Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A comprehensive analysis of electron conical distributions from multi-satellite databases

This report consists of a copy of a paper that has been submitted to the 'Journal of Geophysical Research', entitled 'DE 1 and Viking Observations Associated With Electron Conical Distributions,' and an abstract of another paper (included as an appendix to the report) that is about to be submitted to the same journal entitled 'Perpendicular Electron Heating by Absorption of Auroral Kilometric Radiation.' A bibliography of other papers that have been published as a result of this project follows. The purpose of this project was to use the DE 1 and Viking particle and wave data to better understand the source mechanism of electron conical distributions. We have shown that electron conics are often associated with upper hybrid waves in the nightside auroral region. We have also shown that electron conics are observed near auroral kilometric radiation (AKR) source regions and may be the result of perpendicular heating due to waves. We have completed a statistical study of electron conics observed by DE-l and Viking. The study shows the occurrence frequency and location of electron conical distributions; there are some differences between the results of DE and Viking perhaps due to different regions sampled.

Menietti, J. Douglas↗

Small, Optically-Driven Power Source

Power transmitted along fiber-optic cables. Transmitted as infrared light along fiber-optic cable, converted to electricity to supply small electronic circuit. Power source and circuit remains electrically isolated from each other for safety or reduces electromagnetic interference. Array of diodes made by standard integrated-circuit techniques and packaged for mounting at end of fiber-optic cable.

Cockrum, Richard H.↗

Ion beam production with sub-milligram samples of material from an ECR source for AMS

Current accelerator mass spectrometry experiments at the Argonne Tandem Linac Accelerator System facility at Argonne National Laboratory push us to improve the ion source performance with a large number of samples and a need to minimize cross contamination. These experiments can require the creation of ion beams from as little as a few micrograms of material. These low concentration samples push the limit of our current efficiency and stability capabilities of the electron cyclotron resonance ion source. A combination of laser ablation and sputtering techniques coupled with a newly modified multi-sample changer has been used to meet this demand. We will discuss performance, stability, and consumption rates as well as planned improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High intensity high charge state ion beam production with an evaporative cooling magnet ECRIS

LECR4 (Lanzhou ECR ion source No. 4) is a room temperature electron cyclotron resonance ion source, designed to produce high current, high charge state ion beams for the SSC-LINAC injector (a new injector for sector separated cyclotron) at the Institute of Modern Physics. LECR4 also serves as a PoP machine for the application of evaporative cooling technology in accelerator field. To achieve those goals, LECR4 ECR ion source has been optimized for the operation at 18 GHz. During 2014, LECR4 ion source was commissioned at 18 GHz microwave of 1.6 kW. To further study the influence of injection stage to the production of medium and high charge state ion beams, in March 2015, the injection stage with pumping system was installed, and some optimum results were produced, such as 560 eμA of O{sup 7+}, 620 eμA of Ar{sup 11+}, 430 eμA of Ar{sup 12+}, 430 eμA of Xe{sup 20+}, and so on. The comparison will be discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. A hydrogen ion source is described which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency.

Sovey, J. S.↗

A hollow cathode hydrogen ion source

High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. This paper describes a hydrogen ion source which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency. A 1.3-cm-diam hollow cathode using a low work function material dispenser performed satisfactorily over a discharge current range of 10-90 A. Cylindrical probe measurements taken without ion extraction indicate maximum ion number densities on the order of 10 trillion/cu cm. Discharge durations ranged from 30 sec to continuous operation. Tests with beam extraction at 2.5 keV and 30 A discharge current yield average ion beam current densities of 0.1 A/sq cm over a 5-cm extraction diameter. Results of this study can be used to supply the baseline information needed to scale hollow cathodes for operation at discharge currents of hundreds of amperes using distributed cathodes.

