Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Photoinduced Reconfiguration Cycle in a Molecular Adsorbate Layer Studied by Femtosecond Inner-Shell Photoelectron Spectroscopy

A time-resolved study of core-level chemical shifts in a monolayer of aromatic molecules reveals complex photoinduced reaction dynamics. The combination of electron spectroscopy for chemical analysis and ultrashort pulse excitation in the extreme ultraviolet allows performing time-correlated 4d-core-level spectroscopy of iodine atoms that probe the local chemical environment in the adsorbate molecule. The selectivity of the method unveils metastable molecular configurations that appear about 50 ps after the excitation and are efficiently quenched back to the ground state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Design of Sinuous Antennas for UWB Radar Applications

We present that sinuous antennas are capable of producing ultra-wideband radiation with polarization diversity. This capability makes the sinuous antenna an attractive candidate for UWB polarimetric radar applications. Additionally, the ability of the sinuous antenna to be implemented as a planar structure makes it a good fit for close in sensing applications such as ground penetrating radar. However, recent literature has shown the sinuous antenna to suffer from resonances which degrade performance. Such resonances produce late time ringing which is particularly troubling for pulsed close in sensing applications. The resonances occur in two forms: log-periodic resonances on the arms, and a resonance due to the sharp ends left by the outer truncation. A detailed investigation as to the correlation between the log-periodic resonances and the sinuous antenna design parameters indicates the resonances may be mitigated by selecting appropriate design parameters. Additionally, a novel truncation method is proposed to remove the sharp end resonance. Both simulation and measured results are provided to support the developed sinuous antenna design guidance.

42 ENGINEERING↗

Perspectives on UV and x-ray photoelectron spectroscopy

Atomic photoionization using electron spectroscopy was one of the scientific topics in which Professor David A. Shirley excelled and established a research legacy. We discuss selected highlights of atomic photoionization research done by the Shirley group beginning in the 1970s. Our main topics are electron correlation satellites, photoelectron angular distributions with tunable synchrotron radiation, and developments of theory. We also discuss examples of more recent research that extends the earlier work, including double K-shell photoionization, nondipole interactions, and the pervasive role of interchannel coupling. Furthermore, we conclude with examples of current experimental and theoretical research.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm

The purpose of this study is to evaluate dose prediction errors (DPEs) and optimization convergence errors (OCEs) resulting from use of a superposition/convolution dose calculation algorithm in deliverable intensity-modulated radiation therapy (IMRT) optimization for head-and-neck (HN) patients. Thirteen HN IMRT patient plans were retrospectively reoptimized. The IMRT optimization was performed in three sequential steps: (1) fast optimization in which an initial nondeliverable IMRT solution was achieved and then converted to multileaf collimator (MLC) leaf sequences; (2) mixed deliverable optimization that used a Monte Carlo (MC) algorithm to account for the incident photon fluence modulation by the MLC, whereas a superposition/convolution (SC) dose calculation algorithm was utilized for the patient dose calculations; and (3) MC deliverable-based optimization in which both fluence and patient dose calculations were performed with a MC algorithm. DPEs of the mixed method were quantified by evaluating the differences between the mixed optimization SC dose result and a MC dose recalculation of the mixed optimization solution. OCEs of the mixed method were quantified by evaluating the differences between the MC recalculation of the mixed optimization solution and the final MC optimization solution. The results were analyzed through dose volume indices derived from the cumulative dose-volume histograms for selected anatomic structures. Statistical equivalence tests were used to determine the significance of the DPEs and the OCEs. Furthermore, a correlation analysis between DPEs and OCEs was performed. The evaluated DPEs were within {+-}2.8% while the OCEs were within 5.5%, indicating that OCEs can be clinically significant even when DPEs are clinically insignificant. The full MC-dose-based optimization reduced normal tissue dose by as much as 8.5% compared with the mixed-method optimization results. The DPEs and the OCEs in the targets had correlation coefficients greater than 0.71, and there was no correlation for the organs at risk. Because full MC-based optimization results in lower normal tissue doses, this method proves advantageous for HN IMRT optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system

