Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A prototype fan-beam optical CT scanner for 3D dosimetry

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decoherence suppression combining quantum uncollapsing and dynamical decoupling

We demonstrate a protocol, that combines quantum uncollapsing and dynamical decoupling, to protect the quantum state stored in a qubit against decoherence errors. The protocol can simultaneously suppress the two kinds of decoherence processes: the energy relaxation and the low-frequency noise induced dephasing. We present the analytical derivation and numerical simulations in detail. We also provide a preliminary experimental test in superconducting phase qubits, using the process fidelity to calibrate the performance of the protocol. Our results suggest that the protocol can be effective against errors due to both energy relaxation and the low-frequency dephasing noise, except at a reduced probability of success.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MS Non-Pharmacological Countermeasure to Decrease Landing Sickness and Improve Functional Performance While Disorientad

Upon return from spaceflight, a majority of crewmembers experience motion sickness (MS) symptoms. The interactions between crewmembers' adaptation to a gravitational transition, the performance decrements resulting from MS and/or use of promethazine (PMZ), and the constraints imposed by mission task demands could significantly challenge and limit an astronaut's ability to perform functional tasks during gravitational transitions. No operational countermeasure currently exists to mitigate the risks associated with these sensorimotor disturbances. Stochastic resonance (SR) can be thought of simply as "noise benefit" or an increase in information transfer by a system when in the presence of a non-zero level of noise. We have shown that low levels of stochastic vestibular stimulation (SVS) improve balance and locomotor performance due to SR (Goel et al. 2015, Mulavara et al. 2011, 2015). Additionally, a study in a 6-hydroxydopamine (6-OHDA) hemi-lesioned rat model of Parkinson's disease demonstrated improvements in locomotor activity after low-level SVS delivery possibly due to an increase in nigral gamma-aminobutyric acid (GABA) release in a dopamine independent way (Samoudi et al. 2012). SVS specifically increased GABA release on the lesioned, but not the intact side. These results suggest that SVS can cause targeted alterations of GABA release to affect performance of functional tasks. Activation of the GABA pathway is important in modulating MS and promoting adaptability (Cohen 2008). Magnusson et al. (2000) supported this finding by showing that the administration of a GABAB agonist caused a reversal of the symptoms that is normally seen after unilateral labyrinthectomy. Thus, GABA could play a significant role in reducing MS and promoting adaptability. We have taken advantage of the SR mechanism as a modulator of neurotransmitters to develop a unique SVS countermeasure system to mitigate MS symptoms and improve functional performance after landing. Healthy subjects (n=20) participated in two test sessions, one in which they received +/-400 microA of SVS and one where they received no stimulation (0 microA); the study design was counterbalanced. Subjects began by performing a series of four functional tasks 3-5 times as baseline measurements of task performance. Then, to induce MS, subjects walked an obstacle course with up-down reversing prisms. If they completed the course before achieving our pre-determined level of MS, they were asked to read a poster while making large up-down head movements to a metronome while still wearing the reversing prism goggles. Subjects were stopped every two minutes and asked to report their MS symptoms. Using the Pensacola Scale for motion sickness, test operators evaluated the level of MS of each subject. Once a subject reached an 8 on this scale, which is equivalent to mild malaise, or 30 minutes had passed since the start of the MS induction, this protocol was stopped. Finally, immediately after MS induction, subjects were asked to complete the four functional tasks again. Although, 100% of our subjects experienced at least one MS symptom, only 55% of our subjects experienced stomach awareness to any degree. Without SVS, only 40% of subjects lasted the full 30-minute MS induction protocol, while 65% of subjects lasted the full 30 minutes with SVS, which is nearly a significant increase (p=0.056). In addition, subjects showed significant improvement from baseline when performing a tandem walk and a prone-to-stand test immediately after the MS induction protocol was stopped but the stimulation level was continued. The results are promising and future work includes comparing MS progression between PMZ and SVS directly in subjects that are provoked to a minimum of nausea. Low levels of SVS stimulation may serve as a non-pharmacological countermeasure to replace or reduce the PMZ dosage requirements and concurrently improve functional performance during transitions to new gravitational environments after spaceflight.

