Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose equivalent in radiotherapy environments simplifying the practical procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-R-12: Prediction of TrueBeam Hardware Issues Using Trajectory Log Analysis

Purpose: To predict potential failures of hardware within the Varian TrueBeam linear accelerator in order to proactively replace parts and decrease machine downtime. Methods: Machine downtime is a problem for all radiation oncology departments and vendors. Most often it is the result of unexpected equipment failure, and increased due to lack of in-house clinical engineering support. Preventative maintenance attempts to assuage downtime, but often is ineffective at preemptively preventing many failure modes such as MLC motor failures, the need to tighten a gantry chain, or the replacement of a jaw motor, among other things. To attempt to alleviate downtime, software was developed in house that determines the maximum value of each axis enumerated in the Truebeam trajectory log files. After patient treatments, this data is stored in a SQL database. Microsoft Power BI is used to plot the average maximum error of each day of each machine as a function of time. The results are then correlated with actual faults that occurred at the machine with the help of Varian service engineers. Results: Over the course of six months, 76,312 trajectory logs have been written into the database and plotted in Power BI. Throughout the course of analysis MLC motors have been replaced on three machines due to the early warning of the trajectory log analysis. The service engineers have also been alerted to possible gantry issues on one occasion due to the aforementioned analysis. Conclusion: Analyzing the trajectory log data is a viable and effective early warning system for potential failures of the TrueBeam linear accelerator. With further analysis and tightening of the tolerance values used to determine a possible imminent failure, it should be possible to pinpoint future issues more thoroughly and for more axes of motion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deoxyinosine and 7-Deaza-2-Deoxyguanosine as Carriers of Genetic Information in the DNA of Campylobacter Viruses

Several reports have demonstrated that Campylobacter bacteriophage DNA is refractory to manipulation, suggesting that these phages encode modified DNA. The characterized Campylobacter jejuni phages fall into two phylogenetic groups within the Myoviridae: the genera Firehammervirus and Fletchervirus. Analysis of genomic nucleosides from several of these phages by high-pressure liquid chromatography-mass spectrometry confirmed that 100% of the 2'-deoxyguanosine (dG) residues are replaced by modified bases. Fletcherviruses replace dG with 2'-deoxyinosine, while the firehammerviruses replace dG with 2'-deoxy-7-amido-7-deazaguanosine (dADG), noncanonical nucleotides previously described, but a 100% base substitution has never been observed to have been made in a virus. We analyzed the genome sequences of all available phages representing both groups to elucidate the biosynthetic pathway of these noncanonical bases. Putative ADG biosynthetic genes are encoded by the Firehammervirus phages and functionally complement mutants in the Escherichia coli queuosine pathway, of which ADG is an intermediate. To investigate the mechanism of DNA modification, we isolated nucleotide pools and identified dITP after phage infection, suggesting that this modification is made before nucleotides are incorporated into the phage genome. However, we were unable to observe any form of dADG phosphate, implying a novel mechanism of ADG incorporation into an existing DNA strand. Our results imply that Fletchervirus and Firehammervirus phages have evolved distinct mechanisms to express dG-free DNA.

deazaguanosine↗

Histidine 375 Modulates CD4 Binding in HIV-1 CRF01_AE Envelope Glycoproteins

The envelope glycoproteins (Envs) from human immunodeficiency virus type 1 (HIV-1) mediate viral entry. The binding of the HIV-1 gp120 glycoprotein to CD4 triggers conformational changes in gp120 that allow high-affinity binding to its coreceptors. In contrast to all other Envs from the same phylogenetic group, M, which possess a serine (S) at position 375, those from CRF01_AE strains possess a histidine (H) at this location. This residue is part of the Phe43 cavity, where residue 43 of CD4 (a phenylalanine) engages with gp120. Here we evaluated the functional consequences of replacing this residue in two CRF01_AE Envs (CM244 and 92TH023) by a serine. We observed that reversion of amino acid 375 to a serine (H375S) resulted in a loss of functionality of both CRF01_AE Envs as measured by a dramatic loss in infectivity and ability to mediate cell-to-cell fusion. While no effects on processing or trimer stability of these variants were observed, decreased functionality could be linked to a major defect in CD4 binding induced by the replacement of H375 by a serine. Importantly, mutations of residues 61 (layer 1), 105 and 108 (layer 2), and 474 to 476 (layer 3) of the CRF01_AE gp120 inner domain layers to the consensus residues present in group M restored CD4 binding and wild-type levels of infectivity and cell-to-cell fusion. These results suggest a functional coevolution between the Phe43 cavity and the gp120 inner domain layers. Altogether, our observations describe the functional importance of amino acid 375H in CRF01_AE envelopes. IMPORTANCE A highly conserved serine located at position 375 in group M is replaced by a histidine in CRF01_AE Envs. Here we show that H375 is required for efficient CRF01_AE Env binding to CD4. Furthermore, this work suggests that specific residues of the gp120 inner domain layers have coevolved with H375 in order to maintain its ability to mediate viral entry.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular Architecture of Early Dissemination and Massive Second Wave of the SARS-CoV-2 Virus in a Major Metropolitan Area

