Acoustic sensors devoted to the detection of leaking irradiated fuel rod in spent fuel pool
The acoustic sensor has been specially designed in order to provide a non-destructive technique to easily carry out the measurement of the internal gas pressure and gas composition of a LWR nuclear fuel rod. This sensor has been achieved in 2007 and is now covered by an international patent. In 2015, we presented a generation of acoustic sensors devoted to the characterization of fission gas. The gas composition can be defined with an uncertainty of about 1% and the pressure with an uncertainty of about 10 % (for around 50 bars and a gas mixture containing 20% Xe/Kr). This measurement is possible in hot laboratory facility using viscous liquid to couple the sensor with the rod. We develop a new acoustic sensor for an application in a spent fuel pool without viscous liquid to couple the sensor with the rod. This application consists in determining the default rod in a fuel assembly which has been declared 'no leak-proof' during the fuel discharging of the reactor. We develop a new method based on the detection of gas pressure drop into the fuel rod. This new method could replace the current one which is based on the detection of water into the fuel rod. The new generation of transducer and the associated methodology are now operational in laboratory for nondestructive measurement under water and enable to detect the gas pressure drop into the fuel rod. (authors)