Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Long-run Marginal Emission Rates for Electricity - Workbooks for 2023 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States' electric sector. A LRMER is an estimate of the rate of emissions that would be either induced or avoided by a change in electric demand, taking into account how the change could influence both the operation as well as the structure of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). These workbooks provide data for 18 GEA regions covering the contiguous United States. Mappings of these regions to ZIP codes and counties is given in this workbook in the corresponding tabs. For more data underlying these emissions factors, see the Cambium 2023 project at https://scenarioviewer.nrel.gov/. For more details on input assumptions and methodology see the associated report (Cambium 2023 Scenario Descriptions and Documentation, https://www.nrel.gov/docs/fy24osti/88507.pdf). Users are advised to review section 4 of the report, which discusses limitations and caveats of the data. This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

ChargeX OCPI Recommendations

The Open Charge Point Interface (OCPI) is an open protocol that enables electric vehicle (EV) charging systems to work together across networks. It supports communication and data sharing between Charge Point Operators (CPOs), who manage charging stations, and e-Mobility Service Providers (eMSPs), who provide charging services to EV drivers. OCPI facilitates functions like user authorization, remote charge point control, charging session data exchange, and billing through Charge Detail Records (CDRs). This allows EV roaming, so drivers can charge at different networks without multiple accounts. As the EV market grows due to increased adoption and technological advancements, OCPI faces higher demands. This has revealed issues with CDR format consistency, timestamp standardization across regions, transmission of EV-side error codes for troubleshooting, and support for new use cases. These challenges can affect operations and user experience, particularly as the industry starts considering Vehicle-to-Grid (V2G) systems, where EVs supply energy to the grid, and Vehicle-to-Everything (V2X) technologies for broader energy interactions. Using feedback from the ChargeX Diagnostics taskforce discussions, industry 1-on-1 meetings, technical standards, and OCPI’s evolution through versions (e.g., OCPI 2.1.1, 2.2, and 2.2.1), this report identifies these issues and suggests practical recommendations. These aim to improve interoperability, streamline operations, and prepare OCPI for future trends in the EV charging ecosystem.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Strategy Guideline: Compact Air Distribution Systems

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft 2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Update on the United States Advanced Ultra-Supercritical Program with Full Scale Component Fabrication to Develop Utility Scale Power Plants with 760°C Steam Temperature

Following the successful completion of a 15-year effort to develop and test materials that would allow coal-fired power plants to be operated at advanced ultra-supercritical (A-USC) steam conditions, a United States-based consortium is presently engaged in Phase 2 of a project which includes an advanced manufacturing effort to complete US-based supply chain development for full commercial scale (800-850 MWe) A-USC components made of nickel-based alloys, components operating at up to 760°C. The project, funded under U.S. Department of Energy Award No. DE-FE0025064, falls under the US DOE overall goal to Develop cost-effective, reliable technologies to improve the efficiency of new and existing coal-fired power plants. A-USC steam cycles have the potential to improve cycle efficiency, reduce fuel costs, and reduce greenhouse gas emissions. Current development and demonstration efforts are focused on enabling the construction of A-USC plants, operating with steam temperatures as high as 1400°F (760°C) and steam pressures up to 5000 psi (35 MPa), which can potentially increase cycle efficiencies to 47% HHV (higher heating value), or approximately 50% LHV (lower heating value), and reduce CO 2 emissions by roughly 25%, compared to today’s U.S. fleet. A-USC technology provides a lower-cost method to reduce CO 2 emissions, compared to CO 2 capture technologies, while retaining a viable coal option for owners of coal generation assets. Among the specific goals of Phase 2 of the ComTest Project are to: validate that components made from advanced nickel-based alloys can operate and perform under A-USC conditions accelerate the development of a U.S.-based supply chain for the full complement of A-USC components close the remaining gaps and reduce the risks for manufacturing components from advanced materials for commercial demonstration fabricate full-scale versions of selected key components made of nickel-based alloys validate a qualified U.S. supply chain, to provide greater cost certainty for components obtain American Society of Mechanical Engineers (ASME) code approval for new materials, components and processes Additional benefit: Manufacturing technology will be applicable to other advanced fossil energy high temperature cycles, and can support increased flexibility of existing power plants The ComTest project is managed by Energy Industries of Ohio, and technically directed by the Electric Power Research Institute, Inc., with General Electric designing the A-USC components. As stated earlier, the current phase of the effort is primarily funded by the U.S. Department of Energy, through the National Energy Technology Laboratory. This presentation outlines the motivation for the project, explains the project’s structure and schedule, and provides some of the technical details on the design of the ComTest components.