We sequenced the genomes of 5,085 severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) strains causing two coronavirus disease 2019 (COVID-19) disease waves in metropolitan Houston, TX, an ethnically diverse region with 7 million residents. The genomes were from viruses recovered in the earliest recognized phase of the pandemic in Houston and from viruses recovered in an ongoing massive second wave of infections. The virus was originally introduced into Houston many times independently. Virtually all strains in the second wave have a Gly614 amino acid replacement in the spike protein, a polymorphism that has been linked to increased transmission and infectivity. Patients infected with the Gly614 variant strains had significantly higher virus loads in the nasopharynx on initial diagnosis. We found little evidence of a significant relationship between virus genotype and altered virulence, stressing the linkage between disease severity, underlying medical conditions, and host genetics. Some regions of the spike protein—the primary target of global vaccine efforts—are replete with amino acid replacements, perhaps indicating the action of selection. We exploited the genomic data to generate defined single amino acid replacements in the receptor binding domain of spike protein that, importantly, produced decreased recognition by the neutralizing monoclonal antibody CR3022. Our report represents the first analysis of the molecular architecture of SARS-CoV-2 in two infection waves in a major metropolitan region. The findings will help us to understand the origin, composition, and trajectory of future infection waves and the potential effect of the host immune response and therapeutic maneuvers on SARS-CoV-2 evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Structural mechanism of the formation of mineral Na-tveitite-a new type of phase with a fluorite-derivative structure-in the NaF-CaF{sub 2}-(Y,Ln)F{sub 3} natural system

Relationships between the chemical compositions and structures of the mineral tveitite from the southern Norway pegmatites (with the idealized formula Ca{sub 14}Y{sub 5}F{sub 43}) and Na-tveitite from the Rov mountain (Keivy, Kola Peninsula) Na{sub 2.5}Ca{sub 10}Ln{sub 1.5}Y{sub 5}F{sub 42} are considered. According to the structural mechanism of its formation, Na-tveitite is a nanocomposite crystal based on the crystalline matrix Ca{sub 14}Y{sub 5}F{sub 43} with the ordered arrangement of {l_brace}Ca{sub 8}[CaY{sub 5}]F{sub 69}{r_brace} clusters which contain anionic {l_brace}F{sub 13}{r_brace} cuboctahedra with F{sup 1-} at the center. When Na-tveitite is formed, 29% of these clusters are statistically replaced by Na-'Y' clusters {l_brace}[Na{sub 0.5}(Y,Ln){sub 0.5}]{sub 14}F{sub 64}{r_brace} with {l_brace}F{sub 8}{r_brace} cubes at the center (analogs of matrix fluorite groups {l_brace}Ca{sub 14}F{sub 64}{r_brace}). This replacement gives rise to composition-imperfect (Na, Ca, 'Y') cationic positions and occupancy-deficient F positions, which correspond to {l_brace}F{sub 13}{r_brace} cuboctahedra and the {l_brace}F{sub 8}{r_brace} cubes that replace them. The difference between Na-tveitite and fluorite phases M{sub 1-x}R{sub x}F{sub 2+x} is as follows: its matrix is the structure of the ordered phase (tveitite) into which Na-containing rare earth fragments of fluorite-type structure are incorporated instead of ordered-phase structural blocks (clusters).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Lithium Battery Cathodes Using Dispersed Carbon Fibers as the Current Collector

To fabricate LiFePO4 battery cathodes, highly conductive carbon fibers of 10-20 m in diameter have been used to replace a conventional aluminum (Al) foil current collector. This disperses the current collector throughout the cathode sheet and increases the contact area with the LiFePO4 (LFP) particles. In addition, the usual organic binder plus carbon-black can be replaced by a high temperature binder of <5 weight % carbonized petroleum pitch (P-pitch). Together these replacements increase the specific energy density and energy per unit area of the electrode. Details of the coating procedure, characterization and approach for maximizing the energy density are discussed. In a side-by-side comparison with conventional cathodes sheets of LFP on Al foil, the carbon fiber composite cathodes have a longer cycle life, higher thermal stability, and high capacity utilization with little sacrifice of the rate performance.

