Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

High quantum efficiency photocathode simulation for the investigation of novel structured designs

A computer model in CST Studio Suite has been developed to evaluate several novel geometrically enhanced photocathode designs. This work was aimed at identifying a structure that would increase the total electron yield by a factor of two or greater in the 1–30 keV range. The modeling software was used to simulate the electric field and generate particle tracking for several potential structures. The final photocathode structure has been tailored to meet a set of detector performance requirements, namely, a spatial resolution of <40 μm and a temporal spread of 1–10 ps. We present the details of the geometrically enhanced photocathode model and resulting static field and electron emission characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE RADIO-2 mm SPECTRAL INDEX OF THE CRAB NEBULA MEASURED WITH GISMO

We present results of 2 mm observations of the Crab Nebula, obtained using the Goddard-IRAM Superconducting 2 Millimeter Observer (GISMO) bolometer camera on the IRAM 30 m telescope. Additional 3.3 mm observations with the MUSTANG bolometer array on the Green Bank Telescope are also presented. The integrated 2 mm flux density of the Crab Nebula provides no evidence for the emergence of a second synchrotron component that has been proposed. It is consistent with the radio power-law spectrum, extrapolated up to a break frequency of log ({nu}{sub b}[GHz]) = 2.84 {+-} 0.29 or {nu}{sub b} = 695{sup +651}{sub -336} GHz. The Crab Nebula is well resolved by the {approx}16.''7 beam (FWHM) of GISMO. Comparison to radio data at comparable spatial resolution enables us to confirm significant spatial variation of the spectral index between 21 cm and 2 mm. The main effect is a spectral flattening in the inner region of the Crab Nebula, correlated with the toroidal structure at the center of the nebula that is prominent in the near-IR through X-ray regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the Spatial Profiles of Electron and Hole Concentration, Radiative and Non-Radiative Recombination Rate Near a Dislocation Defect by Combining Raman and Photoluminescence Imaging

For commonly utilized photoluminescence (PL) imaging, the spatial resolution is dictated by the carrier diffusion length rather than by that dictated by the optical system, such as diffraction limit. Here, we show that Raman imaging of the LO phonon-plasmon (LOPP) coupled mode can be used to recover the intrinsic spatial resolution of the optical system, as demonstrated by Raman imaging of defects in GaAs, achieving a 10-fold improvement in resolution. Furthermore, by combining Raman and PL imaging, we can independently determine the spatial profiles of the electron and hole density, radiative and non-radiative recombination rate near a dislocation defect, which has not been possible using other techniques.

14 SOLAR ENERGY↗

The Hourly GHI, DHI and DNI: Intercomparison of the CERES-Based Data and the NSRDB Data through Comparison with the Ground-Based BSRN Data

The NASA Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg(Ed4.1) provides hourly global horizontal irradiance (GHI), diffuse horizontal irradiance (DHI) and direct horizontal irradiance (DirHI) at 1-degree latitude by 1-degree longitude resolution, and the time span is from March 2000 to near present. While the GHI agrees well with the ground-based Baseline Surface Radiation Network (BSRN) data, the DHI and DirHI are, respectively, positively and negatively biased against the BSRN data, and so is the direct normal irradiance (DNI) derived simply by dividing the DirHI by the cosine of the hourly solar zenith angle (SZA). We found that the biases tend to be well-defined functions of cos(SZA) and the cloud fraction (CLFR). We thus performed a bias-correction on the hourly DHI and DNI in the latitude-cos(SZA)-CLFR phase space, and therefrom, we derived the hourly global tilted irradiance (GTI) at a number of tilt angles using the isotropic diffuse irradiance model, and the results agree well with the GTI derived from the original BSRN near-instantaneous records. Meanwhile, the National Renewable Energy Laboratory (NREL) has produced the National Solar Radiation Database (NSRDB) with finer spatiotemporal resolution using its Physical Solar Model (PSM) and surface-based measured data, model results and satellite-based data as inputs. Now the NSRDB data covers not only the United States and its neighboring regions, but Europe, Africa, Asia and Oceania. The available temporal resolutions are 5, 10, 15, 30 and 60 minutes and the spatial resolutions are 2, 4 and 10 km, depending on the selected region. In this presentation, we compare both the CERES-based and NSRDB GHI, DHI and DNI with their BSRN counterparts and show how finer spatial resolution may give us an advantage in data accuracy and usability.

