Search NASA⌕ Search

SEARCH · Search NASA

Results for “sequential analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Data for The Effects of Sequential Hydrothermal-Mechanical Refining Pretreatment on Cellulose Structure Changes and Sugar Recoveries

The recalcitrance of lignocellulosic biomass necessitates an efficient pretreatment protocol for operating a successful cellulosic biorefinery. It is critical to improve cellulose accessibility for hydrolysis and fermentation by altering the plant cell wall’s physical structure and chemical composition. Sequential hydrothermal-mechanical refining pretreatment (HMR) allows efficient recovery of cellulosic sugars without utilizing any hazardous chemicals. HMR has been successfully applied to Liberty switchgrass, a bioenergy cultivar released by the USDA, and now it is being applied to oilcane, a recently developed transgenic sugarcane variety engineered to accumulate lipids in its vegetative tissues. Sugar yields of oilcane bagasse (OCB) and switchgrass (SG) treated with HMR are 96.4% and 75.4%, respectively. This study sought to correlate cellulosic sugar yields with structural changes within the cell wall caused by HMR on two distinct bioenergy crops. Simon’s staining technique for the specific surface area analysis showed that HMR increased the specific surface area of pretreated biomass residues by 80-112%. In addition, ATR-FTIR was performed to determine the effects of HMR on physical structures based on the total crystallinity index (TCI) and hydrogen bonding intensity (HBI). Irrespective of biomass type, HMR decreased the initial crystalline cellulose contents of untreated biomass residues by 3.5% and reduced TCI and HBI by 7-13%. The study found that sugar yields were negatively correlated to reducing values of hydrogen bonding intensity, crystalline cellulose content, and total crystallinity index.

Biomass Analytics↗

Design and test hardware for a solar array switching unit

This paper describes the control of a pulse width modulated (PWM) type sequential shunt switching unit (SSU) for spacecraft applications. It is found that the solar cell output capacitance has a significant impact on SSU design. Shorting of this cell capacitance by the PWM switch causes input current surges. These surges are minimized by the use of a series filter inductor. The system with a filter is analyzed for ripple and the control to output-voltage transfer function. Stable closed loop design considerations are discussed. The results are supported by modeling and measurements of loop gain and of closed-loop bus impedance on test hardware for NASA's 120 V Earth Observation System (EOS). The analysis and modeling are also applicable to NASA's 160 V Space Station power system.

Patil, A. R.↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

In Situ Analysis of Solvent and Additive Effects on Film Morphology Evolution in Spin-Cast Small-Molecule and Polymer Photovoltaic Materials

To elucidate the details of film morphology/order evolution during spin-coating, solvent and additive effects are systematically investigated for three representative organic solar cell (OSC) active layer materials using combined in situ grazing incidence wide angle x-ray scattering (GIWAXS) and optical reflectance. Two archetypical semiconducting donor (p-type) polymers, P3HT and PTB7, and semiconducting donor small-molecule, p-DTS(FBTTh 2 ) 2 are studied using three neat solvents (chloroform, chlorobenzene, 1,2-dichlorobenzene) and four processing additives (1-chloronaphthalene, diphenyl ether, 1,8-diiodooctane, and 1,6-diiodohexane). In situ GIWAXS identifies several trends: 1) for neat solvents, rapid crystallization occurs that risks kinetically locking the material into multiple crystal structures or crystalline orientations; and 2) for solvent + additive processed films, morphology evolution involves sequential transformations on timescales ranging from seconds to hours, with key divergences dependent on additive/semiconductor molecular interactions. When π-planes dominate the additive/semiconductor interactions, both polymers and small molecule films follow similar evolutions, completing in 1–5 min. When side chains dominate the additive/semiconductor interactions, polymer film maturation times are up to 9 h, while initial crystallization times <10 s are observed for small-molecule films. In conclusion, this study offers guiding information on OSC donor intermediate morphologies, evolution timescales, and divergent evolutions that can inform OSC manufacture.

25 ENERGY STORAGE↗

Using Tabulated Experimental Data to Drive an Orthotropic Elasto-Plastic Three-Dimensional Model for Impact Analysis