Carbon fiber↗

Evolution of the SLATE linear algebra library

SLATE (Software for Linear Algebra Targeting Exascale) is a distributed, dense linear algebra library targeting both CPU-only and GPU-accelerated systems, developed over the course of the Exascale Computing Project (ECP). While it began with several documents setting out its initial design, significant design changes occurred throughout its development. In some cases, these were anticipated: an early version used a simple consistency flag that was later replaced with a full-featured consistency protocol. In other cases, performance limitations and software and hardware changes prompted a redesign. Sequential communication tasks were parallelized; host-to-host MPI calls were replaced with GPU device-to-device MPI calls; more advanced algorithms such as Communication Avoiding LU and the Random Butterfly Transform (RBT) were introduced. Early choices that turned out to be cumbersome, error prone, or inflexible have been replaced with simpler, more intuitive, or more flexible designs. Applications have been a driving force, prompting a lighter weight queue class, nonuniform tile sizes, and more flexible MPI process grids. Of paramount importance has been building a portable library that works across several different GPU architectures – AMD, Intel, and NVIDIA – while keeping a clean and maintainable codebase. Here we explore the evolving design choices and their effects, both in terms of performance and software sustainability.

Gates, Mark↗

Continuous scanning mode for ptychography

We outline how ptychographic imaging can be performed without the need for discrete scan positions. Through an idealized experiment, we demonstrate how a discrete-position scan regime can be replaced with a continuously scanned one with suitable modification of the reconstruction scheme based on coherent modes. The impact of this is that acquisition times can be reduced, significantly aiding ptychographic imaging with x rays, electrons, or visible light.

Clark, Jesse N.↗

The Insertion Green Monster (iGM) Method for Expression of Multiple Exogenous Genes in Yeast

Being a simple eukaryotic organism, Saccharomyces cerevisiae provides numerous advantages for expression and functional characterization of proteins from higher eukaryotes, including humans. However, studies of complex exogenous pathways using yeast as a host have been hampered by the lack of tools to engineer strains expressing a large number of genetic components. In addition to inserting multiple genes, it is often desirable to knock out or replace multiple endogenous genes that might interfere with the processes studied. Here, we describe the “insertion Green Monster” (iGM) set of expression vectors that enable precise insertion of many heterologous genes into the yeast genome in a rapid and reproducible manner and permit simultaneous replacement of selected yeast genes. As a proof of principle, we have used the iGM method to replace components of the yeast pathway for methionine sulfoxide reduction with genes encoding the human selenoprotein biosynthesis machinery and generated a single yeast strain carrying 11 exogenous components of the selenoprotein biosynthetic pathway in precisely engineered loci.

Saccharomyces cerevisiae↗

Deciding Between an X-Ray and 137Cs Irradiator – It’s Not Just About Energy Spectra

Irradiators utilizing radioactive cesium-137 or cobalt-60 have been used for medical applications for many decades. This includes the irradiation of much of the nation’s blood supply, and radiation biology research. In 2005, the U.S. Nuclear Regulatory Commission was assigned to evaluate and prevent the misuse of radioactive materials with malicious intentions, with gamma-ray sources being high on the list. Licensees who possessed higher quantities of radioactive material of concern were required to set up increased security controls such as constant surveillance, controlled access, personnel background checks, and other security controls. As a result of introducing such regulations, and problems with disposing of high activity sources, many users of gamma-ray sources started to look into alternative technologies to replace their gamma-ray irradiators – the main alternative being an X-ray irradiator. To make an educated decision on whether a particular type of X-ray irradiator is equivalent to a particular type of cesium-137 irradiator for specific applications, one has to rely on relevant published comparison studies from other researchers, or perform the comparison studies on their own. This publication focuses on the authors’ technical performance comparison of two cesium-137 irradiator models and two X-ray irradiator models, for the purpose of determining whether the X-ray irradiator models could validly replace the cesium-137 irradiator models for certain applications. Utilizing 47 gram and 120 gram tissue-equivalent rodent dosimetry phantoms, our results indicate that, depending upon the user’s dose uncertainty budget and maximum size of specimens to be irradiated, the Model RS2000 160 kVp X-ray irradiator, Model XRAD-160 X-ray irradiator, or Model XRAD-320 X-ray irradiator, could successfully replace a cesium-137 irradiator. It is expected such equivalency could be extrapolated to other irradiated specimens of known sizes and density. Results also reveal that differences in inherent source geometry, field geometry and irradiation geometry can counter some of the influence due to differences in energy spectrum. It is hoped that this publication can be used as a guide for other similar studies, providing investigators guidance on important details that can make the difference between strong and weak comparison conclusions.

