Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimizer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

The optimal beam-loading in two-bunch nonlinear plasma wakefield accelerators

Abstract Due to the highly nonlinear nature of the beam-loading, it is currently not possible to analytically determine the beam parameters needed in a two-bunch plasma wakefield accelerator for maintaining a low energy spread. Therefore in this paper, by using the Broyden–Fletcher–Goldfarb–Shanno algorithm for the parameter scanning with the code QuickPIC and the polynomial regression together with k -fold cross-validation method, we obtain two fitting formulas for calculating the parameters of tri-Gaussian electron beams when minimizing the energy spread based on the beam-loading effect in a nonlinear plasma wakefield accelerator. One formula allows the optimization of the normalized charge per unit length of a trailing beam to achieve the minimal energy spread, i.e. the optimal beam-loading. The other one directly gives the transformer ratio when the trailing beam achieves the optimal beam-loading. A simple scaling law for charges of drive beams and trailing beams is obtained from the fitting formula, which indicates that the optimal beam-loading is always achieved for a given charge ratio of the two beams when the length and separation of two beams and the plasma density are fixed. The formulas can also help obtain the optimal plasma densities for the maximum accelerated charge and the maximum acceleration efficiency under the optimal beam-loading respectively. These two fitting formulas will significantly enhance the efficiency for designing and optimizing a two-bunch plasma wakefield acceleration stage.

Physics↗

Adaptive pruning-based optimization of parameterized quantum circuits

Abstract Variational hybrid quantum–classical algorithms are powerful tools to maximize the use of noisy intermediate-scale quantum devices. While past studies have developed powerful and expressive ansatze, their near-term applications have been limited by the difficulty of optimizing in the vast parameter space. In this work, we propose a heuristic optimization strategy for such ansatze used in variational quantum algorithms, which we call ‘parameter-efficient circuit training (PECT)’. Instead of optimizing all of the ansatz parameters at once, PECT launches a sequence of variational algorithms, in which each iteration of the algorithm activates and optimizes a subset of the total parameter set. To update the parameter subset between iterations, we adapt the Dynamic Sparse Reparameterization scheme which was originally proposed for training deep convolutional neural networks. We demonstrate PECT for the Variational Quantum Eigensolver, in which we benchmark unitary coupled-cluster ansatze including UCCSD and k -UpCCGSD, as well as the Low-Depth Circuit Ansatz (LDCA), to estimate ground state energies of molecular systems. We additionally use a layerwise variant of PECT to optimize a hardware-efficient circuit for the Sycamore processor to estimate the ground state energy densities of the one-dimensional Fermi-Hubbard model. From our numerical data, we find that PECT can enable optimizations of certain ansatze that were previously difficult to converge and more generally can improve the performance of variational algorithms by reducing the optimization runtime and/or the depth of circuits that encode the solution candidate(s).

Physics↗

Searching for quantum optimal controls under severe constraints

The success of quantum optimal control for both experimental and theoretical objectives is connected to the topology of the corresponding control landscapes, which are free from local traps if three conditions are met: (1) the quantum system is controllable, (2) the Jacobian of the map from the control field to the evolution operator is of full rank, and (3) there are no constraints on the control field. This paper investigates how the violation of assumption (3) affects gradient searches for globally optimal control fields. The satisfaction of assumptions (1) and (2) ensures that the control landscape lacks fundamental traps, but certain control constraints can still prevent successful optimization of the objective. Using optimal control simulations, we show that the most severe field constraints are those that limit essential control resources, such as the number of control variables, the control duration, and the field strength. Proper management of these resources is an issue of great practical importance for optimization in the laboratory. For each resource, we show that constraints exceeding quantifiable limits can introduce artificial traps to the control landscape and prevent gradient searches from reaching a globally optimal solution. These results demonstrate that careful choice of relevant control parameters helps to eliminate artificial traps and facilitate successful optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel general purpose multiobjective optimization framework with application to electron beam dynamics

