Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Controlling Interactions between Quantum Emitters Using Atom Arrays

We investigate the potential for two-dimensional atom arrays to modify the radiation and interaction of individual quantum emitters. Specifically, we demonstrate that control over the emission linewidths, resonant frequency shifts, and local driving field enhancement in impurity atoms is possible due to strong dipole-dipole interactions within ordered, subwavelength atom array configurations. We demonstrate that these effects can be used to dramatically enhance coherent dipole-dipole interactions between distant impurity atoms within an atom array. Possible experimental realizations and potential applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault-tolerant optical interconnects for neutral-atom arrays

We analyze the use of photonic links to enable large-scale fault-tolerant connectivity of locally error-corrected modules based on neutral atom arrays. Our approach makes use of recent theoretical results showing the robustness of surface codes to boundary noise and combines recent experimental advances in atom-array quantum computing with logical qubits with optical quantum networking techniques. We find the conditions for fault tolerance can be achieved with local two-qubit Rydberg gate and nonlocal Bell-pair errors below 1% and 10%, respectively, without requiring distillation or space-time overheads. Realizing the interconnects with a lens, a single optical cavity, or an array of cavities enables—with sufficient multiplexing—a Bell-pair generation rate in the 1–50 MHz range. When directly interfacing logical qubits, this rate translates to error-correction cycles in the 25–2000 kHz range, satisfying all requirements for fault tolerance and in the upper range fast enough for 100 kHz logical clock cycles. Published by the American Physical Society 2025

Sinclair, Josiah (ORCID:0000000215238295)↗

Influence of conical wire array geometry on plasma flow and temperature profiles of radiatively cooled jets

The influence of conical wire array geometry on the formation and dynamics of pulsed-power driven plasma jets is investigated. In the experiments, the jet becomes isolated from the inflows as it passes through an aperture, allowing the study of its intrinsic evolution for different conical angles. Here, our results show that, regardless of the array opening angle, the jets are supersonic, highly collisional, and exhibit an exponential axial density decay with a characteristic scale length of 𝐿 𝑛 ≈ 3 mm, significantly shorter than the overall length of the jet. In contrast, axial velocity systematically increases with larger array opening angles. The near invariance of the density profile is attributed to a compensating mechanism between geometric divergence and axial acceleration, consistent with an asymptotically steady flow regime. Additionally, temperature measurements reveal ion-electron thermal decoupling near the base of the jet, with equilibration downstream. Analysis of radiative cooling and collisional energy exchange timescales indicates that the plasma evolves in a radiatively stable regime and that the two-temperature profile is fully described by the competition between both methods. These findings provide valuable information into the internal structure and evolution of pulsed-power plasma jets in regimes dominated by geometric shaping and radiative cooling, demonstrating experimental control over flow acceleration and collimation relevant to both laboratory and astrophysical contexts.

Physics - Plasma physics↗

Distributed-Memory Sparse Deep Neural Network Inference Using Global Arrays

Partitioned Global Address Space (PGAS) models exhibit tremendous promise in developing efficient and productive distributed-memory parallel applications. They have been used extensively in scientific computations due to conveniently offering a ``shared-memory''-like model and convenient interfaces that separate communication with synchronization. Traditionally, PGAS communication models have been applied to dense/contiguously distributed data, but most modern applications depict varied levels of sparsity. Existing PGAS models require certain adaptations to support distributed sparse computations, since associated computations often require matrix arithmetic, in addition to data movement. The Global Arrays toolkit from Pacific Northwest National Laboratory (PNNL) is one of the earliest PGAS models to combine one-sided data communication and distributed matrix operations and is still used in the popular NWChem quantum chemistry suite. Recently, we have expanded the Global Arrays toolkit to support common sparse operations, like sparse matrix-dense matrix multiplies (SpMM), sparse matrix-sparse matrix multiplication (SpGEMM) and Sampled Dense-Dense Matrix Multiplication (SDDMM). As it turns out, these operations are the bedrock of sparse Deep Learning (DL); sparse deep neural networks and Graph Neural Networks (GNNs) have gained increasing attention recently in achieving speedups on training and inference with reduced memory footprints. Unlike scientific applications in High Performance Computing (HPC), modern (distributed-memory capable) DL toolkits often rely on non-standardized and closed-source vendor software optimizations, creating challenges in software-hardware co-design at scale. Our goal is to support a variety of distributed-memory sparse matrix operations and helper functions in the newly created Sparse Global Arrays (SGA), such that it is possible to build portable and productive Machine Learning scenarios for algorithm/software and hardware codesign purposes. Contemporary data-parallel schemes for training/inference are undergoing a major overhaul since model replication limits scalability and causes resource inefficiencies. As such, we have adopted tensor parallelism in decomposing the model and inputs, to mitigate memory issues. Current implementation is built on top of MPI and uses CPUs to maximize the portability across the platforms.