Cs-137 irradiator, X-ray Irradiator, self-containe↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 4a Raw Data

Calculated formation energy of (0001 ̅) c-plane GaN surfaces. The density-functional theory (DFT) calculations were performed with the generalized gradient approximation, using the plane-wave pseudopotential quantum-ESPRESSO package. Ultrasoft pseudopotentials were used to describe the interaction between valence electrons and ionic cores, where Ga 3d electrons were explicitly treated as valence electrons. The wave functions and electronic density were expanded in a plane-wave basis set truncated at a cutoff energy of 30 Ry and 240 Ry, respectively. The surface was modeled using a repeated slab geometry using a (2×2) unit cell with a thickness of seven GaN bilayers, where the Ga-terminated bottom side was passivated by pseudo-hydrogen with charge of 1.25e. In addition, the (1010) surface was modeled using 8 GaN atomic layers with a lateral dimension of 9.57 Å x 10.38 Å. A vacuum width of at least 15.0 Å was introduced between consecutive slabs, and a k-point mesh of 5x5x1 and 2x2x1 was used to sample the surface Brillouin zone for the polar and non-polar surfaces, respectively. Calculated formation energy of (0001 ̅) c-plane GaN surfaces with different oxygen configuration within the anion and cation-rich limits: ideal GaN surfaces of c-plane and m-plane; configurations with 100% replacement of nitrogen by oxygen on the surface c-plane and m-plane; 100% replacement of nitrogen by oxygen in the subsurface bilayer c-plane and m-plane; and configurations with 50% replacement of nitrogen of the surface and subsurface bilayers by oxygens c-plane and m-plane. In both cases, the ideal surface is chosen as the reference.

photocathode↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 4b Raw Data

Calculated formation energy of (1010 ̅) m-plane GaN surfaces. The density-functional theory (DFT) calculations were performed with the generalized gradient approximation, using the plane-wave pseudopotential quantum-ESPRESSO package. Ultrasoft pseudopotentials were used to describe the interaction between valence electrons and ionic cores, where Ga 3d electrons were explicitly treated as valence electrons. The wave functions and electronic density were expanded in a plane-wave basis set truncated at a cutoff energy of 30 Ry and 240 Ry, respectively. The surface was modeled using a repeated slab geometry using a (2×2) unit cell with a thickness of seven GaN bilayers, where the Ga-terminated bottom side was passivated by pseudo-hydrogen with charge of 1.25e. In addition, the (1010) surface was modeled using 8 GaN atomic layers with a lateral dimension of 9.57 Å x 10.38 Å. A vacuum width of at least 15.0 Å was introduced between consecutive slabs, and a k-point mesh of 5x5x1 and 2x2x1 was used to sample the surface Brillouin zone for the polar and non-polar surfaces, respectively. Calculated formation energy of (1010 ̅) m-plane GaN surfaces with different oxygen configuration within the anion and cation-rich limits: ideal GaN surfaces of c-plane and m-plane; configurations with 100% replacement of nitrogen by oxygen on the surface c-plane and m-plane; 100% replacement of nitrogen by oxygen in the subsurface bilayer c-plane and m-plane; and configurations with 50% replacement of nitrogen of the surface and subsurface bilayers by oxygens c-plane and m-plane. In both cases, the ideal surface is chosen as the reference.

photocathode↗

New Insertion Device Control System for the APS Upgrade

New Hybrid Permanent Magnet Undulators (HPMUs) have been designed and manufactured using servo motors for precise and reliable gap motion control for the Advanced Photon Source Upgrade (APS-U) project. Meanwhile, existing HPMUs equipped with legacy stepper motors are systematically replaced with servo motors. In parallel with mechanical modifications of the undulators, a comprehensive upgrade has been implemented for the control of the devices. This upgrade includes integration of standardized industrial components for replacement of motor controllers and motor drives using the Kollmorgen Programmable Controller Multi-axis Master (PCMM) controllers and the AKD2G series servo drives. Soft Input Output Controllers (IOCs) are developed and deployed to replace the legacy VME-based IOCs for both single-period undulators and Revolver undulators. In this paper, we will present the architecture of the new insertion device control system, including control mechanisms, interlock protocols, and tools for diagnostics and troubleshooting.

