Search NASA⌕ Search

SEARCH · Search NASA

Results for “system code validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Real-time estimation and control of divertor surface heat flux on the DⅢ-D tokamak

We report Future tokamaks will require robust technologies for the mitigation of heat exhaust onto the plasma-facing components. As a first step towards this development, a system has been developed at DIII-D that estimates and controls in real-time the heat flux to the PFCs. Real-time estimation of the peak power flux from this model-based approach is validated with off-line infra-red measurements for various DIII-D plasma discharges. A nonlinear free-boundary simulation code (GSevolve) is used for simulating the closed loop response and for the off-line determination of the control parameters. The implementation and first experimental results of the application during the DIII-D plasma campaign are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and construction of the MUSE permanent magnet stellarator

This paper documents the design and construction of MUSE, the world's first permanent magnet (PM) stellarator and the first quasi-axisymmetric experiment. The purpose of MUSE is to develop and assess a new way of building optimised stellarators that uses simple planar coils PMs. Our PM optimisation algorithm consists of initialising a geometry to pack dipoles densely, running the FAMUS code to minimise surface field error subject to PM constraints and applying discrete jumps to reach a physically realisable solution. FAMUS treats the PM system as a set of ideal point dipoles. From there we construct finite-volume magnet towers to be housed in 3D-printed PM holders. We describe the design of the PM holders, which were validated by laser metrology. We analyse the effects of finite permeability, sensitivity to perturbations and magnetostatic forces. An exact analytic formula for the magnetic field from a finite-volume PM tower is presented to compute PM–PM forces and stress on the PM holder. Stellarator construction is complete and experiments are underway.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Application of Parallel Betweenness Centrality to Power Grid Contingency Analysis

In Energy Management Systems, contingency analysis is commonly performed for identifying and mitigating potentially harmful power grid component failures. The exponentially increasing combinatorial number of failure modes imposes a significant computational burden for massive contingency analysis. It is critical to select a limited set of high-impact contingency cases within the constraint of computing power and time requirements to make it possible for real-time power system vulnerability assessment. In this paper, we present a novel application of parallel betweenness centrality to power grid contingency selection. We cross-validate the proposed method using the model and data of the western US power grid, and implement it on a Cray XMT system - a massively multithreaded architecture - leveraging its advantages for parallel execution of irregular algorithms, such as graph analysis. We achieve a speedup of 55 times (on 64 processors) compared against the single-processor version of the same code running on the Cray XMT. We also compare an OpenMP-based version of the same code running on an HP Superdome shared-memory machine. The performance of the Cray XMT code shows better scalability and resource utilization, and shorter execution time for large-scale power grids. This proposed approach has been evaluated in PNNL’s Electricity Infrastructure Operations Center (EIOC). It is expected to provide a quick and efficient solution to massive contingency selection problems to help power grid operators to identify and mitigate potential widespread cascading power grid failures in real time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Beam Stability Analysis for the EIC

This document summarizes work done in WBS 6.02.02 during FY23. Additional details can be found in the EIC overview paper presented at IPAC’23 [1], and the references therein. Progress has been made in the ESR and HSR lattice design, dynamic aperture optimization, and the RCS lattice design. The impedance and Collective effects are progressing and include the impedance optimization process of the vacuum systems for RCS, HSR, and ESR; collective effects studies; collective effects and beam-beam interaction; coupled bunch instabilities and the crab cavities; low-level RF feedback system design and beam-ion instability. The reversed phasing RF system has been numerically studied for the ESR to mitigate Robinson instability and demonstrate reliable stable beam operation. Various codes, including C++, SPACE [2], ELEGANT [3], and Mbtrack2 [4] have been employed to benchmark the results. The simulation of HSR bunch splitting with beam loading has been performed at 275 GeV energy. The evaluation of Beam Position Monitors aimed to validate their expected performance, with the primary objective being to verify their accuracy. Calculations of Electron Polarization in the ESR, RCS, and HSR are showing good progress. In the RCS, preliminary studies indicate excellent polarization transmission over intrinsic spin resonances, achieving over 90% transmission with improved performance compared to the previous lattice. Preliminary simulations in the ESR indicate encouraging results in minimizing depolarization and improving equilibrium polarization.

