Acoustic Diagnosis Of Faulty Dynamic-Pressure Sensors
New use for particle-impact-noise detector found. Dynamic-pressure sensors and accelerometers that tend to produce spurious readings identified with help of particle-impact-noise detector, PIND.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
New use for particle-impact-noise detector found. Dynamic-pressure sensors and accelerometers that tend to produce spurious readings identified with help of particle-impact-noise detector, PIND.
System developed that monitors integrity of composite-material structural components of aircraft in service. Includes strain gauges and accelerometers installed permanently in components to monitor vibrations, microprocessor-based data-acquisition system to process outputs of these vibration sensors, and desktop computer to analyze acquired data. By automating significant part of inspection process, system reduces amount of time needed for inspection and cost of inspection equipment. Contributes to safety by giving timely warning of hidden flaws that necessitate early, detailed inspection of critical components to determine whether components should be replaced immediately.
Torque actuator and associated control system minimizes effective friction of rotary bearing. Motor exerts compensating torque in response to feedback from external optical sensor. Compensation torque nearly cancels frictional torque of shaft bearings. Also useful in reducing bearing friction in gyro-scopes, galvanometers, torquemeters, accelerometers, earth-motion detectors, and balances.
Improved feedback circuit designed for use in controlling tunneling displacement transducer. Features include stability and nearly flat frequency response up to 50 kHz. Transducer could be that in scanning tunneling microscope, or any of micromachined electromechanical transducers described in "Micromachined Electron-Tunneling Infrared Detectors" (NPO-18413), "Micromachined Tunneling Accelerometer" (NPO-18513), and "Improved Electromechanical Infrared Sensor" (NPO-18560).
Proposed electromechanical infrared detector improved version of device described in "Micromachined Electron-Tunneling Infrared Detectors" (NPO-18413). Fabrication easier, and undesired sensitivity to acceleration reduced. In devices, diaphragms and other components made of micromachined silicon, and displacements of diaphragms measured by electron tunneling displacement transducer {see "Micromachined Tunneling Accelerometer" (NPO-18513)}. Improved version offers enhanced frequency response and less spurious response to acceleration.
Report describes development of active inertial vibration isolators and dampers in which actuators electromagnet coils moving linearly within permanent magnetic fields in housings, somewhat as though massive, low-frequency voice coils in loudspeakers. Discusses principle of operation, electrical and mechanical considerations in design of actuators, characteristics of accelerometers, and frequency responses of control systems. Describes design and performance of one- and three-degree-of-freedom vibration-suppressing system based on concept.
In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.
The current low frequency microgravity requirements for Space Station Freedom (SSF) call for a level of less than 1 micro-g over 50 percent of all the laboratory racks for continuous periods of 30 days for at least 180 days per year. While this requirement is attainable for some of the laboratory modules for the Permanently Manned Configuration (PMC), it can not be met for the Man-Tended Configuration (MTC). In addition, many experiments would prefer even lower acceleration levels. To improve the microgravity environment, the Microgravity Enhancement System (MESYS) will apply a continuous thrust to SSF, to negate the disturbing gravity gradient and drag forces. The MESYS consists of a sensor, throttle-able thrusters and a control system. Both a proof mass system and accelerometer were evaluated for use as the sensor. The net result of the MESYS will be to shift the microgravity contours from the center of mass to a chosen location. Results indicate the MESYS is not feasible for MTC since it will require 5,073 kg of hydrazine fuel and 7,660 watts of power for 30 days of operation during average atmospheric conditions. For PMC, the MESYS is much more practical since only 4,008 kg of fuel and 5,640 watts of power are required.
The NASA LeRC Learjet aircraft is used to fly parabolic trajectories for carrying out in-flight microgravity experiments. To derive full benefit from data obtained in such experiments, it is not only required to understand the low- to moderate-frequency accelerations present but also necessary to characterize the broadband aircraft vibro-acoustic environment. A vibro-acoustic measurement program was conducted during a series of low-gravity trajectories flown on the Learjet. The fuselage and an experiment rack were instrumented with 13 channels of accelerometers and three channels of pressure transducers. The locations of these sensors were determined in order to build a time history of the dynamics involved in the flight of such a parabolic trajectory and thus determine the typical rigid-body and vibro-acoustic loading a payload would experience. The instrumentation, data acquisition sequence, and experimental results showing residual accelerations and high-frequency dynamics are presented. As suspected, the measurements revealed that the aircraft environment cannot simply be described in terms of the static level low-gravity g-vector obtained, but that it also must account for both rigid-body and high-frequency vibro-acoustic dynamics.
