System engineering techniques for establishing balanced design and performance guidelines for the advanced telerobotic testbed

Novel system engineering techniques have been developed and applied to establishing structured design and performance objectives for the Telerobotics Testbed that reduce technical risk while still allowing the testbed to demonstrate an advancement in state-of-the-art robotic technologies. To estblish the appropriate tradeoff structure and balance of technology performance against technical risk, an analytical data base was developed which drew on: (1) automation/robot-technology availability projections, (2) typical or potential application mission task sets, (3) performance simulations, (4) project schedule constraints, and (5) project funding constraints. Design tradeoffs and configuration/performance iterations were conducted by comparing feasible technology/task set configurations against schedule/budget constraints as well as original program target technology objectives. The final system configuration, task set, and technology set reflected a balanced advancement in state-of-the-art robotic technologies, while meeting programmatic objectives and schedule/cost constraints.

Zimmerman, W. F.↗

Aftertreatment protocols for catalyst characterization and performance evaluation: low-temperature oxidation, storage, three-way, and NH3-SCR catalyst test protocols

A set of standardized and realistic aftertreatment catalyst test protocols have been developed by the Advanced Combustion and Emission Control Technical Team in support of the U.S.DRIVE Partnership. The protocols are intended to accelerate the pace of aftertreatment catalyst innovation by enabling the accurate evaluation and comparison of aftertreatment catalyst performance data from various testing and research facilities to maximize the impact of discovery-phase research occurring across the nation. The protocols address a need identified by the Partnership’s industry partners for consistent and accurate metrics for aftertreatment catalyst evaluation and comparison. The protocols consist of a set of standardized requirements and test procedures that sufficiently capture the performance capability of a catalyst technology in a manner that is adaptable in various laboratories. The protocols provide a detailed description of the necessary reactor system, the steps for achieving a desired aged state of the catalyst, all necessary sample pretreatment to be performed prior to testing, and realistic test conditions for evaluating performance. This article details four low-temperature catalyst test protocols applicable to (1) oxidation catalysts, (2) passive storage (and release) catalysts, (3) three-way catalysts, and (4) NH3-SCR catalysts. The catalyst test protocol descriptions are presented in five (5) sections: protocol general guidelines and the four individual catalyst test protocol descriptions. The general guidelines plus the individual protocol description forms the complete low-temperature catalyst test protocol for the application.

Emission control, Three-way catalyst, oxidation, S↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

OECD/MCCI 2-D Core Concrete Interaction (CCI) tests : final report February 28, 2006.

Although extensive research has been conducted over the last several years in the areas of Core-Concrete Interaction (CCI) and debris coolability, two important issues warrant further investigation. The first issue concerns the effectiveness of water in terminating a CCI by flooding the interacting masses from above, thereby quenching the molten core debris and rendering it permanently coolable. This safety issue was investigated in the EPRI-sponsored Melt Attack and Coolability Experiments (MACE) program. The approach was to conduct large scale, integral-type reactor materials experiments with core melt masses ranging up to two metric tons. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanism(s) that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.20 m. This decoupling is not expected for a typical reactor cavity, which has a span of 5-6 m. Even though the crust may mechanically bond to the reactor cavity walls, the weight of the coolant and the crust itself is expected to periodically fracture the crust and restore contact with the melt. Although crust fracturing does not ensure that coolability will be achieved, it nonetheless provides a pathway for water to recontact the underlying melt, thereby allowing other debris cooling mechanisms to proceed. A related task of the current program, which is not addressed in this particular report, is to measure crust strength to check the hypothesis that a corium crust would not be strong enough to sustain melt/crust separation in a plant accident. The second important issue concerns long-term, two-dimensional concrete ablation by a prototypic core oxide melt. As discussed by Foit the existing reactor material database for dry cavity conditions is solely one-dimensional. Although the MACE Scoping Test was carried out with a two-dimensional concrete cavity, the interaction was flooded soon after ablation was initiated to investigate debris coolability. Moreover, due to the scoping nature of this test, the apparatus was minimally instrumented and therefore the results are of limited value from the code validation viewpoint. Aside from the MACE program, the COTELS test series also investigated 2-D CCI under flooded cavity conditions. However, the input power density for these tests was quite high relative to the prototypic case. Finally, the BETA test series provided valuable data on 2-D core concrete interaction under dry cavity conditions, but these tests focused on investigating the interaction of the metallic (steel) phase with concrete. Due to these limitations, there is significant uncertainty in the partition of energy dissipated for the ablation of concrete in the lateral and axial directions under dry cavity conditions for the case of a core oxide melt. Accurate knowledge of this 'power split' is important in the evaluation of the consequences of an ex-vessel severe accident; e.g., lateral erosion can undermine containment structures, while axial erosion can penetrate the basemat, leading to ground contamination and/or possible containment bypass. As a result of this uncertainty, there are still substantial differences among computer codes in the prediction of 2-D cavity erosion behavior under both wet and dry cavity conditions. In light of the above issues, the OECD-sponsored Melt Coolability and Concrete Interaction (MCCI) program was initiated at Argonne National Laboratory. The project conducted reactor materials experiments and associated analysis to achieve the following technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focused on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term 2-D core-concrete interactions under both wet and dry cavity conditions. Data from the various tests conducted as part of the program are being used to develop and validate models and codes that are used to extrapolate the experimental findings to plant conditions. Achievement of these technical objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs of future plants. The project completed three large scale CCI experiments to address the second technical objective defined above.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

