Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Iodide Sorption to Clays and the Relationship to Surface Charge and Clay Texture - 12356

Iodine is assumed to behave conservatively in clay barriers around nuclear waste repositories and in natural sediments. Batch experiments tend to show little to no sorption, while in column experiments iodine is often retarded relative to tritiated water. Current surface complexation theory cannot account for negatively charged ion sorption to a negatively charged clay particle. Surface protonation and iodide sorption to clay minerals were examined using surface titrations and batch sorption experiments with a suite of clay minerals. Surface titrations were completed spanning a range of both pH values and ionic strengths. For reference, similar titrations were performed on pure forms of an Al-O powder. The titration curves were deconvoluted to attain the pKa distribution for each material at each ionic strength. The pKa distribution for the Al-O shows two distinct peaks at 4.8 and 7.5, which are invariant with ionic strength. The pKa distribution of clays was highly variable between the different minerals and as a function of ionic strength. Iodide sorption experiments were completed at high solid:solution ratios to exacerbate sorption properties. Palygorskite and kaolinite had the highest amount of iodide sorption and montmorillonite had the least. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applications of Transient Grating Spectroscopy to Radiation Materials Science

Radiation damage is an inherently multi-scale phenomenon, with much of the key material evolution occurring at the mesoscale. Current techniques for the direct interrogation of material property changes due to irradiation either function with very small volumes, such as in-situ TEM, cannot cover the full range of defect populations produced, such as in positron annihilation spectroscopy, or requires destruction of the test material, such as in standard or micromechanical testing. In addition, the ultimate quantities of interest to radiation materials scientists are the changes in key material properties with irradiation. These include stiffness, ductility, and thermal conductivity for structural materials, and optical properties such as index of refraction or changes in transmittance spectra for optically active materials. The latter of these are often correlated directly to stress- or thermally-induced changes, themselves a function of the specific defect populations responsible for their change. The rapid study of such a mesoscale phenomenon requires an inherently mesoscale technique, where multiple quantities of interest can be accurately measured in very short times. Determining the sensitivity of any technique with known certainly is of critical importance to qualifying a new technique to measure in-situ material property changes during irradiation. In this paper, we present the new applicability of an existing technique, known as transient grating (TG) spectroscopy, to rapidly and accurately study key problems in radiation materials science. Results quantifying the absolute sensitivity of the technique are presented, alongside molecular dynamics (MD) simulations of the TG spectroscopy process to gauge direct agreement between theory, simulation, and experiment. An example problem of interest is demonstrated as an illustration of what is possible, showing elastic and thermal changes in irradiated silicon carbide (SiC) films. Finally, future work to quantify the effects of experimentally-simulated radiation defects is proposed, in support of building a database to use TG spectroscopy to deconvolve irradiated material property changes in-situ in terms of the defect populations responsible for their evolution. The application of the TG spectroscopy technique to in-situ radiation materials science has the potential to answer long-standing questions in the field, relating to ion beam rastering, the onset of void swelling, and direct measurement of radiation-created point defect concentrations. Before it can do so, the technique must carefully be analyzed and tuned to increase its sensitivity, the certainty of its results, and the ability to predict radiation-induced changes by simulations must be developed. Making such measurements in-situ with the aid of predictive MD simulations has the potential to elucidate mechanisms of radiation damage accumulation, as well as more rapidly qualify radiation-resistant alloys for service in nuclear systems. Work is underway to build this database of experimentally-simulated radiation-produced defects, which will be combined and compared with actual irradiated materials for eventual in-situ deconvolution of the TG signal into the defect populations responsible for irradiation-induced microstructural change. (authors)

36 MATERIALS SCIENCE↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary neutron yields from thick-target GCR accelerator experiments - 25434

This work overviews recent experiments conducted at the NASA Space Radiation Laboratory which sought to experimentally verify model predictions of an optimal spacecraft shielding thickness and provide data which can be used to quantify uncertainties in the physics models within the standard particle transport codes which presently, in some places, poorly predict data and whose results can vary significantly from code to code. Now that the multi-year experiment campaign is complete, some of the overarching trends in the data can be studied; though this work only provides a cursory look at these overarching trends. A small set of the neutron yields measured in these experiments are showcased here. The experiment employed two thick targets along a beamline to emulate the walls of a spacecraft being bombarded by galactic cosmic rays. Time-of-flight techniques were used to characterize neutrons produced in the upstream target while a novel pulse height deconvolution methodology was developed and implemented to characterize neutrons produced in the downstream target. (authors)

43 PARTICLE ACCELERATORS↗

Digitalized two parametric system for gamma/neutron spectrometry - Paper 59

Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new dose assessment method for the UK system of criticality accident dosimetry - 14420