Purpose: Undertaking observer studies to compare imaging technology using clinical radiological images is challenging due to patient variability. To achieve a significant result, a large number of patients would be required to compare cancer detection rates for different image detectors and systems. The aim of this work was to create a methodology where only one set of images is collected on one particular imaging system. These images are then converted to appear as if they had been acquired on a different detector and x-ray system. Therefore, the effect of a wide range of digital detectors on cancer detection or diagnosis can be examined without the need for multiple patient exposures. Methods: Three detectors and x-ray systems [Hologic Selenia (ASE), GE Essential (CSI), Carestream CR (CR)] were characterized in terms of signal transfer properties, noise power spectra (NPS), modulation transfer function, and grid properties. The contributions of the three noise sources (electronic, quantum, and structure noise) to the NPS were calculated by fitting a quadratic polynomial at each spatial frequency of the NPS against air kerma. A methodology was developed to degrade the images to have the characteristics of a different (target) imaging system. The simulated images were created by first linearizing the original images such that the pixel values were equivalent to the air kerma incident at the detector. The linearized image was then blurred to match the sharpness characteristics of the target detector. Noise was then added to the blurred image to correct for differences between the detectors and any required change in dose. The electronic, quantum, and structure noise were added appropriate to the air kerma selected for the simulated image and thus ensuring that the noise in the simulated image had the same magnitude and correlation as the target image. A correction was also made for differences in primary grid transmission, scatter, and veiling glare. The method was validated by acquiring images of a CDMAM contrast detail test object (Artinis, The Netherlands) at five different doses for the three systems. The ASE CDMAM images were then converted to appear with the imaging characteristics of target CR and CSI detectors. Results: The measured threshold gold thicknesses of the simulated and target CDMAM images were closely matched at normal dose level and the average differences across the range of detail diameters were -4% and 0% for the CR and CSI systems, respectively. The conversion was successful for images acquired over a wide dose range. The average difference between simulated and target images for a given dose was a maximum of 11%. Conclusions: The validation shows that the image quality of a digital mammography image obtained with a particular system can be degraded, in terms of noise magnitude and color, sharpness, and contrast to account for differences in the detector and antiscatter grid. Potentially, this is a powerful tool for observer studies, as a range of image qualities can be examined by modifying an image set obtained at a single (better) image quality thus removing the patient variability when comparing systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Luminosity determination using Z boson production at the CMS experiment

The measurement of Z boson production is presented as a method to determine the integrated luminosity of CMS data sets. The analysis uses proton–proton collision data, recorded by the CMS experiment at the CERN LHC in 2017 at a center-of-mass energy of 13 TeV. Events with Z bosons decaying into a pair of muons are selected. The total number of Z bosons produced in a fiducial volume is determined, together with the identification efficiencies and correlations from the same data set, in small intervals of 20 pb –1 of integrated luminosity, thus facilitating the efficiency and rate measurement as a function of time and instantaneous luminosity. Using the ratio of the efficiency-corrected numbers of Z bosons, the precisely measured integrated luminosity of one data set is used to determine the luminosity of another. For the first time, a full quantitative uncertainty analysis of the use of Z bosons for the integrated luminosity measurement is performed. The uncertainty in the extrapolation between two data sets, recorded in 2017 at low and high instantaneous luminosity, is less than 0.5%. We show that the Z boson rate measurement constitutes a precise method, complementary to traditional methods, with the potential to improve the measurement of the integrated luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human Perceptions of Colour Rendition at Different Chromaticities

An experiment was conducted to evaluate how subjective impressions of a light source’s color quality depend upon color rendition and chromaticity. Thirty-three participants each evaluated 50 lighting scenes in a 3.7 m by 5.5 m room filled with objects selected to cover a range of hue, saturation, and lightness. The lighting scenes included five chromaticity groups, specified here using correlated color temperature (CCT) and Duv¬: 2700 K, 0.000; 2700 K, -0.007; 3500 K, 0.000; 4300 K, 0.000; 4300 K, -0.007. Within each group were the same 10 systematically-varied color rendition conditions. The Illuminating Engineering Society (IES) TM-30-15 Fidelity Index (Rf) values ranged from 60 to 93, IES TM-30 Gamut Index (Rg) values from 88 to 124, and IES TM-30 Hue Angle Bin 1 Chroma Shift (Rcs,h1) values from -15% to 28%. All lighting scenes had the same nominal illuminance. Participants were asked to rate each scene on eight point scales for saturated-dull, normal-shifted, and like-dislike, as well as choosing whether they found the scenes to be acceptable or unacceptable. The findings suggest that color rendition preferences can vary with chromaticity, but do not support absolute preferences for negative Duv values. At 4300 K, there was no difference in rated preference, saturation, normalness, or acceptability between the two groups with different Duv values. However, at 2700 K, there was a significant difference for all four perceptions, with the negative Duv sources being rated more liked (on average)—and for nine of the ten individual color rendition conditions. Further, across all levels of red chroma shift—according to TM-30 values Rcs,h1, Rcs,h15, and Rcs,h16—the room was rated as more saturated at 2700 K than at 3500 K or 4300 K (regardless of Duv); in turn, increases in red saturation were less preferred and less acceptable at 2700 K than the other CCTs. The differences in ratings between the chromaticity groups were substantially smaller than the range in ratings for the 10 color rendition conditions in each group, and on average the best fit model uses a combination of Rf, Rcs,h16, and potentially Rg. Despite the differences in ratings for chromaticity groups, a set of criteria identified in previous research for preferred color rendition in this generic application could be used for all groups. Those criteria are Rf = 74, -1% = Rcs,h1 = 15%, and Rg = 100.

