Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Multiple target tracking and target attitude determination with a scanning laser radar

A scanning laser radar that can acquire and track single or multiple targets has recently been developed. Scan patterns have been designed for acquisition and tracking of one or more targets using a narrow laser beam. A synchronously scanned transmitter-receiver is used to acquire and track targets anywhere in a 376 x 376 element raster covering a 30 x 30 deg field. All scan patterns are electronically programmed, and the system automatically acquires and tracks the target or targets without the aid of an operator. The maximum tracking rate is 1.0 deg/sec (10.0 deg/sec) when used with a 1 kHz (10 kHz) scan rate. The estimated free space range against passive cooperative targets (corner cube reflectors) is 30 nautical miles. The laser radar has an accuracy of 10 cm (range) and 0.05 deg (angle). The developmental system is relatively small (1.5 cu ft), lightweight (60 lbs) and low-power-consuming (60 W).

Flom, T.↗

Holography through optically active windows

By using two orthogonally polarized reference beams, holograms can be recorded through stressed windows and the reconstructed virtual image will show no stress pattern. As shown analytically, the stress-pattern-free hologram is recordable for any polarization state of the object illumination. Hence, the more efficient nondepolarizing diffuser can be used in performing holography through stressed windows if two reference beams are used. Results are presented for a pair of machined polysulfone windows intended for use in a holographic flow-visualization setup in a single-stage-compressor test rig.

Decker, A. J.↗

Collectivity at N=40 in neutron-rich {sup 64}Cr

{sup 9}Be-induced inelastic scattering of {sup 62,64,66}Fe and {sup 60,62,64}Cr was performed at intermediate beam energies. Excited states in {sup 64}Cr were measured for the first time. Energies and population patterns of excited states in these neutron-rich Fe and Cr nuclei are compared and interpreted in the framework of large-scale shell-model calculations in different model spaces. Evidence for increased collectivity and for distinct structural changes between the neighboring Fe and Cr isotopic chains near N=40 is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reversible writing of high-mobility and high-carrier-density doping patterns in two-dimensional van der Waals heterostructures

A key feature of two-dimensional materials is that the sign and concentration of their carriers can be externally controlled with techniques such as electrostatic gating. However, conventional electrostatic gating has limitations, including a maximum carrier density set by the dielectric breakdown, and ionic liquid gating and direct chemical doping also suffer from drawbacks. In this work, we show that an electron-beam-induced doping technique can be used to reversibly write high-resolution doping patterns in hexagonal boron nitride-encapsulated graphene and molybdenum disulfide (MoS 2 ) van der Waals heterostructures. The doped MoS 2 device exhibits an order of magnitude decrease of subthreshold swing compared with the device before doping, whereas the doped graphene devices demonstrate a previously inaccessible regime of high carrier concentration and high mobility, even at room temperature. We also show that the approach can be used to write high-quality p–n junctions and nanoscale doping patterns, illustrating that the technique can create nanoscale circuitry in van der Waals heterostructures.

36 MATERIALS SCIENCE↗

Synchrotron X-ray studies of model SOFC cathodes, part I: Thin film cathodes

In this work, we present synchrotron x-ray investigations of thin film La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF) model cathodes for solid oxide fuel cells, grown on electrolyte substrates by pulse laser deposition, in situ during half-cell operations. We observed dynamic segregations of cations, such as Sr and Co, on the surfaces of the film cathodes. The effects of temperature, applied potentials, and capping layers on the segregations were investigated using a surfacesensitive technique of total external reflection x-ray fluorescence. We also studied patterned thin film LSCF cathodes using high-resolution micro-beam diffraction measurements. We find chemical expansion decreases for narrow stripes. This suggests the expansion is dominated by the bulk pathway reactions. Lastly, the chemical expansion vs. the distance from the electrode contact was measured at three temperatures and an oxygen vacancy activation energy was estimated to be ~1.4 eV.

36 MATERIALS SCIENCE↗

Regular surface grating on doped polymer induced by laser scanning

Thin polymer film doped with optical chromophore porphyrin are shown to respond to irradiation with laser light ({lambda}=405 nm). By simultaneous scanning with laser beam and continual mechanical movement of the polymer film regular grating pattern is formed on the polymer surface. Parameters of the grating vary in wide range as a function of the movement velocity and the laser intensity. Submicron, periodically structures can be prepared using the proposed technique.

36 MATERIALS SCIENCE↗

Strength and elasticity of niobium under high pressure

High purity polycrystalline niobium contained in boron-epoxy gasket was compressed in a diamond anvil cell (DAC). The pressure was increased in steps of {approx}3 GPa and the diffraction patterns recorded at each pressure with the incident x-ray beam perpendicular to the load axis of the DAC (radial diffraction). The maximum pressure reached was 37.6 GPa. The compressive strength (differential stress) derived from the radial diffraction data is 0.44(1) GPa at 2.1 GPa and shows a shallow maximum at {approx}5 GPa, and then decreases to 0.35(5) at 12 GPa. At higher pressures, strength increases nearly linearly and the extrapolated value at 40 GPa is 0.94(6) GPa. At any pressure, the single-crystal elastic moduli derived from the diffraction data can be made to match well those obtained from the extrapolation of the elasticity data at ambient pressure by adjusting the weight parameter {alpha} that appears in the lattice strain theory. The parameter {alpha} is found to decrease from 2.00(8) at 2.1 GPa to 1.35(4) at 37.6 GPa.