43 PARTICLE ACCELERATORS↗

Agenda toward the development of a rational noise descriptor system relevant to human annoyance by en route aircraft noise

A rational, internationally consistent, noise descriptor system is needed to express existing and predicted en route aircraft noise levels in terms closely correlated to the annoyance perceived by people and physiologically identifiable in people, to provide guidance for aircraft and powerplant design, flight management, land-use planning, and building codes. Expanding on previous discussions, a new comprehensive statement of the specific questions that must be resolved by needed research, and the nature and quality of proof that must be adduced to justify further steps toward the drafting and adoption of new international en route aircraft-noise standards is sought. The single noise-descriptor system envisioned must be valid for widely varying aircraft-noise frequency spectra, including time-variant components and agreeable and disagreeable discrete tones and combinations of tones. The measures and criteria established by the system must be valid at high and low immission levels, at high and low ambient noise levels, for great and small number of noise events, and outdoors and indoors.

Garbell, Maurice A.↗

An Object-Oriented Interface to the CCSDS Ground Telecommand Services

The Telecommand Data Routing and Channel Services defined by the Consultative Committee for Space Data Systems (CCSDS) are flexible enough to support a myriad of commanding models. Because the standard is so broad, the traditional approach has been to implement only the portion of the standard needed by the particular spacecraft being tested/operated. Tasked with providing Telecommand Services for an entire class of spacecraft, where each spacecraft may choose any valid CCSDS commanding model, NASA Code 584 designed a common architecture capable of handling the full CCSDS protocol. The solution uses another CCSDS standard - the Standard Formatted Data Unit (SFDU) as the interface to the Telecommand Services. SFDUs provide a consistent way of labelling data objects, as well as allowing data objects to encapsulate other data objects. The resulting interface is: - Flexible: The full Data Routing and Channel Services are available via a single interface. The client (i.e. the command source) may enter commands at any layer within the protocol stack, specify any of the data aggregation or segmentation methods, and dynamically set any configuration parameter defined in the standard. - Object-oriented: Each object specifies both the data and the actions to be performed with the data. An object may contain other objects. - Expandable: New capabilities are added by defining new objects. Objects pass thru the protocol layers until they reach the applicable layer. The resulting design is: - Modular: The logic for each protocol layer is contained in a separate Application Program Interface (API). The objects used for the external interface are also used for communication between layers. - Distributable: The design can be split along any layer boundary for distribution across multiple machines. The objects ensure data consistency across platforms. This paper describes the SFDU-based interface and the resulting protocol implementation. The implementation is currently used by NASA (National Aeronautics and Space Administration) for integration & test of the microwave Anisotropy Probe (MAP) and Earth observer-I (EO-l) spacecraft. It will be used for post-launch operations of these spacecraft as well as the Imager for Magnetopause to Aurora Global Exploration (IMAGE) spacecraft.

Ray, Timothy Joseph↗

Benchmarking Gas Path Diagnostic Methods: A Public Approach

Recent technology reviews have identified the need for objective assessments of engine health management (EHM) technology. The need is two-fold: technology developers require relevant data and problems to design and validate new algorithms and techniques while engine system integrators and operators need practical tools to direct development and then evaluate the effectiveness of proposed solutions. This paper presents a publicly available gas path diagnostic benchmark problem that has been developed by the Propulsion and Power Systems Panel of The Technical Cooperation Program (TTCP) to help address these needs. The problem is coded in MATLAB (The MathWorks, Inc.) and coupled with a non-linear turbofan engine simulation to produce "snap-shot" measurements, with relevant noise levels, as if collected from a fleet of engines over their lifetime of use. Each engine within the fleet will experience unique operating and deterioration profiles, and may encounter randomly occurring relevant gas path faults including sensor, actuator and component faults. The challenge to the EHM community is to develop gas path diagnostic algorithms to reliably perform fault detection and isolation. An example solution to the benchmark problem is provided along with associated evaluation metrics. A plan is presented to disseminate this benchmark problem to the engine health management technical community and invite technology solutions.