During fiscal 1993, the Consortium for Materials Development in Space (CMDS) maintained the organizational structure and project orientation established in prior years. The commercial objectives are improved materials, biomedical applications, and infrastructure and support hardware. Projects include nonlinear optical materials; space materials (specifically polymer foam/films, atomic oxygen and high temperature superconductors); alloyed and blended materials: sintered and alloyed materials; polymer and carbonate blends; electrodeposition; organic separation; materials dispersion and biodynamics; space carriers: Consort, COMET support, Spacehab utilization; and flight services: accelerometers, CMIX, USEC, ORSEP, and Space Experiment Facility (SEF).
A bicycle ergometer system has been developed to determine forces acting in specific muscles and muscle groups for both cycling and isometric exercise. The bicycle has been instrumented with encoders, accelerometers, and load cells. A harnessing system has been developed to keep subjects in place during isometric exercise. EMG data will also be collected with electrodes attached to various muscles on the subject's leg. Data has been collected for static loading and will be collected for cycling in both an earth-based laboratory and on the KC-135. Once the data is analyzed, the forces will be entered into finite element models of bones of the lower extremities. A finite element model of the tibia-fibula has been generated from the experimental subject's MRI data. The linear elastic isoparametric brick elements representing the bones are connected by linear elastic isoparametric shell elements placed at the locations of ligaments. Models will be generated for the calcaneus and the femur. Material properties for the various tissues will be taken from the literature. The experimentally determined muscle forces will be applied to the models to determine the stress distribution which is created in the bones.
A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.
The industrial and scientific communities have shown genuine interest in electronic systems which can operate at high temperatures, among which are sensors to monitor noise, vibration, and acoustic emissions. Acoustic sensing can be accomplished by a wide variety of commercially available devices, including: simple piezoelectric sensors, accelerometers, strain gauges, proximity sensors, and fiber optics. Of the several sensing mechanisms investigated, piezoelectrics were found to be the most prevalent, because of their simplicity of design and application and, because of their high sensitivity over broad ranges of frequencies and temperature. Numerous piezoelectric materials are used in acoustic sensors today; but maximum use temperatures are imposed by their transition temperatures (T(sub c)) and by their resistivity. Lithium niobate, in single crystal form, has the highest operating temperature of any commercially available material, 650 C; but that is not high enough for future requirements. Only two piezoelectric materials show potential for use at 1000 C; AlN thin film reported to be piezoactive at 1150 C, and perovskite layer structure (PLS) materials, which possess among the highest T(sub c) (greater than 1500 C) reported for ferroelectrics. A ceramic PLS composition was chosen. The solid solution composition, 80% strontium niobate (SN) and 20% strontium tantalate (STa), with a T(sub c) approximately 1160 C, was hot forged, a process which concurrently sinters and renders the plate-like grains into a highly oriented configuration to enhance piezo properties. Poled samples of this composition showed coupling (k33) approximately 6 and piezoelectric strain constant (d33) approximately 3. Piezoactivity was seen at 1125 C, the highest temperature measurement reported for a ferroelectric ceramic. The high temperature piezoelectric responses of this, and similar PLS materials, opens the possibility of their use in electronic devices operating at temperatures up to 1000 C. Concurrent with the materials study was an effort to define issues involved in the development of a microphone capable of operation at temperatures up to 1000 C; important since microphones capable of operation above 260 C are not generally available. The distinguishing feature of a microphone is its diaphragm which receives sound from the atmosphere: whereas, most other acoustic sensors receive sound through the solid structure on which they are installed. In order to gain an understanding of the potential problems involved in designing and testing a high temperature microphone, a prototype was constructed using a commercially available lithium niobate piezoelectric element in a stainless steel structure. The prototype showed excellent frequency response at room temperature, and responded to acoustic stimulation at 670 C, above which temperature the voltage output rapidly diminished because of decreased resistivity in the element. Samples of the PLS material were also evaluated in a simulated microphone configuration, but their voltage output was found to be a few mV compared to the 10 output of the prototype.
Controls-Structures Integration Technology has been applied to the Space Shuttle Remote Manipulator System (RMS) to improve on-orbit performance. The objective was to actively damp undesired oscillatory motions of the RMS following routine payload maneuvering and Shuttle attitude control thruster firings. Simulation of active damping was conducted in the real-time, man-in-the-loop Systems Engineering Simulator at NASA's Johnson Space Center. The simulator was used to obtain qualitative and quantitative data on active damping performance from astronaut operators. Using a simulated three-axis accelerometer mounted on the RMS, 'sensed' vibration motions were used to generate joint motor commands that reduced the unwanted oscillations. Active damping of the RMS with heavy and light attached payloads was demonstrated in this study. Five astronaut operators examined the performance of active damping following operator commanded RMS maneuvers and Shuttle thruster firings. Noticeable improvements in the damping response of the RMS with the heavy, Hubble Space Telescope payload and the very light, astronaut in Manipulator Foot Restraint payload were observed. The potential of active damping to aid in precisely maneuvering payloads was deemed significant.