Sovey, J. S.↗

Theoretical study of the effect of ionospheric return currents on the electron temperature

A time-dependent, three-dimensional model of the high-altitude ionosphere is presently used to study the effects of field-aligned ionospheric return currents on auroral electron temperatures for different seasonal and solar cycle conditions, as well as for different upper boundary heat fluxes. The average, large scale, return current densities, which are a few microamps/sq m, are too small to affect auroral electron temperatures. The thermoelectric effect exhibits a pronounced solar cycle and seasonal dependence, and its heat transport corresponds to an upward flow of electron energy which can be either a source or sink of electron energy depending on altitude and geophysical conditions.

Schunk, R. W.↗

A quality monitor and monitoring technique employing optically stimulated electron emission

A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.

Yost, William T.↗

Time resolved detection of two-plasmon decay using three-halves harmonic emission on the National Ignition Facility

Supra-thermal (>100 keV) electrons generated by laser plasma interactions can be detrimental to the performance of ignition experiments conducted on the National Ignition Facility (NIF). On a NIF shot, the amount of electrons is estimated by measuring the hard X-rays passing through the hohlraum wall. The primary sources of hot electrons in a hohlraum are Stimulated Raman Scattering (SRS) and two plasmon decay (TPD). While SRS is well diagnosed on the NIF, there has been no diagnosis of TPD. Here we have designed and implemented a new diagnostic to characterize the time history of TPD on the NIF. The instrument provides a time resolved measurement of the 3/2 ω harmonic emission which is indicative of the presence of TPD. We describe the diagnostic setup, calibration, and the preliminary results obtained on NIF hohlraum experiments. Finally, we find evidence of a correlation between measured hard X-rays generated from the hot electron bremsstrahlung and the TPD emission.

47 OTHER INSTRUMENTATION↗

Electrochirogenesis: The Possible Role of Low-Energy Spin-Polarized Electrons in Creating Homochirality

Electrochirogenesis deals with the induction of chirality by polarized electrons of which those with low energy (<15 eV) are seen to be the most effective. Possible sources of such electrons in the prebiotic universe are discussed and several examples where chiral induction by these electrons have been demonstrated are given. Finally, some possible scenarios where electrochirogenesis could have played a role in forming a chiral imbalance in a prebiotic setting have been speculated on and some possible future areas of research proposed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical properties of ion beam textured metals

Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8 cm diameter electron bombardment ion source. Simultaneously sputter-deposited tantalum was used to facilitate the development of the surface microstructure. Scanning electron microscopy of the ion textured surfaces revealed two types of microstructure. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Spectral reflectance was measured using an integrating sphere and a holraum reflectometer. Total reflectance for air mass 0 and 2, solar absorptance and total emittance normalized for a 425 K black body were calculated from the reflectance measurements.

Hudson, W. R.↗

SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose is accurately and consistently delivered to patients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Features of ion generation by a picosecond laser in the range of 10 11 –10 13 W cm -2 power densities

Picosecond lasers (ps-lasers) have significant advantages for the generation of low charge state ions compared to nanosecond lasers because the influence of heat conductivity on a solid target is almost negligible in the case of ps-laser ablation for laser pulse durations less than 10 ps. However, there is no comprehensive data on ion yields for different elements and target irradiation conditions for laser power densities at the target surface around and below 10 13 W cm –2 , which is of interest to our study of such plasmas as a source of low charge state ions for various applications, particularly for external injection of those ions into an Electron Beam Ion Source (EBIS). We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a ps-laser with power densities in the range of 10 11 –10 13 W cm –2 at the target surface. A ps-laser with 1.27 mJ maximum energy within an 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current versus time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increases linearly with increasing laser pulse energy and is almost independent of the target element and number of shots onto the same target spot for all five target elements studied. The results obtained give us a basis for specification and design of the source of low charge state ions for external injection into EBIS.