Taiping Zhang↗

High resolution DEPFET active pixel sensors for the Belle II experiment

The new Belle II experiment at the SuperKEKB collider at KEK was launched in 2009 as a general upgrade of the previous successful Belle experiment. Important improvements in the Belle II detector are additional two pixel layers forming the innermost part of the vertex detector. This paper gives a short overview of the expected impact of the two inner pixel layers on the performance of Belle II based on simulations and current experimental knowledge of the DEPFET pixel detectors. The focus is on the expected performance of the thinned DEPFET pixel sensors in Belle II in terms of spatial resolution. The measurements and simulations of the current generation of DEPFET sensors in beam tests indicate that the design resolution requirements can be met. The dependence of the spatial resolution on the deposited energy was observed in beam tests and we simulated the effect for the Belle II detector type to estimate its magnitude. A short description of the readout and data acquisition chain of the Belle II pixel vertex detector is given. (authors)

43 PARTICLE ACCELERATORS↗

Poloidal beam emission spectroscopy system for the measurement of density fluctuations in Large Helical Device

A system of beam emission spectroscopy (BES) for density fluctuation measurements having the sightlines passing through the plasma in the poloidal direction was developed in the Large Helical Device (LHD). Even though the angle between the beam and the sightline is slightly larger than a right angle, Doppler-shifted beam emission can be distinguished from background emission because of the high energy (120-170 keV) of the neutral beam for heating with negative ion sources. Spatial resolution is about 0.1-0.2 in the normalized radius. Compared with the prototype BES system with toroidal sightlines, the BES system with poloidal sightlines showed improved spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Super-Resolution Algorithm for Enhancement of FLASH LIDAR data

A novel method for enhancement of the spatial resolution of 3-dimensional Flash Lidar images is being proposed for generation of elevation maps of terrain from a moving platform. NASA recognizes the Flash LIDAR technology as an important tool for enabling safe and precision landing in future unmanned and crewed lunar and planetary missions. The ability of the Flash LIDAR to generate 3-dimensional maps of the landing site area during the final stages of the descent phase for detection of hazardous terrain features such as craters, rocks, and steep slopes is under study in the frame of the Autonomous Landing and Hazard Avoidance (ALHAT) project. Since single frames of existing FLASH LIDAR systems are not sufficient to build a map of entire landing site with acceptable spatial resolution and precision, a super-resolution approach utilizing multiple frames has been developed to overcome the instrument s limitations. Performance of the super-resolution algorithm has been analyzed through a series of simulation runs obtained from a high fidelity Flash LIDAR model and a high resolution synthetic lunar elevation map. For each simulation run, a sequence of FLASH LIDAR frames are recorded and processed as the spacecraft descends toward the landing site. Simulations runs having different trajectory profiles and varying LIDAR look angles of the terrain are also analyzed. The results show that adequate levels of accuracy and precision are achieved for detecting hazardous terrain features and identifying safe areas of the landing site.

Bulyshev, Alexander↗

Images of the laser entrance hole from the static x-ray imager at NIF

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 {mu}m spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗

Cathode Strip Chambers in ATLAS: Installation, Commissioning and in situ Performance

The Muon Spectrometer of the ATLAS detector at the LHC is designed to provide high quality stand-alone muon identification, momentum measurement and trigger capabilities with high pseudorapidity coverage. Precision tracking at the inner-most station in the high pseudorapidity regions, 2.3 < |eta| < 2.7, is performed by 16 four-layered Cathode Strip Chambers on each end-cap. These are multi-wire proportional chambers with segmented cathodes providing excellent spatial resolution and high counting rate capability. The second cathode of each layer is coarsely segmented, providing the transverse coordinate. The detector level performance of the system is presented. The installation and commissioning effort for the Cathode Strip Chambers is described. Finally, the in situ performance is briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.