Royer, Michael P.↗

Reference tissue normalization in longitudinal 18F-florbetapir positron emission tomography of late mild cognitive impairment

Background: Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test–retest 18F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. Methods: We calculated the correlation between 18F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1–42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique—the weighted two-point correlation function (wS2)—to capture potentially more subtle changes in Aβ-PET data. Results: Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1–42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1–42 levels across all time points and reference regions, including the cerebellar gray matter. Conclusions: The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical 18F-florbetapir uptake in longitudinal studies.

59 BASIC BIOLOGICAL SCIENCES↗

Community Resilience Indicator Analysis: Commonly Used Indicators from Peer-Reviewed Research (Updated for Research Published 2003-2021)

In 2017, FEMA’s National Integration Center (NIC) Technical Assistance (TA) Branch identified a need to establish a data-driven basis for prioritizing locations for TA investment and guiding local emergency management planning. To achieve this goal, FEMA tasked Argonne National Laboratory (Argonne) with identifying commonly used indicators of community resilience across the landscape of published peer-reviewed research. FEMA and Argonne completed the first Community Resilience Indicator Analysis (CRIA) in 2018 and repeated the process in 2022. The CRIA process begins with a literature review and cataloguing of published peer-reviewed assessment methodologies on social vulnerability and community resilience. The literature review findings are then filtered by inclusion criteria established by the CRIA research team to ensure the methodologies are: (1) Quantitative, (2) Data and methodology are publicly available, (3) Calculated at the county level or lower, (4) Examine generalized hazard risk (rather than a singular hazard), and (5) Focused on pre-disaster community conditions. After this, the research team identifies the commonly used indicators across these methodologies and selects the best data source for each indicator. Finally, the research team bins the data for visual display, conducts a correlation analysis and creates a composite index, the FEMA Community Resilience Index (FEMA CRI). In 2018, the CRIA identified eight resilience and vulnerability assessment methodologies and 20 commonly used indicators (indicators used in three or more of the eight methodologies). The FEMA CRI in 2018 was created from these 20 indicators and was produced for at the county level. The 2022 CRIA updated the literature review to expand the list of methodologies examined and followed the same process, resulting in an analysis of 14 methodologies published between 2003 and 2021 and 22 indicators identified as commonly used (indicators used in five or more of the 14 methodologies). In 2022, the research team produced the FEMA CRI at the county and the census tract levels. To make the CRIA data more accessible and more actionable, each individual indicator and the FEMA CRI is binned and included in FEMA’s Resilience Analysis and Planning Tool (RAPT). RAPT enables emergency managers and community partners to quickly visualize relative differences in potential resilience by county, tribe and census tract. By reviewing the data for each of these 22 indicators individually, emergency managers can gain insights for targeted outreach strategies, planning, mitigation investments and response and recovery operations. Communities, regional governments and others can use this data to better understand potential challenges to resilience. As the social science field of examining and validating indicators of resilience evolves, FEMA will update RAPT to provide emergency managers and community partners with additional data and tools to inform planning, mitigation, response and recovery. It is important to understand that the role of the emergency manager is not to change or to “improve” the data, but to plan appropriately for the community characteristics reflected in the data. These datasets are community characteristics that researchers have identified as important considerations for resilience. For example, people with disabilities may have greater challenges to be resilient to disasters. If a community has a high population of people with disabilities, the emergency manager(s) may need to create tailored preparedness outreach programs and strategies to ensure those residents have support if evacuation is necessary. Rather than label these indicators as an absolute measure of resilience, FEMA considers “potential challenges to resilience” a better frame to understand these indicators. Everyone is vulnerable to disasters. While scholars theorize that certain characteristics may make an individual or a household more socially vulnerable, the data does not reflect measures that individuals and/or communities have taken to address potential challenges, such as emergency management planning and outreach or household preparedness measures. To aid emergency managers in understanding how to use these indicators, calling them potential challenges to resilience supports a more positive and strategic application of the data in all phases of emergency management.