01 COAL, LIGNITE, AND PEAT↗

Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries

Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present paper, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10 -9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Finally and overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

SPLIT: Stable Protein Coacervation Using a Light Induced Transition

Protein coacervates serve as hubs to concentrate and sequester proteins and nucleotides and thus function as membraneless organelles to manipulate cell physiology. We have engineered a coacervating protein to create tunable, synthetic membraneless organelles that assemble in response to a single pulse of light. Coacervation is driven by the intrinsically disordered RGG domain from the protein LAF-1, and opto-responsiveness is coded by the protein PhoCl, which cleaves in response to 405 nm light. We developed a fusion protein containing a solubilizing maltose-binding protein domain, PhoCl, and two copies of the RGG domain. Several seconds of illumination at 405 nm is sufficient to cleave PhoCl, removing the solubilization domain and enabling RGG-driven coacervation within minutes in cellularsized water-in-oil emulsions. An optimized version of this system displayed light-induced coacervation in Saccharomyces cerevisiae. Finally, the methods described here provide novel strategies for inducing protein phase separation using light.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An empirical relationship for extrapolating sparse experimental lap joint data.

Correctly incorporating the influence of mechanical joints in built-up mechanical systems is a critical element for model development for structural dynamics predictions. Quality experimental data are often difficult to obtain and is rarely sufficient to determine fully parameters for relevant mathematical models. On the other hand, fine-mesh finite element (FMFE) modeling facilitates innumerable numerical experiments at modest cost. Detailed FMFE analysis of built-up structures with frictional interfaces reproduces trends among problem parameters found experimentally, but there are qualitative differences. Those differences are currently ascribed to the very approximate nature of the friction model available in most finite element codes. Though numerical simulations are insufficient to produce qualitatively correct behavior of joints, some relations, developed here through observations of a multitude of numerical experiments, suggest interesting relationships among joint properties measured under different loading conditions. These relationships can be generalized into forms consistent with data from physical experiments. One such relationship, developed here, expresses the rate of energy dissipation per cycle within the joint under various combinations of extensional and clamping load in terms of dissipation under other load conditions. The use of this relationship-though not exact-is demonstrated for the purpose of extrapolating a representative set of experimental data to span the range of variability observed from real data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Calculating Design Heating Loads for Superinsulated Buildings, Ithaca, New York; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MELCOR Modeling of Accident Scenarios at a Facility for Aqueous Reprocessing of Spent Nuclear Fuel

The work presented in this report applies the MELCOR code to evaluate potential accidents in non-reactor nuclear facilities, focusing on Design Basis Accidents. Ten accident scenarios were modeled using NRC's best-estimate severe accident analysis code, MELCOR 2.2. The accident scenarios simulated a range of explosions and/or fires related to a nuclear fuel reprocessing facility. The objective was to evaluate the radionuclide source term to the environment following initiating explosion and/or fire events. The simulations were performed using a MELCOR model of the Barnwell Nuclear Fuel Plant, which was decommissioned before beginning reprocessing operations. Five of the accident scenarios were based on the Class 5 Design Basis Accidents from the Final Safety Analysis Report. Three of the remaining accident scenarios include sensitivity studies on smaller solvent fires. The final two accidents included an induced fire from an initial explosion. The radionuclide inventory was developed from ORIGEN calculations of spent PWR fuel with an initial enrichment of 4.5% U-235 by weight. The fuel aged for five years after a final 500-day irradiation cycle. The burn-up was conservatively increased to 60 GWd/MTU to bound current US operations. The results are characterized in terms of activity release to the environment and the building decontamination factor, which is related the leak path factor used in Department of Energy safety analyses. The MELCOR 2.2 results consider adverse consequences to the filters, ventilation system, and structures as a result of the explosions and fires. The calculations also include best-estimate models for aerosol transport, agglomeration, and deposition. The new calculations illustrate best-estimate approaches for predicting the source term from a reprocessing facility accident.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Update on the United States Advanced Ultra-Supercritical Program with Full Scale Component Fabrication to Develop Utility Scale Power Plants with 760°C Steam Temperature