Rosenberg, M. J. F.↗

Optical Abelian lattice gauge theories

We discuss a general framework for the realization of a family of Abelian lattice gauge theories, i.e., link models or gauge magnets, in optical lattices. We analyze the properties of these models that make them suitable for quantum simulations. Within this class, we study in detail the phases of a U(1)-invariant lattice gauge theory in 2+1 dimensions, originally proposed by P. Orland. By using exact diagonalization, we extract the low-energy states for small lattices, up to 4 Multiplication-Sign 4. We confirm that the model has two phases, with the confined entangled one characterized by strings wrapping around the whole lattice. We explain how to study larger lattices by using either tensor network techniques or digital quantum simulations with Rydberg atoms loaded in optical lattices, where we discuss in detail a protocol for the preparation of the ground-state. We propose two key experimental tests that can be used as smoking gun of the proper implementation of a gauge theory in optical lattices. These tests consist in verifying the absence of spontaneous (gauge) symmetry breaking of the ground-state and the presence of charge confinement. We also comment on the relation between standard compact U(1) lattice gauge theory and the model considered in this paper. - Highlights: Black-Right-Pointing-Pointer We study the quantum simulation of dynamical gauge theories in optical lattices. Black-Right-Pointing-Pointer We focus on digital simulation of abelian lattice gauge theory. Black-Right-Pointing-Pointer We rediscover and discuss the puzzling phase diagram of gauge magnets. Black-Right-Pointing-Pointer We detail the protocol for time evolution and ground-state preparation in any phase. Black-Right-Pointing-Pointer We provide two experimental tests to validate gauge theory quantum simulators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Exploration-class missions beyond the Van Allen belt to the Moon and then Mars will begin soon. Low-Earth orbital spaceflight results in the persistent perturbation of the human immune system, characterized by reductions in T and NK cell function, altered cytokine profiles, and the reactivation of latent herpesviruses. While these alterations have not caused widespread clinical issues, some crewmembers experience immune-related adverse events, including manifestations of symptomatic herpes viral reactivation, allergy, and respiratory distress. Because future deep-space exploration missions will be of unprecedented duration, it is reasonable to hypothesize that the immune perturbations observed aboard International Space Station (ISS) will intensify during longer missions in deep space, thereby placing crewmembers at elevated clinical risk. Thus, it is imperative to preserve the immune vigilance of astronauts by developing a countermeasure strategy. Of all the Earth analogs studied to date, an Antarctica winter-over (AWO) mission most closely reproduces the spaceflight experience: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. Thus, it was hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was chosen as the platform for testing and validating the effectiveness of a NASA multi-system countermeasures protocol designed for deep space missions. The array of countermeasure protocols and monitoring methods deployed for each AWO will consist of diet modifications, nutritional supplementation, prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. With the completion of the Antarctica Winter-Over (WO) 2022 control year, samples for 13 subjects have been successfully returned from Antarctica to NASA/JSC for further processing and distribution to Co-Investigators. WO 2023, the first countermeasure year, has also commenced with 11 subject consenting and performing their base line data collections (BDC) held in Chile. Another 5 subjects, who were already stationed at Palmer Station, Antarctica, joined as participates in the investigation. These 5 subjects were consented, but no BDC was able to be collected due to their joining in-mission. Therefore, there will be a total of 16 subjects participating in Antarctica's 2023 Winter-Over.

