Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Retrograde Transvenous Embolization Technique with Balloon-Assisted Arterial Aspiration for a Peripheral Arteriovenous Malformation with a Venous Pouch

Management of arteriovenous malformations (AVMs) is challenging, and there is no consensus regarding either the ideal approach or the treatment timing. Percutaneous embolization is the most frequent approach currently used and is considered the first-line technique for AVMs. There is an ongoing discussion about the best technical approach to embolize AVMs. AVMs associated with a dominant outflow vein (DOV) are rare. Embolization of both the DOV and the nidus is considered more effective. Herein, we report a novel technique of transvenous embolization of a DOV under negative pressure from an arterial balloon catheter in a case of a peripheral AVM. This technique allows the embolization of the DOV and the nidus retrogradely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. After placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stenting the Upper/Cervical Oesophagus with a Proximal Deployment Cervical Oesophageal Stent: Technique and Outcomes

Introduction: Proximal oesophageal stent deployment continues to provide challenges due to the proximity of the upper oesophageal sphincter and the associated subsequent complications such as globus sensation and stent migration. Patients with cervical oesophageal cancer have previously had limited stenting options available to them with a paucity of the literature describing the radiological technique for successfully placing these high-risk stents. In this paper, we present our experience using the Taewoong Niti-S CERVICAL Oesophageal Stent. Materials and Methods: We describe our method for stent deployment highlighting the importance of pre-procedural planning in ensuring an adequate proximal landing zone for the short proximal flare of the stent. Furthermore, we outline how we have adapted our placement technique to incorporate a routine pre-dilatation stage which has optimised retrieval of the proximal to distal deployment system. Results: We have placed eight cervical oesophageal stents within our institution. Contrast swallows in all the patients following stent deployment have demonstrated free flow of contrast to the stomach with all patients reporting symptomatic relief and no foreign body/globus sensation. There has been one episode of stent migration but no incidence of oesophageal perforation or haemorrhage. Discussion: Evolution of stenting technique and the properties of the stents themselves are improving accuracy of stent placement in relation to the important landmark of the upper oesophageal sphincter. Conclusion: Stenting of cervical oesophageal malignancy has proved successful in our institution and provided symptom relief for a subset of palliative patients who were previously unable to benefit from oesophageal stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Giant Cystic Echinococcosis in Liver: Catheterization Technique in Patients with CE1 and CE3a

Purpose: This study aimed to evaluate the efficacy, safety, and follow-up results of the percutaneous treatment of cystic echinococcosis (CE) patients with giant hepatic cysts (at least one diameter > 10 cm). Methods: Between January 2013 and 2018, 31 CE patients with 34 giant cysts classified as CE1 or CE3a (Gharbi type 1 or 2) according to the World Health Organization criteria and treated with the catheterization technique were analyzed retrospectively. Results: Thirty-four giant hepatic cysts were treated using the catheterization technique. Technical success was 100%. One procedure was sufficient for 27 of these cysts, while six patients underwent a second procedure due to recurrence, recollection or complications; one did not accept a repeat procedure and decided to refer to surgery due to pain. Ten (29%) major complications developed. The overall clinical success was 97%. The mean follow-up period was 20 months (5–61 months), and the total reduction in the cyst volume was 92%. Conclusion: The catheterization technique is effective in treating giant CE with acceptable complication rates. Level of Evidence: Level 4, Clinical Investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Application of Synchrotron Techniques to the Study of Lithium-ion Batteries

This paper gives a brief review of the application of synchrotron X-ray techniques to the study of lithium-ion battery materials. The two main techniques are X-ray absorption spectroscopy (XAS) and high-resolution X-ray diffraction (XRD). Examples are given for in situ XAS and XRD studies of lithium-ion battery cathodes during cycling. This includes time-resolved methods. The paper also discusses the application of soft X-ray XAS to do ex situ studies on battery cathodes. By applying two signal detection methods, it is possible to probe the surface and the bulk of cathode materials simultaneously. Another example is the use of time-resolved XRD studies of the decomposition of reactions of charged cathodes at elevated temperatures. Measurements were done both in the dry state and in the presence of electrolyte. Brief reports are also given on two new synchrotron techniques. One is inelastic X-ray scattering, and the other is synchrotron X-ray reflectometry studies of the surface electrode interface (SEI) on highly oriented single crystal lithium battery cathode surfaces.