Following the successful completion of a 15-year effort to develop and test materials that would allow coal-fired power plants to be operated at advanced ultra-supercritical (A-USC) steam conditions, a United States-based consortium is presently engaged in Phase 2 of a project which includes an advanced manufacturing effort to complete US-based supply chain development for full commercial scale (800-850 MWe) A-USC components made of nickel-based alloys, components operating at up to 760°C. The project, funded under U.S. Department of Energy Award No. DE-FE0025064, falls under the US DOE overall goal to Develop cost-effective, reliable technologies to improve the efficiency of new and existing coal-fired power plants. A-USC steam cycles have the potential to improve cycle efficiency, reduce fuel costs, and reduce greenhouse gas emissions. Current development and demonstration efforts are focused on enabling the construction of A-USC plants, operating with steam temperatures as high as 1400°F (760°C) and steam pressures up to 5000 psi (35 MPa), which can potentially increase cycle efficiencies to 47% HHV (higher heating value), or approximately 50% LHV (lower heating value), and reduce CO 2 emissions by roughly 25%, compared to today’s U.S. fleet. A-USC technology provides a lower-cost method to reduce CO 2 emissions, compared to CO 2 capture technologies, while retaining a viable coal option for owners of coal generation assets. Among the specific goals of Phase 2 of the ComTest Project are to: validate that components made from advanced nickel-based alloys can operate and perform under A-USC conditions accelerate the development of a U.S.-based supply chain for the full complement of A-USC components close the remaining gaps and reduce the risks for manufacturing components from advanced materials for commercial demonstration fabricate full-scale versions of selected key components made of nickel-based alloys validate a qualified U.S. supply chain, to provide greater cost certainty for components obtain American Society of Mechanical Engineers (ASME) code approval for new materials, components and processes Additional benefit: Manufacturing technology will be applicable to other advanced fossil energy high temperature cycles, and can support increased flexibility of existing power plants The ComTest project is managed by Energy Industries of Ohio, and technically directed by the Electric Power Research Institute, Inc., with General Electric designing the A-USC components. As stated earlier, the current phase of the effort is primarily funded by the U.S. Department of Energy, through the National Energy Technology Laboratory. This presentation outlines the motivation for the project, explains the project’s structure and schedule, and provides some of the technical details on the design of the ComTest components.

01 COAL, LIGNITE, AND PEAT↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid-to-plasma transition of polystyrene induced by a nanosecond laser pulse within the context of inertial confinement fusion

Laser Direct Drive (LDD) Inertial Confinement Fusion (ICF) involves irradiating a spherical target of thermonuclear fuel coated with an ablator, usually made of polystyrene. Laser energy absorption near the target surface leads to matter ablation, hydrodynamic shocks, and ultimately capsule implosion. The conservation of spherical symmetry is crucial for implosion efficiency, yet spatial modulations in laser intensity can induce nonuniformities, causing the laser imprint phenomenon. Understanding laser imprint, especially considering the initial solid state, is essential for advancing LDD ICF. A first microscopic model of solid-to-plasma transition was built in 2019, accounting for laser absorption in the solid state with a band structure based ionization model. This model has been improved to include chemical fragmentation and a more accurate description of electron collision frequency in various matter states. The latest development involves assessing the model reliability by comparing theoretical predictions with experimental observations. Despite the success of this approach, questions remain, leading to further investigations and observations under different irradiation conditions. This work presents an experiment with a nanosecond pulse, taking into account hydrodynamic effects, and measures transmission dynamics over the entire laser beam area to observe two-dimensional effects. As a result, the objective is to adapt the theoretical model, couple it with a hydrodynamic code, and observe additional effects related to the initial solid state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equation-based languages – A new paradigm for building energy modeling, simulation and optimization

Most of the state-of-the-art building simulation programs implement models in imperative programming languages. This complicates modeling and excludes the use of certain efficient methods for simulation and optimization. In contrast, equation-based modeling languages declare relations among variables, thereby allowing the use of computer algebra to enable much simpler schematic modeling and to generate efficient code for simulation and optimization. We contrast the two approaches in this paper. We explain how such manipulations support new use cases. In the first of two examples, we couple models of the electrical grid, multiple buildings, HVAC systems and controllers to test a controller that adjusts building room temperatures and PV inverter reactive power to maintain power quality. In the second example, we contrast the computing time for solving an optimal control problem for a room-level model predictive controller with and without symbolic manipulations. As a result, exploiting the equation-based language led to 2, 200 times faster solution

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