99 GENERAL AND MISCELLANEOUS↗

Method for voltage-gated protein fractionation

We report unique findings on the voltage dependence of protein exclusion from the pores of nanoporous polymer exclusion membranes. The pores are small enough that proteins are excluded from passage with low applied electric fields, but increasing the field enables proteins to pass through. The requisite field necessary for a change in exclusion is protein-specific with a correlation to protein size. The field-dependence of exclusion is important to consider for preconcentration applications. The ability to selectively gate proteins at exclusion membranes is also a promising means for manipulating and characterizing proteins. We show that field-gated exclusion can be used to selectively remove proteins from a mixture, or to selectively trap protein at one exclusion membrane in a series.

59 BASIC BIOLOGICAL SCIENCES↗

Sample-Averaged Biexciton Quantum Yield Measured by Solution-Phase Photon Correlation

The brightness of nanoscale optical materials such as semiconductor nanocrystals is currently limited in high excitation flux applications by inefficient multiexciton fluorescence. We have devised a solution-phase photon correlation measurement that can conveniently and reliably measure the average biexciton-to-exciton quantum yield ratio of an entire sample without user selection bias. This technique can be used to investigate the multiexciton recombination dynamics of a broad scope of synthetically underdeveloped materials, including those with low exciton quantum yields and poor fluorescence stability. Here in this study, we have applied this method to measure weak biexciton fluorescence in samples of visible-emitting InP/ZnS and InAs/ZnS core/shell nanocrystals, and to demonstrate that a rapid CdS shell growth procedure can markedly increase the biexciton fluorescence of CdSe nanocrystals.

36 MATERIALS SCIENCE↗

Enhancing charge ratio sensitivity to hadronization effects via jet selections on resolved SoftDrop splitting

The study of quantum chromodynamics (QCD) at ultrarelativistic energies can be performed in a controlled environment through lepton-hadron deep inelastic scatterings. In such collisions, the high-energy partonic emissions that follow from the ejected hard partons are accurately described by perturbative QCD. However, the lower energy scales at which quarks and gluons experience color confinement, i.e., hadronization mechanism, fall outside the validity regions for perturbative calculations, requiring phenomenological models tuned to data to describe it. As such, hadronization physics cannot be currently derived from first principles alone. Monte Carlo event generators are useful tools to describe these processes as they simulate both the perturbative and the nonperturbative interactions, with model-dependent energy scales that control parton dynamics. This work employs jets—experimental reconstructions of final-state particles likely to have a common partonic origin—to inspect this transition further. Although originally proposed to circumvent hadronization effects, we show that jets can be utilized as probes of nonperturbative phenomena via their substructure. The charge correlation ratio was recently shown to be sensitive to hadronization effects. Our work further improves this sensitivity to nonperturbative scales by introducing a new selection based on the relative placement of the within the clustering tree, defined as the unclustering that resolves the jet’s leading charged particles. Published by the American Physical Society 2025

Apolinário, Liliana (ORCID:0000000335009681)↗

Imaging Three-Dimensional Molecular Structure and Dynamics with Multiparticle Covariance and Cumulant Coulomb Explosion Analysis

Coulomb explosion imaging (CEI) provides a direct means of imaging molecular geometry by correlating fragment ion momenta following the fragmentation of a molecular polycation. Here, we demonstrate the use of three-body covariance and four-body cumulant analysis to extract three-dimensional (3D) structural information from the X-ray-induced Coulomb explosion of tert-butyl iodide (C4H9I). Site-selective ionization at the iodine 4d edge with intense femtosecond soft X-ray pulses from an X-ray free-electron laser (XFEL) enables rapid charge buildup and molecular breakup. By correlating ionic fragments in the molecular frame, we isolate complete dissociation channels and reveal subtle structural changes, such as umbrella-type motion of the branched alkyl chain, during the ionization process. Comparison with point-charge simulations of the Coulomb explosion shows close agreement, validating the approach. Furthermore, these results establish covariance/cumulant mapping as a powerful strategy for imaging complex three-dimensional molecular structures and point the way toward time-resolved CEI using both XFEL and tabletop sources for capturing ultrafast structural dynamics.

