Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Experimental Demonstration of Single-Site Addressability in a Two-Dimensional Optical Lattice

We demonstrate single-site addressability in a two-dimensional optical lattice with 600 nm lattice spacing. After loading a Bose-Einstein condensate in the lattice potential, we use a focused electron beam to remove atoms from selected sites. The patterned structure is subsequently imaged by means of scanning electron microscopy. This technique allows one to create arbitrary patterns of mesoscopic atomic ensembles. We find that the patterns are remarkably stable against tunneling diffusion. Such microengineered quantum gases are a versatile resource for applications in quantum simulation, quantum optics, and quantum information processing with neutral atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum confining excitons with an electrostatic moiré superlattice

Quantum confining excitons has been a persistent challenge in the pursuit of strong exciton interactions and quantum light generation. Unlike electrons, which can be readily controlled via electric fields, imposing strong nanoscale potentials on excitons to enable quantum confinement has proven challenging. In this study, we utilize piezoelectric force microscopy to image the domain structures of twisted hexagonal boron nitride (h – BN), revealing evidence of strong in-plane electric fields at the domain boundaries. By placing a monolayer MoSe 2 only one to two nanometers away from the twisted h – BN interface, we observe energy splitting of neutral excitons and Fermi polarons by several millielectronvolts at the moiré domain boundaries. By directly correlating local structural and optical properties, we attribute such observations to excitons confined in a nanoscale one-dimensional electrostatic potential created by the strong in-plane electric fields at the moiré domain boundaries. Intriguingly, this 1D quantum confinement results in pronounced polarization anisotropy in the excitons’ reflection and emission, persistent to temperatures as high as ~80 Kelvins. Furthermore, these findings open new avenues for exploring and controlling strongly interacting excitons for classical and quantum optoelectronics.

2-dimensional systems↗

Tracking Non-rigid Structures in Computer Simulations

A key challenge in tracking moving objects is the correspondence problem, that is, the correct propagation of object labels from one time step to another. This is especially true when the objects are non-rigid structures, changing shape, and merging and splitting over time. In this work, we describe a general approach to tracking thousands of non-rigid structures in an image sequence. We show how we can minimize memory requirements and generate accurate results while working with only two frames of the sequence at a time. We demonstrate our results using data from computer simulations of a fluimix problem.

99 GENERAL AND MISCELLANEOUS↗

A Comparison of Emerging and Industry Benchmark Photovoltaic Backsheets Between Different Outdoor Locations

Recent interest within the photovoltaic (PV) module industry is largely directed toward enhanced lifetimes in the field, balanced with improved recyclability. Traditionally, fluoropolymer-based backsheets have been used, however, are difficult to recycle. Emerging polyolefin (PO)-based backsheets are more recyclable and can be formulated to be robust. Properties of different fluoropolymer- and non-fluoropolymer-based backsheet coupons and in encapsulated silicon mini modules that have been fielded in Albuquerque, NM and Cocoa, FL are reported here. Seven backsheets were examined: two novel PO's, TPT, APO, PPE, AAA, and KPf. Methods of examination include module electrical performance (I - V flash test), surface morphology (optical microscope and gloss), polymer chemical structure (FTIR), EL imaging, mechanical tensile testing, DC breakdown voltage, DSC (phase transitions), and optical performance (reflectance spectra).

industries↗

The Value of Information From Horizontal Distributed Acoustic Sensing Compared to Multicomponent Geophones Via Machine Learning

Abstract Faults play an important role in recharging many geothermal reservoirs, and seismic information can image the locations of these faults. The value of information (VOI) metric is used to objectively quantify and compare the value of two types of seismic receiver data via a machine learning approach. The demonstrated VOI methodology is novel by including spatial models from seismic data and obtaining the information statistics from machine learning. Our two-dimensional numerical experiments compare images created from sparsely spaced (80 m), two-component geophone sampling to high spatial resolution (1 m), single-component DAS. We used a three-fold cross validation of a U-Net convolutional neural networks to achieve average classification statistics. The results suggest that when horizontal sources are utilized, geophones and DAS identify reflectors and non-reflectors at roughly the same rate. The average F1 score for horizontal DAS is 0.939 and 0.931 for geophones. For images created from a vertical source, DAS performed marginally better (F1 = 0.919) than geophones (F1 = 0.877). Our transferrable methodology can provide guidance on which acquisition scenarios can improve images of important structures in the subsurface and present an efficient method for obtaining reliability statistics from high-dimensional, spatial data.