Li, W.↗

Oxygen Isotope Microanalysis By Secondary Ion Mass Spectrometry Suggests Continuous 300-million-year History of Calcite Cementation and Dolomitization in the Devonian Bakken Formation

Calcite cementation and dolomitization are key diagenetic processes in many sedimentary systems. Unravelling detailed histories and timescales of cementation and replacement is, however, often compromised by the limited spatial resolution of many analytical techniques; in some cases multiple grains are co-analyzed so that diagenetic histories are blurred and reaction periods are difficult to establish. In this study we have used 10-micrometer-resolution, in situ secondary ion mass spectrometry to determine the oxygen isotope composition of 197 individual, 10–50-micrometer-size crystals of dolomite and calcite from six samples in a single core of Upper Devonian middle Bakken Member siltstones and sandstones, the major tight oil formation of the Williston basin, USA. This amount of data places important constraints on the range of temperatures and times that carbonate cementation and replacement occurred. Petrographic data show that microcrystalline calcite cement is an early phase, and combined with mineralogical data suggest that much of the dolomite replaces calcite. Over spatial scales of less than a centimeter, analyses of individual calcite crystals have a range of 5‰ for δ 18 O in the group of crystals, and for the group of individual dolomite crystals, 10‰. These sub-centimeter ranges are as great as those observed in previous studies of carbonate cements sampled over many meters and remind us that previous low-resolution studies may have inadvertently analyzed mixed phases. There is no relationship between dolomite texture and isotopic composition at this spatial scale; microscale backscattered electron imagery and scanning electron microscopy cathodoluminescence zoning is seen, but cannot be resolved with a 10-micrometer spot size. Assuming, since it is an early cement, that calcite precipitated from seawater (δ 18 O = –1.5‰), it formed at ca. 15–40°C, mainly at the lower temperatures. Present-day formation waters in Devonian rocks in this region have oxygen isotope compositions of 7–8‰ VSMOW. Using these values as a likely dolomitizing fluid, we suggest that dolomitization occurred continuously between 40 and 140°C over 150–200 million years, most likely in a fluid with a high Mg/Ca ratio resulting from gypsum formation in local evaporites. Finally, we suggest that this exceptionally low rate of dolomitization was controlled by the low rate of supply of Mg in a very sluggish flow regime; dolomitization is incomplete because of a limited supply of Mg.