An orthotropic elasto-plastic-damage three-dimensional model with tabulated input has been developed to analyze the impact response of composite materials. The theory has been implemented as MAT 213 into a tailored version of LS-DYNA being developed under a joint effort of the FAA and NASA and has the following features: (a) the theory addresses any composite architecture that can be experimentally characterized as an orthotropic material and includes rate and temperature sensitivities, (b) the formulation is applicable for solid as well as shell element implementations and utilizes input data in a tabulated form directly from processed experimental data, (c) deformation and damage mechanics are both accounted for within the material model, (d) failure criteria are established that are functions of strain and damage parameters, and mesh size dependence is included, and (e) the theory can be efficiently implemented into a commercial code for both sequential and parallel executions. The salient features of the theory as implemented in LS-DYNA are illustrated using a widely used composite - the T800S/3900-2B[P2352W-19] BMS8-276 Rev-H-Unitape fiber/resin unidirectional composite. First, the experimental tests to characterize the deformation, damage and failure parameters in the material behavior are discussed. Second, the MAT213 input model and implementation details are presented with particular attention given to procedures that have been incorporated to ensure that the yield surfaces in the rate and temperature dependent plasticity model are convex. Finally, the paper concludes with a validation test designed to test the stability, accuracy and efficiency of the implemented model.

Polymer Matrix Composites↗

High Speed, Localized Multi-Point Strain Measurements on a Containment Vessel at 1.7 MHz Using Swept-Wavelength Laser-Interrogated Fiber Bragg Gratings

Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.

47 OTHER INSTRUMENTATION↗

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

Synoptic studies of chromospheric variability in F - K dwarfs with the IUE

Time-sequential series of IUE spectra for ten F, G and K dwarfs were obtained in 1980 and 1981 to study the rotational dependence of chromospheric flux in the ultraviolet. An interactive computational method using unbiased estimators was developed to measure emission line fluxes free of arbitrary judgement concerning the behavior of the underlying spectrum and shapes of the line profiles. Due to the limited number of observational samples per star, we have used special techniques to analyze the sparsely and anharmonically sampled emission line flux data. Two different autocorrelation measures were computed for each emission line as a function of temporal frequency. Examples and results of this analysis now in progress are given for several stars.

Hallam, K. L.↗

Computational Systems Biology

Computational systems biology is the term that we use to describe computational methods to identify, infer, model, and store relationships between the molecules, pathways, and cells (“systems”) involved in a living organism. Based on this definition, the field of computational systems biology has been in existence for some time. However, the recent confluence of high throughput methodology for biological data gathering, genome-scale sequencing and computational processing power has driven a reinvention and expansion of this field. The expansions include not only modeling of small metabolic{Ishii, 2004 #1129; Ekins, 2006 #1601; Lafaye, 2005 #1744} and signaling systems{Stevenson-Paulik, 2006 #1742; Lafaye, 2005 #1744} but also modeling of the relationships between biological components in very large systems, incluyding whole cells and organisms {Ideker, 2001 #1124; Pe'er, 2001 #1172; Pilpel, 2001 #393; Ideker, 2002 #327; Kelley, 2003 #1117; Shannon, 2003 #1116; Ideker, 2004 #1111}{Schadt, 2003 #475; Schadt, 2006 #1661}{McDermott, 2002 #878; McDermott, 2005 #1271}. Generally these models provide a general overview of one or more aspects of these systems and leave the determination of details to experimentalists focused on smaller subsystems. The promise of such approaches is that they will elucidate patterns, relationships and general features that are not evident from examining specific components or subsystems. These predictions are either interesting in and of themselves (for example, the identification of an evolutionary pattern), or are interesting and valuable to researchers working on a particular problem (for example highlight a previously unknown functional pathway). Two events have occurred to bring about the field computational systems biology to the forefront. One is the advent of high throughput methods that have generated large amounts of information about particular systems in the form of genetic studies, gene expression analyses (both protein and mRNA) and metabolomics. With such tools, research to consider systems as a whole are being conceived, planned and implemented experimentally on an ever more frequent and wider scale. The other is the growth of computational processing power and tools. Methods to analyze large data sets of this kind are often computationally demanding and, as is the case in other areas, the field has benefited from continuing improvements in computational hardware and methods. The field of computational biology is very much like a telescope with two sequential lenses: one lens represents the biological data and the other represents a computational and/or mathematical model of the data. Both lenses must be properly coordinated to yield an image that reflects biological reality. This means that the design parameters for both lenses must be designed in concert to create a system that yields a model of the organism that provides both predictive and mechanistic information. The chapters in this book describe the construction of subcomponents of such a system. Computational systems biology is a rapidly evolving field and no single group of investigators has yet developed a compete system that integrates both data generation and data analysis in such a way so as to allow full and accurate modeling of any single biological organism. However, the field is rapidly moving in that direction. The chapters in this book represent a snapshot of the current methods being developed and used in the area of computational systems biology. Each method or database described within represents one or more steps on the path to a complete description of a biological system. How these tools will evolve and ultimately be integrated is an area of intense research and interest. We hope that readers of this book will be motivated by the chapters within and become involved in this exciting area of research.