Energy & Fuels↗

Time stamping of single optical photons with 10 ns resolution

High spatial and temporal resolution are key features for many modern applications, e.g. mass spectrometry, probing the structure of materials via neutron scattering, studying molecular structure, etc. Fast imaging also provides the capability of coincidence detection, and the further addition of sensitivity to single optical photons with the capability of timestamping them further broadens the field of potential applications. Here, photon counting is already widely used in X-ray imaging, where the high energy of the photons makes their detection easier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗

SU-E-T-624: Quantitative Evaluation of 2D Versus 3D Dosimetry for Stereotactic Volumetric Modulated Arc Delivery Using COMPASS

Purpose: The purpose of this study was to evaluate quantitatively 2D versus 3D dosimetry for stereotactic volumetric modulated arc delivery using COMPASS with 2D array. Methods: Twenty-five patients CT images and RT structures of different sites like brain, head and neck, thorax, abdomen and spine were taken from Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in Cyberknife. For each patient, linac based VMAT stereotactic plans were generated in Monaco TPS v 3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5-20Gy/fraction.TPS calculated VMAT plan delivery accuracy was quantitatively evaluated with COMPASS measured dose and calculated dose based on DVH metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using Multicube. Results: For each site, D{sub 9} {sub 5} was achieved with 100% of prescription dose with maximum 0.05SD. Conformity index (CI) was observed closer to 1.15 in all cases. Maximum deviation of 2.62 % was observed for D{sub 9} {sub 5} when compared TPS versus COMPASS measured. Considerable deviations were observed in head and neck cases compare to other sites. The maximum mean and standard deviation for D{sub 9} {sub 5}, average target dose and average gamma were -0.78±1.72, -1.10±1.373 and 0.39±0.086 respectively. Numbers of pixels passing 2D fluence verification were observed as a mean of 99.36% ±0.455 SD with 3% dose difference and 3mm DTA. For critical organs in head and neck cases, significant dose differences were observed in 3D dosimetry while the target doses were matched well within limit in both 2D and 3D dosimetry. Conclusion: The quantitative evaluations of 2D versus 3D dosimetry for stereotactic volumetric modulated plans showed the potential of highlighting the delivery errors. This study reveals that COMPASS 3D dosimetry is an effective tool for patient specific quality assurance compared to 2D fluence verification.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-01: IROC Houston QA Center’s Anthropomorphic Proton Phantom Program

Purpose: To describe the proton phantoms that IROC Houston uses to approve and credential proton institutions to participate in NCI-sponsored clinical trials. Methods: Photon phantoms cannot necessarily be used for proton measurements because protons react differently than photons in some plastics. As such plastics that are tissue equivalent for protons were identified. Another required alteration is to ensure that the film dosimeters are housed in the phantom with no air gap to avoid proton streaming. Proton-equivalent plastics/materials used include RMI Solid Water, Techron HPV, blue water, RANDO soft tissue material, balsa wood, compressed cork and polyethylene. Institutions wishing to be approved or credentialed request a phantom and are prioritized for delivery. At the institution, the phantom is imaged, a treatment plan is developed, positioned on the treatment couch and the treatment is delivered. The phantom is returned and the measured dose distributions are compared to the institution’s electronically submitted treatment plan dosimetry data. Results: IROC Houston has developed an extensive proton phantom approval/credentialing program consisting of five different phantoms designs: head, prostate, lung, liver and spine. The phantoms are made with proton equivalent plastics that have HU and relative stopping powers similar (within 5%) of human tissues. They also have imageable targets, avoidance structures, and heterogeneities. TLD and radiochromic film are contained in the target structures. There have been 13 head, 33 prostate, 18 lung, 2 liver and 16 spine irradiations with either passive scatter, or scanned proton beams. The pass rates have been: 100%, 69.7%, 72.2%, 50%, and 81.3%, respectively. Conclusion: IROC Houston has responded to the recent surge in proton facilities by developing a family of anthropomorphic phantoms that are able to be used for remote audits of proton beams. Work supported by PHS grant CA10953 and CA081647.