Particle accelerators are invaluable tools for research in the basic and applied sciences, such as materials science, chemistry, the biosciences, particle physics, nuclear physics and medicine. The design, commissioning, and operation of accelerator facilities is a nontrivial task, due to the large number of control parameters and the complex interplay of several conflicting design goals. The Argonne Wakefield Accelerator facility has some unique challenges resulting from its purpose to carry out advanced accelerator R&D. Individual experiments often have challenging beam requirements, and the physical configuration of the beam lines is often changed to accommodate the variety of supported experiments. The need for rapid deployment of different operational settings further complicates the optimization work that must be done for multiple constraints and challenging operational regimes. One example of this is an independently staged two-beam acceleration experiment which requires the construction of an additional beam line (this is now in progress). The high charge drive beam, well into the space charge regime, must be threaded through small aperture (17.6 mm) decelerating structures. In addition, the bunch length must be sufficiently short to maximize power generation in the decelerator. We propose to tackle this problem by means of multiobjective optimization algorithms which also facilitate a parallel deployment. In order to compute solutions in a meaningful time frame, a fast and scalable software framework is required. In this paper, we present a general-purpose framework for simulation-based multiobjective optimization methods that allows the automatic investigation of optimal sets of machine parameters. Using evolutionary algorithms as the optimizer and opal as the forward solver, validation experiments and results of multiobjective optimization problems in the domain of beam dynamics are presented. Optimized solutions for the new high charge drive beam line found by the framework were used to finish the design of a two beam acceleration experiment. The selected solution along with the associated beam parameters is presented.

43 PARTICLE ACCELERATORS↗

Simulation-Based Parameter Optimization Framework for Large-Scale Hybrid Smart Grid Communications Systems Design

The design of reliable, dynamic, fault-tolerant hybrid smart grid communication networks is a challenge to achieve for autonomous power grids. Hybrid networks use different communications technologies for different area networks. A simulation-based parameter optimization framework is proposed to tune parameters of hybrid communication technologies to achieve the optimal network performance. It consists of three main components: a parallel executor used to speedup a list of simulations; a sampler running simulations using the parallel executor at each generation; and a hybrid stochastic optimization algorithm for tuning configurable parameters of hybrid designs and applications. The proposed hybrid metaheuristic optimization algorithm combines an evolutionary algorithm with a gradient method to quickly achieve an approximately global optimum solution. Three optimization test functions are employed to train the adjustable parameters of the hybrid algorithm. Results show the proposed parameter optimization framework can help the designer choose the right hybrid architecture with an optimal parameter set for a large-scale broadband PLC-WiMAX hybrid smart grid communication network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Simplex Approximate Gradient for Robust Life-cycle Production Optimization: Applied to Brugge Field

In oil and gas production industry, production optimization is a viable technique to maximize the oil/gas production or net present value (NPV). Robust optimization is one type of production optimization techniques where the geological uncertainty of reservoir is considered. When well operating conditions, e.g., well flow rates and bottom-hole pressures, are the optimization variables, ensemble-based optimization (EnOpt) is the most popular ensemble-based algorithm for robust life-cycle production optimization. Recently, however, a superior algorithm, stochastic simplex approximate gradient (StoSAG), was proposed. Finally, the purpose of this study is to provide a theoretical discussion on why StoSAG is generally superior to EnOpt and provide reasonable example (Brugge field) where StoSAG generates estimates of optimal well controls that give a life-cycle net present value (NPV) significantly higher than the NPV obtained from EnOpt.

02 PETROLEUM↗

AN AUTOMATED MACHINE LEARNING-GENETIC ALGORITHM FRAMEWORK WITH ACTIVE LEARNING FOR DESIGN OPTIMIZATION

The use of machine learning (ML)-based surrogate models is a promising technique to significantly accelerate simulation-driven design optimization of internal combustion (IC) engines, due to the high computational cost of running computational fluid dynamics (CFD) simulations. However, training the ML models requires hyperparameter selection, which is often done using trial-and-error and domain expertise. Another challenge is that the data required to train these models are often unknown a priori. In this work, we present an automated hyperparameter selection technique coupled with an active learning approach to address these challenges. The technique presented in this study involves the use of a Bayesian approach to optimize the hyperparameters of the base learners that make up a super learner model. In addition to performing hyperparameter optimization (HPO), an active learning approach is employed, where the process of data generation using simulations, ML training, and surrogate optimization is performed repeatedly to refine the solution in the vicinity of the predicted optimum. The proposed approach is applied to the optimization of a compression ignition engine with control parameters relating to fuel injection, in-cylinder flow, and thermodynamic conditions. It is demonstrated that by automatically selecting the best values of the hyperparameters, a 1.6% improvement in merit value is obtained, compared to an improvement of 1.0% with default hyperparameters. Overall, the framework introduced in this study reduces the need for technical expertise in training ML models for optimization while also reducing the number of simulations needed for performing surrogate-based design optimization.