36 MATERIALS SCIENCE↗

A Square Pulse Thermoreflectance Technique for the Measurement of Thermal Properties

We report on a laser-based square pulse thermoreflectance (SPTR) technique for the measurement of thermal properties for a wide range of materials. SPTR adopts the pump-probe thermoreflectance principle to monitor the evolution of local temperature after square pulse excitation. The technique features a compact setup, high spatial resolution, and fast data collection. By comparing the acquired SPTR signals with a continuum heat transfer model, material thermal properties can be obtained. Taking advantage of various spot sizes and modulation frequencies, SPTR can measure both the thermal diffusivity and thermal conductivity of poorly to moderately conductive materials and the thermal conductivity of conductive materials with satisfactory accuracy, with potential to be applied to more conductive materials. The technique was validated on three materials: fused silica, single crystal CaF2 and single crystal nickel (with conductivities ranging from 1 W·m -1 ·K -1 to 100 W·m -1 ·K -1 ) with typical measurement errors of 5 % to 20 %. The leading sources of error have been identified by Monte Carlo simulations, and the primary limitations of SPTR are discussed. The compact, fiberized platform we describe here will allow instruments based on this methodology to be deployed in complex, multi-analytical environments for the type of high-throughput correlative analyses that are key to materials design and discovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Techniques Used to Detect DNA Binding Modes of Ruthenium(II) Complexes with Extended Phenanthroline Ring

This review describes the analytical techniques used to detect DNA-probes such as Ru(II) complexes with hetero cyclic imidazo phenanthroline (IP) ligands. Studies on drug-DNA interactions are useful biochemical techniques for visualization of DNA both in vitro and in vivo. The interactions of small molecules that binds to DNA are mainly classified into two major classes, one involving covalent binding and another non-covalent binding. Covalent binding in DNA can be irreversible and may leads to inhibition of all DNA processes which subsequently leads to cell death. Usually, covalent interactions leads to permanent changes in the structure of nucleic acids. The non-covalent interaction of molecules with DNA can be due to electrostatic interaction, intercalation and groove binding. These interactions of DNA probes can be explored by various spectroscopic techniques viz. UV–visible, emission, emission quenching spectroscopy, viscosity and thermal denaturation measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

42 ENGINEERING↗

Development of Biocomposite Superabsorbent Nanomaterials: Effect of Processing Technique

Nanoclay particles have been usually introduced into protein-based bioplastics to obtain composite materials, showing enhanced mechanical properties. However, the addition of partially exfoliated nanoclay particles in these protein matrices may also involve an increase of others properties such as water absorption capacity, which may lead to the obtention of super absorbent biodegradable materials. Processing technologies exerted a remarkable influence on the techno-functional properties of the soy-based bioplastics studied in this research. On the one hand, extrusion technique led to bioplastics which showed enhanced mechanical properties. On the other hand, injection moulding technique yielded to non-exfoliated nanoclay particles within the protein matrix, which involved improvements of water absorption capacity. The development of superabsorbent protein-based biodegradable materials implied a deep knowledge of physicochemical properties of proteins and processing conditions of bioplastics. Extrusion or injection moulding techniques could be selected to obtain tailored protein-based bioplastics with enhanced properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Excess Conductivity Investigation of Y{sub 3}Ba{sub 5}Cu{sub 8}O{sub 18±δ} Superconductors Prepared by Various Parameters of Planetary Ball Milling Technique

Superconducting samples of type Y{sub 3}Ba{sub 5}Cu{sub 8}O{sub 18±δ} were elaborated by using a planetary high-energy ball milling (HEBM) technique with various parameters. Phases, microstructure, and superconductivity have been examined using X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and electrical resistivity measurements. SEM investigation shows the occurrence of nanoentities embedded into the superconducting matrix for samples prepared by a ball milling technique. The main objective of this study is to investigate the influence of ball milling parameters on the fluctuation-induced conductivity (FIC). The electrical resistivity versus temperature, ρ(T), above T{sub c} was analyzed using Lawrence–Doniach (LD) and Aslamazov–Larkin (AL) models. Different fluctuation regimes indicated by short-wave fluctuation (SWF) and three-dimensional (3D), two-dimensional (2D), one-dimensional (1D), and critical region (CR) fluctuations were identified. The coherence length at zero temperature, the effective layer thickness, the critical magnetic fields, and the critical current densities are determined. The superconducting parameters strongly depend on the planetary ball milling technique, and the results are explained in relevancy to the microstructure. It was found that the achievement of a microstructure with well-dispersed nanoentities is an effective way for introducing pinning centers for enhancing critical current density and flux pinning capability of bulk Y-358.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct digital predistortion technique for the compensation of laser chirp and fiber dispersion in long haul radio over fiber links