60 APPLIED LIFE SCIENCES↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SIRT-FILTER v1.0.0

Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).

PELT, DANIEL↗

Active–Source Seismic Tomography at the Brady Geothermal Field, Nevada, with Dense Nodal and Fiber–Optic Seismic Arrays

We deployed a dense seismic array to image the shallow structure in the injection area of the Brady Hot Springs geothermal power plant in western Nevada. The array was composed of 238 three-component, 5 Hz nodal instruments, 8700 m of distributed acoustic sensing (DAS) fiber-optic cable (FOC) installed horizontally in surface trenches, and 400 m of FOC installed vertically in a borehole. The geophone array had about 60 m instrument spacing in the target zone, whereas DAS channel separations were about 1 m with an averaging (gauge) length of 10 m. The acquisition systems provided 15 days of continuous records, including active-source and ambient noise signals. A large vibroseis truck was operated at 196 locations, exciting a swept-frequency signal from 5 to 80 Hz over 20 s using three vibration modes (vertical, longitudinal, and transverse), with three sweeps per mode at each site. Sweeps were repeated up to four times at each site during four different stages of power plant operation: normal operation, shutdown, high and oscillatory injection and production, and normal operation. After removal of the sweep signal from the raw data, the first P-wave arrivals were automatically picked using a combination of methods. Here, the travel times were then used to invert for the 3D P-wave velocity structure. Models with 100 m horizontal and 20–50 m vertical node spacing were obtained, covering an area 2000 m by 1300 m, with acceptable resolution extending to about 250 m below surface. The travel-time data were fit to a root mean square (rms) misfit of 31 ms, close to our estimated picking uncertainty. Lateral boundaries between high and low velocity zones agree relatively well with the location of local faults from previous studies, and low near-surface velocities are associated with faults and fumarole locations. A sharp increase in velocity from < 1500 to > 2000 m/s at approximately 50 m below the ground surface in many parts of the study area may indicate a shallower water table than expected for the region.

15 GEOTHERMAL ENERGY↗

Optimization of Forward Wave Modeling on Contemporary HPC Architectures

Reverse Time Migration (RTM) is one of the main approaches in the seismic processing industry for imaging the subsurface structure of the Earth. While RTM provides qualitative advantages over its predecessors, it has a high computational cost warranting implementation on HPC architectures. We focus on three progressively more complex kernels extracted from RTM: for isotropic (ISO), vertical transverse isotropic (VTI) and tilted transverse isotropic (TTI) media. In this work, we examine performance optimization of forward wave modeling, which describes the computational kernels used in RTM, on emerging multi- and manycore processors and introduce a novel common subexpression elimination optimization for TTI kernels. We compare attained performance and energy efficiency in both the single-node and distributed memory environments in order to satisfy industry’s demands for fidelity, performance, and energy efficiency. Moreover, we discuss the interplay between architecture (chip and system) and optimizations (both on-node computation) highlighting the importance of NUMA-aware approaches to MPI communication. Ultimately, our results show we can improve CPU energy efficiency by more than 10× on Magny Cours nodes while acceleration via multiple GPUs can surpass the energy-efficient Intel Sandy Bridge by as much as 3.6×.