Imaging↗

Statistical analysis of the correlation between active galactic nuclei and ultra-high energy cosmic rays

We develop the statistical methods for comparing two sets of arrival directions of cosmic rays in which the two-dimensional distribution of arrival directions is reduced to the one-dimensional distributions so that the standard one-dimensional Kolmogorov-Smirnov test can be applied. Then we apply them to the analysis of correlation between the ultra-high energy cosmic rays (UHECR) with energies above 5.7 × 10{sup 19} eV, observed by Pierre Auger Observatory (PAO) and Akeno Giant Air Shower Array (AGASA), and the active galactic nuclei (AGN) within the distance 100 Mpc. For statistical test, we set up the simple AGN model for UHECR sources in which a certain fraction of observed UHECR are originated from AGN within a chosen distance, assuming that all AGN have equal UHECR luminosity and smearing angle, and the remaining fraction are from the isotropic background contribution. For the PAO data, our methods exclude not only a hypothesis that the observed UHECR are simply isotropically distributed but also a hypothesis that they are completely originated from the selected AGN. But, the addition of appropriate amount of isotropic component either through the background contribution or through the large smearing effect improves the correlation greatly and makes the AGN hypothesis for UHECR sources a viable one. We also point out that restricting AGN within the distance bin of 40–60 Mpc happens to yield a good correlation without appreciable isotropic component and large smearing effect. For the AGASA data, we don't find any significant correlation with AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the impact of optical selection effects on observed rest-frame prompt GRB properties

Measuring gamma-ray burst (GRB) properties in their rest frame is crucial for understanding the physics at work in GRBs. This can only be done for GRBs with known redshifts. Since redshifts are usually measured from the optical spectrum of the afterglow, correlations between prompt and afterglow emissions may introduce biases into the distribution of the rest-frame properties of the prompt emission, especially considering that we measure the redshift of only one-third of Swift GRBs. In this paper, we study the optical flux of GRB afterglows and its connection to various intrinsic properties of GRBs. We also discuss the impact of the optical selection effect on the distribution of rest-frame prompt properties of GRBs. Our analysis is based on a sample of 90 GRBs with good optical follow-up and well-measured prompt emission. Seventy-six of them have a measure of redshift and 14 have no redshift. We compare the rest-frame prompt properties of GRBs with different afterglow optical fluxes in order to check for possible correlations between the promt properties and the optical flux of the afterglow. The optical flux is measured two hours after the trigger, which is a typical time for the measure of the redshift. We find that the optical flux of GRB afterglows in our sample is mainly driven by their optical luminosity and depends only slightly on their redshift. We show that GRBs with low and high afterglow optical fluxes have similar E {sub pi}, E {sub iso}, and L {sub iso}, indicating that the rest-frame distributions computed from GRBs with a redshift are not significantly distorted by optical selection effects. However, we found that the T{sub 90}{sup rest} distribution is not immune to optical selection effects, which favor the selection of GRBs with longer durations. Finally, we note that GRBs well above the E {sub pi}–E {sub iso} relation have lower optical fluxes and we show that optical selection effects favor the detection of GRBs with bright optical afterglows located close to or below the best-fit E {sub pi}–E {sub iso} relation (Amati relation), whose redshift is easily measurable. With more than 300 GRBs with a redshift, we now have a much better view of the intrinsic properties of these remarkable events. At the same time, increasing statistics allow us to understand the biases acting on the measurements. The optical selection effects induced by the redshift measurement strategies cannot be neglected when we study the properties of GRBs in their rest frame, even for studies focused on prompt emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Predictive Models for Pulmonary Function Changes After Radiotherapy for Breast Cancer and Lymphoma