59 BASIC BIOLOGICAL SCIENCES↗

Sequential lateral solidification of silicon thin films on low-k dielectrics for low temperature integration

We present the excimer laser crystallization of amorphous silicon on a low dielectric constant (low-k) insulator for very large scale integration monolithic 3D integration and demonstrate that low dielectric constant materials are suitable substrates for 3D integration through laser crystallization of silicon thin films. We crystallized 100 nm amorphous silicon on top of SiO{sub 2} and SiCOH (low-k) dielectrics, at different material thicknesses (1 μm, 0.75 μm, and 0.5 μm). The amorphous silicon crystallization on low-k dielectric requires 35% less laser energy than on an SiO{sub 2} dielectric. This difference is related to the thermal conductivity of the two materials, in agreement with one dimensional simulations of the crystallization process. We analyzed the morphology of the material through defect-enhanced microscopy, Raman spectroscopy, and X-ray diffraction analysis. SEM micrographs show that polycrystalline silicon is characterized by micron-long grains with an average width of 543 nm for the SiO{sub 2} sample and 570 nm for the low-k samples. Comparison of the Raman spectra does not show any major difference in film quality for the two different dielectrics, and polycrystalline silicon peaks are closely placed around 517 cm{sup −1}. From X-ray diffraction analysis, the material crystallized on SiO{sub 2} shows a preferential (111) crystal orientation. In the SiCOH case, the 111 peak strength decreases dramatically and samples do not show preferential crystal orientation. A 1D finite element method simulation of the crystallization process on a back end of line structure shows that copper (Cu) damascene interconnects reach a temperature of 70 °C or lower with a 0.5 μm dielectric layer between the Cu and the molten Si layer, a favorable condition for monolithic 3D integration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fine-root mortality rates in a temperate forest: Estimates using radiocarbon data and numerical modeling

We used an inadvertent whole-ecosystem {sup 14}C label at a temperate forest in Oak Ridge, Tennessee, USA to develop a model (Radix1.0) of fine-root dynamics. Radix simulates two live-root pools, two dead-root pools, non-normally distributed root mortality turnover times, a stored carbon (C) pool, and seasonal growth and respiration patterns. We applied Radix to analyze measurements from two root size classes (< 0.5 and 0.5-2.0 mm diameter) and three soil-depth increments (O horizon, 0-15 cm and 30-60 cm). Predicted live-root turnover times were < 1 yr and 10 yr for short- and long-lived pools, respectively. Dead-root pools had decomposition turnover times of 2 yr and 10 yr. Realistic characterization of C flows through fine roots requires a model with two live fine-root populations, two dead fine-root pools, and root respiration. These are the first fine-root turnover time estimates that take into account respiration, storage, seasonal growth patterns, and non-normal turnover time distributions. The presence of a root population with decadal turnover times implies a lower amount of belowground net primary production used to grow fine-root tissue than is currently predicted by models with a single annual turnover pool.

54 ENVIRONMENTAL SCIENCES↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Poincare Software to Predict Arrythmias

The most distressing types of heart malfunction occur because of an abnormal rhythm of the heart. Cardiac arrythmias can be caused by abnormal rhythmicity of the pacemaker, electrolyte disturbances, blockage of the transmission of the electric impulse through the heart, and other abnormalities. There is strong evidence that space flight is associated with decreased cardiac electrical stability that may pose a life threatening risk to astronauts. For example, during the Skylab missions, a crewmember had a five beat run of ventricular tachycardia during lower body negative pressure. Also, analysis of nine 24-hour Holter monitor recordings obtained during long term spaceflight on Mir revealed one 14-beat run of ventricular tachycardia. A Mir cosmonaut was replaced in 1986 because of cardiac dysrhythmias. Most recently, in July of 1997, a Mir commander was unable to participate in the Spektr module repair due to complaints of an irregular heart rhythm. Despite these examples, possible mechanisms of arrhythmias and countermeasure strategies have barely been addressed. The Poincare method has been proposed as a technique that might potentially predict life-threatening arrhythmias before they occur. According to this method, each RR interval obtained from an EKG recording is plotted sequentially vs. the previous RR interval. Several studies using the method have demonstrated a strong correlation between the shape of the Poincare plot and ventricular arrhythmia. Our purpose was to develop an automated software program that detects the R peaks from an EKG recording while simultaneously displaying the Poincare plot and other related parameters.