58 GEOSCIENCES↗

Scaling Up: Kilolumen Solid-State Lighting Exceeding 100 LPW via Remote Phosphor

This thirty-month project was successful in attaining its ambitious objectives of demonstrating a radically novel 'remote-phosphor' LED light source that can out-perform conventional conformal coated phosphor LED sources. Numerous technical challenges were met with innovative techniques and optical configurations. This product development program for a new generation of solid-state light sources has attained unprecedented luminosity (over 1 kilo-lumen) and efficacy (based on the criterion lumens per 100mw radiant blue). LPI has successfully demonstrated its proprietary technology for optical synthesis of large uniform sources out of the light output of an array of separated LEDs. Numerous multiple blue LEDs illuminate single a phosphor patch. By separating the LEDs from the phosphor, the phosphor and LEDs operate cooler and with higher efficiency over a wide range of operating conditions (from startup to steady state). Other benefits of the system include: better source uniformity, more types of phosphor can be used (chemical interaction and high temperatures are no longer an issue), and the phosphor can be made up from a pre-manufactured sheet (thereby lowering cost and complexity of phosphor deposition). Several laboratory prototypes were built and operated at the expected high performance level. The project fully explored two types of remote phosphor system: transmissive and reflective. The first was found to be well suited for a replacement for A19 type incandescent bulbs, as it was able to replicate the beam pattern of a traditional filament bulb. The second type has the advantages that it is pre-collimate source that has an adjustable color temperature. The project was divided in two phases: Phase I explored a transmissive design and Phase II of the project developed reflective architectures. Additionally, in Phase II the design of a spherical emitting transmissive remote phosphor bulb was developed that is suitable for replacement of A19 and similar light bulbs. In Phase II several new reflective remote phosphor systems were developed and patents applied for. This research included the development of reflective systems in which the short-pass filter operated at a nominal incidence angle of 15{sup o}, a major advancement of this technology. Another goal of the project was to show that it is possible to align multiple optics to multiple LEDs (spaced apart for better thermal management) to within an accuracy in the z-direction of 10 microns or less. This goal was achieved. A further goal was to show it is possible to combine and homogenize the output from multiple LEDs without any flux loss or significant increase in etendue. This goal also was achieved. The following color-coded computer drawing of the Phase 2 reflective remote phosphor prototype gives an idea of the accuracy challenges encountered in such an assembly. The actual setup has less functional clarity due to the numerous items of auxiliary equipment involved. Not only did 10 degrees of freedoms alignment have to be supplied to the LEDs and component prisms as well, but there were also micro-titrating glue dispensers and vacuum hoses. The project also utilized a recently introduced high-index glass, available in small customized prisms. This prototype also embodies a significant advance in thin-film design, by which an unprecedented 98% single-pass efficiency was attained over a 30 degree range of incidence angle (Patents Pending). Such high efficiency is especially important since it applies to the blue light going to the phosphor and then again to the phosphor's light, so that the 'system' efficiency associated with short-pass filter was 95.5%. Other losses have to be kept equally small, towards which a new type of ultra-clear injection-moldable acrylic was discovered and used to make ultra-transparent CPC optics. Several transmissive remote phosphor prototypes were manufactured that could replace screw-in type incandescent bulbs. The CRI of the white light from these prototypes varied from 55 to 93. The system efficiency achieved was between 27 to 29.5 lumens per 100 mw radiant blue. For blue LEDs providing 200mw blue for 1 watt electrical input, these prototypes produced 54 to 59 lumens per watt. The latest blue LEDs (from several manufacturers) are more than twice as efficient as this. So in this case the efficiency of the systems (exclusive of driver losses) would be minimally 108 to 118 lumens per watt. So the systems efficiency of the transmissive remote phosphor was proven to be equal to or greater than if the same LEDs use conformal coated phosphor; with the stated advantages of the remote phosphor system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVALUATION OF ARG-1 SAMPLES PREPARED BY CESIUM CARBONATE DISSOLUTION DURING THE ISOLOK SME ACCEPTABILITY TESTING

Evaluation of Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) recently completed the evaluation of one of these opportunities - the possibility of using an Isolok sampling valve as an alternative to the Hydragard valve for taking DWPF process samples at the Slurry Mix Evaporator (SME). The use of an Isolok for SME sampling has the potential to improve operability, reduce maintenance time, and decrease CPC cycle time. The SME acceptability testing for the Isolok was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 and was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNLRP-2011-00145. RW-0333P QA requirements applied to the task, and the results from the investigation were documented in SRNL-STI-2011-00693. Measurement of the chemical composition of study samples was a critical component of the SME acceptability testing of the Isolok. A sampling and analytical plan supported the investigation with the analytical plan directing that the study samples be prepared by a cesium carbonate (Cs{sub 2}CO{sub 3}) fusion dissolution method and analyzed by Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES). The use of the cesium carbonate preparation method for the Isolok testing provided an opportunity for an additional assessment of this dissolution method, which is being investigated as a potential replacement for the two methods (i.e., sodium peroxide fusion and mixed acid dissolution) that have been used at the DWPF for the analysis of SME samples. Earlier testing of the Cs{sub 2}CO{sub 3} method yielded promising results which led to a TTR from Savannah River Remediation, LLC (SRR) to SRNL for additional support and an associated TTQAP to direct the SRNL efforts. A technical report resulting from this work was issued that recommended that the mixed acid method be replaced by the Cs{sub 2}CO{sub 3} method for the measurement of magnesium (Mg), sodium (Na), and zirconium (Zr) with additional testing of the method by DWPF Laboratory being needed before further implementation of the Cs{sub 2}CO{sub 3} method at that laboratory. While the SME acceptability testing of the Isolok does not address any of the open issues remaining after the publication of the recommendation for the replacement of the mixed acid method by the Cs{sub 2}CO{sub 3} method (since those issues are to be addressed by the DWPF Laboratory), the Cs{sub 2}CO{sub 3} testing associated with the Isolok testing does provide additional insight into the performance of the method as conducted by SRNL. The performance is to be investigated by looking to the composition measurement data generated by the samples of a standard glass, the Analytical Reference Glass - 1 (ARG-1), that were prepared by the Cs{sub 2}CO{sub 3} method and included in the SME acceptability testing of the Isolok. The measurements of these samples were presented as part of the study results, but no statistical analysis of these measurements was conducted as part of those results. It is the purpose of this report to provide that analysis, which was supported using JMP Version 7.0.2.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