43 PARTICLE ACCELERATORS↗

Kinetics of metastable atoms and non-Maxwellian electrons in two-temperature plasmas

Numerical and analytical solutions of the electron Boltzmann equation in two-temperature steady-state helium plasma are studied in a broad range of conditions T(a) = 5,000-20,000 K, T(e) = 10,000-20,000 K; N(a) = 10 to the 10th - 10 to the 18th per cu cm. The WKB analytical solution is found to be satisfactory in most situations. The deviation of the electron distribution from Maxwellian and a possibility of raising of the tail of the distribution in presence of sources of fast electrons is also discussed.

Kunc, J. A.↗

Millisecond radio spikes from the dwarf M flare star AD Leonis

Arecibo radio observations of millisec bursts of radio signals at 1415 MHz from AD Leonis are reported. The observed burst had an ellipticity of 0.95, 50-100 percent circular polarization, and a flux density maximum of 30 mJy. The 50 sec burst featured five quasi-periodic oscillations with a mean periodicity of about 3.2 sec. A second, less intense burst that occurred 20 sec later was 100 percent circularly polarized. The area emitting the bursts covered an estimated 0.005 of the radius of AD Leonis and had an electron density of 6 billion/cu cm and a longitudinal magnetic field strength of 250 gauss, if the source was an electron-cyclotron maser. A coherent plasma source would require, for the first harmonic, an electron density of 20 billion/cu cm and a magnetic field much less than 500 gauss. A second harmonic of the plasma frequency would require an electron density of 6 billion/cu cm and a field strength much less than 250 gauss. The possibility that the source was periodic oscillations in coronal loops is discussed.

Lang, K. R.↗

Bulk plasma fragmentation in a C{sub 4}F{sub 8} inductively coupled plasma: A hybrid modeling study

A hybrid model is used to investigate the fragmentation of C{sub 4}F{sub 8} inductive discharges. Indeed, the resulting reactive species are crucial for the optimization of the Si-based etching process, since they determine the mechanisms of fluorination, polymerization, and sputtering. In this paper, we present the dissociation degree, the density ratio of F vs. C{sub x}F{sub y} (i.e., fluorocarbon (fc) neutrals), the neutral vs. positive ion density ratio, details on the neutral and ion components, and fractions of various fc neutrals (or ions) in the total fc neutral (or ion) density in a C{sub 4}F{sub 8} inductively coupled plasma source, as well as the effect of pressure and power on these results. To analyze the fragmentation behavior, the electron density and temperature and electron energy probability function (EEPF) are investigated. Moreover, the main electron-impact generation sources for all considered neutrals and ions are determined from the complicated C{sub 4}F{sub 8} reaction set used in the model. The C{sub 4}F{sub 8} plasma fragmentation is explained, taking into account many factors, such as the EEPF characteristics, the dominance of primary and secondary processes, and the thresholds of dissociation and ionization. The simulation results are compared with experiments from literature, and reasonable agreement is obtained. Some discrepancies are observed, which can probably be attributed to the simplified polymer surface kinetics assumed in the model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma-wakefield accelerator simultaneously boosts electron beam energy and brightness

High-energy particle colliders and X-ray free-electron lasers demand electron beams with qualities currently achieved only in kilometer-scale radio-frequency accelerators. Plasma accelerators promise a compact alternative but have faced challenges in delivering the needed beam quality at relevant energies. Here, we demonstrate that a plasma-wakefield accelerator operating in the nonlinear regime acts as a transformer to simultaneously boost the energy and brightness of an electron bunch injected from the plasma. Using a 10-GeV drive bunch and a three-stage meter-scale plasma source, we generated electron bunches exceeding 20 GeV with sub-percent energy spread, 2 mm·mrad normalized emittance, and multi-kA peak current. A significant number of drive-bunch electrons lost over 90% of their energy, a prerequisite for high energy-conversion efficiency. This demonstration of an energy transformer ratio exceeding two and a brightness enhancement over an order of magnitude opens a path towards cost-effective accelerators for future colliders and light sources.

experimental particle physics↗