Distributed computing, machine learning↗

DynPaC: Coarse-Grained, Dynamic, and Partially Reconfigurable Array for Streaming Applications

Coarse-grained reconfigurable arrays (CGRAs) provide higher flexibility than application-specific integrated circuits (ASICs) and higher efficiency than fine-grained reconfigurable devices such as Field Programmable Gate Arrays (FPGAs). However, CGRAs are generally designed to support offloading of a single kernel. While their design, based on communicating functional units, appears to naturally suit streaming applications composed of multiple cooperating kernels, current approaches only statically partition the resources across kernels. However, streaming applications often are data-dependent, leading to variable kernel execution times depending on the input data and impacting the throughput of the entire pipeline if resources are statically allocated. Therefore, in this paper, we discuss the design of DynPaC — a coarse-grained, dynamically, and partially reconfigurable array for data-dependent streaming applications. We discuss the required software and hardware components to manage partial dynamic reconfiguration. We demonstrate that by supporting partial dynamic reconfiguration, we can obtain an average speedup of 1.44X for a representative set of applications w.r.t. static partitioning, with a limited area overhead (6.4% of the entire chip).

Tan, Cheng↗

Spray: Sparse Reductions of Arrays in OPEN MP

We present SPRAY, an open-source header-only C++ library for sparse reductions of arrays. SPRAY is meant for applications in which a large array is collaboratively updated by multiple threads using an associative and commutative operation such as +=. Especially when each thread accesses only parts of the array, SPRAY can perform significantly better than OPENMP's built-in reduction clause or atomic updates, while also using less memory than the former. SPRAY provides both an easy-to-use interface that can serve as a drop-in replacement for OPENMP reductions and a selection of reducer objects that accumulate the final result in different thread-safe ways. We demonstrate SPRAY through multiple test cases including the LULESH shock hydrodynamics code and a transpose-matrix-vector multiplication for sparse matrices stored in CSR format. SPRAY reductions outperform built-in OPENMP reductions consistently, in some cases improving run time and memory overhead by 20X, and even beating domain-specific approaches such as Intel MKI, by over 2X in some cases. Furthermore, SPRAY reductions have a minimal impact on the code base, requiring only a few lines of source code changes. Once in place, SPRAY reduction schemes can be switched easily, allowing performance portability and tuning opportunities by separating performance-critical implementation details from application code.

OpenMP↗

A Novel Scalable Array Design for III-V Compound Semiconductor-based Nonvolatile Memory (UltraRAM) with Separate Read-Write Paths

The dream of achieving a universal memory that can provide robust non-volatile memory states along with low-energy operation has been the key driving force of memory research. Despite dominating the memory market, conventional charge-based memories cannot satisfy these requirements. However, UltraRAM, an oxide-free charge-based memory cell, aims to achieve both of these requirements. This device achieves non-volatility (with an endurance of over 10 7 cycles and a retention of over 1000 years) along with switching at low-voltage (±2.3 V) utilizing a triple-barrier resonant tunneling (TBRT) structure made of InAs/AlSb. In this work, we propose an array design for UltraRAM-based memory devices. Our proposed memory array features separate read-write path and eliminates the possibility of accidentally switching the memory states stored in the array. Moreover, our design allows us to read all the cells in a column in one cycle without imposing any limit on the scalability. Besides, since the read operation in our proposed design is independent of the write mechanism, there is flexibility to optimize the read operation for memory and in-memory computing applications.

Alam, Shamiul↗

Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

We demonstrate magnetic anomaly detection (MAD) using an array of 24 commercial induction coil magnetometers with stand-off distances from a pulsed 99.8(3) kA·m 2 magnetic dipole source of 260–1200 m. The sparse array is used to estimate the magnetic dipole location, magnitude, and orientation. We demonstrate how independent component analysis (ICA) improves the accuracy and precision of the magnetometer array when estimating the dipole parameters. Using sensor responses recorded from individual source pulses, we estimate the dipole location to within 29 ± 2 m, the magnitude to within 3 ± 3 kA·m 2 , and dipole orientation error to within 19 ± 0.6°.

47 OTHER INSTRUMENTATION↗

Advances and applications in low-power phased array X-band weather radars

Low-cost, low-power X-band phased array radar (LPAR) is an enabling technology for future deployment of distributed short-range radar networks. Such networks offer the potential for superior and lower altitude surveillance of atmospheric and airborne events compared with today's larger, long range national radar networks. Two dimensionally steered (phase-phase steering, without motors or other moving parts) phased array radars are complex systems comprising multiple subsystems including several thousand transmit/receive (T/R) channels, beam steering computers, thermal management. Owing to this complexity and the associated cost, phased array technology has not historically been used in weather and air traffic control radars. Competition for the frequency spectrum traditionally reserved for long-range radars is motivating the search for new approaches to national air surveillance; this has motivated R&D investment in two-dimensional X-band LPAR over the past decade, to the point where prototype systems are now emerging in several application settings including, for the first time, the university research setting. Two-dimensional high-speed (inertia-less) beam steering combined with dual polarization, programmable/adaptive waveforms, and the ability to combine multiple radars into networks is leading to new atmospheric science research opportunities related to hazardous storm forecasting and response, understanding cloud physics, water resource management, monitoring the movement and dispersal of hazardous plumes, and other areas.