The objective of this study is to experimentally determine an empirical model of the vibrational dynamics of the Spacecraft COntrol Laboratory Experiment (SCOLE) facility. The first two flexible modes of this test article are identified using a linear least-square identification procedure and the data utilized for this procedure are obtained by exciting the structure from a quiescent state with torque wheels. The time history data of rate gyro sensors and accelerometers due to excitation and after excitation in terms of free-decay are used in the parameter estimation of the vibrational model. The free-decay portion of the data is analyzed using the Discrete Fourier transform to determine the optimal model order to use in modelling the response. Linear least-square analysis is then used to select the parameters that best fit the output of an Autoregressive (AR) model to the data. The control effectiveness of the torque wheels is then determined using the excitation portion of the test data, again using linear least squares.
The first comprehensive ground vibration survey was performed on the XV-15 Tiltrotor Research Aircraft to measure the vibration modes of the airframe and to provide data critical for determining whirl flutter stability margins. The aircraft was suspended by the wings with bungee cords and cables. A NASTRAN finite element model was used in the design of the suspension system to minimize its interference with the wing modes. The primary objective of the test was to measure the dynamic characteristics of the wings and pylons for aeroelastic stability analysis. In addition, over 130 accelerometers were placed on the airframe to characterize the fuselage, wing, and tail vibration. Pretest predictions were made with the NASTRAN model as well as correlations with the test data. The results showed that the suspension system provided the isolation necessary for modal measurements.
The second U.S. Microgravity Payload (USMP-2) was flown on the Space Shuttle in March 1994. It carried four major microgravity experiments plus a sophisticated accelerometer system to record the microgravity environment during USMP-2 operations. The USMP program is designed to accommodate experiments requiring extensive resources short of a full Spacelab mission, and the experiments are remotely operated and monitored. Results are reviewed from the four experiments: the Advanced Automated Directional Solidification Facility (AADSF), the Isothermal Dendrite Growth Experiment (IDGE), the Materiel por Etude des Phenomenes Interessant la Soldification sur Terre et en Orbite (MEPHISTO), and the Critical Fluid Light Scattering Experiment (Zeno). AASDF grew what is expected to be the largest steady-state sample ever of HgCdTe during 240 hours of operation. IDGE provided 60 growth cycles over a wide range of supercooling conditions studying the dendritic solidification of succinonitrile. MEPHISTO achieved 55 melt-solidify cycles and grew over 1 m of Bi/Sn alloy. Zeno located the critical point temperature for liquid Xe to 0.00001 K. IDGE and Zeno also provided the most extensive demonstrations to date of telescience.
Work under this grant was carried out by the author and by a graduate research assistant. An instrumented bicycle ergometer was implemented focusing on the stated objective: to estimate the forces exerted by each muscle of the feet, calf, and thigh of an individual while bicycling. The sensors used were light and compact. These were probes to measure muscle EMG activity, miniature accelerometers, miniature load sensors, and small encoders to measure angular positions of the pedal. A methodology was developed and implemented to completely describe the kinematics of the limbs using data from the sensors. This work has been published as a Master's Thesis by the Graduate student supported by the grant. The instrumented ergometer along with the sensors and instrumentation were tested during a KC-135 Zero-Gravity flight in July, 1994. A complete description of the system and the tests performed have been published as a report submitted to NASA Johnson Space Center. The data collected during the KC-135 flight is currently being processed so that a kinematic description of the bicycling experiment will be soon determined. A methodology to estimate the muscle forces has been formulated based on previous work. The methodology involves the use of optimization concepts so that the individual muscle forces that represent variables in dynamic equations of motion may be estimated. Optimization of a criteria (goal) function such as minimization of energy will be used along with constraint equations defined by rigid body equations of motion. Use of optimization principles is necessary, because the equations of motion alone constitute an indeterminate system of equations with respect to the large amount of muscle forces which constitute the variables in these equations. The number of variables is reduced somewhat by using forces measured by the load cells installed on the pedal. These load cells measure pressure and shear forces on the foot. The author and his collaborators at NASA and at the University of Alabama, Tuscaloosa, are continuing the work of reducing the experimental data from the KC-135 flight, and the implementation of the optimization methods to estimate muscle forces. As soon as results from these efforts are available, they will be published in reputable journals. Results of this work will impact studies addressing bone density loss and development of countermeasures to minimize bone loss in zero gravity conditions. By analyzing muscle forces on Earth and in Space during exercise, scientists could eventually formulate new exercises and machines to help maintain bone density. On Earth, this work will impact studies concerning arthritis, and will provide the means to study possible exercise countermeasures to minimize arthritis problems.