Owoyele, Opeoluwa↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Near optimal energy selective x-ray imaging system performance with simple detectors

Purpose: This article describes a method to achieve near optimal performance with low energy resolution detectors. Tapiovaara and Wagner [Phys. Med. Biol. 30, 519-529 (1985)] showed that an energy selective x-ray system using a broad spectrum source can produce images with a larger signal to noise ratio (SNR) than conventional systems using energy integrating or photon counting detectors. They showed that there is an upper limit to the SNR and that it can be achieved by measuring full spectrum information and then using an optimal energy dependent weighting. Methods: A performance measure is derived by applying statistical detection theory to an abstract vector space of the line integrals of the basis set coefficients of the two function approximation to the x-ray attenuation coefficient. The approach produces optimal results that utilize all the available energy dependent data. The method can be used with any energy selective detector and is applied not only to detectors using pulse height analysis (PHA) but also to a detector that simultaneously measures the total photon number and integrated energy, as discussed by Roessl et al. [Med. Phys. 34, 959-966 (2007)]. A generalization of this detector that improves the performance is introduced. A method is described to compute images with the optimal SNR using projections in a ''whitened'' vector space transformed so the noise is uncorrelated and has unit variance in both coordinates. Material canceled images with optimal SNR can also be computed by projections in this space. Results: The performance measure is validated by showing that it provides the Tapiovaara-Wagner optimal results for a detector with full energy information and also a conventional detector. The performance with different types of detectors is compared to the ideal SNR as a function of x-ray tube voltage and subject thickness. A detector that combines two bin PHA with a simultaneous measurement of integrated photon energy provides near ideal performance across a wide range of operating conditions. Conclusions: Low energy resolution detectors can be used in energy selective x-ray imaging systems to produce images with near optimal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-F-BRF-08: Intensity Modulation Expanded to Spatio-Temporal Space; IMRT Combined with Optimal Fractionation Schedule

Purpose: Past efforts to improve the therapeutic ratio have focused on a spatial approach where highly conformal radiation dose is given to tumors while minimizing dose to normal tissues, e.g., IMRT, VMAT, and IGRT. However, the fractionation schedule, i.e., a temporal approach to radiotherapy, has been largely overlooked so far in maximizing the therapeutic ratio. We establish a rigorous mathematical spatio-temporal approach to systematically investigate the feasibility and potential benefits of simultaneously optimizing radiation dose distribution in space and time. Methods: Stochastic control formalism is constructed to maximize the average tumor BED by choosing an optimal radiation dose distribution for an optimal number of fractions subject to normal tissue BED constraints. Three separate simulations are run on two groups of phantom cases; 5 cases with prostate cancer and 5 cases with head-and-neck cancer. (1) Conventional IMRT with 70Gy/35fx for head-and-neck, and 81Gy/45fx for prostate, (2) IMRT is done independently from the fractionation schedule optimization (S-model), (3) integrated spatio-temporal approach (I-model) where radiation intensities are simultaneously optimized for the first time ever in space and time. Final tumor BEDs from the three trials are compared in prostate and head-and-neck cases. Results: Numerical simulations show that final tumor BED from I-model is 20–90% larger than conventional IMRT, and 20-50% larger than S-model for head-and-neck cancer with α/β=10 and Tdouble=2–50 days. Final tumor BED from I-model is also 90–140% larger than conventional IMRT, and 20–30% larger than S-model for prostate cancer with α/β=2 and Tdouble=5–80 days. Conclusion: Our spatio-temporal optimization of radiotherapy allows an expansion of search space for the optimal treatment plans to include the temporal distribution of radiation dose in addition to the spatial distribution. Such spatio-temporal approach shows great potential to improve the therapeutic ratio, particularly with fast growing, aggressive tumors with short doubling time and/or low α/β.

60 APPLIED LIFE SCIENCES↗

A GPU-accelerated and Monte Carlo-based intensity modulated proton therapy optimization system

Purpose: Conventional spot scanning intensity modulated proton therapy (IMPT) treatment planning systems (TPSs) optimize proton spot weights based on analytical dose calculations. These analytical dose calculations have been shown to have severe limitations in heterogeneous materials. Monte Carlo (MC) methods do not have these limitations; however, MC-based systems have been of limited clinical use due to the large number of beam spots in IMPT and the extremely long calculation time of traditional MC techniques. In this work, the authors present a clinically applicable IMPT TPS that utilizes a very fast MC calculation. Methods: An in-house graphics processing unit (GPU)-based MC dose calculation engine was employed to generate the dose influence map for each proton spot. With the MC generated influence map, a modified least-squares optimization method was used to achieve the desired dose volume histograms (DVHs). The intrinsic CT image resolution was adopted for voxelization in simulation and optimization to preserve spatial resolution. The optimizations were computed on a multi-GPU framework to mitigate the memory limitation issues for the large dose influence maps that resulted from maintaining the intrinsic CT resolution. The effects of tail cutoff and starting condition were studied and minimized in this work. Results: For relatively large and complex three-field head and neck cases, i.e., >100 000 spots with a target volume of ∼1000 cm{sup 3} and multiple surrounding critical structures, the optimization together with the initial MC dose influence map calculation was done in a clinically viable time frame (less than 30 min) on a GPU cluster consisting of 24 Nvidia GeForce GTX Titan cards. The in-house MC TPS plans were comparable to a commercial TPS plans based on DVH comparisons. Conclusions: A MC-based treatment planning system was developed. The treatment planning can be performed in a clinically viable time frame on a hardware system costing around 45 000 dollars. The fast calculation and optimization make the system easily expandable to robust and multicriteria optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiobiologically optimized couch shift: A new localization paradigm using cone-beam CT for prostate radiotherapy