KBase Educators Handbook

The KBase Educators Handbook is a community resource for educators teaching biology, computational biology, and bioinformatics using KBase. The Handbook includes supporting documentation on how to join and access community-developed resources for teaching with KBase, best practices, and guidelines on how to contribute to the KBase Educators Community.

59 BASIC BIOLOGICAL SCIENCES↗

Handbook on astronaut crew motion disturbances for control system design

The analyses and results pertinent to the characterization of the disturbances imparted to the Skylab vehicle by the T-013 crew motion experiments are summarized. Guidelines to help control system designers assess anticipated crew motion disturbances during the design cycle of a new manned spacecraft control system are provided. These guidelines, in conjunction with the T-013 characterizations outlined, begin with the control system conceptual design and conclude with preliminary expectations for pointing performance as affected by crew motions. Block diagrams to highlight the contents so that the reader can easily identify the information and data flow are used. These diagrams provide a handy cross reference of related topics.

Kullas, M. C.↗

Transition research using flight experiments

The paper deals with flight experiments as a means of obtaining proper transition information in an uncontaminated environment. Flight transition experiments performed in the early to middle 1950s using rocket-propelled vehicles are outlined. It is noted that the standards for research quality experiments on stability and transition are no different for flight studies than for wind-tunnel experiments. The guidelines formulated by the U.S. Boundary Layer Transition Study Group are listed. Attention is focused on the relationship between the model design and the measurement of disturbance environment, the maintenance and monitoring of test and model-surface conditions, and a need for high data-sampling rates.

Reshotko, Eli↗

Analytical control test plan and microbiological methods for the water recovery test

Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.

Traweek, M. S.↗

Storage and network bandwidth requirements through the year 2000 for the NASA Center for Computational Sciences

The data storage and retrieval demands of space and Earth sciences researchers have made the NASA Center for Computational Sciences (NCCS) Mass Data Storage and Delivery System (MDSDS) one of the world's most active Convex UniTree systems. Science researchers formed the NCCS's Computer Environments and Research Requirements Committee (CERRC) to relate their projected supercomputing and mass storage requirements through the year 2000. Using the CERRC guidelines and observations of current usage, some detailed projections of requirements for MDSDS network bandwidth and mass storage capacity and performance are presented.

Salmon, Ellen↗

Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may increase the level of care.

Hurst, Victor, IV↗

Techniques and Results for Determining Window Placement and Configuration for the Small Pressurized Rover (SPR)

A natural component to driving any type of vehicle, be it Earth-based or space-based, is visibility. In its simplest form visibility is a measure of the distance at which an object can be seen. With the National Aeronautics and Space Administration s (NASA) Space Shuttle and the International Space Station (ISS), there are human factors design guidelines for windows. However, for planetary exploration related vehicles, especially land-based vehicles, relatively little has been written on the importance of windows. The goal of the current study was to devise a proper methodology and to obtain preliminary human-in-the-loop data on window placement and location for the small pressurized rover (SPR). Nine participants evaluated multiple areas along the vehicle s front "nose", while actively maneuvering through several lunar driving simulations. Subjective data was collected on seven different aspects measuring areas of necessity, frequency of views, and placement/configuration of windows using questionnaires and composite drawings. Results indicated a desire for a large horizontal field-of-view window spanning the front of the vehicle for most driving situations with slightly reduced window areas for the lower front, lower corners, and side views.