36 MATERIALS SCIENCE↗

Fundamental understanding of chemical processes in extreme ultraviolet resist materials

New photoresists are needed to advance extreme ultraviolet (EUV) lithography. The tailored design of efficient photoresists is enabled by a fundamental understanding of EUV induced chemistry. Processes that occur in the resist film after absorption of an EUV photon are discussed, and a new approach to study these processes on a fundamental level is described. The processes of photoabsorption, electron emission, and molecular fragmentation were studied experimentally in the gas-phase on analogs of the monomer units employed in chemically amplified EUV resists. To demonstrate the dependence of the EUV absorption cross section on selective light harvesting substituents, halogenated methylphenols were characterized employing the following techniques. Photoelectron spectroscopy was utilized to investigate kinetic energies and yield of electrons emitted by a molecule. The emission of Auger electrons was detected following photoionization in the case of iodo-methylphenol. Mass-spectrometry was used to deduce the molecular fragmentation pathways following electron emission and atomic relaxation. To gain insight on the interaction of emitted electrons with neutral molecules in a condensed film, the fragmentation pattern of neutral gas-phase molecules, interacting with an electron beam, was studied and observed to be similar to EUV photon fragmentation. Below the ionization threshold, electrons were confirmed to dissociate iodo-methylphenol by resonant electron attachment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Serial snapshot crystallography for materials science with SwissFEL

New opportunities for studying (sub)microcrystalline materials with small unit cells, both organic and inorganic, will open up when the X-ray free electron laser (XFEL) presently being constructed in Switzerland (SwissFEL) comes online in 2017. Our synchrotron-based experiments mimicking the 4%-energy-bandpass mode of the SwissFEL beam show that it will be possible to record a diffraction pattern of up to 10 randomly oriented crystals in a single snapshot, to index the resulting reflections, and to extract their intensities reliably. The crystals are destroyed with each XFEL pulse, but by combining snapshots from several sets of crystals, a complete set of data can be assembled, and crystal structures of materials that are difficult to analyze otherwise will become accessible. Even with a single shot, at least a partial analysis of the crystal structure will be possible, and with 10–50 femtosecond pulses, this offers tantalizing possibilities for time-resolved studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Protein crystal structure from non-oriented, single-axis sparse X-ray data

X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that are kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using the EMC algorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using the EMC algorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of the EMC algorithm even in cases where the data are sparse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial far-field otr images generated by 120-GeV protons at FNAL.

We have successfully imaged for the first time the angular distribution patterns of optical transition radiation (OTR) generated by 120-GeV proton beams passing through an Al metal plane. These experiments were performed at Fermilab (FNAL) with the same chamber, foil, and camera design as with the near-field experiments previously reported. In this case the lens-to-CID-chip separation was remotely adjusted to provide the focus-at- infinity, or far-field optical imaging. Data have been obtained in transport lines both before the antiproton production target and before the NuMI target with particle intensities of about 5 to 22 times 10{sup 12}. A two-foil interferometer calculation was also performed. Single-foil experimental and modeling results will be presented.

43 PARTICLE ACCELERATORS↗

WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations. Funding Support: this work is supported by funding the National Sciences and Engineering Research Council of Canada, and a Mitacs-accelerate fellowship. Conflict of Interest: Dr. Lindsay and Dr. Jaffray are listed as inventors of the small animal microirradiator described herein. This system has been licensed for commercial development.

60 APPLIED LIFE SCIENCES↗

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

Holographic testing with a double reference beam

Image of unstressed object is taken with reflected beam and one reference beam. Object is then stressed and second (double) exposure is made. Developed film plate provides double exposure hologram that can be projected by simultaneous illumination with both reference beams. Appearance of multiple images may be eliminated while manipulating fringe patterns.

Stuckenberg, F. H.↗

Surface flashover arc orientation on Mylar film

A study of the arc discharge patterns and resultant damage patterns on thin Mylar films exposed to a 20 keV electron beam is described. In particular, it is established that there is a broad directional correlation among the directions associated with visible linear arcs, damage tracks, the 'slow' optical direction and the longitudinal marks left on the films surface as a result of chemical etching. Transverse etch marks also appear to be associated with secondary groups of damage track directions. The 'fast' optical direction is associated with the absence of visible arcs or arc damage.

Gossland, M.↗

Analysis and testing of a new method for drop size measurement using laser scatter interferometry

Research was conducted on a laser light scatter detection method for measuring the size and velocity of spherical particles. The method is based upon the measurement of the interference fringe pattern produced by spheres passing through the intersection of two laser beams. A theoretical analysis of the method was carried out using the geometrical optics theory. Experimental verification of the theory was obtained by using monodisperse droplet streams. Several optical configurations were tested to identify all of the parametric effects upon the size measurements. Both off-axis forward and backscatter light detection were utilized. Simulated spray environments and fuel spray nozzles were used in the evaluation of the method. The measurements of the monodisperse drops showed complete agreement with the theoretical predictions. The method was demonstrated to be independent of the beam intensity and extinction resulting from the surrounding drops. Signal processing concepts were considered and a method was selected for development.

Bachalo, W. D.↗

The steady-state antenna patterns of adaptive arrays

A decomposition of the adapted pattern generated by an adaptive array operating in an environment with one narrowband signal, K-1 narrowband jammers, and programmed to produce the maximum SNR is presented. The antenna voltage pattern is demonstrated to be a linear combination of K (or less) basis patterns, each from a sole source, and the kth basis pattern becomes the desired signal realized by the array. Isotropic array patterns result in retrodirective basis patterns, and the decomposition can be configured to obtain the retrodirective beams for all K.

Zohar, S.↗