60 APPLIED LIFE SCIENCES↗

X-ray modulation transfer functions of photostimulable phosphor image plates and scanners

The modulation transfer functions of two types of photostimulable phosphor image plates were determined in the 10 keV to 50 keV x-ray energy range using a resolution test pattern with up to 10 line pairs per mm (LP/mm) and a wavelength dispersive x-ray spectrometer. Techniques were developed for correcting for the partial transmittance of the high energy x rays through the lead bars of the resolution test pattern, and the modulation transfer function (MTF) was determined from the measured change in contrast with LP/mm values. The MTF was convolved with the slit function of the image plate scanner, and the resulting point spread functions (PSFs) were in good agreement with the observed shapes and widths of x-ray spectral lines and with the PSF derived from edge spread functions. The shapes and the full width at half-maximum (FWHM) values of the PSF curves of the Fuji Superior Resolution (SR) and Fuji Maximum Sensitivity (MS) image plate detectors, consisting of the image plate and the scanner, determined by the three methods gave consistent results: The SR PSF is Gaussian with 0.13 mm FWHM, and the MS PSF is Lorentzian with 0.19 mm FWHM. These techniques result in the accurate determination of the spatial resolution achievable using image plate and scanner combinations and enable the optimization of spatial resolution for x-ray spectroscopy and radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density fluctuation measurements using beam emission spectroscopy on Heliotron J

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution {Delta}{rho} is less than {+-}0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The spatial resolving power of earth resources satellites: A review

The significance of spatial resolving power on the utility of current and future Earth resources satellites is critically discussed and the relative merits of different approaches in defining and estimating spatial resolution are outlined. It is shown that choice of a particular measure of spatial resolution depends strongly on the particular needs of the user. Several experiments have simulated the capabilities of future satellite systems by degradation of aircraft images. Surprisingly, many of these indicated that improvements in resolution may lead to a reduction in the classification accuracy of land cover types using computer assisted methods. However, where the frequency of boundary pixels is high, the converse relationship is found. Use of imagery dependent upon visual interpretation is likely to benefit more consistently from higher resolutions. Extraction of information from images will depend upon several other factors apart from spatial resolving power: these include characteristics of the terrain being sensed, the image processing methods that are applied as well as certain sensor characteristics.

Townshend, J. R. G.↗

High-Resolution, Two-Wavelength Pyrometer

Modified two-color pyrometer measures temperatures of objects with high spatial resolution. Image focused on hole 0.002 in. (0.05 mm) in diameter in brass sheet near end of bundle, causing image to be distributed so fibers covered by defocused radiation from target. Pinhole ensures radiation from only small part of target scene reaches detector, thus providing required spatial resolution. By spreading radiation over bundle, pinhole ensures entire active area of detectors utilized. Produces signal as quiet as conventional instruments but with only 1/64 input radiation.

Bickler, Donald B.↗

Upgrade of absolute extreme ultraviolet diagnostic on J-TEXT

The absolute extreme ultraviolet (AXUV) diagnostic system is used for radiation observation on J-TEXT tokamak [J. Zhang, G. Zhuang, Z. J. Wang, Y. H. Ding, X. Q. Zhang, and Y. J. Tang, Rev. Sci. Instrum. 81, 073509 (2010)]. The upgrade of the AXUV system is aimed to improve the spatial resolution and provide a three-dimensional image on J-TEXT. The new system consists of 12 AXUV arrays (4 AXUV16ELG arrays, 8 AXUV20ELG arrays). The spatial resolution in the cross-section is 21 mm for the AXUV16ELG arrays and 17 mm for the AXUV20ELG arrays. The pre-amplifier is also upgraded for a higher signal to noise ratio. By upgrading the AXUV imaging system, a more accurate observation on the radiation information is obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Estimating the Photonics Budget, Resolution, and Signal Requirements for a Multi-Monochromatic X-ray Imager

This document examines the performance of a generic flat-mirror multimonochromatic imager (MMI), with special emphasis on existing instruments at NIF and Omega. We begin by deriving the standard equation for the mean number of photons detected per resolution element. The pinhole energy bandwidth is a contributing factor; this is dominated by the finite size of the source and may be considerable. The most common method for estimating the spatial resolution of such a system (quadrature addition) is, technically, mathematically invalid for this case. However, under the proper circumstances it may produce good estimates compared to a rigorous calculation based on the convolution of point-spread functions. Diffraction is an important contribution to the spatial resolution. Common approximations based on Fraunhofer (farfield) diffraction may be inappropriate and misleading, as the instrument may reside in multiple regimes depending upon its configuration or the energy of interest. It is crucial to identify the correct diffraction regime; Fraunhofer and Fresnel (near-field) diffraction profiles are substantially different, the latter being considerably wider. Finally, we combine the photonics and resolution analyses to derive an expression for the minimum signal level such that the resulting images are not dominated by photon statistics. This analysis is consistent with observed performance of the NIF MMI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