Thompson, Shelby↗

Overview of the Subscale RAVEN Flight Controls and Modeling Testbed

The Research Aircraft for eVTOL Enabling TechNologies (RAVEN) Subscale Wind-Tunnel and Flight Test (SWFT) model is a subscale aircraft built for flight dynamics and controls research demonstrated in wind-tunnel and flight-test experiments. The intent of this paper is to provide a summary of past, current, and future efforts being pursued by the RAVEN-SWFT project. Initially, vehicle development guidelines were crafted by a multidisciplinary team to ensure that the RAVEN-SWFT vehicle was well suited for research in multiple areas, including aero-propulsive modeling, flight controls, and autonomy, among others. The vehicle has been used to obtain extensive wind-tunnel data, enabling aero-propulsive model development across the transition flight envelope and validation of computational tools. The vehicle will be used to conduct flight testing in order to evaluate modeling strategies and flight control logic. The RAVEN-SWFT model also serves as a risk reduction activity for a conceptual, full-scale vehicle in the 1000-lb class. The next steps in the project are to successfully demonstrate free flight in hover, transition, forward flight, and the reverse thereof, utilizing custom control laws integrated onto the RAVEN-SWFT avionics hardware. The project intends to publicize all of the geometry, data, and methods in future reports.

eVTOL↗

Justification to Disregard U-234 Mass in Certain Uranium Systems

The ANSI/ANS-8.1-1998 Standard regarding nuclear criticality safety in operations with fissionable material outside reactors states certain guidelines for dealing with uranium isotopes when setting mass limits. In ANSI/ANS-8.1-1998 235 U limits apply to mixtures “with 234 U, 236 U, or 238 U, provided that 234 U is considered to be 235U” in computing mass. In this evaluation calculations coupled with benchmark data show a superior way of handling the other common uranium isotopes when setting limits for 235 U. Currently 234 U mass must be considered as 235 U mass in order to account for the fact 234 U has a k ∞ = 1.70 meaning criticality can be reached with a finite amount of 234 U mass. 236 U and 238 U have k ∞ ’s equal to 0.71 and 0.31 meaning they remain subcritical in infinite amounts and thus no mass limits are required. In fresh uranium (un-irradiated or reprocessed) enriched to 94% 235 U by weight, bounding ratios of 234 U, 236U, and 238U exist due to the enrichment process. Utilizing these ratios it is shown that 234 U accounts for less than 0.20 of the total mass fraction of 234 U, 236 U, and 238 U and the remaining 0.80 mass fraction is in a ratio of at least 1:1 for 238 U: 236 U. Creating models conservatively based on these two material limits, the resulting k ∞ = 0.91367 ± 0.00208 suggests a mass limit for 234 U is no longer required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges in Clinical Trial Implementation: Results from a Survey of the National Accreditation Program of Breast Centers (NAPBC)

Background: Although the results of clinical trials often guide best practices, changing clinical practice based on clinical trial results can be challenging. The objective of this study was to examine provider-reported barriers to adopting best clinical practices according to clinical trial data. Methods: A cross-sectional survey was conducted of providers from the National Accreditation Program for Breast Centers about barriers that prevent the incorporation of trial findings. Descriptive analyses and multivariable analyses were performed to determine provider characteristics that were significantly associated with reported barriers. Results: Overall, 383 institutions participated (63.5% response rate), with a total of 1226 physicians responding to the survey (80% response rate). Providers identified national guidelines and meetings as the most compelling way to receive practice-changing information. They reported the following internal barriers to trial implementation: patient preference (45%), strongly held beliefs by partners/colleagues (37%), and insufficient time to discuss new practices (30%). External barriers preventing trial implementation included a lack of agreement from multidisciplinary tumor boards (32%), fear of reimbursement loss (23%), and resistance from clinical staff (20%). Reported barriers differed by provider specialty, with plastic surgeons and radiation oncologists reporting that strongly held beliefs by partners/colleagues and disagreement from multidisciplinary tumor boards were the most significant factors preventing clinical trial implementation. Conclusions: Physician beliefs and patient preferences are the most frequently reported barriers to clinical trial implementation. Tactics to better educate providers about how to explain new clinical trial data to their patients and colleagues are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Derivation of Capabilities and Resources for Treating Medical Conditions in Deep Space