54 ENVIRONMENTAL SCIENCES↗

Next Generation Ta-STJ Sensor Arrays for BSM Physics Searches

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.

Laser Calibration↗

Intrinsic Performance Variability in Aligned Array CNFETs

Here, the I-V characteristic of carbon nanotube (CNT) transistors is dictated by the Schottky barrier (SB) at metal-nanotube interface. The SB is defined by the diameter of the CNT along with the source/drain metal and is presumed a device constant for single CNT transistors. Given the wide distribution of diameter of CVD-grown nanotubes, the presumption of single SB, however, is inappropriate for transistors with aligned array of CNTs. Indeed, array transistors with similar geometries and contact material can still exhibit considerable variation in threshold voltage (V T ), on current (I ON ), and device resistance (R d ). We use measured diameter distribution within the framework of detailed numerical simulations to demonstrate that the diameter distribution of CNTs (in CNT FETs) plays a dominant role in defining the fluctuation of array transistors. Besides, it is argued that the large-scale integration of these devices within an IC would be feasible only if the distribution of diameter is considerably narrowed.

42 ENGINEERING↗

Effects of Pin Detached Space on Heat Transfer and Pin-Fin Arrays

Heat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W=76.2 mm, E=25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D=6.35 mm=¼E, three different pin-fin height-to-diameter ratios, H/D=4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin tip and one of the endwalls, i.e., C/D=0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the unobstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain the distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin tip and the endwall has a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D, leads to lower heat transfer enhancement and pressure drop. However, C/D=1, i.e., H/D=3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D=0 and C/D=2, i.e., H/D=4 or 2, respectively.

42 ENGINEERING↗

Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Characterization and operation optimization of large aperture optical interferometers using binary pseudorandom array test standards

Recently, a technique for calibration of the Modulation Transfer Function (MTF) of a broad variety of metrology instrumentation has been established. The technique is based on test samples structured according to binary pseudorandom (BPR) one-dimensional sequences and two-dimensional arrays. The inherent power spectral density of BPR gratings and arrays, has a deterministic white-noise-like character that allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: Functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments working with support of the U.S. Department of Energy on industrialization of the technique. The goal is to develop affordable BPR test samples, application procedures, and data processing software, suitable for thorough characterization of optical interferometers and microscopes, as well as x-ray, electron (scanning and transmission), and atomic force microscopes. We report on the development of BPR array test samples optimized for advanced characterization (including the instrumental MTF and aberrations) and operation optimization of large aperture optical interferometers. We describe the sample fabrication process and tests to verify the compliance to desired surface topography. The data acquisition and analysis procedures for application of the technique for precise focusing of Fizeau interferometer are discussed in detail.

Yashchuk, VV↗

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications

A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility ({+-}0.8%) in-field and good accuracy ({+-}1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy

Purpose: In vivo range verification is one of the most important parts of proton therapy to fully utilize its benefits delivering high radiation dose to tumor, while sparing the normal tissue with the so-called Bragg peak. Currently, however, range verification method is not used in clinics. The purpose of the present study is to optimize and evaluate the configuration of an array-type prompt gamma measurement system on determining distal dose edge for in vivo range verification of proton therapy. Methods: To effectively measure the prompt gammas against the background gammas, the Monte Carlo simulations with the MCNPX code were employed in optimizing the configuration of the measurement system, and the Monte Carlo method was also used to understand the effect of the background gammas, mainly neutron capture gammas, in the measured gamma distribution. To reduce the effect of the background gammas, the optimized energy window of 4-10 MeV in measuring the prompt gammas was employed. A parameterized source was used to maximize computation speed in the optimization study. A simplified test measurement system, using only one detector moving from one measurement location to the next, was constructed and applied to therapeutic proton beams of 80-220 MeV. For accurate determination of the distal dose edge, the sigmoidal curve-fitting method was applied to the measured distributions of the prompt gammas, and then, the location of the half-value between the maximum and minimum value in the curve-fitting was determined as the distal dose edge and compared with the beam range assessed by the proton dose distribution. Results: The parameterized source term employed in optimization process improved the calculation speed by up to {approx}300 times. The optimization study indicates that an array-type measurement system with 3, 2, 2, and 150 mm for scintillator thickness, slit width, septal thickness, and slit length, respectively, can effectively measure the prompt gamma distributions minimizing the contribution of background gammas. The present results show that a few hundred counts of prompt gammas can be easily obtained by measuring 10 s at each measurement location for proton beams of {approx}4 nA. The distal dose edges determined by the prompt gamma distribution are 5.45, 14.73, and 27.74 cm for proton beams of 5.17 (80 MeV), 14.99 (150 MeV), and 27.38 (220 MeV) cm, respectively. Conclusions: The results show that the array-type measurement system can measure prompt gamma distributions from a therapeutic proton beam within a short measurement time, and that the distal dose edge can be determined within a few millimeters of error without using any sophisticated analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