A new method for the measurement and interpretation of the Harwell criticality accident dosemeter has been developed. The new method treats the dosemeter components as individual detector elements with unique energy-dependent response functions generated with MCNP6. A bespoke deconvolution code was written that generates a parameterized neutron spectrum from the integral activities in each detector element. The spectrum can be folded with any set of fluence-to-dose conversion coefficients to determine an integral dose. The new method has been validated computationally using realistic neutron spectra and experimentally in a series of test irradiations using the Godiva-IV, CALIBAN and PROSPERO critical assemblies. The method was able to reproduce the true dose with a small positive bias and a combined relative uncertainty of 25 % across the full range of spectra considered (10 pGy cm{sup 2} to 45 pGy cm{sup 2}). (authors)

42 ENGINEERING↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was ~80, ~65, ~50 and ~35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of ~95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was ~105, ~90, ~85, ~ 80, and ~70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion occurs.

Mainali, Badri↗

Pre-Test Feasibility Study Of Reactivity Transient Testing On TRISO Fuel In The TREAT Reactor

Uranium oxycarbide (UCO)-bearing tri-structural isotropic (TRISO) particle fuels are expected to be used in numerous US commercial reactor applications within the next decade. In this work, we reviewed historical particle fuel transient experiments to identify gaps in the TRISO fuel performance transient testing. A BISON--Griffin modeling framework was then developed to conduct preliminary TRISO transient analyses and begin to address these gaps. The framework was demonstrated using limiting-case transient conditions from a prototypic high-temperature gas-cooled reactor. It was then applied to develop a matrix of experiments that could be performed in the Transient Reactor Test Facility (TREAT) to (1) evaluate UCO-fueled particle performance at moderate and high heat rates, (2) assess whether historical testing involving UO$_2$-fueled particles is applicable to modern UCO-fueled particles, (3) deconvolute the impacts of temperature and heat rate on particle transient response, and (4) collect the data needed for fuel performance model validation and/or further development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

Non-Classical Creep Behavior of Fusion-Cast Alumina Refractories

The compressive creep behavior of a typical 50% -/50% -alumina fusion-cast refractory block was examined as a function of temperature. Test temperatures (1450-1650oC) were chosen to correspond to those typical of service conditions, while relatively high compressive test stresses (0.6 and 1.0 MPa compared to 0.2-0.4 MPa which is typical of service) were chosen to promote exaggerated deformation and to more accurately measure the resulting creep strain. It was found that the measured creep strain responses in this alumina were a sum of (contracting) compressive creep strain and expansion strain due to time and temperature dependent microcracking. Long term, isothtermal expansion tests were also conducted, and their results allowed for the deconvolution of the compressive creep and expansion strains present in the measured creep strain test data. The analysis shows that despite complications associated with conflicting expansion and contraction effects, classical creep analysis may be used with this alumina refractory after the strains associated with the non-steady-state mechanism are considered and accounted for.

36 MATERIALS SCIENCE↗

A generalized vector-valued total variation algorithm

We propose a simple but flexible method for solving the generalized vector-valued TV (VTV) functional, which includes both the {ell}{sup 2}-VTV and {ell}{sup 1}-VTV regularizations as special cases, to address the problems of deconvolution and denoising of vector-valued (e.g. color) images with Gaussian or salt-andpepper noise. This algorithm is the vectorial extension of the Iteratively Reweighted Norm (IRN) algorithm [I] originally developed for scalar (grayscale) images. This method offers competitive computational performance for denoising and deconvolving vector-valued images corrupted with Gaussian ({ell}{sup 2}-VTV case) and salt-and-pepper noise ({ell}{sup 1}-VTV case).

99 GENERAL AND MISCELLANEOUS↗

The Octahedral Sheet of Metamorphic 2M 1-Phengites: a Combined EMPA And AXANES Study