BACKGROUND: Medical care in spaceflight requires the adaptation of terrestrial standards to the constraints of the space environment. However, there is often conflict between the ideal resources required for treatment and diagnosis of a medical condition, and the constraints on their mass, volume, data needs, etc. This optimization of trades between medical risk and resources will be a significant challenge for deep space medical system design. METHODS: A team of physicians with a broad range of expertise reviewed the 120 medical conditions on the condition list for NASA’s Informing Mission Planning via analysis of Complex Tradespaces Medical Database (IMPACT-MD). Each team member was assigned a subset of conditions based on their experience and training. The assigned physician generated a proposed list of capabilities, definitions, and resources required to treat each condition based on terrestrial practice guidelines, medical literature, and subject matter expertise. Additional specialists were consulted for conditions where expertise was not present within the main group. The proposed list was then reviewed by the broader team and modified as needed to achieve consensus. Each capability and resource was then assigned parameters to define quantity required per medical event, necessity, training level required, and primacy order of any alternative resources. These capabilities and resources were placed into condition specific tables and delivered to a team of engineers who added mass and volume data for each specific resource and converted the table into a database for use as input to a computational model to simulate spaceflight (IMPACT) DISCUSSION: This process ensures that a minimum of three subject matter experts review and agree upon the scope of practice, medical diagnostic tools, and treatment modalities that would be necessary to address emergent and non-emergent conditions that may arise during spaceflight to inform requirements during the vehicle design phase. The method is scalable to any design reference mission and permits modification of the existing database as information, conditions or experience are added. By including specialists, generalists, and those with subject matter expertise in the spaceflight environment on the team, we ensure that the included capabilities represent a realistic and actionable foundation for planning deep space missions.

D R Levin↗

FAIR Data and Interpretable AI Framework for Architectured Metamaterials

Our interdisciplinary effort successfully generated FAIR (Findable, Accessible, Interoperable, and Reusable) benchmark datasets for mechanical metamaterials while introducing a novel Artificial Intelligence (AI) framework known as Learning Refined Compositional Rules (LRCR). This framework was specifically designed to bridge the gap across varying computational length scales and extract the underlying physical mechanisms that connect a material's structural geometry to its bulk acoustic properties. Historically, the discovery of such structured materials relied heavily on human intuition or opaque, black-box optimization algorithms that were difficult to generalize. By combining interpretable machine learning techniques with rigorous experimental validation, this project established clear, generalizable design guidelines for tuning wave dispersion and controlling vibrations. Ultimately, the public availability of these structured datasets and algorithms will significantly reduce computational costs and accelerate the design of advanced multi-functional acoustic devices, offering broad societal impacts across fields like aerospace engineering, telecommunications, and biomedical implant design.

36 MATERIALS SCIENCE↗

Submarine exposure guideline recommendations for carbon dioxide based on the prenatal developmental effects of exposure in rats

Background To protect crewmember health, the U.S. Navy sets exposure limits for more than 200 components of submarine atmospheres. The addition of females to nuclear submarines required a reevaluation of these exposure limits, originally established for all‐male crews. In the case of carbon dioxide (CO 2 ), the only available data suitable for deriving an exposure limit were from a 2010 study sponsored by the British Royal Navy that reported a debatable interpretation casting doubt on whether current U.S. Navy exposure limits served to protect fetal developmental health. Methods About 120 time‐mated female Sprague–Dawley rats (Crl: CD[SD]) were exposed to CO 2 at levels of 1.5%, 2.0%, 2.5%, and 3.0% from gestation days 6 to 20. Dams were euthanized and fetuses were examined. Results Findings with implications for exposure limits for CO 2 during pregnancy were an increased mean litter proportion of early resorptions and a lower mean litter proportion of viable fetuses in the 3.0% CO 2 group. Conclusion The results yield a No Observed Adverse Effect Level (NOAEL) of 2.5% and a Lowest Observed Adverse Effect Level (LOAEL) of 3.0%. The results reasonably allow a point of departure of 2.5% CO 2 for deriving an exposure recommendation. An interspecies uncertainty factor was applied to derive a recommended 90‐day continuous exposure limit (CEL) of 0.8% for CO 2 . As reproductive endpoints that are developmental in nature must be assumed to result from a single exposure at a critical point during gestation, it is further recommended that the 24‐hr emergency exposure limit (EEL) also be 0.8%.

Howard, William R.↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)