Maaliki, Samer↗

An Acquisition Control for the Laser Interferometer Space Antenna

The Laser Interferometer Space Antenna (LISA) mission is a planned gravitational wave detector consisting of three spacecraft in heliocentric orbit. Laser interferometry is used to measure distance fluctuations between test masses aboard each spacecraft to the picometer level over a 5 million kilometer separation. Each spacecraft has two incoming and two outgoing laser beams for a total of six laser links. These links will have to be established sequentially at the start of the mission, and the spacecraft control systems must aim their lasers at each other with pointing motions less than 8 nanoradians per root Hertz in the frequency band 0.1-100 mHz. This paper presents a strategy for the laser acquisition process. The outgoing beam on one spacecraft is spoiled to provide a wide beam that encompasses the accuracy (noise and mounting bias) of the star tracker. The control system then takes advantage of an array of sensors with increasing sensitivity to quiet the receiving spacecraft and lock the laser. This process is carried out for each of the six links of LISA. A complete analysis and simulation of the acquisition process are presented.

Maghami, Peiman G.↗

Reliability Analysis of Power Grids Considering Component Failures of Variable Energy Resources

This paper proposes an improved model for the reliability assessment of power systems considering component failures of variable energy resources (VER). The inherent intermittency of VER such as solar photovoltaic (PV) and wind farms, along with their susceptibility to component failures, present significant challenges to reliable system operation. These issues, combined with power grid operation and network constraints, complicate the reliable operation of VER-integrated power systems. Here, to address these concerns, this paper introduces a reliability assessment framework that considers VER input variability, its impact on component availability, and their resulting impact on overall system reliability. Stochastic models based on discrete Markov processes are developed to incorporate variable irradiance, wind speeds, and their effects on PV and wind component failure rates. A next-event and state transition-based approach is then developed to integrate the stochastic models into a mixed-timing sequential Monte Carlo simulation framework for composite reliability assessment. Case studies on the RTS-GMLC system demonstrate the effectiveness of the proposed model in evaluating the reliability of VER-integrated systems.

Pandit, Dilip [Sandia National Laboratories (SNL-N↗

Synchrotron X-ray diffraction study of the Ba{sub 1−x}SrSnO{sub 3} solid solution

At room temperature the sequence of phases with increasing amounts of strontium in the stannate perovskite system Ba{sub 1−x}SrSnO{sub 3} has been established from high resolution synchrotron X-ray powder diffraction. The observed sequence orthorhombic (Pbnm), orthorhombic (Ibmm), tetragonal (I4/mcm), and cubic (Pm3-bar m) is a consequence of the sequential introduction of cooperative tilting of the corner sharing SnO{sub 6} octahedra. The cell volume changes smoothly across the series with no obvious discontinuities associated with the phase transitions. - Graphical abstract: Portions of the synchrotron X-ray diffraction profiles (λ=0.82453 Å) from selected Ba{sub 1−x}Sr{sub x}SnO{sub 3} samples together with the results of fitting by the Rietveld method. Highlights: ► Structures of the stannate perovskites Ba{sub 1−x}SrSnO{sub 3} refined from synchrotron XRD. ► The sequence Pm3-bar m→I4/mcm→Ibmm→Pbnm results from tilting of the octahedra. ► The tilting maintains optimal bonding of the cations seen from the BVS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fundamental analysis of the failure of polymer-based fiber reinforced composites

A mathematical model is described which will permit predictions of the strength of fiber reinforced composites containing known flaws to be made from the basic properties of their constituents. The approach was to embed a local heterogeneous region (LHR) surrounding the crack tip into an anisotropic elastic continuum. The model should (1) permit an explicit analysis of the micromechanical processes involved in the fracture process, and (2) remain simple enough to be useful in practical computations. Computations for arbitrary flaw size and orientation under arbitrary applied load combinations were performed from unidirectional composites with linear elastic-brittle constituent behavior. The mechanical properties were nominally those of graphite epoxy. With the rupture properties arbitrarily varied to test the capability of the model to reflect real fracture modes in fiber composites, it was shown that fiber breakage, matrix crazing, crack bridging, matrix-fiber debonding, and axial splitting can all occur during a period of (gradually) increasing load prior to catastrophic fracture. The computations reveal qualitatively the sequential nature of the stable crack process that precedes fracture.

Kanninen, M. F.↗

Use of Inverse Reinforcement Learning for Identity Prediction

We adopt Markov Decision Processes (MDP) to model sequential decision problems, which have the characteristic that the current decision made by a human decision maker has an uncertain impact on future opportunity. We hypothesize that the individuality of decision makers can be modeled as differences in the reward function under a common MDP model. A machine learning technique, Inverse Reinforcement Learning (IRL), was used to learn an individual's reward function based on limited observation of his or her decision choices. This work serves as an initial investigation for using IRL to analyze decision making, conducted through a human experiment in a cyber shopping environment. Specifically, the ability to determine the demographic identity of users is conducted through prediction analysis and supervised learning. The results show that IRL can be used to correctly identify participants, at a rate of 68% for gender and 66% for one of three college major categories.

Hayes, Roy↗