Purpose: To propose multivariate predictive models for changes in pulmonary function tests ({Delta}PFTs) with respect to preradiotherapy (pre-RT) values in patients undergoing RT for breast cancer and lymphoma. Methods and Materials: A prospective study was designed to measure {Delta}PFTs of patients undergoing RT. Sixty-six patients were included. Spirometry, lung capacity (measured by helium dilution), and diffusing capacity of carbon monoxide tests were used to measure lung function. Two lung definitions were considered: paired lung vs. irradiated lung (IL). Correlation analysis of dosimetric parameters (mean lung dose and the percentage of lung volume receiving more than a threshold dose) and {Delta}PFTs was carried out to find the best dosimetric predictor. Chemotherapy, age, smoking, and the selected dose-volume parameter were considered as single and interaction terms in a multivariate analysis. Stability of results was checked by bootstrapping. Results: Both lung definitions proved to be similar. Modeling was carried out for IL. Acute and late damage showed the highest correlations with volumes irradiated above {approx}20 Gy (maximum R{sup 2} = 0.28) and {approx}40 Gy (maximum R{sup 2} = 0.21), respectively. RT alone induced a minor and transitory restrictive defect (p = 0.013). Doxorubicin-cyclophosphamide-paclitaxel (Taxol), when administered pre-RT, induced a late, large restrictive effect, independent of RT (p = 0.031). Bootstrap values confirmed the results. Conclusions: None of the dose-volume parameters was a perfect predictor of outcome. Thus, different predictor models for {Delta}PFTs were derived for the IL, which incorporated other nondosimetric parameters mainly through interaction terms. Late {Delta}PFTs seem to behave more serially than early ones. Large restrictive defects were demonstrated in patients pretreated with doxorubicin-cyclophosphamide-paclitaxel.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acidity-Governed Rules in the Electrochemical Performance of Fluorinated Benzenes for High-Voltage Lithium Metal Batteries

Judicious selection of the optimal fluorobenzene (FB) as a nonsolvating cosolvent for lithium metal batteries (LMBs) is reported. For this work, we found the key correlation between FB structures and cycling stabilities of cells: increased fluorine substitution of FBs results in higher anodic stability but at the expense of reduced reductive stability, and FBs containing three or more fluorine atoms exhibit insufficient anodic stability in the electrolyte system comprised of fluoroethylene carbonate (FEC) and ethyl methyl carbonate (EMC). More importantly, FBs with higher acidity (lower pK a ) due to protons located between two adjacent fluorine atoms tend to be more susceptible to side reactions during cycling. Our results indicate that difluorobenzenes with no “acidic” proton (DFB2 and DFB4) have emerged as the optimal choice with the desired redox stability in high-voltage LMBs. Nuclear magnetic resonance and X-ray photoelectron spectroscopy confirmed these findings, providing guidance for selecting the most suitable FB variants as nonsolvating cosolvents for high-voltage LMBs.

25 ENERGY STORAGE↗

CANDIDATE CLUSTERS OF GALAXIES AT z > 1.3 IDENTIFIED IN THE SPITZER SOUTH POLE TELESCOPE DEEP FIELD SURVEY

We present 279 galaxy cluster candidates at z > 1.3 selected from the 94 deg{sup 2} Spitzer South Pole Telescope Deep Field (SSDF) survey. We use a simple algorithm to select candidate high-redshift clusters of galaxies based on Spitzer/IRAC mid-infrared data combined with shallow all-sky optical data. We identify distant cluster candidates adopting an overdensity threshold that results in a high purity (80%) cluster sample based on tests in the Spitzer Deep, Wide-Field Survey of the Boötes field. Our simple algorithm detects all three 1.4 < z ≤ 1.75 X-ray detected clusters in the Boötes field. The uniqueness of the SSDF survey resides not just in its area, one of the largest contiguous extragalactic fields observed with Spitzer, but also in its deep, multi-wavelength coverage by the South Pole Telescope (SPT), Herschel/SPIRE, and XMM-Newton. This rich data set will allow direct or stacked measurements of Sunyaev-Zel'dovich effect decrements or X-ray masses for many of the SSDF clusters presented here, and enable a systematic study of the most distant clusters on an unprecedented scale. We measure the angular correlation function of our sample and find that these candidates show strong clustering. Employing the COSMOS/UltraVista photometric catalog in order to infer the redshift distribution of our cluster selection, we find that these clusters have a comoving number density n{sub c}=(0.7{sub −0.6}{sup +6.3})×10{sup −7} h{sup 3} Mpc{sup −3} and a spatial clustering correlation scale length r {sub 0} = (32 ± 7) h {sup –1} Mpc. Assuming our sample is comprised of dark matter halos above a characteristic minimum mass, M {sub min}, we derive that at z = 1.5 these clusters reside in halos larger than M{sub min}=1.5{sub −0.7}{sup +0.9}×10{sup 14} h{sup −1} M{sub ⊙}. We find that the mean mass of our cluster sample is equal to M{sub mean}=1.9{sub −0.8}{sup +1.0}×10{sup 14} h{sup −1} M{sub ⊙}; thus, our sample contains the progenitors of present-day massive galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