Simon, Donald L.↗

Comparative Study of Active Flow Control Strategies for Lift Enhancement of a Simplified High-Lift Configuration

Numerical simulations have been performed for a simplified high-lift (SHL) version of the Common Research Model (CRM) configuration, where the Fowler flaps of the conventional high-lift (CRM-HL) configuration are replaced by a set of simple hinged flaps. These hinged flaps are equipped with integrated modular active flow control (AFC) cartridges on the suction surface, and the resulting geometry is known as the CRM-SHL-AFC configuration. The main objective is to make use of AFC devices on the CRM-SHL-AFC configuration to recover the aerodynamic performance (lift) of the CRM-HL configuration. In the current paper, a Lattice Boltzmann method-based computational fluid dynamics (CFD) code, known as PowerFLOWQ® is used to simulate the entire flow field associated with the CRM-SHL-AFC configuration equipped with several different types of AFC devices. The transonic version of the PowerFLOWQ® code that has been validated for high speed flows is used to accurately simulate the flow field generated by the high-momentum actuators required to mitigate reversed flow regions on the suction surfaces of the main wing and the flap. The numerical solutions predict the expected trends in aerodynamic forces as the actuation levels are increased. More efficient AFC systems and actuator arrangements emerged based on the parametric studies performed prior to a Fall 2018 wind tunnel test. Preliminary comparisons of the numerical solutions for lift and surface pressures are presented here with the experimental data, demonstrating the usefulness of CFD for predicting the flow field and lift characteristics of AFC-enabled high-lift configurations.

Vatsa, Veer N.↗

Close out the Critical Commitment for System Wide Safety’s Technical Challenge 3 (TC 3)

- Deliver validated methods and recommended practices to reduce certification costs for ground and onboard vehicle guidance and control systems through expanded acceptability of analysis as evidence for certification FY 2022. - Communicate results to maximize public awareness of the research and transfer capabilities via a set of on-demand training seminars and supporting materials including reports, publications and open source software codes where applicable.

Joseph C Coughlan↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This report summarizes the work done to validate the droplet entrainment and de-entrainment models as well as two-phase closure models in the CTF code by comparison with experimental data obtained at Riso National Laboratory. The Riso data included a series of over 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions were set so that the majority of cases were in the annular/mist ow regime. Measurements included liquid lm ow rate, droplet ow rate, lm thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet ow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor and entrained liquid ow fractions, pressure drop per unit length, and liquid lm thickness. The entire process of generating CTF input decks, running cases, extracting data, and generating comparison plots was scripted using Python and Matplotlib for a completely automated validation process. All test cases and scripting tools have been committed to the COBRA-TF master repository and selected cases have been added to the continuous testing system to serve as regression tests. The dierences between the CTF- and experimentally-calculated ow fraction values were con- sistent with previous calculations by Wurtz, who applied the same entrainment correlation to the same data. It has been found that CTF's entrainment/de-entrainment predictive capability in the annular/mist ow regime for this particular facility is comparable to the licensed industry code, COBRAG. While lm and droplet predictions are generally good, it has been found that accuracy is diminished at lower ow qualities. This nding is consistent with the noted deciencies in the Wurtz entrainment model employed by CTF. The CTF predicted two-phase pressure drop in the annular/mist ow regime has been found to be highly inaccurate, exhibiting a clear bias with respect to the experimental data. This inaccuracy led to an investigation that revealed deciencies in the implementation of the annular/mist interfacial friction model, which should be investigated further in the future. Looking to published COBRAG results for this same facility reveal it exhibits no bias with regard to experimental pressure drop results. In addition to the problems with pressure drop prediction, the lm thickness was also signicantly under-predicted by CTF compared to both experimental data and Wurtz's analytical calculations. Film thickness is calculated using a simple geometric relationship and lm void fraction in CTF, which is dependent on slip ratio and interfacial friction. It is possible that the issues aecting the pressure drop and lm void prediction are related.