Purpose: To present a novel positioning strategy which optimizes radiation delivery by utilizing radiobiological response knowledge and evaluate its use during prostate external beam radiotherapy. Methods: Five patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan with one 358° arc was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions. Five representative pretreatment cone beam CTs (CBCT) were selected for each patient. The CBCT images were registered to PCT by a human observer, which consisted of an initial automated registration with three degrees-of-freedom, followed by manual adjustment for agreement at the prostate/rectal wall interface. To determine the optimal treatment position for each CBCT, a search was performed centering on the observer-matched position (OM-position) utilizing a score function based on radiobiological and dosimetric indices (EUD{sub prostate}, D99{sub prostate}, NTCP{sub rectum}, and NTCP{sub bladder}) for the prostate, rectum, and bladder. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The dosimetric indices, averaged over the five patients’ treatment plans, were (mean ± SD) 79.5 ± 0.3 Gy (EUD{sub prostate}), 78.2 ± 0.4 Gy (D99{sub prostate}), 11.1% ± 2.7% (NTCP{sub rectum}), and 46.9% ± 7.6% (NTCP{sub bladder}). The corresponding values from CBCT at the OM-positions were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.8 ± 0.7 Gy (D99{sub prostate}), 12.1% ± 5.6% (NTCP{sub rectum}), and 51.6% ± 15.2% (NTCP{sub bladder}), respectively. In comparison, from CBCT at the ROCS-positions, the dosimetric indices were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.3 ± 0.6 Gy (D99{sub prostate}), 8.0% ± 3.3% (NTCP{sub rectum}), and 46.9% ± 15.7% (NTCP{sub bladder}). Excessive NTCP{sub rectum} was observed on Patient 5 (19.5% ± 6.6%) corresponding to localization at OM-position, compared to the planned value of 11.7%. This was mitigated with radiobiologically optimized localization, resulting in a reduced NTCP{sub rectum} value of 11.3% ± 3.5%. Overall, the treatment position optimization resulted in similar target dose coverage with reduced risk to rectum. Conclusions: These encouraging results illustrate the potential advantage of applying radiobiologically optimized correction for online image-guided radiotherapy of prostate patients.

60 APPLIED LIFE SCIENCES↗

Optimizing Irregular Applications for Energy and Performance on the Tilera Many-core Architecture

Optimizing applications simultaneously for energy and performance is a complex problem. High performance, parallel, irregular applications are notoriously hard to optimize due to their data-dependent memory accesses, lack of structured locality and complex data structures and code patterns. Irregular kernels are growing in importance in applications such as machine learning, graph analytics and combinatorial scientific computing. Performance- and energy-efficient implementation of these kernels on modern, energy efficient, multicore and many-core platforms is therefore an important and challenging problem. We present results from optimizing two irregular applications { the Louvain method for community detection (Grappolo), and high-performance conjugate gradient (HPCCG) { on the Tilera many-core system. We have significantly extended MIT's OpenTuner auto-tuning framework to conduct a detailed study of platform-independent and platform-specific optimizations to improve performance as well as reduce total energy consumption. We explore the optimization design space along three dimensions: memory layout schemes, compiler-based code transformations, and optimization of parallel loop schedules. Using auto-tuning, we demonstrate whole node energy savings of up to 41% relative to a baseline instantiation, and up to 31% relative to manually optimized variants.