Two types of metamorphic phengites are known: one is linked to high pressure and is 3T; the other is 2M{sub 1}, and its composition is linked to rock-compositional constraints. This work investigates the octahedral sheet crystal-chemical differences between the two phengite types. Seven dioctahedral micas were studied: (1) one 3T phengite from an ultrahigh-pressure metagranitoid in the Dora Maira massif, Italy (P {approx} 4.3 GPa, T {approx} 730 C); (2) five 2M{sub 1} phengites from medium-P orthogneisses in the Eastern Alps metamorphic basement, Italy (P {le} 0.7 GPa, T {approx} 500-600 C); and (3) one 2M{sub 1} ferroan muscovite from pegmatite in Antarctica (P {le} 0.2 GPa, T {approx}500 C). All micas display significant extents of celadonite substitution. In particular, the 2M{sub 1}-phengite formulae (calculated on the basis of 11 O) have 0.68 < {sup IV}Al < 0.82 atoms per formula unit (apfu); octahedral atoms are dominated by Al (1.6-1.8 apfu), with minor and variable Fe (0.20-0.35 apfu) and Mg (0.05-0.17 apfu), and very minor Ti, Mn, and Cr. Total octahedral occupancies are slightly above 2.00 apfu, i.e., there seems to be partial occupancy of the third M site. For all micas, we recorded XAFS spectra on mosaics of carefully separated flakes oriented flat on a plastic support that could be rotated so as to account for the polarization of the synchrotron radiation beam, and we processed them on the basis of the AXANES theory. Spectra show angle-dependent absorption variations for Al and Fe, which can be deconvoluted and fitted by dichroic effects. Pre-edges consistently show most Fe to be Fe{sup 3+} and little angle-dependent intensity variations. The 2M{sub 1}-ferroan muscovite from Antarctica displays the same AXANES behavior as 2M{sub 1}-phengites. By contrast, the ultrahigh-pressure 3T-phengite from Dora Maira (having {sup IV}Al = 0.42 apfu, and Al and Mg as the dominant octahedral constituents) has XAFS spectra that differ significantly. Not only is the {sup IV}Al feature strongly reduced, in agreement with the increased Si content, but also Fe XAFS spectra show one broad feature only, indicating that all Fe is Fe{sup 2+} in a fully disordered distribution with no angle-dependent variations. We conclude that this 3T-phengite is actually contaminated by exsolved Fe-bearing pyrope platelets, which cannot be resolved under SEM examination; by contrast, the 2M{sub 1}-phengites, unrelated to high-pressure, suggest Al/Fe{sup 3+} order over the M1 and (M2, M3) sites, as also does the 2M{sub 1} pegmatitic muscovite.

43 PARTICLE ACCELERATORS↗

Phase Characteristics of a U-20Pu-3Am-2Np-15Zr Metallic Alloy Containing Rare Earths

Metallic fuel alloys consisting of uranium, plutonium, and zirconium with minor additions of americium and neptunium are under evaluation for potential use to transmute long-lived transuranic actinide isotopes in fast reactors. The current irradiation test series design, designated AFC2, includes minor additions of rare earth elements to simulate expected fission product carry-over from the electrochemical molten salt reprocessing technique. The metal fuel alloys have been fabricated by an arc casting technique. The as-cast fuel alloys have been investigated for phase and thermal properties, specifically, enthalpies of transition, transition temperatures, and room temperature phase characteristics. Results and observations related to these characteristics for the “fresh” fuel alloys are provided. The alloy compositions are based on a U-20Pu-3Am-2Np-15Zr alloy, along with additions of 1 and 1.5 wt% RE (at the expense of U) where RE denotes rare earth alloy of cerium, lanthanum, praseodymium and neodymium). Phase behavior and associated transitions have been compared to available U-Pu-Zr ternary diagrams with acceptable agreement. Enthalpies of transition were deconvoluted from heating and cooling thermal traces for relatively reliable values. The rare earth additions to the base alloy have a minimal influence on the room temperature phases present, but the room temperature phases present slightly impacted the enthalpies of transition and transition temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasound spectroscopy: application on MMC and PMC materials

Resonant Ultrasound Spectroscopy (RUS) is a simple technique for measuring the second-order elastic constants and ultrasonic attenuation of solids. The technique is based on measuring the spectrum of mechanical resonances for a sample of known shape (usually a sphere, cylinder, or parallelepiped). This spectrum cannot be deconvoluted to deduce the elastic constants. Instead, an approximate spectrum is calculated from the known sample dimensions, its mass, and a set of 'guessed' elastic constants. A multidimensional minimization of the rms difference between the measured and calculated spectra enables us to deduce all the elastic constants of the solid from a single frequency scan. Currently, the technique can be applied to crystals of orthorhombic symmetry (9 elastic constants) or higher using desktop computers and software developed for this purpose. Composite materials, especially fiber composites, can take full advantage of the RUS technique as they typically have low symmetry. In this paper we summarize the RUS technique and provide examples of its application to the elastic characterization of both fiber reinforced MMC's, and fiber reinforced PMC's.

36 MATERIALS SCIENCE↗

Ionization electron signal processing in single phase LArTPCs. Part I. Algorithm Description and quantitative evaluation with MicroBooNE simulation

Here, we describe the concept and procedure of drifted-charge extraction developed in the MicroBooNE experiment, a single-phase liquid argon time projection chamber (LArTPC). This technique converts the raw digitized TPC waveform to the number of ionization electrons passing through a wire plane at a given time. A robust recovery of the number of ionization electrons from both induction and collection anode wire planes will augment the 3D reconstruction, and is particularly important for tomographic reconstruction algorithms. A number of building blocks of the overall procedure are described. The performance of the signal processing is quantitatively evaluated by comparing extracted charge with the true charge through a detailed TPC detector simulation taking into account position-dependent induced current inside a single wire region and across multiple wires. Some areas for further improvement of the performance of the charge extraction procedure are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