97 MATHEMATICS AND COMPUTING↗

Experimental results from the VENUS-F critical reference state for the GUINEVERE accelerator driven system project

The GUINEVERE (Generation of Uninterrupted Intense Neutron pulses at the lead Venus Reactor) project was launched in 2006 within the framework of FP6 EUROTRANS in order to validate on-line reactivity monitoring and subcriticality level determination in Accelerator Driven Systems. Therefore the VENUS reactor at SCK.CEN in Mol (Belgium) was modified towards a fast core (VENUS-F) and coupled to the GENEPI-3C accelerator built by CNRS The accelerator can operate in both continuous and pulsed mode. The VENUS-F core is loaded with enriched Uranium and reflected with solid lead. A well-chosen critical reference state is indispensable for the validation of the on-line subcriticality monitoring methodology. Moreover a benchmarking tool is required for nuclear data research and code validation. In this paper the design and the importance of the critical reference state for the GUINEVERE project are motivated. The results of the first experimental phase on the critical core are presented. The control rods worth is determined by the rod drop technique and the application of the Modified Source Multiplication (MSM) method allows the determination of the worth of the safety rods. The results are implemented in the VENUS-F core certificate for full exploitation of the critical core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of new depletion capabilities and ENDF/B-VII data libraries in Scale

New isotopic depletion capabilities and ENDF/B-VII data libraries have been implemented in the recent release 6.1 of Scale, a comprehensive modeling and simulation suite for nuclear safety analysis and design developed and maintained by Oak Ridge National Laboratory. An assessment of the effect of these developments on the code performance is the subject of this paper. The analysis is focused on evaluating the code performance in predicting isotopic compositions in spent nuclear fuel by using an extensive, measured isotopic assay database. The analysis results obtained using the latest ENDF/B-VII cross-section data and different resonance processing methods in Scale are compared to the results of previous validation studies that used ENDF/B-V data. The performance of Scale depletion capabilities with respect to other computational systems is assessed based on recent published results that were obtained using ENDF/B-VII libraries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of ITER non-activation phase operation scenarios

Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into He plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.

60 APPLIED LIFE SCIENCES↗

Research and Development Roadmaps for Liquid Metal Cooled Fast Reactors – Draft for Public Comment

This report provides the roadmaps for two fast reactor concepts, the Sodium-cooled Fast Reactor (SFR) and the Lead-cooled Fast Reactor (LFR). The roadmaps are generic, i.e., not specific to a particular vendor’s design, but vendor design information may have been used as a representative of the concept family. The SFR technology is mature enough for commercial demonstration by the early 2030s, and the remaining key activities and R&D needs over the next five years are generally related to the completion of qualification of fuel and structural materials, validation of reactor design codes and methods, and support of the licensing frameworks. The LFR’s technology is instead less-mature and will be at the engineering demonstration stage by the early 2030s. Key LFR technology development activities for the acceleration of the engineering demonstration of the LFR will focus on resolving remaining design challenges and demonstrating the viability of systems and components in the integral system, which will be done in parallel with addressing the gaps shared with SFR technology. As discussed in the Advanced Demonstration and Test Reactor Options Study, the R&D approaches and timelines presented here assume that, for the first module demonstration, vendors would pursue a two-step licensing process based on 10CFR Part 50.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

APOLLO: a facility-scale differentiable virtual accelerator for Fermilab

As the design complexity of modern accelerators grows, there is more interest in using advanced simulations that have fast execution time or yield additional insights like gradients. The FAST/IOTA facility has been working on implementing and experimentally validating an end-to-end digital twin that is both fast and gradient-aware, allowing for rapid prototyping of new software and experiments with minimal beam time costs. Our framework integrates physics and ML codes for linac and ring simulation through a set of generic interfaces between surrogate and physics-based sections. To reproduce device inputs and outputs, system state is exposed as a deterministic discrete event simulator. Because Fermilab is undergoing control system transition, both EPICS and ACNET frontends are supported. Recently, we have begun transitioning to a new community lattice standard, PALS, as well as developing standardized infrastructure for data ingest and normalization to prepare for model calibration during FAST proton injector commissioning. We discuss implementation details as well as challenges, and future plans to extend modelling to main complex proton accelerators like PIPII and Booster.

Kuklev, Nikita [Fermilab]↗