97 MATHEMATICS AND COMPUTING↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Data Summarization and Inference at Scale

This is the final report for the DOE ASCR grant SC-0022260, Data Summarization and Inference at Scale, PI: Alex Pothen, Purdue University. The goal of the project was to solve data-intensive and compute-intensive problems in the physical sciences, engineering, information science, data science, etc. by designing and implementing new algorithms that could work with a subset of the data. The four subgoals were: (a) The solution of problems where the data is too large to be stored in the memory of a computer. In this streaming model of computation, the data arrives as a stream of elements to the computer, each element is processed as it arrives, and a decision is made to discard the data or to store it; only a small subset of the data proportional to the size of the output solution is stored, and when all the data has been streamed, a solution to the problem is computed from the stored subset. (b) The use of machine learning methods to compute solutions to data-intensive problems. The use of GPUs is critical to obtain high performance on machine learning tasks, but their memory sizes are smaller relative to that of CPUs. For large-scale problems, the data is sampled many times, and small samples are used with repetition, for robustness, to compute solutions to inference tasks. This sampling reduces the memory required to solve the problem, but attention is needed to avoid slow convergence to the solutions, and reduced accuracy of inference. We propose submodular optimization, Large Language Models, and physics-informed neural networks to enable GPU computations here. (c) Modeling and visualization of high-dimensional data using interpretable features. Clinical proteomic data sets from immunology for the detection of cancer and other diseases are temporal and high-dimensional, and algorithms for visualizing these data sets using clinically interpretable features are lacking. We propose methods that compute distances based on the optimal transportation problem and graph edit distances to address this problem. We also propose the use of optimal transport-based distances, spatial statistics, and network structure to classify image data sets, We apply these algorithms to electron micrographs of the peripheral nervous system in the digestive tract. (d) The design of data-intensive algorithms on emerging architectures, specifically, noisy, intermediate-scale quantum (NISQ) devices. Quantum computers offer the possibility of exploring large solution spaces due to the principle of superposition, but current quantum computers are limited by few qubits, short coherence times due to noise, poor interconections among the qubits, etc. We propose the use of the divide and conquer paradigm to solve large-scale problems, wherein collections of small subproblems are solved on the quantum devices, and the solutions to the subproblems are integrated into a solution for the original problem on a classical computer.

97 MATHEMATICS AND COMPUTING↗

Atom Probe Tomography for Catalysis Applications: A Review

Atom probe tomography is a well-established analytical instrument for imaging the 3D structure and composition of materials with high mass resolution, sub-nanometer spatial resolution and ppm elemental sensitivity. Thanks to recent hardware developments in Atom Probe Tomography (APT), combined with progress on site-specific focused ion beam (FIB)-based sample preparation methods and improved data treatment software, complex materials can now be routinely investigated. From model samples to complex, usable porous structures, there is currently a growing interest in the analysis of catalytic materials. APT is able to probe the end state of atomic-scale processes, providing information needed to improve the synthesis of catalysts and to unravel structure/composition/reactivity relationships. This review focuses on the study of catalytic materials with increasing complexity (tip-sample, unsupported and supported nanoparticles, powders, self-supported catalysts and zeolites), as well as sample preparation methods developed to obtain suitable specimens for APT experiments.

36 MATERIALS SCIENCE↗

Thermoelectric Properties and Morphology of Si/SiC Thin-Film Multilayers Grown by Ion Beam Sputtering

Multilayers (MLs) of 31 bi-layers and a 10-nm layer thickness each of Si/SiC were deposited on silicon, quartz and mullite substrates using a high-speed, ion-beam sputter deposition process. The samples deposited on the silicon substrates were used for imaging purposes and structural verification as they did not allow for accurate electrical measurement of the material. The Seebeck coefficient and the electrical resistivity on the mullite and the quartz substrates were reported as a function of temperature and used to compare the film performance. The thermal conductivity measurement was performed for ML samples grown on Si, and an average value of the thermal conductivity was used to find the figure of merit, zT, for all samples tested. X-ray diffraction (XRD) spectra showed an amorphous nature of the thin films. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to study the film morphology and verify the nature of the crystallinity. The mobility of the multilayer films was measured to be only 0.039 to 1.0 cm 2 /Vs at room temperature. The samples were tested three times in the temperature range of 300 K to 900 K to document the changes in the films with temperature cycling. The highest Seebeck coefficient is measured for a Si/SiC multilayer system on quartz and mullite substrates and were observed at 870 K to be roughly -2600 μV/K due to a strain-induced redistribution of the states’ effect. The highest figure of merit, zT, calculated for the multilayers in this study was 0.08 at 870 K.

36 MATERIALS SCIENCE↗