Cody L Gutierrez↗

Outcome analysis of individualized vestibular rehabilitation protocols

OBJECTIVE: To determine the outcome of vestibular rehabilitation protocols in subjects with peripheral vestibular disorders compared with normal and abnormal control subjects. STUDY DESIGN: Prospective study using repeated measure, matched control design. Subjects were solicited consecutively according to these criteria: vestibular disorder subjects who had abnormal results of computerized dynamic posturography (CDP) sensory organization tests (SOTs) 5 and 6 and underwent rehabilitation; vestibular disorder subjects who had abnormal results of SOTs 5 and 6 and did not undergo rehabilitation; and normal subjects (normal SOTs). SETTING: Tertiary neurotology clinic. SUBJECTS: Men and women over age 18 with chronic vestibular disorders and chief complaints of unsteadiness, imbalance, and/or motion intolerance, and normal subjects. INTERVENTIONS: Pre- and post-rehabilitation assessment included CDP, vestibular disability, and activities of daily living questionnaires. Individualized rehabilitation plans were designed and implemented to address the subject's specific complaints and functional deficits. Supervised sessions were held at weekly intervals, and self-administered programs were devised for daily home use. MAIN OUTCOME MEASURES: CDP composite and SOT scores, number of falls on CDP, and self-assessment questionnaire results. RESULTS: Subjects who underwent rehabilitation (Group A) showed statistically significant improvements in SOTs, overall composite score, and reduction in falls compared with abnormal (Group B) control groups. Group A's performances after rehabilitation were not significantly different from those of normal subjects (Group C) in SOTs 3 through 6, and close to normal on SOTs 1 and 2. Subjects in Group A also reported statistically significant symptomatic improvement. CONCLUSIONS: Outcome measures of vestibular protocol physical therapy confirmed objective and subjective improvement in subjects with chronic peripheral vestibular disorders. These findings support results reported by other investigators.

NASA Discipline Neuroscience↗

Leaf water potential measurements using the pressure chamber: Synthetic testing of assumptions towards best practices for precision and accuracy

Leaf water potential (ψ leaf ), typically measured using the pressure chamber, is the most important metric of plant water status, providing high theoretical value and information content for multiple applications in quantifying critical physiological processes including drought responses. Pressure chamber measurements of ψ leaf (ψ leafPC ) are most typical, yet, the practical complexity of the technique and of the underlying theory has led to ambiguous understanding of the conditions to optimize measurements. Consequently, specific techniques and precautions diversified across the global research community, raising questions of reliability and repeatability. Here, we surveyed specific methods of ψ leafPC from multiple laboratories, and synthesized experiments testing common assumptions and practices in ψ leafPC for diverse species: (i) the need for equilibration of previously transpiring leaves; (ii) leaf storage before measurement; (iii) the equilibration of ψ leaf for leaves on bagged branches of a range of dehydration; (iv) the equilibration of ψ leaf across the lamina for bagged leaves, and the accuracy of measuring leaves with artificially ‘elongated petioles’; (v) the need in ψ leaf measurements for bagging leaves and high humidity within the chamber; (vi) the need to avoid liquid water on leaf surfaces; (vii) the use of ‘pulse’ pressurization versus gradual pressurization; and (viii) variation among experimenters in ψ leafPC determination. Based on our findings we provide a best practice protocol to maximise accuracy, and provide recommendations for ongoing species-specific tests of important assumptions in future studies.

54 ENVIRONMENTAL SCIENCES↗

Integrated RF/Optical Interplanetary Networking Preliminary Explorations and Empirical Results

Over the last decade interplanetary telecommunication capabilities have been significantly expanded--specifically in support of the Mars exploration rover and lander missions. NASA is continuing to drive advances in new, high payoff optical communications technologies to enhance the network to Gbps performance from Mars, and the transition from technology demonstration to operational system is examined through a hybrid RF/optical approach. Such a system combines the best features of RF and optical communications considering availability and performance to realize a dual band trunk line operating within characteristic constraints. Disconnection due to planetary obscuration and solar conjunction, link delays, timing, ground terminal mission congestion and scheduling policy along with space and atmospheric weather disruptions all imply the need for network protocol solutions to ultimately manage the physical layer in a transparent manner to the end user. Delay Tolerant Networking (DTN) is an approach under evaluation which addresses these challenges. A multi-hop multi-path hybrid RF and optical test bed has been constructed to emulate the integrated deep space network and to support protocol and hardware refinement. Initial experimental results characterize several of these challenges and evaluate the effectiveness of DTN as a solution to mitigate them.