Analog Radio-over-Fiber (A-RoF) communication technology constitutes a promising technique for next generation radio access networks thanks to its relatively low bandwidth requirements. Within this context, an efficient predistortion technique is proposed, which can be applied to reduce the impairments of A-RoF systems due to the combined effects of frequency chirp of the laser source and chromatic dispersion of the optical channel. The radio frequency signal is firstly put in digital form through an analog to digital converter, then the predistortion operation is realized, and finally the resulting signal is put again into analog form. A comprehensive analysis on the theoretical basis of the proposed approach is presented, together with the approximations introduced, which makes it practically realizable. The improvements on the quality of the received signal due to the proposed solution are illustrated with reference to scenarios of applicative interest. The performance of proposed technique is evaluated in terms of adjacent channel leakage ratio and error vector magnitude when long term evolution signal is applied at the input.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Processing Techniques for ODS Stainless Steels

Oxide dispersion-strengthened (ODS) alloys have been studied extensively, in part as a response to the need to develop the high-temperature materials that are required for energy efficient systems. ODS stainless steels, in particular, are of technological interest because of their high ductility and high strength at elevated temperatures, which when combined with their resistance to corrosion, render them ideal for many applications that require extreme performance quality. Survey of the published literature reveals that efforts have been devoted to incorporate specific strengthening mechanisms in order to meet demanding performance criteria for ODS alloys. As a result, a number of novel processing approaches have been developed in an effort to design distinct microstructures that can enhance the performance of ODS alloys. In the current paper, various techniques used to manufacture ODS stainless steel alloys are compared and summarized on the basis of a literature search, and results are contrasted with selected experimental data obtained by the authors. In particular, cryomilling, water-atomization, and melt-spinning processes are described in detail as three novel approaches that can be effectively used to distribute nanometric oxides in 316L stainless steel matrix. The microstructural features, mechanical properties, and sintering behavior of the fabricated materials are described and discussed. The critical processing parameters for each processing technique are discussed with reference to the properties of the material. The versatility and potential challenges of the individual techniques are also described and contrasted.

36 MATERIALS SCIENCE↗

A Technique for the Quantitative Characterization of Weld Microstructure and Application to Mo Welds

The choice of weld parameters determines the size, shape, and curvature of grains in the fusion zone (FZ) and heat-affected zone (HAZ) of welds while the mechanical properties of the welds are correlated to this microstructure. Here, a new technique to quantitatively evaluate these microstructural characteristics in both zones of welds has been applied to molybdenum gas tungsten arc welds fabricated using different weld parameters. Trends in microstructural characteristics in the FZ and HAZ were evaluated and correlated with changes to heat input, weld speed, and weld technique. The use of this approach showed that a 20 pct decrease in heat input caused a 20 pct decrease in the number of FZ grains with aspect ratios ≥ 4. The orientations of the FZ grain segments as a function of distance from the FZ centerline were significantly affected by the weld speed and its effect on weld pool shape. A 50 pct increase in weld speed caused a 20 pct decrease in grain segments orientated 60 to 90 deg from the normal to the direction of welding. This technique also captured differences in grain sizes and grain size anisotropy in the FZ between welds made with a constant current, pulsed current, and use of a 4-pole-magnetic oscillator.

36 MATERIALS SCIENCE↗

Transmission Electron Microscope In Situ Straining Technique to Directly Observe Defects and Interfaces During Deformation in Magnesium

In-situ straining was used to study deformation behavior of hexagonal close-packed (hcp) metals.Twinning and dislocation motion, both essential to plasticity in hcp materials, were observed.Typically, these processes are characterized post-mortem by examining remnant microstructural features after straining has occurred. By imposing deformation during imaging, direct observation of active deformation mechanisms is possible. This work focuses on straining of structural metals in a transmission electron microscope (TEM), and a recently developed technique that utilizes familiar procedures and equipment to increase ease of experiments. In-situ straining in a TEM presents several advantages over conventional post-mortem characterization, most notably time-resolution of deformation and streamlined identification of active deformation mechanisms. Drawbacks to the technique and applicability to other studies are also addressed. In-situ straining is used to study twin boundary motion in hcp magnesium. A {101¯2} twin was observed during tensile and compressive loading. Twin-dislocation interactions are directly observed. Notably, dislocations are observed to remain mobile, even after multiple interactions with twin boundaries, a result which suggests that Basinki’s dislocation transformation mechanism by twinning is not present in hcp metals. The coupling of in-situ straining with traditional post-mortem characterization yields more detailed information about material behavior during deformation than either technique alone.

magnesium↗

“Development and application of analytical detection techniques for droplet-based microfluidics”-A review

Droplet-based microfluidics has emerged as a powerful platform for high-throughput and low-volume analysis and screening. At present, droplet-based microfluidics is transitioning from the proof-of-concept stage to real-world applications. During this process, analytical detection techniques play indispensable roles for successfully implementing droplet-based chemical or biological assays. Here, we provide an overview of recent developments in analytical techniques for droplet analysis and elucidate the advantages and limitations of each technique. We cover the majority of technology categories, including optical detection, electrical detection, mass spectrometry, and nuclear magnetic resonance spectroscopy. Additionally, we highlight new research areas that have been enabled by these technical advances. Finally, we provide perspectives on both future technological directions and potential enabling applications.