irregular applications, energy opttimization, many↗

Hardware-Conscious Optimization of the Quantum Toffoli Gate

While quantum computing holds great potential in combinatorial optimization, electronic structure calculation, and number theory, the current era of quantum computing is limited by noisy hardware. Many quantum compilation approaches can mitigate the effects of imperfect hardware by optimizing quantum circuits for objectives such as critical path length. Few approaches consider quantum circuits in terms of the set of vendor-calibrated operations (i.e., native gates) available on target hardware. This manuscript expands the analytical and numerical approaches for optimizing quantum circuits at this abstraction level. We present a procedure for combining the strengths of analytical native gate-level optimization with numerical optimization. Although we focus on optimizing Toffoli gates on the IBMQ native gate set, the methods presented are generalizable to any gate and superconducting qubit architecture. Our optimized Toffoli gate implementation demonstrates an 18% reduction in infidelity compared with the canonical implementation as benchmarked on IBM Jakarta with quantum process tomography. Assuming the inclusion of multi-qubit cross-resonance (MCR) gates in the IBMQ native gate set, we produce Toffoli implementations with only six multi-qubit gates, a 25% reduction from the canonical eight multi-qubit implementations for linearly connected qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Dose-Optimization Processes Used in Oncology Drug Development to Minimize Toxicity and Maximize Benefit to Patients

This review highlights strategies to integrate dose optimization into premarketing drug development and discusses the underlying statistical principles. Poor dose optimization can have negative consequences for patients, most commonly because of toxicity, including poor quality of life, reduced effectiveness because of inability of patients to stay on current therapy or receive subsequent therapy because of toxicities, and difficulty in developing combination regimens. We reviewed US Food and Drug Administration initial approvals (2019-2021) of small molecules and antibody-drug conjugates for oncologic indications to determine the proportion with a recommended dosage at the maximum tolerated dose or the maximal administered dose, to characterize the use of randomized evaluations of multiple dosages in dose selection, to describe the frequency of dose modifications at the recommended dosage, and to identify case examples that highlight key principles for premarket dose optimization during drug development. Herein, we highlight major principles for dose optimization and review examples of recent US Food and Drug Administration approvals that illustrate how investigation of dose- and exposure-response relationships and use of randomized dose trials can support dose optimization. Although there has been some progress, dose optimization through randomized dose evaluation in oncology trials is not routinely conducted. Dose optimization is essential to ensure that patients receive therapies which maximize efficacy while minimizing toxicity.

Oncology↗

Core Design Optimization of the Westinghouse Lead Fast Reactor

Westinghouse is pursuing an advanced Nuclear Power Plant design based on Lead Fast Reactor (LFR) technology for global commercialization. To achieve an optimal combination of key attributes, such as safety, sustainability, and economic competitiveness, Westinghouse and ANL partnered in developing and applying a formalized core design optimization strategy. An LFR analysis workflow was developed to automate a suite of reactor physics, fuels performance, safety, and economics simulations on a selected LFR concept. The workflow streamlines analysis of a wide range of LFR designs with different dimensions and fuel types to assess their viability and economic performance, significantly reducing human processing time and risks of processing errors. The LFR optimization exercise was defined, resulting in selection of the design constraints (geometric, neutronics, thermo-mechanical, safety, thermal-hydraulics, and economics) and performance metrics researched (minimization of both the fuels LCOE and the first core inventory cost). A total of 14 varied design parameters were considered, including assembly dimensions, coolant temperature, and enrichment distribution throughout the core. The LFR analysis workflow was connected to DAKOTA for sensitivity and optimization analyses. Due to the extremely large size of the potential LFR optimization solution space relative to the computing time required to characterize one LFR solution, a multi-stage optimization approach was proposed to breakdown the problem into several stages with more reasonable sizes. This optimization approach enabled finding various viable core solutions with different cost tradeoffs that were considered by Westinghouse and justify selection of a smaller core with multi-batch 2-year cycle length.

Stauff, Nicolas E.↗

Designing Critical Experiments Using Gaussian Process Optimization

New nuclear applications may lack similarity between the application and existing ICSBEP benchmarks. Without accurate benchmark data, predictive simulations will have high uncertainty in the estimate of a parameter of interest (such as k eff ). The design of critical experiments tuned for specific applications of interest is one solution to reducing uncertainty in the necessarily nuclear data. We propose an optimization technique to design critical experiments that match the cross-section sensitivities of an application model while minimizing the number of simulation runs in the optimization. The optimization of a critical experiment is slow because the potential design space covers many qualitative variables (types of material and geometries) and corresponding quantitative variables (e.g., material dimensions) and the evaluation of any specific design requires running an expensive code like MCNP1 and Whisper. The optimization of expensive black-box computer codes with quantitative variables has been extensively explored in the literature of design of computer experiments. We propose a modified version of standard Gaussian process (GP) optimization that optimizes over multiple discrete configurations of qualitative variables in parallel which reduces the computational cost of the entire optimization. The goal of this work is to minimize the number of MCNP evaluations while still exploring many different design configurations in parallel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