Raible, Daniel E.↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Adjusting the Energy Profile for CH–O Interactions Leads to Improved Stability of RNA Stem-Loop Structures in MD Simulations

The role of ribonucleic acid (RNA) in biology continues to grow, but insight into important aspects of RNA behavior is lacking, such as dynamic structural ensembles in different environments, how flexibility is coupled to function, and how function might be modulated by small molecule binding. In the case of proteins, much progress in these areas has been made by complementing experiments with atomistic simulations, but RNA simulation methods and force fields are less mature. It remains challenging to generate stable RNA simulations, even for small systems where well-defined, thermostable structures have been established by experiments. Further many different aspects of RNA energetics have been adjusted in force fields, seeking improvements that are transferable across a variety of RNA structural motifs. In this work, the role of weak CH···O interactions is explored, which are ubiquitous in RNA structure but have received less attention in RNA force field development. By comparing data extracted from high-resolution RNA crystal structures to energy profiles from quantum mechanics and force field calculations, it is shown that CH···O interactions are overly repulsive in the widely used Amber RNA force fields. A simple, targeted adjustment of CH···O repulsion that leaves the remainder of the force field unchanged was developed. Then, the standard and modified force fields were tested using molecular dynamics (MD) simulations with explicit water and salt, amassing over 300 μs of data for multiple RNA systems containing important features such as the presence of loops, base stacking interactions as well as canonical and noncanonical base pairing. In this work and others, standard force fields lead to reproducible unfolding of the NMR-based structures. Including a targeted CH···O adjustment in an otherwise identical protocol dramatically improves the outcome, leading to stable simulations for all RNA systems tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-I-65: The Joint Commission's Requirements for Annual Diagnostic Physics Testing of Nuclear Medicine Equipment, and a Clinically Relevant Methodology for Testing Low-Contrast Resolution

Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisition protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U.S. Navy Wave Energy Test Site – Project Overview and Early Research

U.S. Marine Corps Base Hawaii, Kaneohe: 30m, 60m, 80m berths in place, grid-connected. First 2 devices deployed, more coming. HNEI role: Acoustic, EMF, ecological, sediment transport measurements. Independent device durability and performance analysis. Site-dedicated support vessel/maintenance protocol development.

16 TIDAL AND WAVE POWER↗

Perfusion Angiography of the Foot in Patients with Critical Limb Ischemia: Description of the Technique

ObjectiveTo study the feasibility of 2D perfusion imaging in critical limb ischemia (CLI).Methods/ResultsPerfusion angiography is a new technology which was tested in 18 patients with CLI of the foot. A standardized protocol was used with a catheter placed at the mid-part of the popliteal artery, and a total of 9 cc of non-ionic iodinated contrast material was injected at a rate of 3 cc/sec. The technology is based on early cardiology research where iodinated contrast agents were used for imaging of cardiac perfusion. During the first pass of the contrast, there is a significant diffusion of the contrast agents into the interstitial space, particularly for non-ionic and low-molecular-weight compounds.DiscussionThe original angiography data can be used to make a time–density curve, which represents the actual perfusion of the foot in time. Angiographic perfusion imaging is a post-processing modality for which no extra contrast or radiation is needed. With this technique, it is possible to get more information about the perfusion status and microcirculation of the foot. This is a step toward functional imaging in CLI patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Degradation of transparent conductive oxides: Interfacial engineering and mechanistic insights

Transparent conductive oxides (TCOs) are a known failure mode in a variety of thin film photovoltaic (PV) devices, through mechanisms such as resistivity increase and delamination. Degradation science studies of these materials, as well as most PV systems, have primarily utilized industry standard qualification protocols, which are not designed to be used as lifetime prediction tests. Here, this work applies a data science approach to this engineering challenge, utilizing commercially available TCOs and subjecting them to an array of stressors, including environmental and material stressors. Optical, electrical and surface sensitive TCO property metrics were monitored and analyzed en mass. Different degradation mechanisms and modes were observed when different stressor combinations were applied; TCO surfaces are sensitive to the proportion of water and light in an exposure, yellowing of the TCO only occurs when humidity and UV light are combined, and PEDOT:PSS (poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate)) application results in hazing and roughening of aluminum-doped zinc oxide (AZO). Using multi-variate analytics and plotting critical material properties against one another in a mechanistic plot, trade-offs between properties and the activation of different degradation mechanisms become readily apparent. In addition to a survey of failure modes of TCOs, a possible solution to the degradation of AZO was examined: the application of an organofunctional silane layer. The application of a thin APTES (3-aminopropyltriethoxysilane) film nearly eliminated the observed edge effects and greatly reduced the resistivity increase caused by damp heat exposure of AZO.