47 OTHER INSTRUMENTATION↗

Ensemble Kalman filter for data assimilation coupled with low-resolution computations techniques applied in fluid dynamics

This paper presents an innovative Reduced-order model (ROM) for merging experimental and simulation data using data assimilation (DA) to estimate the "True" state of a fluid dynamics system, leading to more accurate predictions. Our methodology introduces a novel approach by implementing the ensemble Kalman filter (EnKF) within a reduced-dimensional framework, grounded in a robust theoretical foundation and applied to fluid dynamics. To address the substantial computational demands of DA, the proposed ROM employs low-resolution (LR) techniques to drastically reduce computational costs. This innovative approach involves downsampling datasets for DA computations, followed by an advanced reconstruction technique based on low-cost singular value decomposition (lcSVD). The lcSVD method, a key innovation in this paper, has never been applied to DA before and offers a highly efficient way to enhance resolution with minimal computational resources. Our results demonstrate significant reductions in both computation time and RAM usage through these LR techniques without compromising the accuracy of the estimations. For instance, in a turbulent test case, for a data compression rate of 15.9, the LR approach can achieve a speed-up of 13.7 and a RAM compression of 90.9% while maintaining a low relative root mean square error (RRMSE) of 2.6%, compared to 0.8% in the high-resolution (HR) reference. Furthermore, we highlight the effectiveness of the EnKF in estimating and predicting the state of fluid flow systems based on limited observations and given low-fidelity numerical data. This paper highlights the potential of the proposed DA method in fluid dynamics applications, particularly for improving computational efficiency in CFD and related fields. Its ability to balance accuracy with low computational and memory costs makes it especially suitable for large-scale and real-time applications, such as environmental monitoring or engineering design. This method will be incorporated into ModelFLOWs-app.

Data Assimilation↗

Low-order multiphysics coupling techniques for nuclear reactor applications

The accurate modeling and simulation of nuclear reactor designs depends greatly on the ability to couple differing sets of physics together. Current coupling techniques most often use a fixed-point, or Picard, iteration scheme in which each set of physics is solved separately, and the resulting solutions are passed between each solver. In the work presented here, two different coupling techniques are investigated: a Jacobian-Free Newton-Krylov (JFNK) approach and a new methodology called Coarse Mesh Finite Difference Coupling (CMFD-Coupling). In this work, both techniques were applied to the low-order CMFD system of equations. This allows for the multiphysics feedback effects to be captured on the low-order system without having to perform a neutron transport solve. The JFNK and CMFD-Coupling approaches were implemented in the MPACT neutron transport code, which is being developed for the Consortium for Advanced Simulation of Light Water Reactors (CASL). These methods were tested on a wide range of practical reactor physics problems, from a single 3D fuel pin to a massively parallel 3D full core problem. When coupled neutronics-thermal hydraulics problems were investigated with both JFNK and CMFD-Coupling, it was concluded that CMFD-Coupling outperformed JFNK in terms of both accuracy and runtime for every problem. When applied to large full core problems with multiple sources of strong feedback enabled, CMFD-Coupling reduced the overall number of transport sweeps required for convergence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagonal ordering operation technique applied to Morse oscillator

We generalize the technique called as the integration within a normally ordered product (IWOP) of operators referring to the creation and annihilation operators of the harmonic oscillator coherent states to a new operatorial approach, i.e. the diagonal ordering operation technique (DOOT) about the calculations connected with the normally ordered product of generalized creation and annihilation operators that generate the generalized hypergeometric coherent states. We apply this technique to the coherent states of the Morse oscillator including the mixed (thermal) state case and get the well-known results achieved by other methods in the corresponding coherent state representation. Also, in the last section we construct the coherent states for the continuous dynamics of the Morse oscillator by using two new methods: the discrete–continuous limit, respectively by solving a finite difference equation. Finally, we construct the coherent states corresponding to the whole Morse spectrum (discrete plus continuous) and demonstrate their properties according the Klauder’s prescriptions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