncoarsening. Its simple nature also lends itself easily for parallelization. The experiments on various graphs show that our approach is on the average up to 5.1x faster than the multi-threaded MeTiS, which comes at the expense of only 2x worse cutsize.

97 MATHEMATICS AND COMPUTING↗

Processing and disposition of remote-handled transuranic liquid waste generated at Oak Ridge National Laboratory - 15113

Oak Ridge National Laboratory (ORNL) produces transuranic (TRU) isotopes for the US Department of Energy's (US DoE's) heavy-element research program and other programs for medical and industrial applications. As a result, the research facilities generate remote-handled TRU liquid low-level waste (LLLW). This LLLW is presently collected and mixed with larger volumes of legacy and environmental management waste streams for future treatment. Once the legacy waste is disposed of as part of the US DOE Environmental Management program, the large-scale waste treatment processes will be decommissioned, and new capabilities will be needed to characterize, treat, package, and dispose of the newly generated LLLW at ORNL. Various approaches are being considered for addressing treatment and disposal of the future LLLW streams. A variety of processing methods and final waste forms is under consideration. The impacts of the chemical and radionuclide compositions of the waste stream are being evaluated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