14 SOLAR ENERGY↗

The validation of an invitro colonic motility assay as a biomarker for gastrointestinal adverse drug reactions

Motility-related gastrointestinal adverse drug reactions (GADRs), such as constipation and diarrhea, are some of the most frequently reported adverse events associated with the clinical development of new chemical entities, and for marketed drugs. However, biomarkers capable of detecting such GADRs are lacking. Here, we describe an in vitro assay developed to detect and quantify changes in intestinal motility as a surrogate biomarker for constipation/diarrhea-type GADRs. In vitro recordings of intraluminal pressure were used to monitor the presence of colonic peristaltic motor complexes (CPMCs) in mouse colonic segments. CPMC frequency, contractile and total mechanical activity were assessed. To validate the assay, two experimental protocols were conducted. Initially, five drugs with known gastrointestinal effects were tested to determine optimal parameters describing excitation and inhibition as markers for disturbances in colonic motility. This was followed by a 'blinded' evaluation of nine drugs associated with or without clinically identified constipation/diarrhea-type GADRs. Concentration-response relationships were determined for these drugs and the effects were compared with their maximal free therapeutic plasma concentration in humans. The assay detected stimulatory and inhibitory responses, likely correlating to the occurrence of diarrhea or constipation. Concentration-related effects were identified and potential mechanisms of action were inferred for several drugs. Based on the results from the fourteen drugs assessed, the sensitivity of the assay was calculated at 90%, with a specificity of 75% and predictive capacity of 86%. These results support the potential use of this assay in screening for motility-related GADRs during early discovery phase, safety pharmacology assessment.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurement of the Static Nonlinear Third-Order Elastic Moduli of Rocks: Problems and Applicability

The third-order elastic (TOE) model has been used to describe the widely observed nonlinear mechanical behaviors of earth materials. In addition to linear elastic constants ( λ , μ ), three nonlinear elastic moduli ( A , B , C ) are required for isotropic rocks. Contrary to previous research on dynamic TOE moduli, this study followed the protocol to measure strain and stress under uniaxial and hydrostatic compressive tests statically, which were later used to invert for the full set of TOE moduli for four standard rock types with differing pore structures of a porous oolitic limestone, quartz-rich sandstones, and a dense crystalline basalt. The applicability of the TOE model to characterize nonlinearity depends on the fulfillment of path-independence and small-strain assumptions. Using the measured static TOE moduli, the finite element model demonstrates that the stress in the vicinity of the wellbore is more amplified than the stress in the linear elastic case, which leads to a wider zone of rock failure around the wellbore. Due to the long-standing discrepancy between static and dynamic moduli, the rarely reported full set of static TOE moduli is necessary and will benefit future research in understanding the effect of rock nonlinearity on geophysical and geomechanical applications, such as long-term safe storage of CO 2 and generating process of geohazards.

58 GEOSCIENCES↗

Universal squash model for optical communications using linear optics and threshold detectors

Transmission of photons through open-air or optical fibers is an important primitive in quantum-information processing. Theoretical descriptions of this process often consider single photons as information carriers and thus fail to accurately describe experimental implementations where any number of photons may enter a detector. It has been a great challenge to bridge this big gap between theory and experiments. One powerful method for achieving this goal is by conceptually squashing the received multiphoton states to single-photon states. However, until now, only a few protocols admit a squash model; furthermore, a recently proven no-go theorem appears to rule out the existence of a universal squash model. Here we show that a necessary condition presumed by all existing squash models is in fact too stringent. By relaxing this condition, we find that, rather surprisingly, a universal squash model actually exists for many protocols, including quantum key distribution, quantum state tomography, Bell's inequality testing, and entanglement verification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